ION7300 Series Revenue Meter

Similar documents
PowerLogic ION Setup Meter Configuration Software Configuration Guide

PowerLogic Branch Circuit Power Meter (BCPM)

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Planning Elevator Relay Groups Programming Millenium for Windows Software

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

APC BC300 Series 40kW 208/450/480V User Guide

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

Added password for IP setup page : Password must be in IP format!

Installation, Operating and Maintenance Manual

PowerLogic PM5500 series User manual

Ceiec Electric Technology

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Tachometer/Hourmeter/Trip. Installation and Operation Manual

D-TECT 2 IP. GJD230 IP Motion Detector

Installation Guide. ECL Comfort 210, application A Table of Contents

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Instruction Bulletin

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

FCR 05, FCR 07. Power factor correction controller. User and service manual

Veritas Appliance Hardware Service Procedure

Intelligent metering and control devices. Typical applications. Features. Measure and control energy costs. Improve power quality and reliability

EL-OEM-3 OEM Packaged Voltage Data Logger

D-TECT 3 IP. GJD260 IP Motion Detector

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Installation Instructions

Model 4001 Series Single Channel Controller

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Installation Guide for models:

Installation Instructions

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Installation Instructions

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Installation Guide for models:

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

RSMFM-2R MULTIFUNCTIONAL

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

DKG-108 POWER FACTOR CONTROLLER

Rev Pulse Modulating and Anti- Sweat Control (PMAC II Solo) Installation and Operation Manual

EXPERT TRI-STAR. Temperature controller. User s Manual

NetSure -48 VDC Power System

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Power Supply Display Module PSDM. Installation and Operation Manual

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

DMFPM-2R MULTIFUNCTIONAL

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Veritas Appliance Hardware Service Procedure

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Knight Trak II Instruction Manual

IDP-Zone-6 Six Zone Interface Module

OVEN INDUSTRIES, INC.

Option M16.x Configurable I/O extension cards, four multi-inputs (4-20 ma/0-5 V/Pt100) Description of option Functional description

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Mark 25 Ultrapure Water Conductivity Analyzer

Beacon 410A Gas Monitor Operator s Manual

PERMACONN PM1030 Includes DI300. Installation Manual

Installation Guide. ECL Comfort 310, application A Table of Contents

EL-OEM-3 OEM Packaged Voltage Data Logger

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

CT2 Retro Box Installation Instruction Manual

ADT Pulse Mobile App Nest Thermostat

03.03.mmm REV.2 09/01

RTO. User guide 05/

Installation & Maintenance Instructions KAPTIV ZERO AIR LOSS CONDENSATE DRAIN 04/08

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Alarm Tone Generator Model AG17

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

THX-DL Data Logger USER & INSTALLATION MANUAL V

Multi-utility pulse concentrator

FLOW CONTROLLER TYPE S/601

PRO SERIES IMPORTANT SAFETY INFORMATION

IndigoVision Alarm Panel. User Guide

3M Benchtop Air Ionizer 963E. User s Guide

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Installation and Maintenance Manual IM 1038

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

Chargebuster Overhead Ionizer Installation, Operation and Maintenance

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Ethernet General Purpose

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Bench Top Ionizer Installation, Operation and Maintenance

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Class A and Expansion NAC Modules Installation Instructions

Installation Instructions

Electro-Sentry. Users Manual

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

B SERIES ELECTRIC FURNACE

Transcription:

70052-0180-01 PRODUCT OPTION 09/2006 ION7300 Series Revenue Meter This document provides an overview of the PowerLogic ION7300 series revenue meter. In This Document Introduction................................................ 2 Revenue Meter Models................................................. 2 Revenue Meter Installation.............................................. 2 Terminal Cover Installation (OFGEM meters)............................. 2 Differences Between Standard and Revenue Models................... 3 Revenue Meter Energy Register Labels................................... 3 Additional Revenue Metering Modules (RMICAN meters).................. 3 Security Mechanisms................................................... 3 Anti Tamper Seals..................................................... 4 Password Protected Min/Max Register Resets............................. 5 Hardware based Security............................................... 5 Configuring the Revenue Meter.................................. 6 Before Disassembling the Meter......................................... 6 Inserting the Key...................................................... 6 CT & PT Selection..................................................... 7 Additional Information ION7300 Series Installation Guide ION7300 Series User s Guide Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 2006 Schneider Electric. All rights reserved. www.powerlogic.com

Introduction ION7300 Series Revenue Meter Option Introduction A revenue meter provides measurements that pass industry standards for accuracy over a defined range of operating conditions. They also ensure adequate protection against unauthorized alteration of these measured quantities. International and national standards define industry accepted accuracy limits while national and utility based standards regulate protection against unauthorized alteration of measurements. Revenue Meter Models Four revenue meter models are available for the ION7300 series; each model is designated by the certification it holds. Security Option Model Certification Achievement Current Inputs Hardware Lock Anti-tamper Sealing Kit 2 RMANSI (unsealed) Complies with the accuracy requirements of the ANSI C12.16 Revenue Metering Standard Provided 3 RMICAN (unsealed) Canadian Revenue Metering Standards Provided 4 RMICAN (sealed) Canadian Revenue Metering Standards Factory Installed 6 OFGEM 1 IEC 60687 Class 0.5 (for 5 Amps nominal) Provided 1 The OFGEM option is only available in the United Kingdom. It comes standard with a terminal cover. Revenue Meter Installation See the ION7300 Series Installation Guide (included with your meter) for instructions. Terminal Cover Installation (OFGEM meters) See the Terminal Cover Retrofit Installation Instructions (included with your meter). Page 2 2006 Schneider Electric. All rights reserved.

ION7300 Series Revenue Meter Option Differences Between Standard and Revenue Models Differences Between Standard and Revenue Models All ION7300 series revenue meters have different energy output register labels in their meter firmware; some also have additional modules for revenue calculations. Revenue Meter Energy Register Labels The revenue and non revenue meters differ in how they label energy flow. Power Provider/Utility Power Consumer LINE LOAD Delivered Imported Received Exported Revenue Model Standard Model The energy labels for kvah, kvarh and kwh are different from the non revenue devices as follows: Revenue Meter Delivered Received Total = Delivered + Received Net = Delivered Received Non-revenue Meter Imported Exported Total = Imported + Exported Net = Imported Exported Security Mechanisms For example, the meter s output register kvarh tot will be kvarh del+rec in the revenue meter model. Additional Revenue Metering Modules (RMICAN meters) There are additional modules incorporated into the template of ION7300 series RMICAN revenue meters. Some of these modules are used in the calculation and logging of both V 2 h and I 2 h (used for transformer and line loss compensation). To meet Government regulations and Utility security requirements, the revenue meter incorporates three types of security systems: traditional anti tamper mechanical seal on the meter base unit 2006 Schneider Electric. All rights reserved. Page 3

Security Mechanisms ION7300 Series Revenue Meter Option password based security system that permits password protected minimum/ maximum resets (for example, Sliding Window Demand reset) hardware based security system that prevents modification of revenue quantities after the meter is sealed Anti-Tamper Seals The ION7300 series revenue meter incorporates one or two sealing cans through which traditional lead/wire seals can be inserted. These seals effectively prevent unauthorized personnel from gaining access to meter internals. Seals are provided with the meter and are installed as follows: 1. Remove the screw from one of the rear panel corner holes. Place the sealing can over the hole and insert the screw back into the hole, through the sealing can. Back of Meter Use any of the four corner holes (see arrows). 2. Insert the ball bearing into the sealing can over the head of the screw. Install the wire through the two holes in the sealing can. 3. Twist the wire and crimp the lead sealing tab onto the wire. Page 4 2006 Schneider Electric. All rights reserved.

ION7300 Series Revenue Meter Option Security Mechanisms Password Protected Min/Max Register Resets The meter front panel incorporates a password that must be entered in order to reset any of the minimum/maximum or peak demand register values. Hardware-based Security The ION7300 series revenue meter is equipped with a comprehensive security system that provides protection against unauthorized alteration or tampering of revenue related quantities. This security system locks all revenue related ION modules, links and setup registers. Basic meter configuration parameters including volts mode, PT ratio, and CT ratio are locked. These locks are enabled at the factory for all sealed revenue meters. Typical values that are protected include: kwh, kvarh, kvah delivered, received, del rec, del+rec kw, kvar, kva Thermal and Sliding Window demand min and max values Digital Outputs controlling the energy pulsing applications All Power system settings, including PT an CT ratios For a list of all the locked modules for your meter, see the ION Device Templates document available from the PowerLogic website at www.powerlogic.com. A two pin jumper block is used to enable and disable the hardware security as described in the next section. 2006 Schneider Electric. All rights reserved. Page 5

Configuring the Revenue Meter ION7300 Series Revenue Meter Option Configuring the Revenue Meter When enabled, the revenue meter security system prevents unauthorized alteration of revenue related quantities. By default, all ION7300 series revenue meters are shipped from the factory with the security system enabled. You can temporarily disable the security to configure your revenue meter. This is done by removing the meter s back plate, and placing a jumper into the meter. Before Disassembling the Meter Before attempting to remove the back plate of the revenue meter, ensure that it is protected against static electricity discharge. To prevent damage to the unit, wear an anti static wrist strap at all times. DANGER During normal operation of an ION7300 series revenue meter, hazardous voltages are present which can cause severe injury or death. These voltages are present on the terminal strips of the device and throughout the connected potential transformer (PT), current transformer (CT), status input, relay, and control power circuits. Installation and servicing should be performed only by qualified, properly trained personnel. 1. Open all PT fuses (or direct voltage input fuses) and close all CT shorting blocks. 2. Turn off all power to the revenue meter and disconnect the Line and Neutral (or DC power) wires from the Supply Power inputs. 3. Disconnect all other wiring (or power off all other circuits) that may present potentially hazardous voltage to the unit, such as connections to the relay outputs. 4. Ensure that all cables still connected to the revenue meter are NOT live. Inserting the Key In order to configure the revenue meter, ensure that adequate safety precautions have been exercised as above. CAUTION The components inside an ION7300 series revenue meter are extremely sensitive to electrostatic discharge. To prevent damage to the unit, always wear an anti-static wrist strap when working inside the unit. Failure to use proper equipment during servicing will void the meter s warranty. 1. Remove the thumbscrews and retainer bars from the unit. 2. Remove the anti tamper wire seal and four screws on the rear panel. 3. Slide out the rear plate of the device to reveal the unit s circuit board panels. 4. Locate the two pin jumper header labeled J1 on the communications card. Page 6 2006 Schneider Electric. All rights reserved.

ION7300 Series Revenue Meter Option Configuring the Revenue Meter Jumper Block 5. Place the jumper block onto the J1 two pin header (this disables the hardware based security). Slide the rear plate back into the device and replace the four screws onto the real panel. Reconnect the meter s power supply. 6. Configure the meter (e.g. Volts mode, PT and CT ratios, Pulse outputs). 7. Disconnect the meter s power supply. 8. Slide the rear plate out and remove the jumper block from the two pin header to re enable the hardware based security. 9. Replace the rear plate and re apply the anti tamper seals. CT & PT Selection Consult your local Revenue Metering authorities to obtain standards for CT and PT selection for revenue metering applications in your region. 2006 Schneider Electric. All rights reserved. Page 7