Instruction manual. W440 AIS Sart Sniffer

Similar documents
4 & 8-POINT ANNUNCIATORS Instruction Manual

Electronic Emergency Telegraph. TG-1 and TG-1A

Technical Manual. Level Alarm Unit CARLA & WIDS

Instructions manual. By-alarm. By-alarm Manager software

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

USER MANUAL FOR OPERATING SYSTEM

21-light Remote Annunciator. Owner s Manual

Contents. Glossary

RS485 MODBUS Module 8AI

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

SACE PR021/K SIGNALLING UNIT

FEC400 Series. Installation Manual

Version 1.03 January-2002 USER S MANUAL

Combi B Alarm box. Mounting instructions

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

20 Light Remote Annunciator

UNC100 Integra Manual

BSR Addressable Fire Detection control panel. Installation operation manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Fume Hood Operating Display Panel

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

Intelligent Security & Fire Ltd

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

ESP TECHNOLOGIES LIMITED

Alarm system For oil-water separator

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Model A1700 Series Annunciator

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

CTT8 TEMPERATURE MONITOR DEVICE

RTD TEMPERATURE SENSING SYSTEM

Independent Zone Control (I.Z.C.)

QA16 Addressable System

Table of Contents SECTION PAGE

Premier Hazard STC Instructions

Battery control panel BCP-136

GPS Evaluation Kit EVA1037/1080

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Control Panels and Fire Detection Equipment

P2267 NETWORK INTERFACE

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

ECO N DATE DESCRIPTION OF CHANGE CHG

SC-F3G User Manual 1.0

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

How to use the BTRM in Remote Enclosures

MO n : 12JMC rév A

HRX Technical Manual. Version 1.2

reading carefully this guide, operating this system strictly on the standard procedure. System 816

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

Consultant Specification AGILE Wireless Fire Detection System

IDS816 User Manual H Issued January 2009

Wireless Keypads LKP(E)S8M Series

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

AES IntelliTAP. Model 7068 Digital Dialer Interface A Supplemental Alarm Reporting Device. Version Installation Guide CONTENTS

ZLM4 OEM Technical Manual

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

GLOBAL. InstallatIon & operation manual

Intelligent addressable fire alarm control panel

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

Model A2100 Series Annunciator

SECURIT 700L PLUS ENGINEERING MANUAL

IP & SMS Alarm Communicator

Pioneer-R16 Gas Monitor Operator s Manual

Essentia Project Artica Platform No Frost 60 cm Appliances 2011

Wireless Keypad GKP-S8M

USER MANUAL TUNGSTEN SMART-HEAT ELECTRIC WIRELESS DIMMER CONTROLLER BY BROMIC IMPORTANT

Solution 880 Operators Manual. Issue 1.00

SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

Fire / CO Alarm Interface

RMS/RPX Reader. User Manual

NU2 Smart Power Supply (SPS) Manual

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

U ser's Guide PC6010

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Installation and user manual for the BiWire / Conventional Repeater Panel

Electric Release Panel Wiring Tips

The Remote alarm Panel, TYPE RAPv2

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

TCM-2 Thyristor Control Module DATA SHEET

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Transcription:

Instruction manual W440 AIS Sart Sniffer Ed. 1.2.0 () 9/2012

Doc: W440_1_2_0_

1 2 3 Picture 1: Frontal view 4 3

Picture 2: Schematic diagram 4

Warning The crossed rubbish skip symbol indicates that the product should be wasted separately from the other rubbish at the end of its working life and that it cannot be thrown together with domestic rubbish. The user will therefore take the end-life device to the appropriate separate waste centers of electrical and electronic rubbish indicated by local authorities. The proper separate waste of end-life devices for recycling, treatment, environmental compatible disposal, helps avoiding possible negative effects on environment and on health, supporting the re-use and recycle of the materials composing the device. Illegal disposal of the product by the user implies the application of administrative sanctions provided by law. WamBlee and RESCUE-ME are registered trademarks of WamBlee s.r.l 5

Introduction Congratulations and thank you for purchasing the W440 AIS SART Sniffer, one of the most high-tech, reliable devices available on the market. As the owner of this radio device you are advised to: Read this manual. Adopt a schedule check planing. 6

Technical specifications Power supply Consumption Working temperature Storage temperature Relative Humidity < 70% Interface Impedance Speed AIS Sentence From 9 to 30 Volts DC < 0.1 A typical From -20 C a +55 C From -30 C a +70 C NMEA 0183, galvanic isolation > 800 Ohms 38400 baud AIVDM AIS ID in memory Up to 8 Activation Auxiliary switch contact or message Dimension Weight Case material IP protections Installation Rotary knob switch (Optional) 1A 250 VAC Proprietary NMEA sentence DIN 3 module 130 gr. PC (UL94 V-0) IP4X (Case) IP2X (Contact) DIN guide or wall mounting (with accessories) 7

Installation The W440 AIS Sart Sniffer can be installed on DIN guide (standard model) or on wall using an adapter kit (on request). Please note that the W440 is not a waterproof device, and shall be installed on a protected area. After W440 mechanical installation, you can connect the AIS Sart Sniffer using copper wire with almost 0.75 mm 2 size. We suggest to use the schematic diagram on page 4. In detail, as for the wire connector marked as (1) (upper part), please see the following connections : Pin Connection type and function 1 Positive DC power supply (max +30 Volts) 2 Ground or negative 3 Rotary knob switch lamp. 4 C type rotary knob switch contact (spring return) 5 B type rotary knob switch contact (common) 6 A type rotary knob switch contact (ON mode) 7 N.O. relay contact 8 Common relay contact 9 N.C. relay contact 8

In detail, as for the wire connector marked as (4) (lower part), please see the following connections: Pin Connection 1 Ground (NMEA out) 2 NMEA proprietary sentence output 3 Buzzer line 4 +V (for special application) 5 Ground 6 NMEA line (A) 7 NMEA line (B) To the left of the connector are two DIP switches whose function is explained in the chapter "Using the W440 and its programming." For connection to the data output of your receiver use the NMEA two terminals (pin 6 and 7 of the lower connector). This port is capable of accepting a signal according to the standard NMEA 0183 at 38400 baud. On the front of the W440 are two indicator lights (LEDs 2, 3) Here below is the table of their functionality. Led Status Function Green Fixed on Operative Red Fixed on AIS Alert received Red Flashing Speed and communication check during power on 9

Using the W440 and its programming. The W440 control is made through the use of a three-position switch (2 fixed and one spring return). Through the switch you can control the operation of your W440 unit, which will operate in this way: Position (A) = disabled. Position (B) = active device and armed Position (C) = selection mode and reset (with spring return to position B). The W440 unit is also equipped with two DIP switches located to the left of the lower connector (4). Their function is the following: DIP Switch Open Close (On position) 1 The alarm is activated only if the AIS ID recognized code is one of the 8 previously ID programmed in memory. (below the procedure for programming is described). 2 Set the line to be used with a piezo buzzer. The alarm is activated if the AIS received message contains an ID that starts with 970 or 972, regardless of the rest of the code. Set the line to be used with a ON / OFF buzzer (bell or buzzer). 10

How to store the MSLD MOB ID The W440 AIS Sart Sniffer lets you store up to 8 AIS SART codes, so that the alarm is activated only for codes stored (unless this feature is disabled, see the dip switch setting). To store a code (or overwrite), proceed as follows: 1. Move the knob selector in position C and keep it pressed for 5 seconds. 2. The lamp switch will begin to flash at a rate of 1 flash per second; each flash indicates the memory position currently in use (1 flash = position 1, position 2 = 2 flashes, etc.). 3. To change the memory location simply release the switch to its central location for a couple of seconds and repeat the procedure from step 1. The new location will be the next to the previous one. 4. Release the switch back to position B. The luminous body of the switch will continue to flash indicating the selected memory location. 5. Turn on a AIS SART device nearby, make sure the device is activated in MOB TEST mode and IT makes a test transmission (check the instructions in the manual of the manufacturer of the MOB equipment). 6. After a successful transmission and subsequent reception of AIS message, the W440 will indicate acceptance of the new ID code with light on (no flashing) and audible beep by a duration of 2 seconds. 7. The W440 has stored the new code in the AIS position required and your unit is back to the operating mode. How to 'arm' your W400 To ensure that your W440 is ready to receive any alarm you must proceed as follows: 1. Move the knob switch to position B. 11

2. A beep of 1 second and the green LED will indicate the correct power on sequence. 3. The red LED on your device will begin to flash indicating that W440 is in the process of recognition of the serial communication. the AIS receiving device must be turned on, working and able to receive AIS signals. 4. Wait that the device completes the procedure described in item 3. The turning off of the red LED and the turning on of the light on the switch indicate the successful startup. 5. Your W440 unit is now ready to receive alarms. Activation following MOB alert message If an AIS MOB or SART unit able to send a message like 'MOB ACTIVE' or 'SART ACTIVE' is activated in range of your radio equipment, the W440 unit will recognize the NMEA sentence and behave differently depending on the DIP Switch 1 condition. DIP Switch 1 Open Close (or ON) Action If the ID code is present among those stored, the relay contact to the upper connector, position 8 and 7, will move from open to closed. At the same time the lamp in the know switch flashing at 1 second/rate, accompanied by 2 beeps of the buzzer, red and green LEDs will remain on. If the DIP switch 1 is closed and if the received ID code starts with 970 or 972, the relay contact to the upper connector, position 8 and 7, will move from open to closed. At the same time the lamp in the know switch flashing at 1 second/rate, accompanied by 2 beeps of the buzzer, red and green LEDs will remain on. 12

Signalling following TEST MOB message If you receive a message such as 'SART TEST' or 'MOB TEST' (test message), the relay contact will not change. You can ear only a 2 seconds beep, which indicates the receipt of the message. Turning off the alarm and reset To turn off your device W440 or reset an alarm received, simply move the switch in position A. Please note that The programmable ID codes stored in the table remain in memory even turning off the device. NMEA proprietary sentence output The W440 is able to generate a NMEA 0183 sentence (4800 baud) repeated every two seconds. This ruling is as follows: $PWBEE,MOB_SWITCH,ON*<crc> where: ON = as close contact Further clarification on the use of this NMEA sentence can be requested directly to our technical department. Periodic checks It is advisable to check with a certain periodicity (at least once a month) your W440 system, the control can be done using the devices on board AIS MOB TEST mode and check their recognition as described in paragraph "a result of activation MOB alarm message. " 13

Troubleshooting Should the device fail to pass the periodic check it will be necessary to send your W440 to our after-sales service, which will restore proper performance. A list of after-sales authorized dealer to carry out maintenance on your device can be consulted on our website: www.wamblee.it 14

Note 15

Wamblee s.r.l. Via Vittori 19 48018 FAZA (RA) ITALY Tel. +39 0546 623891 / Fax +39 0546 623891 / email:info@wamblee.it Made in Italy 16