Speakers and Speaker Strobes

Similar documents
Wheelock RSS & RSSP Series

s Notification Appliances

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Conventional Smoke Detectors KFAPO

SP40S-D. Kingfisher Company, inc. Features: Description:

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

Multiple Input and Output Modules

SELECT-A-HORN/STROBE SERIES

TrueAlert Notification Appliances

TrueAlert Multi-Candela Notification Appliances

Life safety notification

'08 Series Notification A liances

Autonomous control unit

L-Series, Emergency Communication Devices

SAFEPATH SAFEPATH. Emergency communications system

Analog fire panels FPA-1000 Family

TrueAlert Multi-Candela Notification Appliances

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

L-Series, Indoor Strobes and Horn Strobes

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

TrueAlert Addressable Notification Appliances

L-Series, Indoor Strobes and Horn Strobes

UL Online Certifications Directory

CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

*15cd models are Listed at 15cd and meet 75cd on axis

TrueAlert ES Addressable Notification Appliances

Protect. Alert. Inform.

SAFEPATH Mass Notification System (SPMNS)

1. POWERPATH Operation

Field Configurable Horns and Strobes

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

Figure 1. Figure 2. See notes 1 and 2 below.

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Genesis LED G1 Series

Potter Wall Mount Select-A-Strobe

TrueAlert Addressable Notification Appliances

Field Configurable Horns and Strobes

SAFEPATH DoD facility communications system & expansion options

Selectable Output Chimes and Chime/Strobes

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

July 14, 1999 DF C-100.

SECTION FIRE ALARM SYSTEMS

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

UL Online Certifications Directory

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.)

June 10, 2002 DF C S2424

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Frequently Asked Questions

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

D7053. Installation Instructions Multiplex Input/Output Module

TrueAlert Addressable Notification Appliances

D7052. Installation Instructions Multiplex Dual Input Module

D7044. Installation Instructions Multiplex Single Input Module

AL800ULADA. NAC Power Extender. Installation Guide

INSTALLATION INSTRUCTIONS TALKBACK MODULE

The Advance You ve Been Looking For

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

Addressable Fire Alarm Control Panel

ECC-50/100C. Emergency Command Center

University Design Standard Fire Alarm Systems

* These Remote Mics must be SPRM-GP

LifeAlarm Fire Alarm Controls

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Series DV-100 VoiceLink Operation and Installation Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

SECTION ADDRESSABLE FIRE ALARM SYSTEM

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

Performance Based Design: Fire Alarm Visual Notification Appliances - Mathematical Guide. Ernesto Vega Jánica, EE, MSc, MEng

TrueAlarm ES Analog Sensing

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

TrueAlert Addressable Notification Appliances

RELEASE DEVICE CONTROLS

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

Hazardous Location Supervised Warning Light

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

Opal TM AV Devices. Data Sheet. Benefits

SAFEPATH Operation and Installation Manual

MANUAL RESET ALARM RELEASE BOX

Horn/Strobe Compliance Reference Guide

Booster Power Supply Manual

Signature Series Auto-Sync Output Module (CC1S)

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Dimensions of the Optional Mounting Box (BB-400R/W)

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

A COMPARISON OF FIRE ALARM SYSTEM REQUIREMENTS IN THE US AND UK. James R. Lugar Jr., P.E. Rolf Jensen & Associates, Inc. SFPE 2012 Savannah, GA

MANUAL RESET ALARM RELEASE

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

Transcription:

Kingfisher Company, inc. Speakers and Speaker Strobes Features: Approvals include: UL Standard 1971, UL Standard 1480, New York City (MEA), California State Fire Marshall (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant Meets OSHA 29 Part 1910.165 Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi Candela models) or 1575cd (Single Candela model) Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (multi candela models) Strobes produce 1 flash per second over the regulated voltage range 24 VDC with wide UL Regulated Voltage using filtered DC or unfiltered VRMS input voltage Synchronize with sync modules or panels with built-in Kingfisher Company, inc., Patented Sync Protocol Field selectable taps for 25 or 70 VRMS operation from Description: The Kingfisher Company, inc., high performance Series KFET Speakers and Series KFET Speaker Strobes provide high audio output, clear audibility, dual voltage (25/70 VRMS) capability and field selectable taps from 1/8 to 8 watts. They are designed to meet the critical needs of the life safety industry for effective emergency voice communications, tone signaling and visible signaling to alert the hearing impaired. The low profile design incorporates a speaker mounting plate for faster and easier installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. The Series KFET Speaker Strobe models incorporate Low Current draw Series KFRSS Strobes. Strobe options for wall mount models include 15/75 cd or Kingfisher Company, inc. s patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all Series KFET Strobes may be synchronized when using the Kingfisher Company, inc., KFSM, KFDSM Sync Modules, King-Fisher Company, inc., NAC 10 Power Supply or other manufacturers panels incorporating the King-Fisher Company, inc., Patented Sync Protocol. Kingfisher Company, inc., synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy. Series KFET70 and KFET90 Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with

Description Continued: Series KFET70 and KFET90 Speaker Strobes are UL Listed for indoor use under Standard 1971 (Signaling Devices for the Hearing Impaired) and Standard 1480 (Speaker Appliances), and use a Xenon flashtube with solid state circuitry enclosed in a rugged Lexan lens to provide maximum reliability for effective visual signaling. All inputs are supervised and employ IN/OUT wiring terminals for fast installation using #12 to #18 AWG wiring. Color options for Series KFET speakers and speaker strobes are red, white, or nickel plated. Specifications: WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. CONTACT KING-FISHER COMPANY, inc., FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COM- PLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Table 1: UL Max Current* KFET70/ KFET90 Speaker Strobes KFET70 Strobe current - Wall Mount KFET90 Strobe current - Ceiling Mount 241575W 24MCW 24MCWH 24MCC 24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 16-33 VDC 0.090 0.060 0.092 0.16 5 0.220 0.300 0.420 0.065 0.105 0.18 9 0.24 9 0.300 0.420 Table 2: KFET70/KFET90 UL Reverberant dba @ 10 Feet** watts 1/8 1/4 1/2 1 2 4 8 ET Speaker 75.0 78.0 81.0 84.0 87.0 90.0 93.0 ET Speaker Strobe 75.0 78.0 81.0 84.0 87.0 90.0 93.0 *UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. **dba ratings are based on UL testing under UL Standard 1480 Kingfisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 2

Model Wall Mount Ceiling Mount Non- Sync Strobe Sync w/ SM, DSM or PS- 12/24-8CP/ MP Strobe Can-dela # Model Color RED # Model Color White # Model Color Nickel Mounting Options Agency Approvals U L M E A C S F M F M BF P KFET70-24MCW-FR X - X X 15/30/75/110 X - L,O,P,Q,U,Y X X X X X KFET70-24MCW-FW X - X X 15/30/75/110 - X L,O,P,Q,U,Y X X X X X KFET70-24MCW-ALR X X X 15/30/75/110 X - - L,O,P,Q,U,Y X X X X X KFET70-24MCW-ALW X X X 15/30/75/110 - X - L,O,P,Q,U,Y X X X X X KFET70A-24MCW-ALR X X X 11/22/56/82 X - - L,O,P,Q,U,Y X X X X X KFET70A-24MCW-ALW X X X 11/22/56/82 - X - L,O,P,Q,U,Y X X X X X KFET70-241575W-FR X - X X 15 (75 on Axis) X - L,O,P,Q,U,Y X X X X X KFET70-241575W-FW X - X X 15 (75 on Axis) - X - L,O,P,Q,U,Y X X X X X KFET70-241575W-FN X - X X 15 (75 on Axis) - - X L,O,P,Q,U,Y X X X X X KFET70-24MCWH-FR X - X X 135/185 X - - L,O,P,Q,U,Y X X X X * KFET70-24MCWH-FW X - X X 135/185 - X - L,O,P,Q,U,Y X X X X * KFET90-24MCC-FW - X X X 15/30/75/95 - X - L,Q,U,V,Y X X X X * KFET90-24MCC-FR - X X X 15/30/75/95 X - - L,Q,U,V,Y X X X X * KFET90A-24MCC-FR X X X 11/22/56/82 X - - L,Q,U,V,Y X X X X X KFET90-24MCC-ALW X X X 15/30/75/95 - X - L,Q,U,V,Y X X X X X KFET90A-24MCC-FW X X X 11/22/56/82 - X - L,Q,U,V,Y X X X X X KFET90-24MCCH-FW - X X X 115/177 - X - L,Q,U,V,Y X X X X * KFET90-24MCCH-FR - X X X 115/177 X - - L,Q,U,V,Y X X X X * KFET90-24MCCH-ALW - X X X 115/177 X - - L,Q,U,V,Y X X X X * KFET70-R X X - - - X - - L,O,P,Q,U,Y X X X X X KFET70-W X X - - - - X - L,O,P,Q,U,Y X X X X X KFET90-R X X - - - X - - L,Q,U,V,Y X X X X X KFET90-W X X - - - - X - L,Q,U,V,Y X X X X X Kingfisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 3

ORDERING INFORMATION KCi # Model # Description Wall Mounted Speaker Strobes 80133 KFET70-24MCW-FR 8W SPKR STRB,WALL,24 VDC,15/30/75/110CD,RD 80134 KFET70-24MCW-FW 8W SPKR STRB,WALL,24 VDC,15/30/75/110CD,WHT 80189 KFET70-24MCW-ALR 8W SPKR STRB,WALL,24 VDC, 15/30/75/110CD,ALERT,RD 80190 KFET70-24MCW-ALW 8W SPKR STRB,WALL,24 VDC, 15/30/75/110CD,ALERT,WHT 80604 KFET70A-24MCW-ALR 8W SPKR STRB,WALL,24 VDC, 15/30/75/110CD,ALERT,RD AMBER LENS 81306 KFET70A-24MCW-ALW 8W SPKR STRB,WALL,24 VDC, 15/30/75/110CD,ALERT,WHT AMBER LENS 80135 KFET70-24MCWH-FR 8W SPKR STRB,WALL,H INT,24VDC,135/185CD,RD 80136 KFET70-24MCWH-FW 8W SPKR STRB,WALL,H INT,24VDC,135/185CD,WHT 80607 KFET70-241575W-FR 8W SPKR STRB,WALL,24 VDC,1575CD,RD 80608 KFET70-241575W-FW 8W SPKR STRB,WALL,24 VDC,1575CD,WHT Ceiling Mounted Speaker Strobes 80181 KFET90-24MCC-FR 8W SPKR STRB,CEIL,24 VDC,15/30/75/95CD,RED 80182 KFET90-24MCC-FW 8W SPKR STRB,CEIL,24 VDC,15/30/75/95CD,WHT 80183 KFET90-24MCCH-FR 8W SPKR STRB,CEIL,H INT,24VDC,115/177CD,RD 80184 KFET90-24MCCH-FW 8W SPKR STRB,CEIL,H INT,24VDC,115/177CD,WHT 80605 KFET90A-24MCCH-FR 8W SPKR STRB,CEIL,24 VDC,15/30/75/95CD,RED AMBER LENS 80609 KFET90A-24MCCH-FW 8W SPKR STRB,CEIL,24 VDC,15/30/75/95CD,WHT AMBER LENS 81137 KFET90-24MCC-ALW 8W SPKR STRB, CEIL 24VDC 15/30/75/95CD WHT ALERT LETTERING 80108 KFET90-24MCCH-ALW 8W SPKR STRB,CEIL,H INT,24VDC,115/177CD,WHT ALERT LETTERING Wall or Ceiling Mounted Speakers 80121 KFET70-R 8W SQUARE SPKR,WALL,24VDC,RD 80122 KFET70-W 8W SQUARE SPKR,WALL,24VDC,WHT 80193 KFET90-R 8W ROUND SPKR,CEIL,24VDC,RD 80195 KFET90-W 8W ROUND SPKR,CEIL,24VDC,WHT Kingfisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 4

ORDERING INFORMATION CONTINUED KFCI Part # Model # Description Backboxes, Plates, Grills and Retrofit kit 80492 KFSBB-R BACKBOX,SURFACE,RD 80166 KFSBB-W BACKBOX,SURFACE,WHT 80208 KFISP2-R EXTENDER,SUFACE,INDOOR,RD 80209 KFISP2-W EXTENDER,SUFACE,INDOOR,WHT 80162 KFCBB-8 BACKBOX,8" SPEAKER,RND,WHT 80163 KFSSB-8 TILE BRIDGE,8" SPEAKER SUPPORT 80049 KFECHSG90-R 80048 KFECHG70-W 80047 KFECHGS70W-FW 80046 KFECHGS70W-NW ROUND GRILL, RED PLATE, NO LETTERING, FOR KFET90 SERIES SPEAKER STROBES SQUARE GRILL, WHITE PLATE, NO LETTERING, FOR KFET70 & 90 SERIES SPEAKER ONLY SQUARE GRILL, WHITE PLATE, FIRE LETTERING, FOR KFET70 & 90 SERIES SPEAKER STROBES. SQUARE GRILL, WHITE PLATE, NO LETTERING, FOR KFET70 & 90 SERIES SPEAKER STROBES. Emergency Mass Notification Appliance Strobes 80204 KFE90-24MCC-ALW Speaker/Strobe 25/70V, 1/8 to 2 Watt Selectable, Ceiling Mount, 8 Round, White, 15/30/75/95 Cd (requires 80166 backbox), Clear Lens, ALERT 80206 KFRSSPA-24MCW-NW STRB PLATE,WALL,24 VDC,15/30/75/110CD,WHT AMBER LENS NO LETTERING 80219 KFRSSPA-24MCW-ALW STRB PLATE,WALL,24 VDC,15/30/75/110CD,NO LTR,RD AMBER LENS ALERT 80213 KFSBL2-R BACKBOX,SURFACE FOR RSSP,RD 80214 KFSBL2-W BACKBOX,SURFACE FOR RSSP,WHT 80121-DTS Specification Data Sheet King-Fisher Company, inc., products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with King-Fisher Company, inc., standard terms and conditions King-Fisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 5

BLANK PAGE LEFT INTENTIONALY King-Fisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 6