Inline Heater for Solvent or Gas. Installation and Operation Manual

Similar documents
Series P3TFMOL Purged, Flouropolymer Chemical Heater

Frontier TM Series Inline Chemical Heater

Quartz H 2 OT SHOT TM. Infrared Inline Chemical Heater

Series TIH TM Fluoropolymer In-Line Chemical Heater

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

FLCH4R Garage and Utility Electric Heater

INSTALLATION, OPERATION AND MAINTENANCE

Installation & Maintenance Instructions

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Installation and Operations Manual

Blade Series Heat Exchanger Operation and Installation

Installation Instructions PP-AS20 Anti-Scale System

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

IMPORTANT INSTRUCTIONS

HotPoly Tote Tank / IBC Heaters (TTH Series)

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

INSTALLATION AND OPERATING MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

OPERATION & INSTALLATION MANUAL

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

DBF 4XL Dryer Booster Fans

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

XT Series Thermostats

OKB, OKD, & OKH Series

INSTALLATION AND OPERATING MANUAL

INSTALLATION AND OPERATING MANUAL

P/N CC-100. Coolant Circulator. Operation manual

HI Industrial Utility Heater HI Soleus Air International

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

VX SERIES Wireless Thermostat with Occupancy Sensor

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG B-AR, B-W SERIES SHELL-ICE MAKER

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

TA-300, TA-300-LF, TA-350, TA-350-LF

TECHNICAL INSTRUCTIONS

Series: MBC1-TC Mini Benchtop Temperature Controller

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

TL-105 COLUMN HEATER

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

CVS Model Inline Multi-Port Ventilators

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

Panel Mounted Heat Exchangers by Dantherm, Inc.

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Design Criteria. Installation

Service Parts, Kits and Accessories

InstructIon Manual KrEs EQuIPMEnt stands

POOL HEATER INSTALLATION, OPERATION AND MAINTENANCE

TORRID MARINE YACHT QUALITY Since Owner s Manual

Electric Space Heater

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

INSTALLATION AND OPERATING MANUAL

Portable Induction Ranges

FW-RA-LED Remote Multiplex Annunciator Panels

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

ion Genesis Pump Controller

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Sauna Craft CTT Heater Installation Manual

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

AeroVent 3X Product Manual

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Duct Mount. Installation Instructions

Installation & Maintenance Instructions

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

SEALING FIBER SEALING COMPOUND

USER S OPERATING AND INSTRUCTION MANUAL

PodView Level Indicator LI40 Series Manual

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

AQUA LOGIC S MULTI-TEMP Water-Cooled Marine Duty Series chiller

R Series B & T2 Model

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

Model OP155 Air Dryer

Transcription:

SH Series Inline Heater for Solvent or Gas Installation and Operation Manual This instruction manual explains the basic operation of the Process Technology inline solvent or gas heater. We recommend reading this manual carefully prior to operating the heater to help ensure proper use of the equipment. Please supply the model and serial numbers when ordering spare parts or when receiving technical assistance. www.processtechnology.com 7010 Lindsay Dr., Mentor, OH 44060 Phone: 440-974-1300 Fax: 440-974-9561 USA/CN: 800-621-1998

Table of Contents Introduction:... 2 Model Explanation... 3 Pre-Installation:... 6 Facility Requirements:... 6 Current Draw And Recommended Power Supply Fusing:... 6 Installation:... 7 Uncrating And Inspection:... 7 Component Identification:... 7 Mounting the Heater Chamber:... 7 Process Connections:... 7 Electrical Connections:... 7 Main Power:... 7 Temperature Sensors and over-temperature control:... 8 Element Over-Temperature Sensors:... 9 Element TCO (Thermal Cutoff):... 9 Start Up Procedures:... 9 Shut-Down Procedure:... 9 Warranty:... 10 1

Introduction: Process Technology s SH In-Line Heater is designed to provide energy-efficient, safe heating of solvents and non-flammable gasses (such as nitrogen). Wetted surfaces of the heater are constructed of chemically milled (etched) 316 stainless steel. The heater is a compact, completely welded, insulated, pressure resistant vessel. It is designed for use in either Single Pass or Multi- Pass Flow applications. The SH In-Line Heater can withstand operation at a variety of temperature and pressure conditions. The maximum operating condition for the SH In-Line Heater is 200 o C at 400 PSI. Safe operation of the equipment requires that each of the temperature sensors be wired properly into a customer supplied control system, in accordance with local regulations, where applicable. Refer to pages 8 and 9 for additional information. Failure to use the supplied temperature sensors for their intended purposes may void all or part of the equipment warranty. Consult factory for technical assistance. The standard SH In-Line Heater consists of: 316 stainless steel fluid path 304 stainless steel, insulated housing Two J- type thermocouple over-temperature sensors Bi-metallic, re-settable temperature fuse Note: The SH heater does not include conduit or conduit fittings. Optional Equipment may include: E or K-type thermocouples Custom inlet and outlet connections If the Chamber Heater is purchased as part of a system, the following equipment may be included. Process Controller Proper fusing and electrical disconnect provisions Note: The process controller is required for safe operation, and must be customersupplied if not purchased from Process Technology. 2

Model Explanation: Provided below is an example of a typical model number along with an explanation of each part. This key will help you understand your model number. Model number example: SH 6-12 1 - SN50 - J 1 - X Heater Series Type. The model number will always begin with the series type of your heater. Heater Revision Level. If the model number contains a letter here, it represents the revision level of the heater. Heater Wattage. The first in the model number will always be the wattage of your heater. The table provided below identifies the standard available wattage ratings of the SH Series Heater. Heater Wattage (W) 2 2,000 3 3,000 4 4,000 6 6,000 9 9,000 12 12,000 18 18,000 Heater Voltage. The next set of up to (2) characters following the heater Wattage will describe the rated Voltage of the heater. Rated Voltage (V) Rated Voltage (V) 1 208 7 440 2 240 8 575 3 380 9 220 4 400 10 200 5 415 12 120 6 480 14 600 3

Model Explanation (continued): SH 6-12 1 - SN50 - J 1 - X Voltage Supply Phase. This character indicates if the required voltage supply is to be single phase or 3 phase. Required Phase 1 Single phase 3 Three phase Process Inlet/Outlet Plumbing Connections. The characters used to describe the plumbing connections signify the type of connection and its size. The heater inlet and outlet plumbing connections are the same type and size. Please refer to the table below to see the specific plumbing connections provided with the heater: Plumbing Connection Type Plumbing Connection Size: mm (in) SN50 tube stub 12mm (1/2-inch) SN75 tube stub 19mm (3/4-inch) V50 Swagelok VCR connection 12mm (1/2-inch) V75 Swagelok VCR connection 19mm (3/4-inch) Heater Over-Temperature Sensor Type. Three heater over-temperature sensor types are available for the Process Technology SH Series Heater. Please refer to the table below for a brief listing of the available options. J K E Over-temperature Sensor Description Type J Thermocouple Type K Thermocouple Type E Thermocouple 4

Model Explanation (continued): SH 6-12 1 - SN50 - J 1 - X Thermal Cutoff (TCO) Type. There are three temperature options available with the Process Technology SH Series heater. Please refer to the table below for a brief listing of the available options. 1 2 3 Description Low temp range - for applications between 50-90 C Medium temp range - for applications between 90-125 C High temp range - for applications between 125-200 C Options. Additional options available with the SH heater are listed at the end of the model number. Please refer to the table below for a brief listing of the available options. Description Blank No Additional Options #### (4 digit number) Mounted in Tytan enclosure with controls 5

Pre-Installation: 1) NEVER exceed recommended temperature and pressure ratings. 2) Turn power off at the main disconnect before performing any service. 3) Lock and Tag the disconnect to prevent the equipment from accidentally being energized during servicing. 4) Read all instructions carefully and understand equipment before operating. Consult factory for assistance if needed. Note: Before installation, carefully read this entire section. Facility Requirements: Note: This SH Heater is suitable for use in Class l, Division 2, Groups A-D. Explosion Hazard Substitution of Components may Impair Suitability for Class l, Division 2. Before installing the SH In-Line Heater, confirm each of the following: 1) Space: The SH In-Line Heater chamber is designed to be mounted vertically or horizontally using the supplied mounting brackets. 2) Mounting: The SH In-Line Heater is supplied with mounting brackets. Ensure that the mounting location will adequately support the weight of the chamber, its supporting hardware and plumbing, and the fluid in the system. When mounted vertically the process outlet must be above the process inlet. 3) Inlet and Outlet Plumbing: The standard SH In-Line Heater is supplied with ½ inch stainless steel tube connections. Refer to Model Explanation on page 4 for the specific inlet/outlet connections supplied with the heater. 4) Electrical: Verify that the incoming power line is rated for the required current draw and is fused correctly. Refer to Model Explanation on pages 3 and 4 for power requirements of the unit delivered. Current Draw And Recommended Power Supply Fusing: Process Technology recommends the SH In-Line Heater be wired per NEC guidelines, latest edition, and according to any additional applicable standards for your installation. 6

Installation: Uncrating And Inspection: 1) The SH In-Line Heater may have been shipped in a horizontal or vertical position. 2) Remove the heater chamber from its shipping container. 3) Remove box containing all support equipment: interconnect cables and tubing, and manual. 4) Remove any protective packaging material and discard. 5) Inspect unit for any apparent physical damage. 6) Check component list for all parts. Component Identification: The following items should be included: 1) Heater Chamber Assembly: Consists of 316 stainless steel fluid path with replaceable resistive heating elements enclosed in an insulated 304 stainless steel chamber. 2) Mounting Hardware: Mounting brackets are included and attach to the top and bottom of the heater chamber. Mounting the Heater Chamber: The SH In-Line Heater requires mounting to a physically capable structure. Mounting brackets are supplied. Specific heating chamber dimensions are shown on the dimensional drawing in the Appendix. Process Connections: 1) Remove the protective plastic caps from inlet and outlet connections of the heater chamber assembly. 2) Connect appropriate fittings to the Inlet and Outlet of the heater chamber assembly. Refer to Model Explanation on page 4 for the specific inlet/outlet connections supplied with the heater. Electrical Connections: Main Power: The SH In-Line Heaters are designed to operate on a variety of voltages and phases. Conduit and all ancillary electrical connection requirements are to be supplied by end user. All electrical connections and safety devices must comply with local electrical code guidelines. Refer to Model Explanation on pages 3 and 4 for the voltage and phase of the unit shipped. 1) Fuse the incoming power supply lines for the rated amperage using an approved electrical disconnect. Process Technology recommends that the electrical disconnect have the following minimum specifications: a) Appropriate voltage and amperage ratings for the specific heating system. Verify that all fused electrical disconnects meet jurisdictional requirements. b) For safety of service and maintenance personnel, this electrical disconnect must be located within sight of the equipment. 7

2) Ensure that all services are off before making electrical and liquid connections. Use only approved and properly rated wire, conduit and connectors. 3) Connect heater leads to an electrical disconnect device in the customer supplied controller. This electrical disconnect must have the proper electrical rating necessary for the equipment. Tighten wire connections to appropriate torque setting, indicated on the electrical component. 4) Connect the green ground lead to the proper electrical earth ground. Check all connections before applying power. Temperature Sensors and over-temperature control: The SH In-Line Heater chamber is equipped with redundant temperature monitoring capabilities to better ensure safe temperature levels. These sensors must be installed into a customer-supplied control package to protect the equipment from accidental damage and to ensure operator safety. Refer to Model Explanation on pages 4 and 5 for the specific temperature sensors supplied with the heater. Note: Failure to use the supplied sensors for their intended purposes may void all or part of the equipment warranty. Consult Process Technology for technical assistance. Process Fluid Control Sensor (only included with temperature control system): The Process Control Temperature Sensor measures the temperature of the process fluid exiting the heater chamber. This sensor is intended to be used as the primary control input for the process temperature controller. It is recommended that this sensor be used as the primary input for process control. However, in the event an external sensor is used to control the heater, locate the sensor as close to the process fluid outlet as possible. Ensure proper function of the heater s over-temperature sensors. The secondary Process Temperature Sensor (if included) may be used for over-temperature control of the process fluid. 8

Element Over-Temperature Sensors: The Element Over-Temperature measures the operating temperature of the heating element. Refer to Model Explanation on page 4 for the specific sensor included with the heater. Activation of the element over-temperature sensor must be wired to disable the heater and require manual reset to re-enable heating. Element TCO (Thermal Cutoff): The TCO must be connected to interrupt the operation of the control circuit if it is activated by element over-temperature. Refer to Model Explanation on page 5 for the specific sensor included with the heater. Activation of the over-temperature protection should require manual reset to enable heating. Do not connect the TCO in series with the heating element/main load. The TCO is designed to be wired into the heater s control circuit, connected in series with the coil of the magnetic contactor for the main load. Do not attempt to replace the thermal cut off device. Contact Process Technology for assistance. Start Up Procedures: 1) Initiate process flow. 2) Energize heater control and ensure proper setting of control and over-temperature setpoints. 3) Engage control to energize heater. Shut-Down Procedure: The heater unit may contain residual process fluid. This residual should be handled with the same care and precautions as any process chemical. 1) Turn off heater control. Maintain process fluid flow. 2) Allow heater to cool to within near ambient inlet fluid temperature before stopping flow. 9

WARRANTY: All PROCESS TECHNOLOGY equipment, heaters and controls have been carefully inspected before shipping and are warranted to be free from defects in workmanship and materials for a period of one year from date of purchase on a pro-rated basis. At its option, PROCESS TECHNOLOGY will repair or replace any defects that are exhibited under proper and normal use. PROCESS TECHNOLOGY disclaims any responsibility for misuse, misapplication, negligence or improper installation of equipment, tempering or other operating conditions that are beyond its control (such as excessively high or low purge gas supply pressure). PROCESS TECHNOLOGY makes no warranty or representation regarding the fitness for use or the application of its products by the customer. All products and components not manufactured by PROCESS TECHNOLOGY will carry the original manufacturer's warranty, copies of which are available upon request. PROCESS TECHNOLOGY makes no warranty or representation, expressed or implied, with respect to the products not manufactured by PROCESS TECHNOLOGY. Products must be installed and maintained in accordance with PROCESS TECHNOLOGY instructions. PROCESS TECHNOLOGY is not liable for labor costs incurred in removal, reinstallation, or unauthorized repair of the product or for damage of any type including incidental or consequential damage. PROCESS TECHNOLOGY neither assumes nor authorizes any representative of PROCESS TECHNOLOGY or any other person to assume for it any other liabilities in connection with the sale of the products. This warranty may not be verbally changed or modified by any representative of PROCESS TECHNOLOGY. Shipping Damages: Claims against freight carriers for damage in transit must be filed by the customer at the time of delivery or as soon as possible. Returns: No product shall be returned to PROCESS TECHNOLOGY without first obtaining a return material authorization (RMA) number from a PROCESS TECHNOLOGY representative. All returns must be freight prepaid. Freight collect or shipments without authorization will be refused. Information: PROCESS TECHNOLOGY will endeavor to furnish such advice as it may be able to supply with reference to the use by buyer of any material purchased, but PROCESS TECHNOLOGY makes no guarantees and assumes no obligation or liability for advice given verbally or in print or the results obtained. Buyer assumes all risk and liability that may result from the use of any material, whether used by itself or in combination with other products. No suggestion for product use shall be construed as a recommendation for its use in infringement on any existing patent. Conflict Between Documents: Acceptance of this offer is expressly conditioned upon agreement to all terms and conditions contained herein. In the event of a conflict between the terms and conditions of purchaser's purchase order, and PROCESS TECHNOLOGY s terms and conditions, proposal or offer, the latter shall govern. 10