PIR OnOff Page 2-3 PIR & Radar MinMaxOff Page 3-8. Sensor Manual LedgeCircle

Similar documents
HF Motion Sensor Introduction

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

False Ceiling HF Sensors

Sensors and Detectors

Tri-level Control HF Sensor

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Premium Version Tri-level Dimming Control

Tri-level Control HF Sensor

KNX/EIB - Product database - Application description

Sensors Explained AUTOMATION

IP65 High Bay Dual Sense Sensor

Movement-based energy control

Passive infrared ceiling sensor

IP65 High Bay Dual Sense Sensor

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

LINKABLE UNDERCABINET

Tri-level Control HF Sensor

Built-in HF Sensor for High Bay

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

North America Version / Dimming Function. Introduction

LED HIGH BAY LINEAR ECO SERIES

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Product Specifications

Lighting & Controls Motion & Presence Detectors

Loop out. Ambient daylight threshold

Integrated SensorDIM LED Driver Daylight Monitoring Version

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Daylight harvest function to regulate light output for maintaining required lux level

Ceiling PIR HS presence detector. Product Guide. Overview. Features

B.E.G. LUXOMAT. Find the right detector.

Installation Instructions

DHL-LP-LED Low Profile LED Linear High/Low Bay

HIGH POWER LED RETROFIT MODULE

e-sense move dali Manual

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

Sensors. EasyAir. office sensor advanced grouping SNS200. Design-in Guide. Single, compact, cost-effective luminaire control

Lighting Control Strategies. to meet code requirements save energy and improve building performance

1. Basic safety information 3 2. Proper use 3

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

, ,

Tri-level Control Sensor

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Integrated PIR detectors

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

UP 258E11 OPTISENS OFFICE

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Maestro 0 10 V Dimmer Sensor

Product and Applications Description

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Imperial War Museum. Case Study 17. clipsal.com UNITED KINGDOM. C-Bus Control and Management System

compact office 24V compact office 24V Lux

Data sheet. Function description. Benefits

0701 CO Light, HVAC, Monitoring, Brightness

LUX Hardwired - Installation Notes

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

LPCMPIRM65 & LPCMPIRDSI65

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Product Specifications

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Never forget to turn the lights off again. Motion Sensors

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

SCS motion sensors Surface/wall mounting - PIR

Occupancy and Vacancy Sensors

The Power To Supply... All Your Electrical Products

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Lighting and Fan Speed Controls

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

Mini Product Guide.

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

Tebis application software

Green Switch HD/HC/HS L/N/NT4658N - AM5658. Technical sheets - Automation MY HOME 1. Front view 8

IN2 Lighting Control Devices

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

System 2000 Automatic control switch 2 Standard. 1 Safety instructions. 2 Device components. 3 Function. Order-No. : Operating instructions

The Power To Supply... All Your Electrical Products

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Supervised Security System Owner's Guide

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Reduce lighting energy costs with controls

Installation Instructions

SECTION LIGHTING CONTROLS

Transcription:

PIR OnOff Page 2-3 PIR & Radar MinMaxOff Page 3-8 Sensor Manual LedgeCircle

PIR OnOff Description This light fixture has a built-in PIR motion sensor which turns ON and OFF after movement. This sensor only reacts to infrared light coming from heated objects and will not detect objects like moving elevators, objects behind walls or cars outside a window. That makes this sensor ideal for areas where you only want to detect people in direct presence. This sensor is suitable for smaller areas like toilets, wardrobes, entrances etc. if a longer and wider range of detection is needed, consider using the Radar version. PIR Sensor Function The light fixture turns ON full light when motion is detected and turns OFF when the hold time [T1] has run out without any motion. Placement of sensor The sensor detects heat change (IR) within 60 field of view. Place the sensor so that it has a clear view and is mounted at a distance/height that gives enough detection range. Avoid: Vibrations and high surrounding temperatures. A PIR sensor is better at sensing movement crossing sideways in comparison to movement going straight towards the sensor. Therefore, try to mount the light fixture so that it detects movement crossing the sensor. Best Sensitivity Less Sensitive 2

PIR OnOff The hold time [T1] can be set in steps from 8-sec to 25-min. Factory setting = 10min. Relay output The PIR OnOff light fixture acts as a master and has a 230V relay output. The output can drive light fixtures without sensors (slave) or any other kind of load. The output can supply a maximum of 100W. Two master s outputs cannot be connected. Light fixtures with sensors should not be connected to a switch or dimmer to manually operate the light. Master Slave Slave 3

PIR MinMaxOff Description This light fixture has a built-in infrared motion sensor which alternate between max light 100% (when motion is detected) and min 10% after preset time (without detection). After additional delay the light turns OFF. All settings are made via DIP-switches on the fitting or via remote control (accessory). This sensor only reacts to infrared light coming from heated objects and will not detect objects like moving elevators, objects behind walls or cars outside a window. That makes this sensor ideal for areas where you only want to detect people in direct presence. This sensor is suitable for smaller areas like toilets, wardrobes, entrances etc.if a longer and wider range of detection is needed, consider using the Radar version. Placement of sensor The sensor detects heat change (IR) within 100 field of view. PIR Sensor Avoid: Vibrations and high surrounding temperatures. A PIR sensor is better to sense movement crossing sideways in comparison to movement going straight towards the sensor. Therefore, try to mount the light fixture so that it detects movement crossing the sensor. Best Sensitivity Less Sensitive 4

Radar MinMaxOff Description This light fixture has a built-in radar-based motion sensor which alternate between max light 100% (when motion is detected) and min 10% after preset time (without detection). After additional delay the light turns OFF. All settings are made via DIP-switches on the fitting. This sensor uses radar to detect motion. The sensor is very effective and has a long range and wide coverage. It detects everything that is moving and will even go trough thin walls and windows. This makes it ideal for covering big areas or corridors where a PIR sensor would lack range or coverage. Radar Sensor Placement of sensor This sensor detects all types of movements within its detection range. Factory settings (100%) range as below Distance (D) Detection range (R) 1.5m 4.0m 3.0m 6.0m 5.0m 6.0m Please note The sensor should be mounted on a firm surface without vibrations Two or more sensors should not be placed within detection range of each other Pay attention to: unwanted detections through thin walls and windows, ventilation fans, Toiletpipes, big metal surfaces (can cause reflections) Close to the sensor avoid: Motor drivers, high power cables 5

PIR & Radar MinMaxOff Modes By changing settings, the light fixture can switch between 3 different modes: OnOff, MinMax and MinMaxOff. See page 7 and setting Stand-by period [T2] för adjusting mode. OnOff Goes to full light when motion is detected. After hold time [T1] it turns Off. MinMax Always a minimum light (adjustable). Goes to full light when motion is detected. MinMaxOff Full light when motion is detected. After first hold time [T1] it will dim down the light. After Second delay [T2] it will turn Off. 6

PIR & Radar MinMaxOff Detection range & sensitivity Adjust the sensitivity of the sensor. (PIR version is always 100%) Hold time [T1] The amount of time you would like to keep the light active (100%) after a person has left the detection area. Stand-by Period [T2] The amount of time you would like to keep the light at the dim-down level before switching OFF completely. 0s OnOff (will never dim down) MinMax (will never turn light OFF completely) 10s-30min MinMaxOff Daylight sensor This function (PIR version only) is used to preserve energy when there is already enough light in the area. This setting adjusts the light threshold for when the sensor should be activating. If the brightness sensor senses that the level of light is over the threshold, it will not activate even if presence is detected. For radar version, this should always be Disabled. Stand-by dimming Set the dim-down (Min) light level Factory settings 7

PIR & Radar MinMaxOff Master-Master Up to 10pcs light fixtures can be connected and linked together (Ext.). The lightfixture that detects motion will send an activation pulse to all connected light fixtures. After activation each light will use its individual settings. All MinMaxOff versions in the LedgeCircle range have this output (ext) and can be mixed and used together in the same group. Light fixtures with sensors should not be connected to a switch or dimmer to operate the light. Master Master Master Adress Telephone DEFA +46 10 498 38 00 Södra Kvistoftavägen 261 62 GLUMSLÖV www.defa.com 121967 E00 8