BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

Similar documents
WATER PURIFYING SYSTEM

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Next Generation Corona Discharge Installation & Operation Manual

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

UV Lamp and Quartz Sleeve Replacement/Maintenance

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Ozone + UV Sanitation

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

TO-SK-1 Tip-Over Switch Kit For FSP-43 AND FSP-95

IMPORTANT INSTRUCTIONS READ & SAVE

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

Instruction Sheet DANGER

Instruction Sheet DANGER

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

IMPORTANT INSTRUCTIONS READ & SAVE

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

Ozone Generator Systems

Ozone Generator Systems

TPI Corporation P.O. BOX 4973 JOHNSON CITY, TN

DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

UV I UNIT030W / UV I UNIT055W

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

UV Biological Pond Filter. Inlet /Outlet Size

INSTALLATION INSTRUCTIONS

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

DIGIHEAT IN LINE HEATERS

INSTALLATION & MAINTENANCE

Model CWA200 Owner s Manual

CHAMPION PUMP OWNER S MANUAL

SLT-Series Installation and maintenance instructions

QUIETFLO OWNER S MANUAL

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

IMPORTANT INSTRUCTIONS READ & SAVE

The Arden Oscillating Floor Fan

OCH-SSE series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Installation Instructions Dual Fuel Ranges

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

SAFETY VACUUM RELEASE SYSTEM (SVRS)

Ozone plus UV Sanitation System Installation & Operations Manual

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

PowerVac G Single to Twin Conversion Kit [ ]

IMPORTANT INSTRUCTIONS READ & SAVE

Spa Control System OWNER S MANUAL

EASYCLEAR 3000 YEAR GUARANTEE

IMPORTANT INSTRUCTIONS READ & SAVE

MODELS 304GC, 304GCX, 314GC, and 314GCX

FOSTORIA INDUSTRIES, INC North Main Street Fostoria, OH Phone: Fax:

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

tungsten Smart-heat electric heater

tungsten Smart-heat electric heater

PZ1, PZ3 & PZ6 Installation Guide

MDX² INSTALLATION MANUAL

SMF PUMP OWNER S MANUAL

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Duke Manufacturing Co.

MODELS ASHP, ASHH, ASUP, and ASUH

mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

GDDEM10 DEHUMIDIFIER

Electric Fireplace. Electric Fireplace

CoolTouch TM control system

Manual INFRARED HEATER HT200

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

Sunbeam Brushed Remote Control Tower Fan

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

Sealed Electric Wall & Floor Mounted Towel Warmers. heatingthroughinnovation. Installation, Operating, Maintenance and After Sales Manual.

Ozone plus UV Sanitation System Installation & Operations Manual

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

DIRTY WATER SUBMERSIBLE PUMP

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

SS1095 Ice Maker.

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

4230/6230/9230 SERIES OWNERS OPERATION GUIDE

INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION GUIDE SD27, SD33, SD39, SD45, SW14. Quick Reference Guide:

Pro-MAX Ultraviolet Sterilizer

Next Generation Corona Discharge Next Generation Corona Discharge Nueva generación Corona de descarga

Installation Instructions

Water Boilers ME10EN, ME15EN. Table of Contents

SAND FILTER PUMP MANUAL

Transcription:

BALLAST REPLACEMENT INSTALLATION MANUAL WARNING Turn off power at main source before making any electrical connections or servicing the unit. UV light produced by this unit is harmful to the eyes and may cause blindness! Do not look directly at a lit bulb! Contents Signal Words and Symbols Used In This Manual...2 Ballast Replacement USA...3 Ballast Replacement AU...6 The ballast resets instantly on restoration of power. When the lamp restarts, it will light up orange first then turn blue in about 10 seconds. If the UV bulb still does not illuminate 1-800-627-5886 and ask for customer service for further instructions. NOTE: Ozone production from direct UV light will decline over time. UV bulbs continue to illuminate after they stop producing an effective level of ozone to clean your pool water. To make sure your pool continues to receive all the benefits of ozone, Paramount recommends that you replace your bulb every three (3) years or 13,000 operating hours. 004-027-7858-00 ECN1294 REV00 PUBLISH 01/16/18 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com www.1paramount.com

Signal Words and Symbols Used In This Manual This Owner s Manual and Installation Guide contains specific precautions and symbols to identify safety-related information. You will find DANGER, CAUTION, WARNING and NOTICE symbols which require special attention. Please read them carefully and follow these precautions as indicated! They will explain how to avoid hazards that may endanger you or persons using or maintaining your pool or spa. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. PLEASE REVIEW THE OWNER S MANUAL AND INSTALLATION GUIDE IN ITS ENTIRETY AND HEED ALL SAFETY INFORMATION. Failure to follow these instructions and warnings can result in DEATH OR SERIOUS INJURY. SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELY BEFORE PROCEEDING WITH INSTALLATION. SAVE THESE INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: CAUTION READ AND FOLLOW ALL INSTRUCTIONS Follow all applicable electrical codes. A qualified licensed electrician should perform electrical hookup. Turn off power at main source before making any electrical connections or servicing the unit. Use only liquid-tight flexible nonmetallic conduit for electrical connections. A terminal marked G is located inside the supply terminal compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electrical supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment. At least one lug marked BONDING LUG provided on the external surface of the unit. To reduce the risk of electric shock, connect the local common bond grid in the area of the pool or spa to this terminal with an insulated or bare copper conductor not smaller than 6 AWG. ALWAYS wear safety glasses when using power equipment during the WARNING installation process. Install at least 5 ft from pool or spa water using nonmetallic plumbing. Mount ozone generator near pool equipment at least one (1) foot above maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions. Short-term inhalation of high concentrations of ozone and long-term inhalation of low concentrations of ozone gas can cause serious harmful physiological affects. Do not inhale gas produced by this unit. If installed in an enclosed space make sure to account for adequate ventilation. UV LIGHT PRODUCED BY THIS UNIT IS HARMFUL TO THE EYES AND MAY CAUSE BLINDNESS. DO NOT LOOK DIRECTLY AT A LIT BULB! NOTICE TO INSTALLER/OWNER: Save these instructions and deliver to pool owner when installation is complete. Lamp contains mercury. Dispose of in accordance with local and state regulations. 2

Ballast Replacement USA 1. Turn the supply power to unit off. Disconnect the flow meter assembly from the Clear 03 electrical housing & set safely aside. 2. Remove the earth ground from Clear 03 aluminum body. 3. Remove the left side end cap & gasket. When reassembling unit, replace gasket. 4. Disconnect the supply power and ground wiring from electrical housing. 5. Remove the flex connector nut & pull the supply wire conduit from Clear 03 electrical housing. 3 6. Loosen the screws on upper & lower mounting brackets. Remove the Clear 03 unit from the mounting location. 7. Disconnect the lamp connector from lamp (do not pull directly on wires).

8. Remove lamp from housing & safely set aside, making sure not to touch the lamp glass with bare hands. Wear protective rubber gloves. Back 9. Remove the two screws that secure the electrical housing to the aluminum body. 10. Remove the two screws that secure the supply power terminal block to the electrical housing (NOTE that white wire is towards the back). 11. Gently slide the electrical enclosure from the aluminum body, while holding the lamp connector. 12. Remove the gasket, as needed, from the aluminum body. When reassembling unit, replace gasket. 13. Remove the outer nut from the grounding post. Slide both ground wire ring terminals from the post. 14. Slide the ballast assembly from the body. 15. Re-assemble unit with new ballast assembly by reversing steps 1-16 described above. NOTE: Be careful not to pinch or roll new gaskets during re-assembly. 4

ECO FRIENDLY PARAMOUNT CERTIFIED BALLAST REPLACEMENT AUSTRALIA INSTALLATION MANUAL The ballast resets instantly on restoration of power. When the lamp restarts, it will light up orange first then turn blue in about 10 seconds. If the UV bulb still does not illuminate 1-800-627-5886 and ask for customer service for further instructions. NOTE: Ozone production from direct UV light will decline over time. UV bulbs continue to illuminate after they stop producing an effective level of ozone to clean your pool water. To make sure your pool continues to receive all the benefits of ozone, Paramount recommends that you replace your bulb every three (3) years or 13,000 operating hours. 004-027-7858-00 ECN1294 REV00 PUBLISH 102317 US and Foreign patents and patents pending see www.1paramount.com/about/patents/ 295 East Corporate Place Suite 100 Chandler, AZ 85225 Toll Free: 1.800.621.5886 Phone: 480.893.7607 Fax: 480.753.3397 Paramount@1Paramount.com www.1paramount.com

DANGER ONLY A CERTIFIED TECHNICIAN IS PERMITTED TO CONDUCT SERVICE ON THE UNIT. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Children should be supervised to ensure that they do not play with the appliance. WARNING Do not operate the UV-C emitter when it is removed from the appliance enclosure SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELY BEFORE PROCEEDING WITH INSTALLATION. SAVE THESE INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: ALWAYS wear safety glasses when using power equipment during the WARNING installation process. Install at least 5 ft from pool or spa water using nonmetallic plumbing. Mount ozone generator near pool equipment at least one (1) foot above maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instructions. Short-term inhalation of high concentrations of ozone and long-term inhalation of low concentrations of ozone gas can cause serious harmful physiological affects. Do not inhale gas produced by this unit. If installed in an enclosed space make sure to account for adequate ventilation. UV LIGHT PRODUCED BY THIS UNIT IS HARMFUL TO THE EYES AND MAY CAUSE BLINDNESS. DO NOT LOOK DIRECTLY AT A LIT BULB! This appliance contains a UV-C emitter. The UV-C emitter does not require cleaning during its life span. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. Appliances that are obviously damaged must not be operated. This appliance is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 ma.

Ballast Replacement AU 1. Turn the supply power to unit off. Disconnect the power cord from electrical supply. Disconnect the flow meter assembly from Clear O3 electrical housing and set safely aside 2. Remove the left side end cap & gasket. When reassembling, replace gasket. 3. Loosen the screws on the upper & lower mounting brackets. Remove Clear O3 unit from the mounting location. Loosen the seal-tight connector that secures the supply power cord to the electrical housing. 4. Disconnect the lamp connector from lamp (do not pull directly on wires). 5. Remove lamp from housing & safely set aside, making sure not to touch the lamp glass with bare hands. Wear protective rubber gloves. 6. Remove the two power wires (brown & blue) from the terminal block. Remove the two screws that secure the electrical housing to the aluminum body. 7

7. Remove the two screws that secure the terminal block to the electrical housing. Note that the white wire is towards the back. 8. Gently slide the electrical housing from the aluminum body to expose the ground lug location. 9. Remove the outer nut from the grounding post. Slide both ground wire ring terminals from the post. 10. Slide the ballast assembly from the body. 11. Reassemble with new ballast assembly by reversing steps described above. Note: Be careful not to pinch or roll new gaskets during reassembly. 8