Paddle Flow Switch. Pressure Control Flow Switch

Similar documents
A.YITE GROUP (Hongkong & Shanghai)

A.YITE GROUP (Hongkong & Shanghai)

Flow Switches. Series VHS, VKS, VH

Analog Room Pressure Monitor RPC Series

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Accuracy by Design Products for the HVAC Professional

product overview ProControl

NEXT PRESSURE GENERATION EXPANSION OF FIRST SENSOR S PRODUCT FAMILIES

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Temperature controllers TW, TO and TP, Speedy Therm

QD6310. Fixed Gas Detector Operation Manual

Model D12-IR. Digital Gas Transmitter...

TA-Compact-P. Giving you MORE by giving you LESS

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

IS Series Pressure Sensing Switches

1592P01. for liquids in piping DN

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

OEM Sensors for HVAC manufacturers Pool water

Models TX-KE and TX-KP Toxic Gas Transmitters

Electronic Flow Switches

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Electronic Pressure Digest. Pressure and Temperature Transmitters

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Beck. The differential pressure transmitter for air

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

号 PRODUCTORS CATALOGUE. ChengDu SAND Electronic Co. Ltd

Sensors and Switches in Commercial Traction Elevators

QVE1901U Flow Switch. Technical Instructions Document No September 20, Description. Features. Application.

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Application Alley. Utility Meters - Reed Sensor. Utility Meters Use Reed Sensors To Measure Water Flow, Gas and Electricity PARTNER SOLVE DELIVER

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy

2-wire Passive Intelligent Loop (LED) Display Meter

Duct and Rough Service Carbon Monoxide Sensor

ProRadiant Controls, Valves and Actuators

Product Training Module: Digital Pressure Sensors with CANopen Model DPS

HERZ Differential Pressure Control Valve 4002

Air Check EX LEL Gas Monitor Instruction Manual

FSW300 Series Flow Switch

KOBOLD PSR/PS FLOW SWITCH

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

2-wire Passive Intelligent Loop (LED) Display Meter

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SELECTION GUIDE SELECTION GUIDE. Pressure, Flow & Liquid Level Products for Aerospace & Military Uses

Guide Specification - MasterFormat 2017 Style SECTION FLOW INSTRUMENTS PART 2 PRODUCTS 2.1 SECTION INCLUDES 2.2 ACCEPTABLE MANUFACTURERS

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

INSTALLATION, OPERATION INSTRUCTIONS FOR FLOW SWITCHES 62-9FS & FS

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

HERZ Regulating valve 4002

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

CHILLER. Operator s & Installation Manual

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Features and Benefits

ph Measuring System Start-up and maintenance manual e Contents

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

NQ Series Portable Chillers

Hand Held Welding Guns

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

Sitron s CF Line of Flow Switch Monitors

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

aquaconcept Cold water

Using the DewTrak II Dew Point/ Humidity Transmitter

FCHM Hydromatic Pump Control Module

Azbil introduction 2015

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Flush individual room control for floor heating systems

Industrial cooling systems LT

Fill Point, Level Gauges, and Control Range

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Systems for central heating

Nov 08 PRODUCT SPECIFICATION SHEET

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

OPTIBAR DP 7060 Supplementary Instructions

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SAUTER Valveco compact. A pressure-independent multi-function valve

Dual Pressure Controls

OTC, OTM and OTI Series Options

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Temperature Solutions Line Card

Using the Model 1500 Portable Chilled Mirror Hygrometer

BINDER Scientific Product Catalog

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

Transcription:

Paddle Flow Switch GE-311 Plastic Paddle Flow Switch GE-312 Plastic Flow Switch GE-313 PETF Plastic Flow Switch GE-314 Stainless Steel Flow Switch GE-315 Adjustable Flow Switch GE-316 Brass Paddle Flow Switch GE-317 Brass Flow Switch GE-318 Explosion-Proof Flow Switch Pressure Control Flow Switch GE-511 Adjustable Pressure Control Flow GE-512 Differential Pressure Flow Switch GE-518 Pressure Control Flow Switch GE-519 Plastic Pressure Control Flow GE-921 Air Pressure Control Flow Switch GE-920 Air Pressure Control sensor

GE-311 Small Size Plastic Paddle Flow Switch * Protection Grade IP65 * Media Temperature -20~93 * Output 10A; 125/250V AC * Max Static Pressure 10 Bar *Metering Substances Gas, Water, Oil * Install Position Horizontal or Vertica * Pipe Size DN15, DN20, DN25 *Output: 1A(Max) 250VAC/DC 50W(Max) This products is produced by plastic material, used in Sea Water Heating Systerm, Water Purification Equipment, Welding Equipment, Laser Systerm, to measure or control the flow rate. The Magnet don't stay in the flow, so the magnet will not contact with the rust of the water flow, so could make sure the flow switch will be stability.

GE-312 A.YITE GROUP Plastic Flow Switch GE312 Used in the Water Heating Systerm, Welding Equipment, Laser Systerm, instruments and meters, to measure or control the flow rate. The Magnet don't stay in the flow, so the magnet will not contact with the rust of the water flow, so could make sure the flow switch will be stability. * Protection Grade IP65 * Media Temperature -20~93 * Output 10A; 125/250V AC * Max Static Pressure 10 Bar * Metering Substances Gas, Water, Oil * Install Position Horizontal or Vertical * Pipe Size DN15, DN20, DN25 * Output: 1A(Max) 250VAC/DC 50W(Max) When the flow is 1.8L/min ~~ 2.1L/min, the flow switch is Close When the flow is lower than 1.6L/min, the flow switch is Open.

GE-313 PETF Plastic Flow Switch This products is produced by plastic material with a long paddle, suitable for big pipe, used in SPA Appliance, Sea Water Heating Systerm, Water Purification Equipment, Welding Equipment, Laser Systerm, to measure or control the flow rate. Teflon PETF Plastic Material High Performance in Chemical and Corrosion Environment Special Useful in SPA and Sea Water Appliance Technology Data: * Protection Grade IP65 * Media Temperature -10~100 Cd * Max Static Pressure 10 Bar *Metering Substances Gas, Water, Oil *Output: SPST BMF Magnetic Switch * Max Voltage 3A(50VA) * Max Current 250VAC/DC 50W(Max) Character: * No Pressure Loss * Proven paddle type in compact design, especially for serial applications. * Glass-fibre reinforced plastic ensures high stability * With pipe section or for push-in installation into manifolds of customer fittings * Long-term stable switching point, retreatment of paddle by magnetic force, no spring fatigue * Low Pressure Drop & Anti Corrosion environment to control flow, e.g. Swimmin Poll Heating Pump, Sea Water Pump, Central Heating Water Systerm

GE-314 A.YITE GROUP Stainless Steel Flow Switch 1. Media Temperature : -30~125 C 2. Pressure Loss: 0.01bar at Qmax. 3.Hysteresis depending on switch value, 4.Metering Substances Oil, Water, Gas, Air 5.Max Pressure: 30bar (100bar available) 6.Protection Class: IP65 7.Install Position: Horizontal or Vertical 8. Pipe Size: DN15, DN20, DN25 9. Materials: Stainless Steel Minimum Flow Set Point: 8 Liter per Hour. The body of GE-314 flow switch is Stainless Steel material, used in the Petrochemical Industry, Sewage Treatment, Welding Equipment, Laser Systerm, to measure or control the flow rate. A permanent magnet is installed in the GE-314, it is a high performance permanent magnet. The permanent magnet could control the BMF, the BMF is sealed in the top of GE-314. This switch is stability and precise with simple structure.

GE-315 Target Flow Switch The GE-315 Series Target Water Flow Switch is a new type flow switch, avoilding rust and bad contact by separating the electricity from the liquid. This products totally give up the isolating part for water and electricity by corrugated pipe applied on common target flow switch. When the micro switch is operating, it won t touch with low temperature metal part, so no condensation water, no rust and bad contact, and the Protection Grade up to IP65, it could be applied in corrosive air environment. Adjustable Flow Set Point Character: * Good Repeatability * Low Pressure Loss * Dirt Resistant * Hermetic Separation of Electrical and Hydraulic Components * Easy Adjustment of Switch * Tolerance ±15% of full scal * Media Temperature -30~110C * Average Pressure Loss 0.01bar at Qmax. * Hysteresis depending on switch value * Metering Substances Oil, Water, Gas, Air * Max Pressure 25bar (40bar available) * Protection Grade IP65 * Materials UPVC, Brass or Stainless Steel

GE-316 A.YITE GROUP Brass Paddle Flow Switch GE-316 Paddle Flow Switch is specially designed for the Flow Monitoring of Water Source, Water-Loop Heat Pump Air Conditioning Systems and Heat Pump Water Heater. Instruments operate by a spring-supported paddel with magnetic triggering of a reed switch. * Tolerance ±15% of full scal * Media Temperature -30~110 C * Average Pressure Loss 0.01bar at Qmax. * Hysteresis depending on switch value * Metering Substances Oil, Water, Gas, Air * Max Pressure 25bar (40bar available) * Pipe Size DN10~DN80 * Materials Brass or Stainless Steel Character: * Good repeatability * Low pressure loss * Dirt resistant * Hermetic separation of electrical and hydraulic components * Stress free fixation of switch unit by plastic cap

GE-317 Brass Flow Switch The body of GE-317 flow switch is Brass material, used in Sea Water Heating Systerm, Water Purification Equipment, Welding Equipment, Laser Systerm, to measure or control the flow rate. The Magnet don't stay in the flow, so the magnet will not contact with the rust of the water flow, so could make sure the flow switch will be stability. Special Useful In Water Heating Systerm 1. Media Temperature -20~85 C 2. Average Pressure Loss 0.01bar at Qmax. 3. Max Pressure 1.6M Pa 4. Flow Rate:1.5~30 L/Min 5. Output: 1A(Max) 250VAC/DC 100W(Max) 6. Protection Class IP65 7. Install Position Horizontal or Vertical(The Wire must be top) 8. Materials Brass GE-318 Explosion-Proof Flow Switch 1. Max Pressure: 100Bar 2. Work Temperature: -20~120 C 3. Pipe Size: DN8~DN25 4. Voltage: 5-24V/200mA(AC/DC); 250V/120mA(AC/DC) 5. Material: Stainless Steel

Differential Pressure Control Flow Switch The Differential Pressure Switch is a new type flow switch, when the water flow (differential pressure) in system rises up or falls down to one set value, it will output a warning or sent switch-off signal to automatic control system. And it could also be used to indicate the status of pump or water filter. Accurately Control & Stability No Pressure Loss * Dirt Resistant * Easy Install It could avoid the shortcomings of annual inspection or changing target flow switch for water chiller unit so it could be applied widely in the water protection, status feedback of pump and by-pass control of differential pressure in evaporator and condenser in medium and large sized water chiller unit.

A.YITE GROUP * Protection Grade IP54 * Media Temperature -20~93 C * Environmental Temperature -20~71 C * Max Voltage 250V AC * Max Current 3A * Max Static Pressure 10/16/20 Bar * Metering Substances Oil, Water, Air * Max Pressure 25bar (30bar Available) * Main Materials Brass or Stainless Steel GE-511 Differential Pressure Flow Switch with Adjustable Set Point GE-511A Series is D-P Flow Switch with single adjustable setpoint. The adjustable differential pressure switch could be calibrated directly by manufacturer according to customer s requirement, and printed the calibrated value on the label of product, so user needs not readjust in the field. The customer could calibrate by professional instrument according to the differential pressure required by equipment, and A.YITE COMPANY could provide relevant service. Type Pressure Setpoint Switching Differential Range Set To Output GE-511A030 5~30k Pa 3k Pa 1 3A SPDT GE-511A070 6~70k Pa 5k Pa 1 3A SPDT GE-511A100 6~100k Pa 6k Pa 1 3A SPDT GE-511A200 10~200k Pa 10k Pa 1 3A SPDT GE-511A300 20~300k Pa 15k Pa 1 3A SPDT GE-511B Series is D-P Flow Switch with 2 adjustable setpoint. In order to meet various requirements of customers, A.YITE COMPANY also developed the adjustable double setpoints DP switch for upper-lower limit control of differential pressure. And if choose the local indicator, it could be applied to control the water cooled evaporator and condenser in HVAC system, the more or less flow of other heat exchanger, and low flow of heat exchanger due to scaling or dirty jamming, which has incomparable advantages than target flow switch. Type Pressure Setpoint Range Switching Differential P1 P2 Set To P1 Set to P2 Output GE-511B030 5~30k Pa 6~100k Pa 3 k Pa 6 k Pa 2 3A SPDT GE-511B070 6~70k Pa 6~100k Pa 5 k Pa 6 k Pa 2 3A SPDT GE-511B100 6~100k Pa 6~100k Pa 6 k Pa 6 k Pa 2 3A SPDT GE-511B150 6~100k Pa 10~200k Pa 6 k Pa 10 k Pa 2 3A SPDT GE-511B200 10~200k Pa 10~200k Pa 10 k Pa 10 k Pa 2 3A SPDT GE-511B300 20~300k Pa 20~300k Pa 15 k Pa 15 k Pa 2 3A SPDT

* Stable * Accuracy Control * No Pressure Loss * Dirt Resistant * Easy Adjustment of Switch * Easy Install A.YITE GROUP Monitor The Working Condition of Pump * Protection Grade IP54 * Medium Temperature -20~93 C * Environmental Temperature -20~71 C * Output: 10A; 125/250V AC * Metering Substances Oil, Water, Air * Max Pressure 25bar (30bar Available) * Main Materials Brass l * Cable 1.5m, 2 0.5mm2 GE-512 Differential Pressure Flow Switch With Fixed Pressure Set Point GE-512 Series is Differential Pressure Switch with Fixed Pressure Setpoint, the setpoint could not be changed. So if the user choose one type of GE-512, the user could not change the flow setpoint, then it will avoid the mistake in Installing.

Type Pressure Setpoint Swithing Differential Set To Output Cable GE-512006 6 K Pa 1.5 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512010 10 K Pa 2 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512014 14 K Pa 3 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512017 17 K Pa 4 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512020 20 K Pa 5 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512025 25K Pa 6 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512030 30 K Pa 7 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512035 35 K Pa 8 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512040 40 K Pa 8 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512050 50 K Pa 10 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512065 65K Pa 10 K Pa 1 10A SPDT 2~3 0.75mm 2 GE-512080 80 K Pa 10 K Pa 1 10A SPDT 2~3 0.75mm 2 New Products * Protection Grade IP54 * Medium Temperature -20~93 C * Environmental Temperature -20~71 C * Output: SPST 5A(Max) 125/250V AC * Metering Substances Oil, Water * Max Pressure 20bar (30bar Available) * Main Materials Brass l * Cable 1.5m, 2 0.5mm2 GE-518 Differential Pressure Control Flow Switch

* Easy Install * Sensitive * Dirt Resistant * No Pressure Loss * Connect with female thread * Fixed Pressure Setpoint, the setpoint could not be changed New Products * Medium Temperature: -20~93 C * Diaphragm: EPDM * Max Static Pressure: 10 bar * Output: 10A 250VAC SPDT switch * Metering Substances Oil, Water, Sea water * Main Materials Plastic GE-519 Plastic Pressure Control Flow Switch It is a plastic body, as a differential pressure switch, used in water heating systerm. It is a better Substitute Products for common target flow switch, as it is stable performance and low price.

GE921 Air Differential Pressure Switch Series of GE921 Air Differential Pressure Switch can be used to sense (differential) pressure and flow of air in ducts and pipes. Technical * Max. differential pressure: 5000Pa * Protection Class: IP54 * Output: 1.0A (0.4A)/ 250VAC * Working temperature:-20~85 C * Storage temperature: -40~85C * Min. Actuating pressure: 20Pa(Standard); * min.starting interval: 10Pa; range: 20~30Pa * Installation Direction: vertical (standard installation style) * Hose connection: pipe P6.2mm Type Adjust Range Return Difference Deviation GE921A 20~200 Pa 10 Pa ± 10% GE921B 40~100 Pa 20 Pa ± 10% GE921C 40~200 Pa 20 Pa ± 10% GE921D 50~500 Pa 20 Pa ± 10% GE921E 200~1000 Pa 100 Pa ± 10% GE921F 500~2500 Pa 150 Pa ± 10% GE921G 1000~54000 Pa 200 Pa ± 10% Possible fields of application include: * Monitoring air filters and ventilators * Monitoring industrial cooling-air circuits * Maximum air flow controller for variable air volume systems * Overheating protection for fan heaters * Monitoring flows in ventilation ducts * Controlling air and fire-protection flaps * Frost protection for heat exchangers * Air proving in ventilation ducts

GE920 Air Differential Pressure Transmitter GE920 Differential Pressure Transmitter is Adopting diffused silicon chip measuring technology, with double seal pressure piping and exact differential pressure measuring. It is suitable for differential pressure measuring for medical treatment, chemical fiber, electricity, dustless house and etc. Ranges: 0~50Pa~200Pa~1KPa~10KPa ~100KPa ±(50Pa~200Pa~1KPa~10KPa ~100KPa) Accuracy:0.1%, 0.5%FS, 1.0%FS Output: 0~5V; 1~5V; 4~20mA Power supply:12vdc~36vdc(24vdc is Standard) Medium Temperature: -20~85 C Typical applications include: Filter obstructive alarm. Maximum air flow controller for variable air volume systems. Air proving in ventilation ducts. Burner air control Overheating protection for Electric Heater with Blower