INSTALLATION INSTRUCTION

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS INSTALLATION INSTRUCTION MODELS H*DE018 THRU H*DE060 NOMENCLATURE GENERAL LIMITATIONS INSPECTION

CONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS INSTALLATION INSTRUCTION MODELS H*DB076 NOMENCLATURE GENERAL LIMITATIONS INSPECTION REFERENCE

INSTALLATION MANUAL R-22/R-407C OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: GCGA SERIES 1.5 TO 6.3 TONS 1 & 3 PHASE LIST OF SECTIONS LIST OF FIGURES

INSTALLATION INSTRUCTION

ACCESSORY KIT INSTALLATION MANUAL ADD-ON FOSSIL FUEL CONTROL PANEL S1-2AC FOR USE WITH MODELS: FRHS, E*FD, E*RE OR E*BE HEAT PUMPS

INSTALLATION MANUAL LISTED

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

AWARNING A CAUTION R-22 OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: 13 SEER - ERCQ SERIES 2 TO 4 TONS LIST OF SECTIONS.

INSTALLATION MANUAL LISTED R-410A OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: 16 SEER - CZF / AC6B / AL6B SERIES 2 TO 5 TONS TABLE OF CONTENTS

MODELS B1PA024, 030 AND 036

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Condensing Unit Installation and Operating Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY

APPLICATION DATA SHEET

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES. LIST OF TABLES Application Limitations...2 R-410A Saturation Properties... 8

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL WARNING CAUTION CAUTION

RAWL - HIGH EFFICIENCY

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

Condensing Unit Installation and Operating Instructions

Installation Manual VERTICAL DISCHARGE AIR CONDITIONER

SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNITS. INSTALLATION INSTRUCTION Supersedes: N1Y (497) N1Y (998) MODELS E2FB090 & E1FB120 GENERAL

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTION

Service Step by Step Trouble-Shooting Check-List

CAUTION. Check Equipment and Job Site. Clearance Requirements. Unpack Unit

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Installation Instructions

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION MANUAL WARNING WARNING FULL-CASED UPFLOW/COUNTERFLOW FOR COOLING/HEAT PUMPS FULL-CASED MULTI-POSITION FOR COOLING/HEAT PUMPS MODELS: CF

User s Information and Installation Instructions

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNITS. INSTALLATION INSTRUCTION Supersedes: Nothing N1Y (692) MODELS E1FB090 & 120 (50 & 60 HZ) GENERAL

Installation Instructions

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

User s Information/Installation Instructions

MODELS E1FB180 & E1FB240

Installation Instructions

INSTALLATION MANUAL R-410A OUTDOOR SPLIT-SYSTEM AIR CONDITIONING MODELS: 15 SEER - CZE / AC5B / AL5B SERIES 2 TO 5 TONS LISTED TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS

Installation Instructions

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION MANUAL R-22 OUTDOOR SPLIT-SYSTEM HEAT PUMP SHIPPED WITH NITROGEN CHARGE ONLY MODELS: 13 SEER - GHGD 1.5 TO 5 TONS LIST OF SECTIONS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

INSTALLATION INSTRUCTIONS

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

FOSSILFUELKITAXWR02FFA1

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP13LE Series Split System Heat Pump

INSTALLATION MANUAL SINGLE PIECE STANDARD ECM AIR HANDLERS MODELS: AHX61 SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

INSTALLATION INSTRUCTIONS

Installation Instructions

SPLIT-SYSTEM EVAPORATOR BLOWER (AIR COOLED) INSTALLATION INSTRUCTION Supersedes: Nothing N4C-0500

INSTALLATION MANUAL SPLIT-SYSTEM CONDENSING UNITS (AIR COOLED) HB Ton HB Ton HB Ton NOTES, CAUTIONS AND WARNINGS

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

INSTALLATION INSTRUCTIONS

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SHP16LT Series Split System Heat Pump

INSTALLATION INSTRUCTIONS

Installation Instructions

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions

Installation Instructions

EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions

INSTALLATION INSTRUCTION

AHG**-0B Series Hydronic Air Handling Units

INSTALLATION AND MAINTENANCE INSTRUCTIONS 2SCU13 Series Split System Air Conditioner WARNING

INSTALLATION INSTRUCTIONS

R-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES

INSTALLATION / START-UP INSTRUCTIONS 4HP13/14 SPLIT SYSTEM HEAT PUMP HOMEOWNERS INFORMATION MANUAL

User s Information and Installation Instructions

INSTALLATION INSTRUCTIONS

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

PACKAGE AIR CONDITIONER

Installation Instructions

38LB/38LF AIR COOLED CONDENSING UNIT

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL COMMERCIAL SPLIT SYSTEM COOLING UNITS 4 PIPE SYSTEMS. HB 180 & thru 20 Nominal Tons NOTES, CAUTIONS AND WARNINGS

Transcription:

INSTALLATIN INSTUCTIN STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEE 2.5 T 5 TNS TABLE F CNTENTS GENEAL INFMATIN...................... 2 SAFETY....................................... 2 INSPECTIN................................... 2 LIMITATINS................................... 2 UNIT INSTALLATIN.......................... 3 LCATIN..................................... 3 GUND INSTALLATIN......................... 3 F INSTALLATIN............................ 3 UNIT PLACEMENT............................ 4 HEAT PUMP................................. 4 PIPING CNNECTINS........................ 5 PECAUTINS DUING LINE INSTALLATIN........ 5 PECAUTINS DUING BAZING F LINES......... 5 PECAUTINS DUING BAZING ANGLE VALVE.... 6 ELECTICAL CNNECTINS.................. 7 GENEAL INFMATIN & GUNDING............ 7 PWE WIING................................ 7 ACCESSY WIING............................ 7 THEMSTAT MUNTING / WIING............... 7 DE-HUMIDIFICATIN CNTL................... 8 FSSIL FUEL ELAY CNTL................... 8 FIELD CNNECTINS - CNTL WIING.......... 8 CFM SELECTIN BAD SETTINGS............... 9 TANSFME INSTALLATIN................... 9 SYSTEM CHAGE............................ 9 EFIGEANT LINE CHAGES.................... 9 ENEGIZE CANKCASE HEATE.............. 10 SYSTEM PEATIN........................ 10 LCKUT MDES.............................. 12 PEATIN BELW LW-TEMPEATUE CUT-FF. 12 PEATIN IN EMEGENCY HEAT PSITIN...... 12 SUPPLEMENTAL ELECTIC HEAT................ 12 GAS FUNACE HEAT........................... 12 DEFST CYCLE.............................. 12 INDICATINS F PPE CLING PEATIN... 13 INDICATINS F PPE HEATING PEATIN... 13 NTICE T WNE......................... 13 MAINTENANCE............................. 13 WIING DIAGAM........................... 14 MDELS: E4TS030 E4TS036 E4TS048 E4TS060 CAUTIN:EAD ALL SAFETY GUIDES BEFE YU STAT T INSTALL YU UNIT. SAVE THIS MANUAL 035-16472-002 ev. A (0803)

GENEAL INFMATIN The outdoor units are designed to be connected to a matching indoor coil with sweat connect lines. Sweat connect units are factory charged with refrigerant for a matching indoor coil plus 15 feet of field supplied lines. Matching indoor coils are available with an orifice liquid feed (YKMATE flow control device) sized for the most common usage. The thermal expansion valve and/or refrigerant charge may need to be changed for some indoor-outdoor unit combinations, elevation differences or total line lengths. efer to Application Data covering General Piping ecommendations and efrigerant Line Length (Form 690.01- AD1V). SAFETY Use this instruction in conjunction with the instruction for the appropriate indoor evaporator coil, variable speed air handler or furnace and other accessories. ead all instructions before installing the unit. Installer should pay particular attention to the words: NTE, CAUTIN and WANING. NTES are intended to clarify or make the installation easier. CAUTINS are given to prevent equipment damage. WANINGS are given to alert the installer that personal injury and/or equipment damage may result if installation procedures are not handled properly. This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state, and national codes including, but not limited to, building, electrical, and mechanical codes. Incorrect installation may create a condition where the operation of the product could cause personal injury or property damage. INSPECTIN As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. See Local Distributor for more information. LIMITATINS The unit should be installed in accordance with all national and local safety codes and the limitations listed below: 1. Limitations for the indoor unit, coil and appropriate accessories must also be observed. 2. The outdoor unit must not be installed with any duct work in the air stream. The outdoor fan is the propeller type and is not designed to operate against any additional external static pressure. 3. ptimal performance is gained by using a variable speed air handler or furnace. 4. The maximum and minimum conditions for operation must be observed to assure a system that will give maximum performance with minimum service. Table 1: APPLICATIN LIMITS AI TEMPEATUE DB N UTD CIL AI TEMPEATUE N IND CIL Min. Max. Min. Max. Cool Heat Cool Heat 60-10 1 1. 2. WB Cool DB Heat 115 75 57 50 2 WB Cool DB Heat 72 80 Below -10 F, the unit operates automatically with resistance heat or furnace only. peration below this temperature is permissible for a short period of time, during morning warm-up. 5. The unit should not be operated in cooling mode at outdoor temperatures below 60 F. The unit is not designed to operate with a low ambient kit. Do not modify the control system to operate with any type of low ambient kit. 6. Indoor evaporator coil orifice must be removed prior to the installation of a factory supplied balanced port TXV kit. 2 Unitary Products Group

T IND BLWE THEMSTAT T PWE SUPPLY NEC CLASS 1 WIING WEATHEPF DISCNNECT SWITCH 48 VEHEAD CLEAANCE 12 EA AND SIDES NEC CLASS 2 WIING T CIL 24 SEVICE ACCESS CLEAANCE NTE: All outdoor wiring must be weatherproof Seal opening(s) with permagum or equivalent FIGUE 1 : Typical esidential utdoor Unit Location UNIT INSTALLATIN LCATIN Before starting the installation, select and check the suitability of the location for both the indoor and outdoor unit. bserve all limitations and clearance requirements. The outdoor unit must have sufficient clearance for air entrance to the condenser coil, for air discharge and for service access. See Figure 1. NTE: For multiple unit installations, units must be spaced a minimum of 18 inches apart. (Coil face to coil face.) If the unit is to be installed on a hot sun exposed roof or a black-topped ground area, the unit should be raised sufficiently above the roof or ground to avoid taking the accumulated layer of hot air into the outdoor unit. Provide an adequate structural support. GUND INSTALLATIN The unit may be installed at ground level on a solid base that will not shift or settle, causing strain on the refrigerant lines and possible leaks. Maintain the clearances shown in Figure 1 and install the unit in a level position. Isolate the base from the structure to avoid noise or vibration transmission. Normal operating sound levels may be objectionable if the unit is placed directly under windows of certain rooms (bedrooms, study, etc.). Condensate will drain from beneath the coil of the outdoor unit during the defrost cycle. Normally this condensate may be allowed to drain directly on the ground. The outdoor unit should not be installed in an area where mud or ice could cause personal injury. emember that condensate will drip from the unit coils during heat and defrost cycles and that this condensate will freeze when the temperature of the outdoor air is below 32 F. Elevate the unit sufficiently to prevent any blockage of the air entrances by snow in areas where there will be snow accumulation. Check the local weather bureau for the expected snow accumulation in your area. F INSTALLATIN When installing units on a roof, the structure must be capable of supporting the total weight of the unit, including a pad, lintels, rails, etc., which should be used to minimize the transmission of sound or vibration into the conditioned space. Isolate the unit from rain gutters to avoid any possible wash out of the foundation. Unitary Products Group 3

UNIT PLACEMENT UNIT BASE PAN NTE: D NT BLCK DAINAGE HLES WITH GMMETS. UNIT BASE PAN UBBE ELEVATING GMMETS 2. After holding charge is completely discharged, loosen and remove the liquid line fitting from the orifice distributor assembly. Note that the fitting has right hand threads. 3. emove the orifice from the distributor body using a small diameter wire or paper clip. rifice is not used when the TXV assembly is installed. 4. After orifice is removed, install the thermal expansion valve to the orifice distributor assembly with supplied fittings. Hand tighten and turn an additional 1/8 turn to seal. Do not over tighten fittings. 5. e-install the liquid line to the top of the thermal expansion valve. Hand modify the liquid line to align with casing opening. 6. Install the TXV equalizer line into the vapor line as follows: a. Select a location on the vapor line for insertion of the equalizer line which will not interfere with TXV bulb placement. FIGUE 2 : Positioning Grommets 1. Provide a base in the pre-determined location. 2. emove the shipping carton and inspect for possible damage. 3. tie-down bolts should remain tightened. 4. Position the unit on the base provided. 5. Sit unit on the (4) rubber elevating grommets if provided. Use grommet kit 1SG0601 if not provided. These should be positioned as shown in Figure 2 to reduce noise and allow for proper drainage. NTE: The base pan may differ in appearance, but the location of grommets is the same. 6. Make a hole(s) in the structure wall large enough to accommodate the insulated vapor line, the liquid line and the wiring. HEAT PUMP This heat pump requires the installation of a thermal expansion valve. The TXV controls the superheat of the refrigerant at the outlet of the evaporator coil, ensuring the proper refrigerant temperature at the compressor suction. Following are the basic steps for installing the TXV. For detailed instructions, refer to the Installation Instructions accompanying the TXV kit. Install TXV kit as follows: 1. First, relieve the holding charge by depressing the Schrader valve located in the end of the liquid line. b. Use an awl to punch through the suction tube and insert the awl to a depth to achieve a 1/8 inch diameter hole. 7. Install TXV equalizer line in 1/8 hole previously made in vapor line. Equalizer line can be bottomed out in vapor line as end of equalizer line is cut on 45 degrees angle to prevent blockage. Braze equalizer line making sure that tube opening is not brazed closed. Dry nitrogen should always be supplied through the tubing while it is being brazed, because the temperature required is high enough to cause oxidation of the copper unless an inert atmosphere is provided. The flow of dry nitrogen should continue until the joint has cooled. Always use a pressure regulator and safety valve to insure that only low pressure dry nitrogen is introduced into the tubing. nly a small flow is necessary to displace air and prevent oxidation. All connections to be brazed are copper-to-copper and should be brazed with a phosphorous-copper alloy material such as Silfos-5 or equivalent. D NT use soft solder. Install the TXV bulb to the vapor line near the equalizer line, using the two bulb clamps furnished with the TXV assembly. Ensure the bulb is making maximum contact. efer to TXV installation instruction for view of bulb location. The evaporator coil is under 30 psig pressure. In all cases, mount the TXV bulb after vapor line is brazed and has had sufficient time to cool. 4 Unitary Products Group

8. Bulb should be installed on a horizontal run of the vapor line if possible. n lines under 7/8" D the bulb may be installed on top of the line. With 7/8" D and over, the bulb should be installed at the position of about 4 or 8 o'clock. 9. If bulb installation is made on a vertical run, the bulb should be located at least 16 inches from any bend, and on the tubing sides opposite the plane of the bend. n vertical bulb installations, the bulb should be positioned with the bulb tail at the top, so that the bulb acts as a reservoir. 10. Bulb should be insulated using thermal insulation provided to protect it from the effect of the surrounding ambient temperature. PIPING CNNECTINS The outdoor condensing unit may be connected to the indoor evaporator coil using field supplied refrigerant grade copper tubing that is internally clean and dry. Units should be installed only with the tubing sizes for approved system combinations as specified in Tabular Data Sheet. The charge given is applicable for total tubing lengths up to 15 feet. See Application Data Form 690.01-AD1V for installing tubing of longer lengths and elevation differences. NTE: Using a larger than specified line size could result in oil return problems. Using a line size smaller than specified will result in loss of capacity and other problems caused by insufficient refrigerant flow. PECAUTINS DUING LINE INSTALLATIN 1. Install the lines with as few bends as possible. Care must be taken not to damage the couplings or kink the tubing. Use clean, hard drawn copper tubing where no appreciable amount of bending around obstruction is necessary. If soft copper must be used, care must be taken to avoid sharp bends which may cause a restriction. 2. The lines should be installed so that they will not obstruct service access to the coil, air handling system or filter. 3. Care must also be taken to isolate the refrigerant lines to minimize noise transmission from the equipment to the structure. 4. The vapor line must be insulated with a minimum of 1/2" foam rubber insulation (Arm-A-Flex or equivalent). Liquid lines that will be exposed to direct sunlight and/or high temperatures must also be insulated. Tape and suspend the refrigerant lines as shown. D NT allow metal-to metal contact. See Figure 3. 5. Use PVC piping as a conduit for all underground installations as shown in Figure 4. Buried lines should be kept as short as possible to minimize the build up of liquid refrigerant in the vapor line during long periods of shutdown. Incorrect Correct Liquid Line FIGUE 3 : Insulation of Vapor Line T IND CIL LIQUID LINE PVC CNDUIT Sheet Metal Hanger Tape Insulated Vapor Line INSULATED VAP LINE FIGUE 4 : Underground Installation T UTD UNIT CAP 6. Pack fiber glass insulation and a sealing material such as permagum, around refrigerant lines where they penetrate a wall to reduce vibration and to retain some flexibility. 7. See Form 690.01-AD1V for additional piping information. PECAUTINS DUING BAZING F LINES All outdoor unit and evaporator coil connections are copperto-copper and should be brazed with a phosphorous-copper alloy material such as Silfos-5 or equivalent. D NT use soft solder. Dry nitrogen should always be supplied through the tubing while it is being brazed, because the temperature required is high enough to cause oxidation of the copper unless an inert atmosphere is provided. The flow of dry nitrogen should continue until the joint has cooled. Always use a pressure regulator and safety valve to insure that only low pressure dry nitrogen is introduced into the tubing. nly a small flow is necessary to displace air and prevent oxidation. The outdoor units have re-usable service valves on both the liquid and vapor connections. The total system refrigerant charge is retained within the outdoor unit during shipping and installation. The re-usable service valves are provided to evacuate and charge per this instruction. Serious service problems can be avoided by taking adequate precautions to assure an internally clean and dry system. Unitary Products Group 5

PECAUTINS DUING BAZING ANGLE VALVE Precautions should be taken to prevent heat damage to angle valve by wrapping a wet rag around it as shown in Figure 5. Also, protect all painted surfaces and insulation during brazing. After brazing, cool joint with wet rag. This is not a backseating valve. The service access port has a valve core. pening or closing valve does not close service access port. If the valve stem is backed out past the retaining ring, the -ring can be damaged causing leakage or system pressure could force the valve stem out of the valve body possibly causing personal injury. In the event the retaining ring is missing, do not attempt to open the valve. Valve can be opened by removing the plunger cap and fully inserting a hex wrench into the stem and backing out counterclockwise until valve stem just touches retaining ring. eplace plunger cap finger tight, then tighten an additional 1/ 12 turn (1/2 hex flat). Cap must be replaced to prevent leaks. Connect the refrigerant lines using the following procedure. 1. emove the cap and Schrader core from both the liquid and vapor angle valve service ports at the outdoor unit. Connect low pressure nitrogen to the liquid line service port. 2. Braze the liquid line to the liquid valve at the outdoor unit. Be sure to wrap the valve body with a wet rag. Allow the nitrogen to continue flowing. If visual verification of the valve stem reaching the retaining ring is impossible, stop backing out the valve stem when the slightest increase in resistance is felt. Because of the small size and therefore the reduced resistance, back out the liquid valve 5 turns maximum to prevent going past the retaining ring. 3. Carefully remove the brazed plugs from the evaporator liquid and vapor connections after relieving the pressure in the evaporator. The evaporator is pressurized. 4. Braze the liquid line to the evaporator liquid connection. The nitrogen should now be flowing through the evaporator coil. 5. Slide the grommet away from the vapor connection at the coil. Braze the vapor line to the evaporator vapor connection. After the connection has cooled, slide the grommet back into original position. 6. Protect the vapor valve of the outdoor unit with a wet rag and braze the vapor line connection. The nitrogen flow should be exiting the system from the vapor service port connection. After this connection has cooled, remove the nitrogen source from the liquid fitting service port. 7. eplace the Schrader cores in the liquid and vapor valves. 8. Evacuate the vapor line, evaporator and the liquid line, to 500 microns or less. 9. Leak test all refrigerant piping connections including the service port flare caps to be sure they are leak tight. D NT VETIGHTEN (between 40 and 60 inch - lbs. maximum). NTE: Do not use the system refrigerant in the outdoor unit to purge or leak test. 10. eplace caps on service ports. Do not remove the flare caps from the service ports except when necessary for servicing the system. FIGUE 5 : Heat Protection Do not connect manifold gauges unless trouble is suspected. Approximately 3/4 ounce of refrigerant will be lost each time a standard manifold gauge is connected. 6 Unitary Products Group

11. elease the refrigerant charge into the system. pen both the liquid and vapor valves by removing the plunger cap and with an allen wrench back out counter-clockwise until valve stem just touches retaining ring. elease the refrigerant charge into the system. See PECAUTINS DUING BAZING ANGLE VALVE on Page 6. eplace plunger cap finger tight, then tighten an additional 1/ 12 turn (1/2 hex flat). Cap must be replaced to prevent leaks. If a leak is suspected, leak test to locate the leak. To verify the leak, close the valve to the vacuum pump suction to isolate the pump and hold the system under vacuum. If the micron gauge indicates a steady and continuous rise after a few minutes, it's an indication of a leak. If the gauge shows a rise, then levels off after a few minutes and remains fairly constant, it is an indication that the system is leak free, but still contains moisture and may require further evacuation if the reading is above 1000 microns. 12. If the refrigerant tubing, indoor evaporator coil or outdoor condensing unit has developed a leak during shipment, or was, for any other reason, opened to the atmosphere for more than four (4) minutes, it is necessary to evacuate the system down to at least 500 microns to eliminate contamination and moisture in the system. 3. emove the control box cover to gain access to the unit wiring. oute wires from disconnect through power wiring opening provided and into the unit control box as shown in Figure 6. 4. Install the proper size time-delay fuses or circuit breaker, and make the power supply connections. 5. Energize the crankcase heater to save time by preheating the compressor oil while the remaining installation is completed. CNTL WIING LW VLTAGE JUNCTIN BX PWE WIING GUND LUG Never attempt to repair any brazed connections while the system is under pressure. Personal injury could result. See SYSTEM STAT-UP for checking and recording system charge. ELECTICAL CNNECTINS GENEAL INFMATIN & GUNDING Check the electrical supply to be sure that it meets the values specified on the unit nameplate and wiring label. Power wiring, control (low voltage) wiring, disconnect switches and over current protection to be supplied by the installer. Wire size should be sized per NEC requirements. All field wiring must USE CPPE CNDUC- TS NLY and be in accordance with Local, National Fire, Safety & Electrical Codes. This unit must be grounded with a separate ground wire in accordance with the above codes. The complete connection diagram and schematic wiring label is located on the inside surface of the unit electrical box cover and this instruction. PWE WIING 1. Install the proper size weatherproof disconnect switch outdoors and within sight of the unit. 2. un power wiring from the disconnect switch to the unit. ALL UTD WIING MUST BE WEATHEPF. USE CPPE CNDUCTS NLY. FIGUE 6 : Typical Field Wiring ACCESSY WIING The electrical accessories available for this unit are a three stage thermostat, an optional De-humidification Control and a Fossil Fuel elay Kit for use in conjunction with furnace installation. efer to the individual instructions packaged with the accessories for installation. THEMSTAT MUNTING / WIING This heat pump must be installed with the factory recommended thermostat. The thermostat should be located about 5 ft. above the floor, where it will be exposed to normal room air circulation. Do not place it on an outside wall or where it is exposed to the radiant effect from exposed glass or appliances, drafts from outside doors or supply air grilles. After the thermostat is mounted, route the 24-volt control wiring (NEC Class 2) from the thermostat to the indoor air handler and outdoor unit. oute the control wiring into the grommeted hole in the bottom of control box of the outdoor unit to the 10 position terminal block. Connect leads to the screw terminals on the terminal block as shown in Figure 7. Interconnecting control wiring must be a minimum of No. 18 AWG color coded insulated wires. If total wire length (including thermostat, indoor unit, and outdoor unit) increases more than 90 feet, use No. 16 AWG wires to prevent excessive voltage drop. NTE: To eliminate erratic operation, seal the hole in the wall at the thermostat with permagum or equivalent to prevent air drafts affecting the anticipators in the thermostat. Unitary Products Group 7

DE-HUMIDIFICATIN CNTL A de-humidification control accessory 2HU06700124 may be used in high humidity areas. This control provides cooling at a reduced air flow, lowering evaporator temperature and increasing latent capacity. The humidistat in this control opens the humidistat contacts on humidity rise. To install, refer to instructions packaged with the accessory and Figure 7. Prior to the installation of the de-humidistat control, the jumper across the HUMIDISTAT terminals on the indoor variable speed air handler or furnace CFM selection board must be removed. During first or second stage cooling, if the relative humidity in the space is higher than the desired set point of the de-humidistat control, the variable speed blower motor will operate at lower speed until the de-humidification control is satisfied. A 40-60% relative humidity level is recommended to achieve optimum comfort. NTE: If a de-humidification control is installed, it is recommended that a minimum air flow of 325 cfm/ton (2-stage operation) be supplied at all times. FSSIL FUEL ELAY CNTL A Fossil Fuel elay Control accessory 2FF02700101 is required for use with all furnace applications. To install, refer to the instructions packed with the accessory. During a call for a third stage of heat, the fossil fuel relay will lock-out compressor operation and utilize furnace operation. This mode will continue until the room thermostat is satisfied. Upon thermostat satisfaction, the fossil fuel relay will de-energize and normal heat pump operation will be restored. FIELD CNNECTINS - CNTL WIING The recommended field connections for specified indoor air handlers and furnaces are shown in Figures 7 or 8. Feed all control wiring through the grommet in the bottom of the box. Variable Speed Air Handler Connections Shown in Figure 7 The first stage thermostat signal is connected to Y1 at the air handler. It is critical that the UT signal is connected to Y at the air handler to properly control the blower speed. Variable Speed Furnace Connections Shown in Figure 8 The first stage thermostat signal is connected to Y1 at the furnace. UT must be connected to Y at the furnace to properly control the blower speed. The Fossil Fuel elay Kit is required for all furnace applications. NTE: Figures 7 & 8 reflect wiring connections found on the recommended Honeywell thermostat (Non-Programmable 2ET03700524, Programmable 2ET03700624). When using the optional White odgers thermostat (2EP32U70124) W3 shown on the diagram should be replaced with W1. FIELD INSTALLED JUMPE WIE 2 STAGE CL 3 STAGE HEAT H/P T STAT L C Y1 W3 G E FIELD WIING VAIABLE SPEED AI HANDLE 1 X/L HUM C Y1 W2 W1 G Y 10 PS TEM BLCK FIGUE 7 : Typical Air Handler Thermostat Wiring FIELD INSTALLED JUMPE WIE UT PU BLK YEL ED GY G BN WHT ELAY BAD HEAT PUMP CNTL UT S2 S1 E/X B/C Y W2/60 W1/66 W 1 Y1,, X/L & HUM LCATED N CFM SELECTIN BAD 2 HUMIDISTAT CNTACTS PEN N HUMIDITY ISE. HUMIDISTAT JUMPE N CFM SELECTIN BAD MUST BE EMVED. 2 STAGE CL 3 STAGE HEAT H/P T STAT L C Y1 W3 G E FIELD WIING VAIABLE SPEED FUNACE HUM X/L C Y1 W2 W1 G Y 1 2 L C Y W2 W1 W 10 PS TEM BLCK L C Y W2 W1 W UT GN BLU BLK A YEL YEL GN BLU B YEL/GN 7 1 4 FSSIL FUEL ELAY PU BLK ED GY G BN WHT WHT HEAT PUMP CNTL WHT ELAY BAD S2 S1 E/X B/C Y W2/60 W1/66 W UT 1 HUMIDISTAT CNTACTS PEN N HUMIDITY ISE. HUMIDISTAT JUMPE N CFM SELECTIN BAD MUST BE EMVED. FIGUE 8 : Typical Furnace Thermostat Wiring 8 Unitary Products Group

CFM SELECTIN BAD SETTINGS CFM SELECTIN BAD TAP SELECTIN D C B A CL HEAT ADJ DELAY EMVE F HEAT PUMP HUMIDISTAT FIGUE 9 : CFM Selection Board For proper system operation the CFM Selection Board jumpers must be set properly. efer to the Tabular Data Sheet for the recommended air flow settings for each size condensing unit. Set the high speed cooling speed per the instructions for the air handler or furnace by selecting the correct CL and ADJ taps. The low speed setting will automatically be programmed for the correct airflow. Verify the airflow by LED display on the CFM selection board. The HEAT PUMP jumper MUST be removed for proper system operation. The HUMIDISTAT jumper must also be removed if a dehumidistat is installed. TANSFME INSTALLATIN This system requires the use of a 75VA transformer. Failure to install the 75VA transformer may result in premature system failure or damage to the equipment. The system transformer is typically located within the indoor air handler or furnace and is most commonly rated at 40VA. This heat pump comes from the factory with a 75VA transformer included. The transformer is located behind the compressor access panel and secured to the refrigerant piping. Cut the shipping strap and discard. The supplied transformer can be used with an air handler (208/230 V) or furnace (115 V). emove the indoor unit transformer and replace with the supplied 75VA transformer. Mounting hole locations may require modifications. Wire the new transformer per the indoor unit s wiring diagram. Give particular attention to the transformer primary voltage (230/208/115 V) and select the proper primary voltage terminals. Failure to utilize the appropriate transformer primary voltage tap will result in transformer damage and may result in system damage and/or failure. D C B A SYSTEM CHAGE The factory charge in the outdoor unit includes enough charge for the unit and the smallest matched coil. Additional charge may be required. EFIGEANT LINE CHAGES The outdoor condensing unit may be connected to the indoor evaporator coil using field supplied refrigerant grade copper tubing that is internally clean and dry. Units should be installed only with the tubing sizes for approved system combinations as specified in Tabular Data Sheet. The charge given is applicable for total tubing lengths up to 15 feet. See Application Data Form 690.01-AD1V for installing tubing of longer lengths and elevation differences. NTE: Using a larger than specified line size could result in oil return problems. Using a line size smaller than specified will result in loss of capacity and other problems caused by insufficient refrigerant flow. Table 2: EFIGEANT LINE CHAGES LIQUID D VAP D -22 CHAGE Z./FT. 3/8" 5/8" 0.66 3/8" 3/4" 0.68 3/8" 7/8" 0.70 3/8" 1-1/8" 0.76 Sweat connect units also include sufficient charge for 15 feet of lines. Table 2 lists the refrigerant line charges. The TTAL SYSTEM CHAGE must be permanently stamped on the unit data plate. Total system charge is determined as follows: 1. Determine outdoor unit charge from tabular data sheet. 2. Determine indoor coil adjustment from tabular data sheet. 3. Calculate the line charge with the factors in Table 2 for sweat lines in excess of 15 ft. NTE: The line charge over 15 feet should be included on the data plate and must be added to the system. 4. Total system charge = item 1 + item 2 + item 3. 5. Permanently stamp the unit data plate with the total amount of refrigerant in the system. USE THE FLLWING CHAGING METHD WHENEVE ADDITINAL EFIGEANT IS EQUIED F THE SYSTEM CHAGE. Measurement Method A calibrated charging cylinder or accurate weighing device must be used to add refrigerant. This is the only accurate charging method for heat pumps in the heat pump mode. Check flare caps on service ports to be sure they are leak tight. D NT VETIGHTEN (between 40 and 60 inch-lbs. maximum). Unitary Products Group 9

Subcooling Charging Method Table 3: -22 SATUATIN TEMPEATUE ST 1 1. 2. P 2 ST = Saturated Temperature P = Pressure ST 1 P 2 ST 1 P 2 90 168 105 211 120 260 91 171 106 214 121 264 92 174 107 217 122 267 93 177 108 220 123 271 94 179 109 223 124 274 95 182 110 226 125 278 96 185 111 230 126 282 97 188 112 233 127 286 98 190 113 236 128 289 99 193 114 240 129 293 100 196 115 243 130 297 101 199 116 246 131 301 102 202 117 250 132 305 103 205 118 253 133 309 104 208 119 257 134 313 The E*TS heat pump must only be used with the matching thermostatic expansion valve kit listed in the Tabular Data Sheet. The best way to check the system charge is by checking the system subcooling during the second stage cooling of operation. SEVICING AND VEIFY For second stage (2 cylinder) cooling operation, the recommended subcooling is 16 F. For first stage (1 cylinder) operation, the recommended subcooling is 10 F for all models. 1. Set the system running in the second stage cooling (2 cylinder operation) by setting the thermostat at least 6 F below the room temperature. 2. perate the system for a minimum of 15-20 minutes. 3. efer to the Tabular Data Sheet for the recommended airflow and verify this indoor airflow (it should be about 400 SCFM per ton during 2 cylinder operation). 4. Measure the liquid refrigerant pressure P and temperature T at the service valve. 5. Calculate the saturated liquid temperature ST from Table 3. 6. Subcooling temperature TC = Saturated Temperature (ST) - Liquid temp (T). Example: The pressure P and temperature T measured at the E*TS030 service port is 223 Psig and 93 F. From Table 3, the saturated temperature for 223 Psig is 109. The subcooling temperature TC = 109-93 = 16 F. Add charge if the calculated subcooling temperature TC in Step 6 is lower than the recommended level. emove and recover the refrigerant if the subcooling TC is higher than the recommended level. ENEGIZE CANKCASE HEATE This unit is equipped with a crankcase heater for the compressor. A warning label with an adhesive back is supplied in the unit installation instruction packet. This label should be attached to the field supplied disconnect switch where it will be easily seen. IMPTANT - An attempt to start the compressor without at least 8 hours of crankcase heat will damage the compressor. In order to energize the crankcase heater, set indoor two stage cooling thermostat to "FF" position. Close the line power disconnect to the unit. SYSTEM PEATIN This heat pump model is equipped with both YorkGuard V heat pump control and TS compressor control. The interface control 6CF board is used to bypass the first stage of heat when the outdoor temperature falls below certain temperatures. The TS control board is used only to switch between 1 and 2 cylinder operation. The fault codes and pressure switch on the TS control board are bypassed using the jumpers between the test and "PS" pins. 1. Anti-short Cycle Timer The five-minute time delay on YorkGuard V will be used to prevent the system from short cycling after the thermostat off or power interrupt. This time delay can be bypassed by temporarily shorting the test terminals on YorkGuard V for 3 seconds. Since a jumper was factory installed across the test pins on the TS control board, the anti-short cycle timer on the TS control board is bypassed. 2. First Stage Cooling This heat pump model is equipped with a Twin-Single compressor. With a call for first stage cooling, the compressor operates one cylinder. The run winding () is connected through the upper left contactor (A) and to the capacitor and the start winding (S) is connected to line voltage. The system operates at low discharge pressure and high suction pressure. See Figure 11. 3. Second Stage of Cooling With a call for second stage cooling, the TS control will shut the compressor off for two seconds then energize relays 1 and 2 on the TS control board. This will deenergize (open) the upper left contactor (A) and energize (close) the lower right contactor (B), connecting the compressor run winding () to the line voltage and start winding (S) to the capacitor. The compressor runs in the reverse direction with two cylinders compared to the first stage. The system will operate with two cylinders until both first and second stage are satisfied. The UT signal from the relay board causes the indoor blower to function at high speed. If the room thermostat calls for second stage cooling () on two consecutive cooling cycles, the next call for cooling for either first or second stage will energize the unit in second stage mode. The above mode will be reset to permit start up on the first stage with only a Y1 call when the second stage operation cycle runs less than 15 minutes or when 24V to the TS control board is disconnected. 10 Unitary Products Group

4. 6K elay on the 6CF Control Board The 6K relay on the 6CF interface board operates as follows. See Figure 10: a. If the YorkGuard V defrost control balance point setting is 45 F, the 6K relay will be: Energized if liquid temperature goes below 35 F. De-energized if the liquid temperature goes above 35 F AND the ambient is greater than 42 F for five minutes AND the unit is not in defrost. b. If the YorkGuard V defrost control balance point setting is at anything but 45 F, the 6K relay will be: Energized if liquid temperature goes below 45 F. De-energized if the liquid temperature goes above 45 F AND the ambient is greater than 55 F AND the unit is not in defrost. 5. Heating mode with the de-energized 6K relay The TS compressor operates similar to the first and second stage of cooling modes expect there is no input from the thermostat, the reversing valve is not energized, and the system operates in heating heat pump mode. The YorkGuard V control and the liquid temperature will not allow the system to go into the defrost mode. 6. Heating mode with the energized 6K elay The energized 6K relay on the interface board (6CF) will connect Y1 and and disconnect UT from the TS control to the indoor blower if the J1 pin is not in the N position. The compressor will operate only in second stage regardless of the first or second stage call from the thermostat. The indoor blower will operate in low air mode. The indoor discharge air temperature should be about 10 F hotter than a normal heat pump. If highspeed air is preferred, move J1 pin to the N position at the interface board (6CF). This will send the UT signal back to the indoor blower for the high speed air. NTE: High-speed air will lower discharge temperature approximately 10 F and increase the heating capacity approximately 10%. 6K NC FIGUE 10 : 6CF Interface Board Table 4: NMAL HEAT PUMP APPLICATIN SYSTEM MDE UT 6K N 6K TSTAT INPUTS NC J1 Y1 UT IND AI 24V () FM YKGUAD SYSTEM PEATIN 1st Cooling G, Y1, Lo Air 1st Stage 1 Cylinder 2nd Cooling G, Y1,, Hi Air 2nd Stage 2 Cylinders 1st Heating 1st Stage G, Y1 Lo Air De-energized 6K 1 Cylinder 2nd Heating 2nd Stage G, Y1, Hi Air De-energized 6K 2 Cylinders 1st Heating 2nd Stage G, Y1 Lo Air(*) Energized 6K 2 Cylinders 2nd Heating 2nd Stage G, Y1, Lo Air(*) Energized 6K 2 Cylinders Heating with Aux. Heat G, Y1,, W3 Indoor Air: Greater of High Cooling or High Heating (*) Move J1 pin to the N position at relay board, 6CF to obtain the high air speed. Unitary Products Group 11

LCKUT MDES A jumper is factory installed across the pressure switch connection on the TS control board (6CC). The system will use the entire lockout mode of the YorkGuard V. The YorkGuard V monitors system operation and will lockout the outdoor unit if it detects a malfunction. When a lockout occurs, the emergency heat light will flash at the thermostat and the fault indicator light on the YorkGuard V will flash the code, separated by a pause, indicating the failure mode as shown in Table 5. Table 5: FLASHING LIGHT CDES FAULT 2 3 4 5 6 7 8 1. FAILUE MDE Discharge Pressure reaches 400 +/- 10 PSIG Discharge temperature reaches approx. 275 F Discharge temp. did not reach approx. 90 F within 1hr. of compressor operation Two default defrosts within 1hr. Shorted 1 or shorted to ground 2 or opened 3 discharge sensor. Shorted 1 or shorted to ground 2 or opened 3 outdoor sensor. Shorted or shorted to ground or opened liquid sensor. Shorted or shorted to 9 ground bonnet sensor 9 pened bonnet sensor CLING MDE Not Applicable Not Applicable Not Applicable Not Applicable Not Applicable HEATING MDE Utilizes liquid sensor at end of each compressor off period. Use 30 time/ temp defrost back-up, 5 min. defrost time. Not Applicable Shorted - A resistance of less than 100 hm across a sensor terminal. 2. Shorted to ground - A resistance of 1 Mega hm or less to ground on either side of the sensor terminal. 3. pened - A resistance of over 200000 hm across a sensor terminal. The control can be reset from a fault or lockout condition and the X/L LED indicator on the thermostat cleared when any of the following conditions occur. 1. Power is interrupted and restored for at least two second. 2. The TEST terminal is connected through a 400 hm or less resistance for at least two seconds and then increased to 1.5K hm or greater. 3. r Y on the wall thermostat goes from an N-FF transition (valid for fault codes 2-5 only). NTE: The thermistor (codes 6-8 only) errors cannot be reset until the errors are corrected. If the fault code 2, 3, and 4 occur in a 12 hour period, the control will go into a hard lockout mode that can only be cleared by: 1. emoval of 24VAC control voltage or 2. Jump the TEST pin PEATIN BELW LW-TEMPEATUE CUT-FF At an outdoor temperature below the cut-off point, (See Figure 11) the compressor operation cannot be justified due to the small amount of heat generated. The YorkGuard senses this and performs the following functions: 1. De-energizes compressor circuit. 2. Changes the first step of supplemental heat so that it is controlled by the first stage of the thermostat along with the fan. 3. Energizes standby heat (if installed) under control of third stage of heating thermostat. PEATIN IN EMEGENCY HEAT PSITIN When switch on thermostat is placed in emergency heat position: 1. circuit is locked out. 2. Gas furnace or standby heaters (if installed) will be controlled by first stage of heating thermostat. 3. Indoor blower will operate on demand for heat and cycle off with the last heater element or furnace when in "AUT" position. SUPPLEMENTAL ELECTIC HEAT Supplemental electric heaters are energized by third stage of heating thermostat. YorkGuard V will permit operation of supplemental heaters below balance point. At all outdoor temperatures above balance point, supplemental heaters are not permitted to operate. PEATIN BELW BALANCE PINT: With third stage of heating thermostat contact closed, a circuit is made through YorkGuard V to energize the supplemental heaters. When third stage of heating thermostat becomes satisfied, contact will open to de-energize supplemental heaters. GAS FUNACE HEAT Gas furnace operation will occur at all temperatures below the low-temperature cut-out point or when there is a call for third stage heat. Gas furnace operation will also occur during the defrost cycle and if there is a call for emergency heat. DEFST CYCLE Frost and ice which forms on the outdoor coil during the heating cycle must be defrosted when it blocks the air flow through the coil. Due to the arrangement of the refrigerant circuit within the outdoor coil of these units, frost may accumulate unevenly in different sections of the coil. However, a normal defrost may occur even though the coil is not completely covered with frost. The YorkGuard V continuously monitors temperature sensors which measure outdoor ambient temperature and the temperature of the refrigerant liquid at the outdoor coil. When the relationship between these temperatures reaches a value which has been determined by the electronic control to be indicative of need for defrost, the defrost cycle is initiated provided the liquid sensor temperature is colder than 35 F. 12 Unitary Products Group

The YorkGuard V energizes the fan relay which stops the outdoor fan and energizes the reversing valve relay to switch the refrigerant circuit to cooling. YorkGuard V also energizes supplemental heat (either electric heat or fossil fuel) to prevent cold drafts in the conditioned space. The defrost cycle is terminated when: 1. The liquid line temperature exceeds 70 F, or, 2. 14 1/2 minutes from the initiation of the defrost cycle, or, 3. the liquid line reaches 45 F and holds above 45 F for a continuous 3 minutes. The YorkGuard V de-energizes the fan relay and reversing valve relay to return unit to normal heating cycle. S2 Y S1 LW TEMPEATUE CUT-FF ADJUSTMENT TEMP SELECT L/X B/C W2/60 W1/66 W TEST P2 LTC -10 0 10 20 25 30 35 40 45 W W1/66 W2/60 Y B/C L/X S1 S2 BAL PT P1 CM CM M PS EV VAL FIGUE 11 : YorkGuard V Control BALANCE PINT ADJUSTMENT INDICATINS F PPE CLING PEATIN Cooling operation is the same as any conventional air conditioning unit. 1. The outdoor fan should be running, with warm air being discharged from the top of the unit. 2. The indoor blower (furnace or air handler) will be operating, discharging cool air from the ducts, coils or other parts in the air circuit. Clean as often as necessary to keep the unit clean. Use a brush, vacuum cleaner attachment, or other suitable means. 3. The vapor line at the outdoor unit will feel cool to the touch. 4. The liquid line at the outdoor unit will feel warm to the touch. THEMISTS CNSTANT FLASH: NMAL P HIGH VLTAGE STATUS DIS D LL CND FAN INDICATINS F PPE HEATING PEATIN Indications of proper heating operation is as follows: 1. The outdoor fan should be running, with cool air being discharged from the top of the unit. 2. The indoor blower (furnace or air handler) will be operating, discharging warm air from the ducts. 3. The vapor line at the outdoor unit will feel warm to the touch. 4. The liquid line at the outdoor unit will feel cool to the touch. NTICE T WNE If lockout occurs, check the following before calling a service man: 1. Indoor section for dirty filter. 2. utdoor section for snow accumulation. 3. utdoor section for leaf or debris blockage. Eliminate problem, turn off the thermostat for 10 seconds and attempt start. Wait 5 minutes. If system does not start, call serviceman. MAINTENANCE 1. Dirt should not be allowed to accumulate on the outdoor coils or other parts in the air circuit. Clean as often as necessary to keep the unit clean. Use a brush, vacuum cleaner attachment, or other suitable means. 2. The outdoor fan motor is permanently lubricated and does not require periodic oiling. 3. If the coil needs to be cleaned, it should be washed with Calgon CalClean (mix one part CalClean to seven parts water). Allow solution to remain on coil for 30 minutes before rinsing with clean water. Solution should not be permitted to come in contact with painted surfaces. 4. efer to the furnace or air handler instructions for filter and blower motor maintenance. 5. The evaporator coil drain pan should be inspected and cleaned regularly to prevent odors and assure proper drainage. It is unlawful to knowingly vent, release or discharge refrigerant into open air. It is necessary to recover the refrigerant during any repair or installation of the system. WHEN THE SYSTEM IS FUNCTINING PPELY AND THE WNE HAS BEEN FULLY INSTUCTED, SECUE THE WNE'S APPVAL. Unitary Products Group 13

WIING DIAGAM FIGUE 12 : Wiring Diagram - Variable Speed Air Handler 14 Unitary Products Group

SEVICE ECDS Unitary Products Group 15

Subject to change without notice. Printed in U.S.A. 035-16472-002 ev. A (0803) Copyright by York International Corp. 2003. All rights reserved. Supersedes: 035-16472-001 ev. A (0302) Unitary 5005 Norman Products York K Group Drive 73069