EMERGENCY PROCEDURES XL2

Similar documents
Liberty XL2 Emergency Procedures Checklist

Emergency Procedures Training

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

Memory Items 2

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

T-6B Electrical System. Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com

CIRRUS AIRPLANE MAINTENANCE MANUAL

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft

Installation and Operation Manual AEC9005 Series Low Voltage Warning and Auxiliary Battery Management Modules

System Fifty Five X Autopilot. Pilot s Operating Handbook

REFERENCE ONLY FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

Section - III SYSTEMS DESCRIPTION

CIRRUS AIRPLANE MAINTENANCE MANUAL

OWNERS MANUAL MODEL 451 (-101 & -201)

Pressurization System

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

TECHNICAL MANUAL. Operator's and Crewmember's Checklist ARMY MODELS RC-12P NSN AND RC-12Q NSN AIRCRAFT

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Fokker 50 - Integrated Alerting Unit

Instrument and Control Panels

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Section - III SYSTEMS DESCRIPTION

Expanded Normal Procedures

Helicycle Crew Alerting System (CAS)

HEADQUARTERS, DEPARTMENT OF THE ARMY 01 JANUARY 2001

Document No

Indirect gas-fired air heater

Learjet - CAPABILITIES

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

von Jens Alb bert Scheenk n: 1.0 Version 2007 www w.simtutorials.com Hamb burg 2007

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF).

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

DC3Training.com N28AA DC-3 Pilot s Handbook

Homeowner s Installation Instructions & Operating Manual

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

The TC-2 also records maximum temperatures reached for each channel in permanent memory.

ENGINE GENERATORS AND ACCESSORIES

The TC-1 also records maximum temperatures reached for each channel in permanent memory.

Canadair Regional Jet 100/200 - Lighting

Owner s Manual For Model Aero-553 (Rev. A.)

SD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)

TEMPERATURE CONTROLLERS

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

A380 Special Condition D 04 Crew Rest Compartment

Stratomaster Maxi Single

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

IFT-RC150 IntelliFire Touch Remote Control Installation Instructions

Remote Aural Warning System and Summing Amplifier Installation and Operation Manual

User Operation Manual

FIRE PROTECTION TABLE OF CONTENTS CHAPTER 9

DASSAULT AVIATION Proprietary Data

SAFETY INFORMATION NOTICE

CIRRUS AIRPLANE MAINTENANCE MANUAL

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Baxi Maxflow Combi WM

Dornier 328Jet - Lights

COMPONENT MAINTENANCE MANUAL INDEX. Aug 2013

Baxi Maxflow Combi FS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Diocese of Cleveland Facilities Services Corporation

Das Trainingsmaterial ist so aufbereitet, dass es auf unterschiedlichen Endgeräten dargestellt und verteilt werden kann.

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

LGB Gas fired boiler

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

New Power Vented Rheem FVIR Tanks

Functional Performance Test

Blaze INFO-2. Information Display

Procedure. for. Installation. of the P/N & P/N Voice Alert Systems. Procedure IP 1 Rev. 1. Date

Why AC800M High Integrity is used in Burner Management System Applications?

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Homeowner s Installation Instructions & Operating Manual

CESCOM 20 - Projected Maintenance Due

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

DIRECTIVE NO: D-B

Stratomaster Ultra. Owner's Manual. Installation guide. Stratomaster Ultra L Owner s manual. Model L MKII with RDAC V EIS.

BlueHeat Coolant Heater Car and Light Truck Auxiliary Heater

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

LGA... Gas Burner Controls. Building Technologies Division

CHAPTER 11 AIR CONDITIONING

DASSAULT AVIATION Proprietary Data

REMOTE CONTROL UNIT. Ignition Open the gas supply tap. Press the switch (5) of the gas valve in I position.

Section 8: Supplements

P0032-O2 SENSOR 1/1 HEATER CIRCUIT HIGH

Homeowner s Installation Instructions & Operating Manual

Attached is Supplement three for service manual We suggest you file this with your Manual for reference.

Tactical Scenario PA1 (Scenario IOS file name: APR39WarmUp)

Digital Control Systems & Remote Communications Options

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

Canadair Regional Jet 100/200 - Water & Waste

Transcription:

ENGINE FAILURE DURING FLIGHT GENERAL EMERGENCY PROCEDURES XL2 This section provides the recommended procedures for coping with various emergency or critical situations. All of the emergency procedures required by the FAA, as well as those necessary for the operation of the airplane are presented. This section contains the emergency procedures checklist. They supply an immediate action sequence to be followed during critical situations with little emphasis on operation of the systems. The amplified emergency procedures corresponding to the emergency procedures checklist items are found in the Aircraft Flight Manual (AFM). These amplified procedures contain additional information to provide the pilot with a more complete description of the procedures so they may be more easily understood. Pilots must familiarize themselves with the procedures in this section and must be prepared to take the appropriate action should an emergency situation arise. The procedures are offered as a course of action for coping with the particular situation or condition described. They are not a substitute for sound judgment and common sense. Most basic emergency procedures are a normal part of pilot training. The information presented in this section is not intended to replace that training. The pilot should review standard emergency procedures periodically to remain proficient in them. All emergency procedures outlined in boxes need to be committed to memory and can be referred to if time permits. Procedures that are not outlined in boxes should be performed by reference to the appropriate emergency checklist. 1. Establish Best Glide Attitude...80 KIAS 2. Fuel Selector Valve...CHECK ON 3. Throttle...OPEN ¾ INCH 4. Fuel Boost Pump Mode Switch... ON 5. FADEC A and B PWR Switches... RECYCLE SIMULTANIOUSLY 6. Ignition Switch... CHECK BOTH 7. Ignition Switch (If Prop NOT Windmilling)...START 8. Throttle...ADJUST TO OBTAIN BEST ENGINE OPERATION 9. Repeat steps 2 6 as necessary with prop windmilling. 10. If engine does not start, perform Forced Landing checklist. FORCED LANDING 1. Establish Best Glide Attitude...80 KIAS 2. Radio... TRANSMIT (121.5 mhz) MAYDAY (giving location and intentions) 3. Transponder...SQUAWK 7700 4. ELT (if off airport)... ACTIVATE 5. Ignition Switch...OFF 6. FADEC A and B PWR Switches...OFF 7. Fuel Boost Pump Mode Switch...OFF 8. Throttle...IDLE 9. Fuel Selector Valve... OFF (lift knob to turn OFF) 10. Flaps (when field is made)... AS REQUIRED or 30 11. Master Switch...OFF 12. Seat Belts and Shoulder Harness... SECURE Flaps will not operate when Master Switch is off. Do not turn the Master Switch off until after flaps have been set to their final desired position and the landing is assured. 1 2

ENGINE PARTIAL POWER LOSS Engine roughness is most frequently caused by ignition problems (misfire, fouled spark plugs, etc.), and less frequently by fuel injection problems (failed or blocked fuel injector, etc.). 1. Fuel Boost Pump Mode Switch...ON 2. Fuel Selector Valve... CHECK ON 3. Alternate Induction Air...PULL ON 4. Ignition Switch...CHECK R, L, BOTH If engine operation is significantly smoother in either the L or R position, leave the switch in that position. 5. LAND...AS SOON AS PRACTICAL ENGINE FAILURE AFTER TAKEOFF 1. Best Glide or Landing Speed (as appropriate)... ESTABLISH 2. Flaps... AS REQUIRED If time permits: 3. Ignition Switch...OFF 4. FADEC A and B PWR Switches...OFF 5. Master Switch...OFF 6. Throttle... IDLE 7. Fuel Selector Valve...OFF (lift knob to turn OFF) 8. Seat Belts and Shoulder Harness... SECURE ENGINE FAILURE DURING TAKEOFF ROLL 1. Throttle... IDLE 2. Brakes...APPLY After aircraft stops: 3. Ignition Switch...OFF 4. FADEC A and B PWR switches...off 5. Master Switch...OFF 6. Fuel Selector Valve...OFF (lift knob to turn OFF) ENGINE FIRE DURING START 1. Ignition Switch... START Continue turning the engine over in attempt to obtain successful start that will suck flame and accumulated fuel into engine. If Engine Starts: 2. Power...1700 RPM (for up to two minutes, if conditions allow) 3. Engine...SHUT DOWN (inspect for damage) If Engine does NOT Start: 4. Ignition Switch... START 5. Throttle...FULL FORWARD 6. FADEC A and B PWR Switches...OFF 7. Fuel Selector Valve...OFF (lift knob to turn OFF) 8. Cranking... TERMINATE 9. Ignition Switch...OFF 10. Master Switch...OFF 11. Airplane...EVACUATE 12. Fire... EXTINGUISH (Use fire extinguisher as necessary) 13. Fire Damage...INSPECT ENGINE FIRE IN FLIGHT 1. Fuel Selector Valve...OFF (lift knob to turn off) 2. Throttle... IDLE 3. Cabin Heat... OFF 4. Fuel Boost Pump Mode Switch...OFF 5. FADEC A and B PWR Switches...OFF 6. Ignition Switch...OFF 7. Perform Forced Landing checklist Do not attempt to restart engine after engine fire in flight. 3 4

CABIN FIRE IN FLIGHT 1. Master Switch...OFF 2. FADEC PWR A Switch...OFF 3. Avionics Master Switch...OFF 4. All Electrical Switches... OFF (Except FADEC PWR B Switch) Turning off FADEC PWR B switch when Master Switch is OFF will cause immediate loss of engine power. 5. Cabin Heat...OFF 6. Fire Extinguisher... ACTIVATE 7. Air Vents... OPEN TO VENT CABIN 8. LAND... AS SOON AS PRACTICAL DOOR OPEN IN FLIGHT Abort takeoff if door opens during takeoff. In flight, do not allow efforts to reclose the door interfere with the primary task of maintaining control and flying the airplane. 1. Airspeed... REDUCE TO 80-90 KIAS 2. Door... CLOSE AND LATCH Yaw airplane in direction of open door if necessary. 3. Approach Speed...NORMAL If unable to latch door in flight, or if damage has occurred: SPIN RECOVERY If an inadvertent spin occurs, use the following recovery procedure: 1. Throttle... IDLE 2. Ailerons... NEUTRAL 3. Rudder... FULL OPPOSITE DIRECTION OF SPIN 4. Control Stick..FORWARD TO BREAK STALL 5. Neutralize Rudder...MAKE SMOOTH PULL UP 6. Throttle.ADJUST FOR STRAIGHT AND LEVEL FLIGHT SYSTEM MALFUNCTIONS HSA FAULT LIGHT INDICATIONS BOTH HSA EBAT FL AND PPWR FL ANNUNCIATORS ILLUMINATED: 1. FADEC PWR A and B switches... CHECK ON 2. FADEC PWR A and B circuit breakers... CHECK IN If Annunciators Remain ON: 3. LAND...AS SOON AS PRACTICAL emergency battery is properly maintained and fully charged. Plan to land well within 60 minutes from illumination of EBAT FL and PPWR FL annunciators. HSA EBAT FL ANNUNCIATOR ONLY ILLUMINATED: 1. FADEC PWR B Switch... CHECK ON 2. FADEC PWR B Circuit Breakers... CHECK IN If annunciator remains illuminated: 3. LAND...AS SOON AS PRACTICAL Illumination of only the EBAT FL annunciator may indicate failure of the emergency battery. Should the alternator also fail, the engine will only be powered by the primary battery, which is also affected by other electrical loads. HSA RED FADEC CAPTION ILLUMINATED: 1. Engine Instruments... MONITOR 2. LAND...AS SOON AS PRACTICAL 5 6

HSA FUEL PMP ANNUNCIATOR ILLUMINATED IN FLIGHT: 1. Fuel Boost Pump Mode Switch... CHECK AUTO 2. Fuel Pressure Gauge...MONITOR If Condition or Annunciation persists: 3. Fuel Boost Pump Mode Switch...ON ELECTRICAL SYSTEM MALFUNCTIONS AMMETER ABNORMALLY HIGH: 1. Alternator Side (ONLY) of Master Switch...OFF 2. Non-essential Electrical Equipment...OFF 3. LAND... AS SOON AS PRACTICAL After loss or shutdown of alternator, EBAT FL and PPWR FL annunciators may illuminate. battery is properly maintained and fully charged. Plan to land well within 60 minutes from illumination of EBAT FL and PPWR FL annunciators. VOLTMETER ABNORMALLY LOW DURING FLIGHT: ALT FAIL ANNUNCIATOR ILLUMINATES DURING FLIGHT Illumination of the ALT FAIL light in-flight can result either from alternator failure or from alternator tripping offline due to momentary over voltage. The following procedure should reset the alternator system. 1. Ammeter...CHECK FOR 0 AMPS 2. Alternator Side of Master Switch... OFF 3. Non-essential Electrical Equipment... OFF 4. Alternator Circuit Breaker... CHECK IN 5. Alternator Side of Master Switch...ON 6. ALT FAIL Annunciator...CHECK OFF 7. Voltmeter...CHECK IN GREEN ARC If ALT FAIL annunciator remains illuminated: 8. Alternator Side of Master Switch... OFF 9. LAND...AS SOON AS PRACTICAL After loss or shutdown of alternator, EBAT FL and PPWR FL annunciators may illuminate. battery is properly maintained and fully charged. Plan to land well within 60 minutes from illumination of EBAT FL and PPWR FL annunciators. 1. Non-essential Electrical Equipment...OFF 2. Perform ALT FAIL Annunciator Illuminates During Flight checklist. VOLTMETER IN RED ARC DURING FLIGHT: 1. LAND... AS SOON AS PRACTICAL 7 8

ELEVATOR TRIM MALFUNCTIONS ELEVATOR TRIM INOPERATIVE: 1. ELEV TRIM Circuit Breaker...CHECK, RESET IF NECESSARY 2. Trim Motor...CHECK BOTH DIRECTIONS NOTE If trim moves in only one direction, minimize further use of trim to reduce out-of-trim forces on landing. UNCOMMANDED ELEVATOR TRIM MOTION: 1. Control Stick...RESTRAIN To maintain flight path and contain out-of-trim forces. 2. Elevator Trim Switch... ACTUATE IN OPPOSITE DIRECTION This may halt trim motion and/or trip ELEV TRIM circuit breaker. 3. ELEV TRIM Circuit Breaker...PULL, DO NOT RESET NOTE To relieve control stick forces, if trim has runaway nose down, use full flaps (30 ) for landing; if trim has runaway nose up, land with flaps up (0 ). 9