Stainless Steel 201. Considerations about an important ingredient of the brewery plant

Similar documents
High Pressure Manways CODAP 2000 & PED 96/23/CE

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

CLEANING DETERGENT SOLUTIONS IN CONSTRUCTION

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Mixing Tank, 500 Gallon with Agitator

Treatment of Digester Gas

VELFAC 860 BI-FOLD DOOR USER & MAINTENANCE GUIDE

Growler: Best Practices and New Technologies. Charles Kyle Sierra Nevada Brewing Company

Solid Door Top Mount Reach-In Freezer

Glass Door Merchandiser Refrigerator and Freezer

Please do not return this product to the retailer!!! If you find that you have any trouble with assembly or missing or damaged parts please contact

Which RO/DI Water Heater is Right For Your Application? By: Caitlin Carrier

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Chef Base Refrigerators

Duke Manufacturing Co.

about our systems our programs closed loop technology

3M Aerosols. Electrical Products Division. 3 Innovation

E-Chef Hot Food Table Installation and Operation Manual

A powerful organic cleaner and degreaser that enhances workplace safety without compromising performance.

CONCRETE CLEANING BEST PRACTICES

ACORE Filtration Co.,Ltd provides engineering,

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

SPØ1 OUTDOOR CARE INSTRUCTIONS

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

NOZZLES FOR BOTTLE, DRUM, AND TANK WASHING

METALÚRGICA SIEMSEN LTDA. INSTRUCTION MANUAL CENTRIFUGAL JUICER MODELS CS / CSE

DEEP VACUUM: ITS PRINCIPLE AND APPLICATION

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Why Clean? Sell more beer!

CHX Heat Recovery THE Solution. Steam Plant Systems, Inc.

EUROSPRINT NEXT TECHNICAL DATA SHEET

Safety Considerations for Hydrogen Installations

What you need to know...

Brilliant products. Fermentation and brite beer tanks

ENCAPSULATION CLEANING TECHNOLOGY. An overview of encapsulation chemistry and its applications

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

CAM AFRICA PREMUIM RANGE

Nu-Brite Same popular Nu-Brite Powerful high foaming action lifts out dirt and grime while brightening coils Excellent & powerful cleaner that is espe

ALTURA 619 EXTRA TECHNICAL SHEET

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Inverted Bucket Steam Traps

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

Effingham County Health Department "Where Prevention Begins" 901 West Virginia Phone (217) Effingham, Illinois Fax (217)

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Ampco s Complete Line of AC SERIES PUMPS AC, AC+, IC+

INSTALLATION AND USER MANUAL

CORTEC. CORTEC

Module 7: Air Supply System

PLATE HEAT EXCHANGERS

Annual Tune-Up Procedure

INSTALLATION & OPERATION MANUAL

316 Stainless Steel TS 8 Enclosure. The most rugged TS 8 yet

Flanged Immersion Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

INSTALLATION AND USER MANUAL

Checklist Selecting the Proper Flanged Heater

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Rycroft Supapac Plate Heat Exchangers

Brilliant products. Beer fermentation and storage tanks

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

Insta-Therm Series Service, Installation and Operation Manual

Pocket Hardmount. Preventative Maintenance.

User s Information Manual

Dry Ice Blasting Frequently Asked Questions

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

PLATE HEAT EXCHANGER

3.1 Deaerator Systems

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

Professional Flooring Contractor Shares Secrets To A Successful Garage Floor Coating Project

FALLING FILM CHILLERS

Cleaning and care guide for material surfaces

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Drop-In Installation Instructions. Undermount Installation Instructions

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

White Paper EXPLOSION PROTECTION EXPLOSION PROTECTION SOLUTIONS FOR SANITARY HYGIENIC APPLICATIONS IN THE FOOD & PHARMACEUTICAL INDUSTRY

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Channel plates Heat is transferred from one medium to the other through the thin channel plates.

Application of a Reagentless Direct Conductivity Online TOC Analyzer for Clean-in-Place Verification

INSTALLATION & OPERATION MANUAL

GREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Did You Know? PureFlex Offers a Vareity of Operators For Those Hard-To-Reach Installations. Left Hand or Right Hand Operation

Stress Corrosion Technical Bulletin

Thermal Steel Care & Maintenance Guide

INSTALLATION & OPERATION MANUAL

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Models: FM FM WARNING

The Yellow Can Removes oils & fatty acids

User s Information Manual

IB 15/80 Ice Blaster. Innovative cleaning with dry ice: No residue, no chemicals.

Daikin Water Cooling, Heating, and High Capacity Booster Coils

Transcription:

Stainless Steel 201 Considerations about an important ingredient of the brewery plant Ashton Lewis Brewery Product Manager Paul Mueller Company Springfield, MO

Why is Stainless Steel A Good Fit for the Duty Used? Mechanical Properties Malleable Strong Easily welded Easy to polish Durable

Malleability Allows heads to be dished

Malleability Allows heads to be dished and Flanged

Malleability Allows heads to be dished Tubing can be drawn and Flanged

Surface Finishes Requirements Duty Dependent Finish Types 2B / Cold Rolled Mechanically Polished Hot Rolled, Annealed and Pickled (HRAP)

Durable To a Point!

Stainless is not Absolute Chloride Pitting Stress Corrosion Cracking

Steel Type Picking the proper tool for the job Type 304 Most common austenitic stainless type used in food and beverage processing Commonly referred to as 18-8 Most brewing equipment is fabricated from Type 304 stainless Relative cost = 1.00

Steel Type Picking the proper tool for the job Type 316 Similar to Type 304, except for the inclusion of 2% molybdenum Moly adds improved resistance to chlorides and helps ward off pitting corrosion Type 316 is the most common type of stainless steel used in pharmaceutical equipment Also commonly used for surgical instruments Relative cost ~ 1.30

Big Salt Piles Contribute to Great Diving!

Steel Type Picking the proper tool for the job 2205 Duplex steel Magnetic Does not readily succumb to SCC Readily available More difficult to form than Types 304 and 316 Difficult to apply heating surfaces Relative cost ~ 2.00

Steel Type Picking the proper tool for the job AL6XN Austenitic Does not readily succumb to SCC Readily available Has similar forming and fabrication qualities to Types 304 & 316 Expensive Relative cost ~ 4.50

Steel Type Summary of Alloy Compositions Alloy Cr Ni Mo Cu N C 304L 18-20% 8-12% - - 0.10% max 0.03% max 316L 16-18% 10-14% 2-3% - 0.10% 0.03% max 2205 22% Avg 5% Avg 3% Avg - 0.14% Avg 0.03% max AL6XN 20-22% 23-25% 6-7% 0.75% max 0.22% Avg 0.03% max

Steel Type Summary of Alloy Compositions Alloy Cr Ni Mo Cu N C 304L 18-20% 8-12% - - 0.10% max 0.03% max 316L 16-18% 10-14% 2-3% - 0.10% 0.03% max 2205 22% Avg 5% Avg 3% Avg - 0.14% Avg 0.03% max AL6XN 20-22% 23-25% 6-7% 0.75% max 0.22% Avg 0.03% max Material selection is typically the buyer s responsibility

Different Alloy Visually Indistinguishable Buyer s Protection Material specifications Material certifications X-Ray Fluorescence (XRF) guns are used for nondestructive testing and separate alloys by elemental composition

CHAPTER II PROTECTING YOUR INVESTMENT

1 Readying New Equipment for Use Removal of Atypical Soils Manufacturing oils What? 3 4 Used for lubrication is polishing and machining operations 5 How? 6 Degreasers and other solvents Detergents 7 Elbow grease 8 9 10 11 12

1 Readying New Equipment for Use Removal of Atypical Soils Manufacturing oils Adhesive residues What? 3 4 Used to secure protective films to stainless steel during manufacturing How? 5 6 Degreasers and other solvents Detergents 7 Elbow grease 8 9 10 11 12

1 Readying New Equipment for Use Removal of Atypical Soils What? 3 4 Manufacturing oils Brake dust (rich in iron) Adhesive residues Oils Road grime Salt Dirt 5 6 7 How? Degreasers and other solvents Detergents Salt binding compounds Iron chelating compounds 8 9 10 11 12

1 Readying New Equipment for Use Removal of Atypical Soils Manufacturing oils Adhesive residues Road grime Free Iron What? 4 Iron that is not part of the crystalline matrix of stainless steel 5 Can come from tools, carbon steel dust and contaminated grinding abrasives 6 7 How? 3 Iron chelating compounds 8 Passivating acids, such as nitric and citric acid 9 10 11 12

1 Readying New Equipment for Use Removal of Atypical Soils Manufacturing oils Adhesive residues Road grime Free Iron 3 4 5 6 7 8 9 10 11 12

1 The Invisible Force 3 4 5 6 7 8 9 10 11 12

The Invisible Force is Real! 1 3 4 5 6 7 8 9 10 11 12

The Invisible Force is Real! 1 3 4 5 6 7 8 9 10 11 12

Vacuum Defined External pressure > Internal Pressure

Vacuum Defined External pressure > Internal Pressure This Sucks!

Common Causes of Vacuum Pumping out of an unvented vessel or accidentally draining an unvented vessel

Common Causes of Vacuum Pumping out of an unvented vessel or accidentally draining an unvented vessel Note that vessel vents can become obstructed!

Common Causes of Vacuum Pumping out of an unvented vessel or accidentally draining an unvented vessel

Common Causes of Vacuum Pumping out of an unvented vessel or accidentally draining an unvented vessel Overfilling a vessel without a siphon breaker really?

Tank Overfilling Question: While filling a tank, beer begins overflowing from the vent line. What do you do?

Tank Overfilling Possible Actions: Shut the inlet valve

Tank Overfilling Possible Actions: Shut the inlet valve Turn off the supply pump

Tank Overfilling Possible Actions: Shut the inlet valve Turn off the supply pump Shut the overflow/vent line valve

Tank Overfilling Possible Actions: Shut the inlet valve Turn off the supply pump Shut the overflow/vent line valve Close all valves and turn off supply pump

Tank Overfilling Possible Actions: Shut the inlet valve Turn off the supply pump Shut the overflow/vent line valve Close all valves and turn off supply pump Grab a pitcher to prevent beer loss

Tank Overfilling Possible Actions: Shut the inlet valve Turn off the supply pump Shut the overflow/vent line valve Close all valves and turn off supply pump These actions can all lead to a siphon if not performed properly

Tank Overfilling This is what happens if you simply stop liquid supply

Tank Overfilling This is what happens if you simply stop liquid supply

Tank Overfilling This is what happens if you simply stop liquid supply

Tank Overfilling This is what happens if you simply stop liquid supply

Common Causes of Vacuum Pumping out of an unvented vessel or accidentally draining an unvented vessel Overfilling a vessel without a siphon breaker really? Spraying caustic into a CO2 atmosphere

Caustic & Carbon Dioxide CO2(g) + NaOH(l) CO2(g) NaHCO3(s) NaOH(l)

Caustic & Carbon Dioxide CO2(g) + NaOH(l) NaHCO3(s)

Caustic & Carbon Dioxide CO2(g) + NaOH(l) NaHCO3(s)

Common Causes of Vacuum Pumping out of an unvented vessel or accidentally draining an unvented vessel Overfilling a vessel without a siphon breaker really? Spraying caustic into a CO2 atmosphere Hot CIP followed by cold rinse

When Hot Meets Cold

When Hot Meets Cold

Real-World Examples

Real-World Examples

Real-World Examples

Preventing Vacuum-Related Failure 1. Installation of properly sized vacuum relief valves. Attention must be paid to the worst-case scenario when selecting relief valves and all possibilities need to be considered. Free-draining is often considered to be the worst case for sizing purposes Hot cleaning followed by ambient/cold rinse typically is more extreme than freedraining KNOW YOUR PROCESS!

Vacuum Relief Valve Types What? Spring type valve Combination pressure and vacuum relief or vacuum-only designs Notes May have relatively high vacuum relief pressure with respect to tank design, especially for larger tanks Limited gas flow due to size, and most useful for smaller vessels Cleaning actuators not available

Vacuum Relief Valve Types What? Rupture Disk Combination pressure and vacuum relief (dual acting) or vacuum-only designs Notes When these devices act they vent the vessel to atmosphere and do not re-seat Burst disk indicators flag alarms about the condition

Vacuum Relief Valve Types What? Weight-loaded vacuum relief valve Notes Available with varying and quite low vacuum pressures (easy to open) Available in a range of sizes up to 400 mm (~16 ) Cleaning actuators available Heating inserts available Can equip with proximity sensors to flag alarms

Preventing Vacuum-Related Failure 1. Installation of properly sized vacuum relief valves. Attention must be paid to the worst-case scenario when selecting relief valves and all possibilities need to be considered. 2. Maintaining and inspecting vacuum relief valves, vents and overflows. Vent line with heat tracing on milk silo

Preventing Vacuum-Related Failure 1. Installation of properly sized vacuum relief valves. Attention must be paid to the worst-case scenario when selecting relief valves and all possibilities need to be considered. 2. Maintaining and inspecting vacuum relief valves, vents and overflows. Vent line with heat tracing on milk silo Caution Convenient location can cause problems when rapid vacuum occurs!

Preventing Vacuum-Related Failure 1. Installation of properly sized vacuum relief valves. Attention must be paid to the worst-case scenario when selecting relief valves and all possibilities need to be considered. 2. Maintaining and inspecting vacuum relief valves, vents and overflows. 3. Proper training to correctly respond to atypical events, such as tank over-filling.

Preventing Vacuum-Related Failure 1. Installation of properly sized vacuum relief valves. Attention must be paid to the worst-case scenario when selecting relief valves and all possibilities need to be considered. 2. Maintaining and inspecting vacuum relief valves, vents and overflows. 3. Proper training to correctly respond to atypical events, such as tank over-filling. 4. Implementation of procedures consistent with process.

Take Home Messages 1. Select stainless steel material type with the same care used when choosing your brewing materials.

Take Home Messages 2. Prepare new equipment for use by removing atypical soils.

Take Home Messages 3. Recognize and respect the invisible force!

Thank You for the Opportunity!

Contact Information Ashton Lewis Brewery Product Manager Paul Mueller Company Springfield, MO alewis@muel.com (417) 830-2337