MISCELLANEOUS ENGINEERING DATA EXPANSION VALVE CROSS-REFERENCE DATA PRODUCT SPECIFICATIONS

Similar documents
DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Performance and Reliability. CB*, C* and TA* Models

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

14 AC x

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

MERIT Series R-410A - Upflow / Horizontal

efficient solutions Air Handlers

HEALTHY CLIMATE PureAir Air Purification System

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

MERIT Series R-410A - Upflow / Horizontal

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

MERIT SERIES Up Flow / Horizontal

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

ASHRAE 90.1 COMPLIANT 6 to 36 Tons

ELITE Series R-410A - Two-Stage Compressor

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

The XC21 delivers the ultimate in comfort.

The XP21 raises the bar for efficiency and comfort.

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

INSTALLATION INSTRUCTIONS

Come home to perfectly quiet and efficient comfort.

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

ELITE Series Variable Capacity

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

An air conditioner that redefines comfort and efficiency.

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

The XC17 is an efficiency expert.

A heat pump that redefines comfort and efficiency.

complete comfort Heat Pumps

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

complete comfort Heat Pumps

XC21. XC21 Air Conditioner Up to 20.5 SEER. Home Comfort Systems. The most quiet and efficient central air conditioner you can buy*

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

13 GEP A L P - 1 A

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

WARNING This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

ustainable oils Built to Last!

2 shp 13 lc 1 36 t - 1 a

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

The XP17 provides comfort without comparison.

complete comfort Heat Pumps

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

complete comfort Heat Pumps

ELITE Series Variable Capacity

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Home Comfort Systems. g60v. The quietest furnace in its class*

EAC ELITE ELECTRONIC AIR CLEANER INDOOR AIR QUALITY ENGINEERING DATA FEATURES

ELITE SERIES Downflow - High Efficiency Blower Motor

Home Comfort Systems. The quietest furnace you can buy* and one of the most efficient! Featuring new Precise Comfort and AirFlex Technologies

CB X 32 mv

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

XP21 The most quiet and efficient heat pump you can buy*

MERIT SERIES Downflow

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Xc21 air conditioner up to seer Xc21

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

incomparably cool XC21 The most quiet and efficient central air conditioner you can buy*

COMMERCIAL HVAC PRODUCT GUIDE COMMERCIAL

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

T S A 048 S 4 N 4 1 T

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Heil Gas Furnace Air Conditioner Sp80 Manual READ ONLINE

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

complete comfort Heat Pumps

cool and comfortable Air Conditioners

up to 98.7% efficiency can save over $800 a year** The SLP98V is a choice you can feel good about.

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Transcription:

MISCELLANEOUS ENGINEERING DATA PRODUCT SPECIFICATIONS EXPANSION VALVE CROSS-REFERENCE DATA Bulletin No. 210729 July 2015 CROSS-REFERENCE SHOWING CURRENT AND ALTERNATE INDOOR EXPANSION VALVE MATCH-UPS - OUTDOOR UNITS AIR CONDITIONERS Current / Cooling Only /Check Valve 13ACX-018 12J18 37L51 49L24 13ACX-024 12J18 37L51 49L24 13ACX-030 12J18 37L51 49L24 13ACX-036 12J19 37L51 49L24 13ACX-042 12J20 39L72 49L25 13ACX-048 12J20 91M02 91M02 13ACX-060 12J20 91M02 91M02 14ACX-018 12J18 37L51 49L24 14ACX-024 12J18 37L51 49L24 14ACX-030 12J18 37L51 49L24 14ACX-036 12J19 39L72 49L24 14ACX-041 12J20 91M02 91M02 14ACX-042 12J20 91M02 91M02 14ACX-047 12J20 91M02 91M02 14ACX-048 12J20 91M02 91M02 14ACX-059 12J20 91M02 91M02 14ACX-060 12J20 91M02 91M02 XC13-018 12J18 37L51 49L24 XC13-024 12J18 37L51 49L24 XC13-030 12J18 37L51 49L24 XC13-036 12J19 37L51 49L24 XC13-042 12J20 39L72 49L25 XC13-048 12J20 91M02 91M02 XC13-060 12J20 91M02 91M02 XC14-018 12J18 37L51 49L24 XC14-024 12J18 37L51 49L24 XC14-030 12J18 37L51 49L24 XC14-036 12J19 39L72 49L25 XC14-041 12J20 91M02 91M02 XC14-042 12J20 91M02 91M02 XC14-047 12J20 91M02 91M02 XC14-048 12J20 91M02 91M02 XC14-060 12J20 91M02 91M02 AIR CONDITIONERS Current / Cooling Only /Check Valve XC16-024 12J18 37L51 49L24 XC16-036 12J19 37L51 49L24 XC16-048 12J20 91M02 91M02 XC16-060 12J20 91M02 91M02 XC17-024 12J18 37L51 49L24 XC17-030 12J18 37L51 49L24 XC17-036 12J19 39L72 49L25 XC17-042 12J20 39L72 49L25 XC17-048 12J20 91M02 91M02 XC17-060 12J20 91M02 91M02 SL18XC1-024 12J18 37L51 49L24 SL18XC1-030 12J18 37L51 49L24 SL18XC1-036 12J19 39L72 49L25 SL18XC1-042 12J20 39L72 49L25 SL18XC1-048 12J20 91M02 91M02 SL18XC1-060 12J20 91M02 91M02 XC20-024 12J18 37L51 49L24 XC20-036 12J19 37L51 49L24 XC20-048 12J20 91M02 91M02 XC20-060 12J20 91M02 91M02 XC21-024 12J18 37L51 49L24 XC21-036 12J19 91M02 91M02 XC21-048 12J20 91M02 91M02 XC21-060 12J20 91M02 91M02 XC25-024 12J18 37L51 49L24 XC25-036 12J19 37L51 49L24 XC25-048 12J20 91M02 91M02 XC25-060 12J20 91M02 91M02

CROSS-REFERENCE SHOWING CURRENT AND ALTERNATE INDOOR EXPANSION VALVE MATCH-UPS - OUTDOOR UNITS HEAT PUMPS Current / / 13HPX-018 12J18 49L24 13HPX-024 12J18 49L24 13HPX-030 12J18 49L24 13HPX-036 12J19 49L24 13HPX-042 12J20 49L25 13HPX-048 12J20 91M02 13HPX-060 12J20 91M02 14HPX-018 12J18 49L24 14HPX-024 12J18 49L24 14HPX-030 12J18 49L24 14HPX-036 12J19 49L25 14HPX-042 12J20 49L25 14HPX-048 12J20 91M02 14HPX-060 12J20 91M02 XP13-018 12J18 49L24 XP13-024 12J18 49L24 XP13-030 12J18 49L24 XP13-036 12J19 49L24 XP13-042 12J20 49L25 XP13-048 12J20 91M02 XP13-060 12J20 91M02 XP14-018 12J18 49L24 XP14-024 12J18 49L24 XP14-030 12J18 49L24 XP14-036 12J19 49L25 XP14-042 12J20 49L25 XP14-048 12J20 91M02 XP14-060 12J20 91M02 XP16-024 12J18 49L24 XP16-036 12J19 49L24 XP16-048 12J20 91M02 XP16-060 12J20 91M02 XP17-024 12J18 49L24 HEAT PUMPS Current / / XP17-030 12J18 49L25 XP17-036 12J19 91M02 XP17-042 12J20 91M02 XP17-048 12J20 91M02 XP17-060 12J20 91M02 SL18XP1-024 12J18 49L24 SL18XP1-030 12J18 49L25 SL18XP1-036 12J19 91M02 SL18XP1-042 12J20 91M02 SL18XP1-048 12J20 91M02 SL18XP1-060 12J20 91M02 XP20-024 12J18 49L24 XP20-036 12J19 49L24 XP20-048 12J20 91M02 XP20-060 12J20 91M02 XP21-024 12J18 49L24 XP21-036 12J19 91M02 XP21-048 12J20 91M02 XP21-060 12J20 91M02 XP25-024 12J18 49L24 XP25-036 12J19 49L24 XP25-048 12J20 91M02 XP25-060 12J20 91M02 Expansion Valve Cross-Reference Data / Page 2

CROSS-REFERENCE SHOWING CURRENT AND ALTERNATE INDOOR EXPANSION VALVE MATCH-UPS - INDOOR UNITS INDOOR COILS Indoor Coil Current / / CX34-18/24A-6F 12J18 49L24 CX34-18/24B-6F 12J18 49L24 CX34-18/24C-6F 12J18 49L24 CX34-19A-6F 12J18 49L24 CX34-25A-6F 12J18 49L24 CX34-25B-6F 12J18 49L24 CX34-30B-6F 12J18 49L24 CX34-30C-6F 12J18 49L24 CX34-31A-6F 12J18 49L24 CX34-31B-6F 12J18 49L24 CX34-36A-6F 12J19 49L24 CX34-36B-6F 12J19 49L24 CX34-36C-6F 12J19 49L24 CX34-38A-6F 12J19 49L24 CX34-38B-6F 12J19 49L24 CX34-42B-6F 12J20 49L25 CX34-43B-6F 12J20 49L25 CX34-43C-6F 12J20 49L25 CX34-44/48B-6F 12J20 49L25 CX34-44/48C-6F 12J20 49L25 CX34-49C-6F 12J20 91M02 CX34-50-60C-6F 12J20 91M02 CX34-60D-6F 12J20 91M02 CX34-62C-6F 12J20 91M02 CX34-62D-6F 12J20 91M02 CX35-18/24A-6F 12J18 49L24 CX35-18/24B-6F 12J18 49L24 CX35-24A-6F 12J18 49L24 CX35-24B-6F 12J18 49L24 CX35-30A-6F 12J18 49L24 CX35-30B-6F 12J18 49L24 CX35-30/36A-6F 12J19 49L25 CX35-30/36B-6F 12J19 49L25 CX35-30/36C-6F 12J19 49L25 CX35-36A-6F 12J19 49L25 CX35-36B-6F 12J19 49L25 CX35-48B-6F 12J20 91M02 CX35-48C-6F 12J20 91M02 CX35-49C-6F 12J20 91M02 CX35-50/60C-6F 12J20 91M02 CX35-60C-6F 12J20 91M02 CX35-60D-6F 12J20 91M02 CX34, CX35 upflow coils are shipped with a factory installed in most cases, no change out of the Valve is needed. If a change out is required it will be listed in the SUBSTITUTIONS AND ALTERNATE SUBSTITUTIONS table. The correct must be ordered separately and field installed. AIR HANDLERS Air Handler Current / / CBX25UH-018 12J18 49L24 CBX25UH-024 12J18 49L24 CBX25UH-030 12J18 49L24 CBX25UH-036 12J19 49L24 CBX25UH-042 12J20 91M02 CBX25UH-048 12J20 91M02 CBX25UH-060 12J20 91M02 CBX25UHV-018 12J18 49L24 CBX25UHV-024 12J18 49L24 CBX25UHV-030 12J18 49L24 CBX25UHV-036 12J19 49L24 CBX25UHV-042 12J20 91M02 CBX25UHV-048 12J20 91M02 CBX25UHV-060 12J20 91M02 CBX27UH-018 12J18 49L24 CBX27UH-024 12J18 49L24 CBX27UH-030 12J18 49L24 CBX27UH-036 12J19 49L24 CBX27UH-042 12J20 91M02 CBX27UH-048 12J20 91M02 CBX27UH-060 12J20 91M02 CBX32M-018/024 12J18 49L24 CBX32M-030 12J18 49L24 CBX32M-036 12J19 49L24 CBX32M-042 12J20 91M02 CBX32M-048 12J20 91M02 CBX32M-060 12J20 91M02 CBX32MV-018/024 12J18 49L24 CBX32MV-024/030 12J18 49L24 CBX32MV-036 12J19 49L24 CBX32MV-048 12J20 91M02 CBX32MV-060 12J20 91M02 CBX32MV-068 12J20 91M02 CBX40UHV-024 12J18 49L24 CBX40UHV-030 12J18 49L24 CBX40UHV-036 12J19 49L24 CBX40UHV-042 12J20 91M02 CBX40UHV-048 12J20 91M02 CBX40UHV-060 12J20 91M02 All all Lennox air handlers are shipped with a factory installed in most cases, no change out of the Valve is needed. If a change out is required it will be listed in the SUBSTITUTIONS AND ALTERNATE SUBSTITUTIONS table. The correct must be ordered separately and field installed. Expansion Valve Cross-Reference Data / Page 3

* SUBSTITUTION AND ALTERNATE SUBSTITUTIONS Indoor Coils/Air Handlers with factory installed expansion valves that require field replacement. AIR CONDITIONERS Outdoor Unit Indoor Coil or Air Handler Factory Cooling 13ACXN042 CX35-30 12J18 12J20 91M02 91M02 13ACX(-)(N)030 CX34-42 12J20 12J18 37L51 49L24 13ACX(-)(N)030 CX34-43 12J20 12J18 37L51 49L24 13ACX(-)(N)030 CX34-44/48 12J20 12J18 37L51 49L24 14ACX(-)(S)030 CX34-42 12J20 12J18 37L51 49L24 14ACX(-)(S)030 CX34-43 12J20 12J18 37L51 49L24 14ACX(-)(S)030 CX35-48 12J20 12J18 37L51 49L24 14ACX(-)(S)036 CX34-31 12J20 12J18 37L51 49L24 XC13N030 CX35-48 12J20 12J18 37L51 49L24 XC13N042 CX35-30/36 12J19 12J20 91M02 91M02 XC13(-)(N)030 CX34-42 12J20 12J18 37L51 49L24 XC13(-)(N)030 CX34-43 12J20 12J18 37L51 49L24 XC13(-)(N)030 CX34-44/48 12J20 12J18 37L51 49L24 XC13(-)(N)030 CX34-31 12J18 12J20 91M02 91M02 XC14-030 CX34-42 12J20 12J18 37L51 49L24 XC14-030 CX34-43 12J20 12J18 37L51 49L24 XC14-030 CX35-48 12J19 12J18 37L51 49L24 XC14-041 CX34-38 12J19 12J20 91M02 91M02 XC14-041 CX35-36 12J19 12J20 91M02 91M02 XC14-042 CX34-36 12J19 12J20 91M02 91M02 XC14-042 CX34-38 12J19 12J20 91M02 91M02 XC14-042 CX35-30/36 12J19 12J20 91M02 91M02 XC14-042 CX35-36 12J19 12J20 91M02 91M02 XC14(-)(S)036 CBX32M-030 12J18 12J19 39L72 49L25 XC14(-)(S)036 CX34-31 12J18 12J19 39L72 49L25 XC14(-)(S)036 CX35-30 12J18 12J19 39L72 49L25 XC16(-)(S)036 CBX25UHV-030 12J18 12J19 39L72 49L25 XC16(-)(S)036 CBX32MV-024/030 12J18 12J19 39L72 49L25 XC17-030 CX34-42 12J19 12J18 37L51 49L24 XC17-030 CX34-43 12J19 12J18 37L51 49L24 XC17-030 CX34-44/48 12J19 12J18 37L51 49L24 XC17-030 CX35-48 12J20 12J19 39L72 49L25 XC17-036 CBX32M-030 12J18 12J19 39L72 49L25 XC17-036 CX34-31 12J18 12J19 39L72 49L25 XC17-042 CBX32MV-036 12J19 12J20 91M02 91M02 XC17-042 CBX40UHV-036 12J19 12J20 91M02 91M02 XC17-042 CX34-38 12J19 12J20 91M02 91M02 XC17-042 CX35-36 12J19 12J20 91M02 91M02 XC21-024 CX34-42 12J20 12J18 37L51 49L24 XC21-036 CX35-48 12J20 12J18 37L51 49L24 XC21-048 CBX32MV-036 12J19 12J19 39L72 49L25 XC21-060 CBX40UHV-036 12J19 12J19 39L72 49L25 * CX34, CX35 coils and all air handlers - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed is used. Expansion Valve Cross-Reference Data / Page 4

* SUBSTITUTION AND ALTERNATE SUBSTITUTIONS Indoor Coils/Air Handlers with factory installed expansion valves that require field replacement. HEAT PUMPS Outdoor Unit Indoor Coil or Air Handler Factory 13HPX-042 CBX32MV-036 12J19 12J20 91M02 13HPX-042 CBX40UHV-36 12J19 12J20 91M02 14HPX-030 CX34-44/48 12J20 12J18 49L24 XP13-036 CBX40UHV-030 12J18 12J19 49L25 XP13-042 CBX32MV-036 12J19 12J20 91M02 XP13-042 CBX40UHV-036 12J19 12J20 91M02 XP14-030 CX34-42 12J20 12J18 49L24 XP14-030 CX34-43 12J20 12J18 49L24 XP14-030 CX34-44/48 12J20 12J18 49L24 XP17-030 CX34-43 12J20 12J18 49L24 XP17-042 CX34-38 12J19 12J20 91M02 XP21-024 CX34-38 12J19 12J18 49L24 * CX34 coils and all air handlers - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed is used. Expansion Valve Cross-Reference Data / Page 5

Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2015 Lennox Industries, Inc.