CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

Engineering Specification

TRANQUILITY THW WATER-TO-WATER. WATER-TO-WATER SYSTEMS SIZES 008, 010, AND 012 [8, 10 and 12 kw]

User Manual for Car Refrigerator/Freezer

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Tranquility (THW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES Hz [10 kw]

water to water heat pumps

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

MACH N-407 Heat Pump Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller

Model R060 Installation - Operation Manual

June PRODUCT DESIGN GUIDE Whisperline Console

GUIDE SPECIFICATIONS AQUARIUS ii

MAC-120HE-03 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

INSTALLATION, OPERATION AND MAINTENANCE

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Service & Parts Manual

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Installation and Operations Manual

Installation, Operation & Service Manual

*20D082-05NN* 20D082-05NN

Installation and Service Manual

INSTALLATION INSTRUCTIONS

Panel Mounted Heat Exchangers by Dantherm, Inc.

INSTRUCTIONS! DO NOT DISCARD!

Commercial High-Efficiency Condensing Units

Hazardgard. Product Profile. Engineered to perform in the harshest environments. Hazardous Location Room Air Conditioners

GT-PW (50YEW) Water-To-Water Series. WATER-TO-WATER PURON SYSTEMS SIZE 010 [10 kw]

14+ SEER R-410a AIR CONDITIONERS. Aluminum Coil Series. Efficiencies up to 14+ SEER/12 EER. Nominal Sizes Ton. Capacities 16.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

M1200 Series Limited Warranty Dependability Promise

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Rev. None AUGUST 2012 MDM SERIES MODULAR MEMBRANE AIR DRYERS OPERATOR MANUAL MDM1 MDM4 MDM9 MDM13 MDM24 MDM49 MDM66 MDM106 MDM138

Viessmann B1HA Boiler Series

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

GUIDE SPECIFICATIONS AQUARIUS ii

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

Safety & Installation Instructions

TRILOGY. 45 GEOTHERMAL SYSTEMS The World s Most Advanced Heating and Cooling System CLIMATEMASTER GEOTHERMAL HEATING AND COOLING

3 TON Heating Performance Data TON Cooling Performance Data TON Heating Performance Data TON Cooling Performance Data...

INSTRUCTIONS! DO NOT DISCARD!

Non-Programmable Digital Thermostat

Versatec Specification Catalog

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

AVAILABLE WITH ENERGY SAVING ECM MOTOR

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

Call us today! (800)

OWNER'S MANUAL T0140. Contents Page #

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Commercial High-Efficiency Condensing Units

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

INSTRUCTIONS! DO NOT DISCARD!

INSTALLATION AND OPERATION INSTRUCTIONS

DOM MODEL SERIAL NUMBER VOLTAGE/HERTZ/PHASE

Spa Control System OWNER S MANUAL

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

Transcription:

Engineering Specification W-25-HACW-P-1T-** Liquid to Water Geothermal Heat Pump 60 Hz Maritime Geothermal Ltd. P.O. Box 2555, 170 Plantation Road Petitcodiac, NB E4Z 6H4 (506) 756-8135 info@nordicghp.com www.nordicghp.com 000622SPC-04 ISSUE 02 18-Jan-2018

Model Nomenclature W 25 HACW P 1T CC xx Series: W = liquid to water (hydronic) Revision: 01, 02 etc. Nominal Size: 25 = 020 compressor 45 = 030 compressor 55 = 040 compressor 65 = 051 compressor 75 = 060 compressor 80 = 067/070 compressor Functions: H = Heating AC = Active Cooling W = Domestic Hot Water Refrigerant: P = R410a Indoor Loop Exchanger: C = Copper coaxial Y = CuNi coil & piping Z = CuNi coil only Outdoor Loop Exchanger: C = Copper coaxial Y = CuNi coil & piping Z = CuNi coil only Compressor: S = single stage scroll T = 2-stage scroll Voltage Code: 1 = 208/230-1-60 2 = 208-3-60 4 = 460-3-60 5 = 575-3-60 6 = 220-1-50 7 = 380-3-50 APPLICATION TABLE MODEL FUNCTION REFRIGERANT VOLTAGE COMPRESSOR STAGES OUTDOOR HEAT EXCHANGER INDOOR HEAT EXCHANGER REVISIONS W-25 HACW P 1 2 4 T C Y Z C Y Z 09 This manual applies only to the models and revisions listed in this table. Maritime Geothermal Ltd. has a continuous improvement policy and reserves the right to modify specification data at any time without prior notice. 18-Jan-2018 Page 2 000622SPC-04 ISSUE 02

Design Features AHRI certified for performance Energy Star listed for performance CSA certified for safety (CSA 22.2 No 236-05) CE certified to 60335-1 and 60335-2-40 Satin galvanized steel cabinet Powder coat finish Acoustically insulated cabinet (1/2 & 1 thick) All connections located on same side Access panels for all four sides, serviceable from two sides Swing out electrical box for easy access to compressor Component layout allows easy access for service Refrigeration service ports located inside unit (1/4 Schrader) Insulated coaxial heat exchanger and piping, available in copper or cupro-nickel (CuNi) 1 brass FPT fittings for loop connections Connection points for outdoor and indoor circulator pump power Two-stage scroll compressor with start capacitor kit on single phase models Dual-grommet-mounted compressor for reduced noise and vibration Suction line accumulator Liquid line filter-dryer Liquid line sight glass Balanced port thermostatic expansion valve (TXV) with internal bleed 4-way reversing valve High and low pressure safety controls Control board with random start, anti-short cycle timer, auto-retry and permanent lockout mode Electrical box layout and schematic diagrams Double wall Domestic Hot Water (DHW) desuperheater suitable for heating potable water Brass head ECM circulator for domestic hot water circuit uses less than half the power of traditional circulating pumps and allows motor replacement without tools 1/2 brass FPT fittings for Domestic Hot Water connections Available Accessories 2 stage aquastat with selectable heating or cooling per stage Circulator pump module with loop / unit isolation valves (230VAC) for ground loop applications Barbed P/T port adapters for heat pump Anti-vibration pad for under unit Compressor sound jacket Secure Start module 1 water valve (slow closing or solenoid) & wiring harness for open loop applications Electric plenum heaters 5 / 7 / 10 / 15 / 20 kw, internally mountable for top fan outlet configuration 18-Jan-2018 Page 3 000622SPC-04 ISSUE 02

Design Features High and low refrigerant access ports Cabinet completely insulated with 1 & 1/2 acoustic insulation Powder coat finish inside and out Fault monitoring board with lock-out indicator and anti-short cycle timer Heavy duty electrical components Start capacitor kit standard on all single phase models Heavy duty cabinet Four removable access panels for easy servicing Sight glass Bi-flow filter-dryer Balanced port TXV with off cycle equalization port 4-way reversing valve High efficiency coaxial heat exchangers. Copper or CuNi available. ECM domestic hot water circulator pump. Thermostat: ON @ 120 F OFF @ 140 F Swing out electrical box 1/2 Brass FPT connection ports for DHW Heavy duty heat pump rated Copeland twostage scroll compressor 1 Brass FPT connection ports Mounting plate system for compressor Suction accumulator CSA certified for electrical safety to CSA 22.2 No 236-05. Optional water valve for ground water installations 18-Jan-2018 Page 4 000622SPC-04 ISSUE 02

Dimensions 18-Jan-2018 Page 5 000622SPC-04 ISSUE 02

Specifications Electrical Specifications Nomenclature Identifier Shipping Information Power Supply Compressor FLA MCA Maximum Fuse/Breaker Minimum Wire Size* V-ø-Hz MIN MAX RLA LRA Amps Amps Amps ga 1 208/230-1-60 187 253 11.7 58 17.5 20.4 30 #10-2* 2 208-3-60 187 229 6.5 55 12.3 13.9 20 #12-3* 4 460-3-60 414 506 3.5 28 4.3 5.2 15 #14-3 * additional conductor required if connecting 115VAC circulators to the unit MODEL WEIGHT DIMENSIONS in (cm) lb. (kg) L W H W-25 305 (138) 34 (86) 34 (86) 35 (89) Refrigerant Charge (Per Circuit) MODEL lb kg Oil Type W-25 4.0 1.8 POE - Oil capacity is marked on the compressor label. - Refrigerant charge is subject to revision; actual charge is indicated on the unit nameplate. Loop Pressure Drops INDOOR (water 104 F) OUTDOOR (water 50 F) OUTDOOR (15% methanol 32 F) OUTDOOR (35% prop. glycol 32 F) gpm L/s psi kpa psi kpa psi kpa psi kpa 4 0.25 0.8 5.5 0.9 6.2 0.9 6.2 1.2 8.2 5 0.32 1.3 9.0 1.4 10 1.4 9.6 1.8 13 6 0.38 1.6 11 1.7 12 1.9 13 2.5 17 7 0.44 2.1 14 2.3 16 2.4 17 3.2 22 8 0.50 3.0 21 3.2 22 3.0 21 4.0 27 9 0.57 3.1 21 3.4 23 3.9 27 5.1 35 10 0.63 4.1 28 4.4 30 4.8 33 6.3 43 11 0.69 4.8 33 5.1 35 5.7 39 7.5 52 12 0.76 5.7 39 6.0 41 6.6 45 8.7 60 13 0.82 6.7 46 6.9 48 7.7 53 10.1 70 Operating Temperature Limits Loop Parameter Mode ( F) ( C) Note Minimum ELT Heating / Cooling 39 4 Ground water system. Outdoor Minimum ELT Heating 23-5 Ground loop system. Adequate freeze protection required. Minimum ELT Cooling 32 0 Ground loop system. Adequate freeze protection required. Maximum ELT Cooling 113 45 Ground loop system. Indoor Minimum EWT Heating / Cooling 50 10 Reduce flow if necessary during heating startup. Maximum EWT Heating 113 45 * Values in this table are for rated liquid and water flow values. 18-Jan-2018 Page 6 000622SPC-04 ISSUE 02

Standard Capacity Ratings Standards C13256-2 / ISO13256-2 / ARI 13256-2 Standard Capacity Ratings - Ground Loop Heating* EWT 104 F (40 C) Model Standard Capacity Ratings - Ground Loop Cooling* EWT 53.6 F (12 C) Model Size (compr) Liquid Flow (Outdoor & Indoor) Outdoor Pressure Drop Mode Input Energy 60Hz STAGE 1 - ELT 68 F (20 C) STAGE 2 - ELT 77 F (25 C) Capacity COP C EER gpm L/s psi kpa Watts Btu/hr kw W/W Stage 1 800 17,100 5.0 6.3 21.4 W-25 020 8.0 0.50 4.0 28 Stage 2 1,305 21,000 6.2 4.7 16.1 * 15% NaCl by Weight Ground Loop Fluid Standard Capacity Ratings - Ground Water Cooling EWT 53.6 F (12 C) Model Size (compr) Size (compr) Liquid Flow (Outdoor & Indoor) Liquid Flow (Outdoor & Indoor) Outdoor Pressure Drop Outdoor Pressure Drop Mode Mode Input Energy Input Energy 60Hz STAGE 1 - ELT 41 F (5 C) STAGE 2 - ELT 32 F (0 C) Capacity 60Hz ELT 59 F (15 C) Capacity COP C EER gpm L/s psi kpa Watts Btu/hr kw W/W Stage 1 695 17,700 5.2 7.5 25.5 W-25 020 8.0 0.50 3.9 27 Stage 2 1,105 23,200 6.8 6.2 21.0 COP H gpm L/s psi kpa Watts Btu/hr kw W/W Stage 1 1,290 14,100 4.1 3.2 W-25 020 8.0 0.50 4.9 34 Stage 2 1,635 17,300 5.1 3.1 * 15% NaCl by Weight Ground Loop Fluid Standard Capacity Ratings - Ground Water Heating EWT 104 F (40 C) Model Size (compr) Liquid Flow (Outdoor & Indoor) Outdoor Pressure Drop Mode Input Energy Capacity 60Hz ELT 50 F (10 C) COP H gpm L/s psi kpa Watts Btu/hr kw W/W Stage 1 1,300 16,400 4.8 3.7 W-25 020 8.0 0.50 4.2 29 Stage 2 1,740 22,600 7.1 3.8 18-Jan-2018 Page 7 000622SPC-04 ISSUE 02

Performance Tables W-25-HACW-P-1T ELT Source Data (Outdoor Loop) Evap. Temp Heating Mode (Full Load) Power Consumption Flow LLT Delta T HAB Total Effective COPh EWT R410a 60 Hz Sink Data (Indoor Loop) Cond. Net Flow LWT Delta T Temp. Output F F gpm F F Btu/hr Watts Amps Watts W/W F F gpm F F Btu/hr C C L/s C C Watts C C L/s C C Watts 25.0 20 8.0 22.2 2.8 10,551 1,502 7.0 1,603 2.89 104.0 109 8.0 108.0 4.0 15,828-3.9-6.7 0.505-5.4 1.5 3,092 40.0 42.8 0.505 42.2 2.2 4,638 31.0 25 8.0 27.9 3.1 11,713 1,519 7.0 1,619 3.08 104.0 110 8.0 108.3 4.3 17,046-0.6-3.9 0.505-2.3 1.7 3,432 40.0 43.3 0.505 42.4 2.4 4,994 37.0 30 8.0 33.6 3.4 13,049 1,516 7.0 1,617 3.33 104.0 110 8.0 108.6 4.6 18,374 2.8-1.1 0.505 0.9 1.9 3,823 40.0 43.3 0.505 42.6 2.6 5,383 43.0 35 8.0 39.2 3.8 14,379 1,532 7.1 1,633 3.55 104.0 111 8.0 108.9 4.9 19,759 6.1 1.7 0.505 4.0 2.1 4,213 40.0 43.9 0.505 42.7 2.7 5,789 48.0 40 8.0 43.7 4.3 16,172 1,649 7.1 1,746 3.69 104.0 111 8.0 109.5 5.5 21,962 8.9 4.4 0.505 6.5 2.4 4,738 40.0 43.9 0.505 43.1 3.1 6,435 54.0 45 8.0 49.3 4.7 17,705 1,666 7.2 1,762 3.92 104.0 112 8.0 109.9 5.9 23,552 12.2 7.2 0.505 9.6 2.6 5,188 40.0 44.4 0.505 43.3 3.3 6,901 60.0 50 8.0 54.9 5.1 19,457 1,661 7.1 1,758 4.22 104.0 112 8.0 110.3 6.3 25,289 15.6 10.0 0.505 12.7 2.8 5,701 40.0 44.4 0.505 43.5 3.5 7,410 66.0 55 8.0 60.4 5.6 21,180 1,676 7.2 1,773 4.47 104.0 113 8.0 110.8 6.8 27,063 18.9 12.8 0.505 15.8 3.1 6,206 40.0 45.0 0.505 43.8 3.8 7,929 W-25-HACW-P-1T Cooling Mode (Full Load) Compressor: ZPS20K5E-PFV R410a 60 Hz Source Data (Indoor Loop) Power Consumption Sink Data (Outdoor Loop) ELT Evap. Efficiency Temp. Cond. Flow LLT Delta T HAB Total Effective ELT Temp Flow LLT Delta T Rejection F F gpm F F Btu/Hr Watts Amps Watts EER F F gpm F F Btu/hr C C L/s C C Watts COPc C C L/s C C Watts 53.6 41.0 8.0 47.7 5.9 23,610 897 3.9 995 7.0 52 65 8.0 59.0 7.0 26,670 12.0 5.0 0.505 8.7 3.3 6,918 23.7 11 18.3 0.505 15.0 3.9 7,814 53.6 41.5 8.0 47.8 5.8 23,380 976 4.2 1,075 6.4 57 70 8.0 64.0 7.0 26,712 12.0 5.3 0.505 8.8 3.2 6,850 21.8 14 21.1 0.505 17.8 3.9 7,827 53.6 42.0 8.0 47.8 5.8 23,122 1,052 4.6 1,151 5.9 62 75 8.0 69.0 7.0 26,713 12.0 5.6 0.505 8.8 3.2 6,775 20.1 17 23.9 0.505 20.6 3.9 7,827 53.6 42.5 8.0 47.9 5.7 22,834 1,126 4.9 1,225 5.5 67 80 8.0 74.0 7.0 26,678 12.0 5.8 0.505 8.8 3.2 6,690 18.6 19 26.7 0.505 23.3 3.9 7,817 53.6 43.0 8.0 48.3 5.3 21,229 1,147 5.2 1,247 5.0 73 85 8.0 79.6 6.6 25,143 12.0 6.1 0.505 9.0 3.0 6,220 17.0 23 29.4 0.505 26.5 3.7 7,367 53.6 43.5 8.0 48.4 5.2 20,901 1,218 5.5 1,318 4.6 78 90 8.0 84.6 6.6 25,058 12.0 6.4 0.505 9.1 2.9 6,124 15.9 26 32.2 0.505 29.2 3.7 7,342 53.6 44.0 8.0 48.5 5.1 20,545 1,291 5.9 1,391 4.3 83 95 8.0 89.6 6.6 24,952 12.0 6.7 0.505 9.1 2.9 6,020 14.8 28 35.0 0.505 32.0 3.6 7,311 53.6 44.5 8.0 48.6 5.0 20,161 1,368 6.2 1,468 4.0 88 100 8.0 94.5 6.5 24,831 12.0 6.9 0.505 9.2 2.8 5,907 13.7 31 37.8 0.505 34.7 3.6 7,275 Compressor: ZPS20K5E-PFV 18-Jan-2018 Page 8 000622SPC-04 ISSUE 02

Wiring Diagram (208/230-1-60) 18-Jan-2018 Page 9 000622SPC-04 ISSUE 02

Electrical Box Layout (208/230-1-60) 18-Jan-2018 Page 10 000622SPC-04 ISSUE 02

Wiring Diagram (208-3-60) 18-Jan-2018 Page 11 000622SPC-04 ISSUE 02

Electrical Box Layout (208-3-60) 18-Jan-2018 Page 12 000622SPC-04 ISSUE 02

Wiring Diagram (460-3-60) 18-Jan-2018 Page 13 000622SPC-04 ISSUE 02

Electrical Box Layout (460-3-60) 18-Jan-2018 Page 14 000622SPC-04 ISSUE 02

18-Jan-2018 Page 15 000622SPC-04 ISSUE 02

18-Jan-2018 Page 16 000622SPC-04 ISSUE 02

Engineering Guide Specifications General The liquid source reversing water-to-water heat pump shall be a single packaged reverse-cycle heating/cooling unit, with desuperheating circuit for domestic hot water heating. The unit shall be listed by a nationally recognized safety-testing laboratory or agency, such as ETL Testing Laboratory, Underwriters Laboratory (UL), or Canadian Standards Association (CSA). The unit shall be rated in accordance with applicable standards of the Air Conditioning, Heating, and Refrigeration Institute / International Standards Organization (AHRI/ISO) and/or Canadian Standards Association (CSA). The liquid source water to water heat pump unit, as manufactured by Maritime Geothermal, Petitcodiac, New Brunswick, shall be designed to operate correctly within liquid temperature ranges specified on the Operating Temperature Limits table in this engineering specification document. Factory Quality Each unit shall be run tested at the factory with water circulating through the indoor and outdoor loops. Quality control system checks shall include: computerized nitrogen pressurized leak test, evacuation of refrigeration circuit to sustained vacuum, accurate system charge, detailed heating and cooling mode tests, and quality cross check all operational and test conditions to pass/fail criteria. Units tested without water flow are not acceptable. The units shall be warranted by the manufacturer against defects in materials and workmanship in accordance with the warranty section at the end of this document. Optional extended factory warranty coverage may be available. Cabinet Each unit shall be enclosed in a sheet metal cabinet. Cabinet shall be constructed of powder coated galvanized sheet metal of minimum 20 gauge. Sheet metal gauge shall be higher where structurally required. Design and construction of cabinet shall be such that it is rigid and passes the CSA/UL Loading Test requirements (200 lb roof test and 25 lb guard test). All panels shall be lined with minimum 1/2 inch [12.7 mm] thick acoustic type glass fiber insulation. All insulation shall meet the fire retardant provisions of NFPA 90A. This material shall also provide acoustical benefit. The unit must have a minimum of three access panels for serviceability of the compressor compartment. Units having only one access panel to compressor/heat exchangers/expansion device/refrigerant piping shall not be acceptable. The electrical box shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. All factory-installed wiring passing through factory knockouts and openings shall be protected from sheet metal edges at openings by plastic grommets. Refrigerant Circuit All units shall contain only one sealed refrigerant circuit, containing a hermetic motor scroll compressor, two coaxial heat exchangers, thermostatic expansion valve (TXV), reversing valve, factory installed high and low pressure safety switches, service ports, liquid line filter-dryer, sight glass, desuperheating heat exchanger, and suction accumulator. Compressors shall be specified for heat pump duty with internal isolation consisting of rubber vibration isolators between the compressor and mounting plate, and rubber vibration isolators between the mounting plate and cabinet. Compressor motors shall have internal overload protection. The water to refrigerant heat exchangers shall consist of a steel outer jacket with twisted copper inner tube, designed and certified for 600 psig [4136 kpa] working pressure on the refrigerant side and 450 psig [3108 kpa] on the water side. Heat exchangers headered together in parallel shall use a reverse-return or symmetrical arrangement on the water side and symmetrical arrangement on the refrigerant side to ensure even flow splitting. Heat exchangers shall be insulated over all of their outside surface with minimum 3/8 thick closed cell insulation. Insulation consisting of 1/8 closed-cell insulating tape shall not be acceptable. Cupro-nickel (CuNi) inner tube shall be available as a factory option. The thermostatic expansion valve shall be a balanced port bi-flow type with internal bleed and shall provide proper superheat control over the unit s operating range with minimal deviation from the superheat setpoint. 18-Jan-2018 Page 17 000622SPC-04 ISSUE 02

Piping and Connections The unit shall have two sets of primary water in and out connections (for indoor and outdoor loops). The primary connection type shall be 1 nominal female National Pipe Thread (NPT). Domestic hot water (desuperheater) water connectors shall be ½ nominal female National Pipe Thread (NPT). All water connectors shall be rigidly mounted to cabinet with corrosion resistant fasteners to prevent relative movement. All water connectors shall be constructed of copper or brass material for corrosion resistance. All internal water and refrigerant piping shall be insulated with minimum 3/8 thick closed cell insulation. Insulation consisting of 1/8 closed-cell insulating tape shall not be acceptable. Electrical Controls and safety devices shall be factory wired and mounted within the unit. Controls shall include a 24 volt alternating current (24VAC) 75VA class II control transformer with resettable breaker or fuses for short circuit protection, to provide power to all internal controls as well as a remote thermostat. Terminal strips with screw terminals shall be provided for field control wiring, power supply line connections and 115/230VAC power supply for outdoor loop (ground loop) circulators. Units shall be name-plated for use with time delay fuses or circuit breakers. Unit Control The control system shall have the following features: 1. Anti-short cycle time delay on compressor operation. Time delay shall be a minimum of 5 minutes, for both thermostat demand and safety control reset starts. A test jumper shall be provided to disable this delay for unit commissioning and testing purposes. The unit shall revert to normal operation after a time delay if the test jumper is accidentally left in place. 2. Random compressor start delay of 0-120 seconds (in addition to 5 minute anti-short cycle timer) on unit power up to facilitate starting multiple units on one disconnect switch or after a power failure. 3. Compressor shutdown for high or low refrigerant pressures. 4. Low grid voltage or brownout protection, which will prevent compressor operation if low voltage is detected. 5. Automatic intelligent reset: unit shall automatically restart 5 minutes after a trip if the fault has cleared. Should a fault reoccur again within 60 minutes then a permanent lockout shall occur, requiring cycling of the power to the unit in order to reset. Maritime Geothermal works continually to improve its products. As a result, the design and specifications of any product may be changed without notice. Please contact Maritime Geothermal at 1-506-756-8135 or visit www.nordicghp.com for latest design and specifications. Purchaser s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the basis of any commercial contract or other agreement between any parties, but are merely Maritime Geothermal s statement of opinion regarding its products. 18-Jan-2018 Page 18 000622SPC-04 ISSUE 02

LIMITED EXPRESS WARRANTY It is expressly understood that unless a statement is specifically identified as a warranty, statements made by Maritime Geothermal Ltd., a corporation registered in New Brunswick, Canada, ( MG ) or its representatives, relating to MG s products, whether oral, written or contained in any sales literature, catalogue or agreement, are not express warranties and do not form a part of the basis of the bargain, but are merely MG s opinion or commendation of MG s products. EXCEPT AS SPECIFICALLY SET FORTH HEREIN, THERE IS NO EXPRESS WARRANTY AS TO ANY OF MG S PRODUCTS. MG MAKES NO WARRANTY AGAINST LATENT DEFECTS. MG MAKES NO WARRANTY OF MERCHANTABILITY OF THE GOODS OR OF THE FITNESS OF THE GOODS FOR ANY PARTICULAR PURPOSE. LIMITED EXPRESS RESIDENTIAL WARRANTY - PARTS MG warrants its Residential Class products, purchased and retained in the United States of America and Canada, to be free from defects in material and workmanship under normal use and maintenance as follows: (1) Air conditioning, heating and/or heat pump units built or sold by MG ( MG Units ) for five (5) years from the Warranty Inception Date (as defined below). (2) Thermostats, auxiliary electric heaters and geothermal pumping modules built or sold by MG, when installed with MG Units, for five (5) years from the Warranty Inception Date (as defined below). (3) Sealed refrigerant circuit components of MG Units (which components only include the compressor, refrigerant to air/water heat exchangers, reversing valve body and refrigerant metering device) for ten (10) years from the Warranty Inception Date (as defined below). (4) Other accessories and parts built or sold by MG, when installed and purchased with MG Units, for five (5) years from the date of shipment from MG. (5) Other accessories, when purchased separately, for (1) year from the date of shipment from MG. The Warranty Inception Date shall be the date of original unit installation, as per the date on the installation Startup Record or six (6) months from date of unit shipment from MG, whichever comes first. To make a claim under this warranty, parts must be returned to MG in Petitcodiac, New Brunswick, freight prepaid, no later than ninety (90) days after the date of the failure of the part. If MG determines the part to be defective and within MG s Limited Express Residential Warranty, MG shall, when such part has been either replaced or repaired, return such to a factory recognized distributor, dealer or service organization, freight prepaid. The warranty on any part repaired or replaced under warranty expires at the end of the original warranty period. LIMITED EXPRESS RESIDENTIAL WARRANTY - LABOUR This Limited Express Residential Labour Warranty shall cover the labour incurred by MG authorized service personnel in connection with the installation of a new or repaired warranty part that is covered by this Limited Express Residential Warranty only to the extent specifically set forth in the current labour allowance schedule "A" provided by MG s Warranty Department and only as follows: (1) MG Units for two (2) years from the Warranty Inception Date. (2) Thermostats, auxiliary electric heaters and geothermal pump modules built or sold by MG, when installed with MG Units, for two (2) years from the Warranty Inception Date. (3) Sealed refrigerant circuit components of MG Units (which components only include the compressor, refrigerant to air/water heat exchangers, reversing valve body and refrigerant metering device) for five (5) years from the Warranty Inception Date. Labour costs are not covered by this Limited Express Residential Warranty to the extent they exceed the amount allowed under said allowance schedule, they are not specifically provided for in said allowance schedule, they are not the result of work performed by MG authorized service personnel, they are incurred in connection with a part not covered by this Limited Express Residential Warranty, or they are incurred more than the time periods set forth in this paragraph after the Warranty Inception Date. This warranty does not cover and does not apply to: (1) Air filters, fuses, refrigerant, fluids, oil. (2) Products relocated after initial installation. (3) Any portion or component of any system that is not supplied by MG, regardless of the cause of the failure of such portion or component. (4) Products on which the unit identification tags or labels have been removed or defaced. (5) Products on which payment to MG, or to the owner s seller or installing contractor, is in default. (6) Products subjected to improper or inadequate installation, maintenance, repair, wiring or voltage conditions. (7) Products subjected to accident, misuse, negligence, abuse, fire, flood, lightning, unauthorized alteration, misapplication, contaminated or corrosive liquid or air supply, operation at abnormal air or liquid temperatures or flow rates, or opening of the refrigerant circuit by unqualified personnel. (8) Mold, fungus or bacteria damage (9) Corrosion or abrasion of the product. (10) Products supplied by others. (11) Products which have been operated in a manner contrary to MG s printed instructions. (12) Products which have insufficient performance as a result of improper system design or improper application, installation, or use of MG s products. (13) Electricity or fuel, or any increases or unrealized savings in same, for any reason whatsoever. Except for the limited labour allowance coverage set forth above, MG is not responsible for: (1) The costs of fluids, refrigerant or system components supplied by others, or associated labour to repair or replace the same, which is incurred as a result of a defective part covered by MG s Limited Residential Warranty. (2) The costs of labour, refrigerant, materials or service incurred in diagnosis and removal of the defective part, or in obtaining and replacing the new or repaired part. (3) Transportation costs of the defective part from the installation site to MG, or of the return of that part if not covered by MG s Limited Express Residential Warranty. (4) The costs of normal maintenance. This Limited Express Residential Warranty applies to MG Residential Class products manufactured on or after February 15, 2010. MG S LIABILITY UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL APPLY ONLY TO THE MG UNITS REGISTERED WITH MG THAT BEARS THE MODEL AND SERIAL NUMBERS STATED ON THE INSTALLATION START UP RECORD, AND MG SHALL NOT, IN ANY EVENT, BE LIABLE UNDER THE TERMS OF THIS LIMITED WARRANTY UNLESS THIS INSTALLATION START UP RECORD HAS BEEN ENDORSED BY OWNER & DEALER/INSTALLER AND RECIEVED BY MG LIMITED WITHIN 90 DAYS OF START UP. Limitation: This Limited Express Residential Warranty is given in lieu of all other warranties. If, not withstanding the disclaimers contained herein, it is determined that other warranties exist, any such express warranty, including without imitation any express warranties or any implied warranties of fitness for particular purpose and merchantability, shall be limited to the duration of the Limited Express Residential Warranty. LIMITATION OF REMEDIES In the event of a breach of the Limited Express Residential Warranty, MG will only be obligated at MG s option to repair the failed part or unit, or to furnish a new or rebuilt part or unit in exchange for the part or unit which has failed. If after written notice to MG s factory in Petitcodiac, New Brunswick of each defect, mal-function or other failure, and a reasonable number of attempts by MG to correct the defect, malfunction or other failure, and the remedy fails of its essential purpose, MG shall refund the purchase price paid to MG in exchange for the return of the sold good(s). Said refund shall be the maximum liability of MG. THIS REMEDY IS THE SOLE AND EXCLUSIVE REMEDY OF THE BUYER OR PURCHASER AGAINST MG FOR BREACH OF CONTRACT, FOR THE BREACH OF ANY WARRANTY OR FOR MG S NEGLIGENCE OR IN STRICT LIABILITY. LIMITATION OF LIABILITY MG shall have no liability for any damages if MG s performance is delayed for any reason or is prevented to any extent by any event such as, but not limited to: any war, civil unrest, government restrictions or restraints, strikes, or work stoppages, fire, flood, accident, shortages of transportation, fuel, material, or labour, acts of God or any other reason beyond the sole control of MG. MG EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE IN CONTRACT, FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, OR IN TORT, WHETHER FOR MG s NEGLIGENCE OR AS STRICT LIABILITY. OBTAINING WARRANTY PERFORMANCE Normally, the dealer or service organization who installed the products will provide warranty performance for the owner. Should the installer be unavailable, contact any MG recognized distributor, dealer or service organization. If assistance is required in obtaining warranty performance, write or call: Maritime Geothermal Ltd Customer Service PO Box 2555 Petitcodiac, New Brunswick E4Z 6H4 (506) 756 8135 or e-mail to info@nordicghp.com NOTE: Some states or Canadian provinces do not allow limitations on how long an implied warranty lasts, or the limitation or exclusions of consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state and from Canadian province to Canadian province. Please refer to the MG Installation, Installation and Service Manual for operating and maintenance instructions. An extended warranty option is also available. Please contact Maritime Geothermal Ltd. via the contact information in the previous paragraph for more information. 18-Jan-2018 Page 19 000622SPC-04 ISSUE 02