Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 24ACB7 Performancet 2---Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. INDUSTRY LEADING FEATURES / BENEFITS Efficiency S S S Sound S S S S Comfort S

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data. 24ACB7 Performancet Stage Air Conditioner with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

SERIES 15 HEAT PUMP WITH PURON

Product Data. Efficiency S S S Sound S Comfort S. S S S S S S Durability. WeatherArmort protection package: S S S

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S.

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126CNA PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1-1/2 TO 5 NOMINAL TONS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

INDUSTRY LEADING FEATURES 1-1/2 5 / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BA15NA SINGLE -STAGE AIR -CONDITIONER WITH PURONr REFRIGERANT 1-1/2 TO 5 TONS.

Product Data. 24AAA5 Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Efficiency

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 113A LegacytLine 13 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons (Sizes )

Product Data. CA16NW Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. CA14NA Single---Stage Air Conditioner with Puronr Refrigerant /2 To 5 Tons INDUSTRY LEADING FEATURES / BENEFITS.

R4H4. Product Specifications

Product Data. Efficiency S. S S Indoor air quality accessories available Comfort S System supports Edger Thermidistatt or standard

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

R4H4. Product Specifications

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

A 14 SEER Heat Pump with R---410A Refrigerant Series

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

N4H4. Product Specifications

Product Data. Efficiency. S S Reliability

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

N4A6. Product Specifications

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Efficiency

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

WCH5**4. Product Specifications

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Advance Product Data

Product Data. Efficiency

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

R 410A Ducted Horizontal Air Conditioner

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Advance Product Data

Advance Product Data

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Product Data. Efficiency

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

697C (60 HZ) Sizes 018 thru 060

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Product Data. Efficiency

Advance Product Data

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40QAC / 38HDR 40QAQ / 38QRR Ceiling---Suspended Duct Free Split System Sizes 018 to 060

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Product Data. FH4C Base Series Fan Coil Sizes 001 thru 004 AIR HANDLER TECHNOLOGY AT ITS FINEST

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MVC / 38MVC 40MVQ / 38MVQ High---Wall Duct Free Split System Sizes 009 to 024

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MKCB / 24AHA4 / 124ANS 40MKQB / 25HHA4 / 224ANS High---Wall Ductless Split System Sizes 18 to 32

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Transcription:

MODEL LEGACYT ERIE R-22 AIR CONDITIONER IZE 018 TO 060 1-1/2 TO 5 NOMINAL TON Installation Instructions TM INDUTRY LEADING FEATURE / BENEFIT Efficiency ound Comfort Reliability Durability 13 EER / 11.0 EER (Nominal) Microtube Technologyt refrigeration system Indoor air quality accessories available ound level as low as 74 dba Compressor sound blanket ystem supports Thermidistatt or standard thermostat controls TechAssistt with 6 step diagnostics at-a-glance Front -seating service valves croll compressor Internal pressure relief valve Internal thermal overload High pressure switch Low pressure switch Filter drier Balanced refrigeration system for maximum reliability DuraGuardt protection package: Applications Warranty olid, Durable sheet metal construction Louvered coil guard Baked -on, complete coverage, powder paint Color matched ceramic coated screws Longline - up to 250 ft. total equivalent length, up to 200 ft condenser above evaporator, or up to 80 ft. evaporator above condenser (ee Longline Guide for more information.) Low ambient (down to -20_F) with accessory kit 10 year limited compressor warranty 5 year limited parts warranty

MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 2 3 R N A 0 3 6 0 0 0 A Product Family 1=AC Tier EER Major eries Voltage Variations 2= Legacy 3=13 EER R=R---22 N= 208---230---1 or 208/230---1 A = tandard Cooling Capacity Open Open Open 0=Not Defined 0=Not Defined 0=Not Defined Minor- eries A= Original eries IO 9001:2000 REGITERED As an Energy tar Partner, Bryant Heating & Cooling ystems has determined that this product meets the ENERGY TAR guidelines for energy efficiency. Refer to the combination ratings in Product Data for system combinations that meet Energy tar guidelines. TANDARD FEATURE Feature 18 24 30 36 42 48 60 13 EER X X X X X X X croll Compressor X X X X X X X Compressor ound Hood X X X X X X X Louvered Coil Guard X X X X X X X FieldInstalledFilterDrier X X X X X X X Front eating ervice Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Low Pressure witch X X X X X X X High Pressure witch X X X X X X X TechAssistt Diagnostics At-a-Glance X X X X X X X 2

PHYICAL DATA UNIT IZE ERIE 018---A 024---A 030---A 036---A 042---A 048---A 060---A/B Operating Weight (lb) 140 144 158 177 219 265 271 hipping Weight (lb) 162 166 185 205 247 299 304 Compressor Type croll REFRIGERANT Freon (R --- 22) Control TXV (R --- 22 Hard hutoff) Charge (lb) 4.9 4.75 5.15 6.1 7.15 9.25 11.6/12.4 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty. (CFM) 1880 2200 3170 3170 4050 4050 4050 Motor HP 1/12 1/10 1/5 1/5 1/5 1/5 1/5 Motor RPM 1100 1100 800 800 800 800 800 COND COIL Face Area (q. ft.) 11.49 13.13 12.93 17.25 21.56 27.66 20.12 Fins per In. 25 25 25 25 25 25 20 Rows 1 1 1 1 1 1 2 Circuits 3 4 4 4 5 7 7 VALVECONNECT.(In.ID) Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBE* (In. OD) Vapor (0 ---80 ft. Tube Length) 5/8 3/4 7/8 1 --- 1/8 Liquid (0 ---80 ft. Tube Length) 3/8 * For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential (250 ft. Equivalent Length), consult the Longline Guideline. Note: ee unit Installation Instruction for proper installation. VAPOR LINE IZING AND COOLING CAPACITY LO 1-TAGE AIR CONDITIONER APPLICATION LONG LINE APPLICATION: An application is considered Long line when the total equivalent tubing length exceeds 80 ft. or when there is more than 20 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. The maximum vertical separation is 200 ft. when outdoor unit is above indoor unit, and up to 60 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. ee Long -Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss. Unit Nominal ize (Btuh) Acceptable Liquid Line Diameter (in. OD) Acceptable Vapor Line Diameter OD (in.) Cooling Capacity Loss (%) Equivalent Line Length (ft.) Long Line Application tandard Application Requires Accessories 25 50 80 80+ 100 125 150 175 200 225 250 18000 5/8 0 1 1 1 2 3 3 4 5 5 6 3/8 R --- 22 AC 3/4 0 0 0 0 0 1 1 1 1 2 2 5/8 0 1 3 3 3 5 6 7 8 9 10 24000 R --- 22 AC 3/8 3/4 0 0 0 0 1 1 1 2 2 3 3 7/8 0 0 0 0 0 0 0 0 1 1 1 5/8 1 3 5 5 6 8 10 11 13 15 17 30000 R --- 22 AC 3/8 3/4 0 1 1 1 2 3 3 4 5 5 6 7/8 0 0 0 0 1 1 1 2 2 2 3 36000 3/4 0 1 2 2 3 4 5 6 7 8 9 3/8 R --- 22 AC 7/8 0 0 1 1 1 2 2 3 3 4 4 3/4 1 2 3 3 4 5 7 8 9 10 11 42000 R --- 22 AC 3/8 7/8 0 1 1 1 2 2 3 4 4 5 5 11/8 0 0 0 0 0 0 0 1 1 1 1 3/4 1 2 4 4 5 7 8 10 11 13 14 48000 R --- 22 AC 3/8 7/8 0 1 2 2 2 3 4 5 5 6 7 11/8 0 0 0 0 0 0 1 1 1 1 1 60000 7/8 1 2 3 3 4 5 7 8 9 10 11 3/8 R --- 22 AC 11/8 0 0 1 1 1 1 2 2 2 3 3 tandard Length = 80 ft. or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit ee Long Line Application Guidelines 3

ACCEORY THERMOTAT THERMOTAT / UBBAE PKG. DECRIPTION TTATBBPRH01--- B Thermidistat Control --- Programmable / Non--- Programmable Thermostat with Humidity control TTATBBPAC01--- B Thermostat --- Auto Changeover, 7 --- Day Programmable, _F/_C, 1 --- tage Heat, 1 --- tage Cool TTATBBNAC01--- C Thermostat --- Auto Changeover, Non --- Programmable, _F/_C, 1 --- tage Heat, 1 --- tage Cool TTATBBBAC01--- B Builder s Thermostat --- Manual Changeover, Non--- Programmable, _F/_C, 1 --- tage Heat, 1 --- tage Cool TTATBBEN01---B Outdoor Air Temperature ensor TTATXXBBP01 Backplate for Builder s Thermostat TTATXXNBP01 Backplate for Non--- Programmable Thermostat TTATXXPBP01 Backplate for Programmable Thermostat TTATXXCNV10 Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack ACCEORIE ORDER NUMBER DECRIPTION 018---A 024---A 030---A 036---A 042---A 048---A 060---A 060---B KAACH1201AAA CRANKCAE HTR X X KAACH1401AAA CRANKCAE HTR X X X X KACY0101AAA CYCLE PROTECTOR X X X X X X X X KAAFT0101AAA FREEZE THERMOTAT X X X X X X X X KAH1501AAA HARD TART (CAP/RELAY) X X X X X X X KAH1701AAA HARD TART (CAP/RELAY) X KALA0201R22 LOW AMBIENT PW X X X X X X X X HC32GE234 MOTOR FAN BALL BEARING 230V X HC34GE239 MOTOR FAN BALL BEARING 230V X HC38GE228 MOTOR FAN BALL BEARING 230V X X HC40GE228 MOTOR FAN BALL BEARING 230V X X X X KALA0601AAA MOTORMATER 230V X X X X X X X X KAAL0101LL OLENOID VALVE X X X X X X X X KAAC0201PTC TARTAITPTC X X X X X X X X KAF0101AAA UPPORT FEET X X X X X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X X KATX0601HO TXV (HO) X X X X X KATX0701HO TXV (HO) X KATX1001HO TXV (HO) X X KAAW0101AAA WINTER TART X X X X X X X X = tandard X = Accessory 4

ACCEORY UAGE GUIDELINE ACCEORY REQUIRED FOR LOW---AMBIENT COOLING APPLICATION (Below 55 F) REQUIRED FOR LONG LINE APPLICATION* (Over 80 Ft.) REQUIRED FOR EA COAT APPLICATION (Within 2 miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Accumulator No No No Compressor tart Assist Capacitor and Relay Yes Yes No Motor Master Control or Low --- ambient Pressure witch Yes No No upport Feet Recommended No Recommended Liquid Line olenoid Valve No ee Long --- Line Application Guideline No Ball Bearing Fan Motor Yes{ No No Winter tart Control Yes} No No * For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differntial (250 ft. Equivalent Lenght), refer to Residential plit---ystem Longline Application Guideline. { Required for Low---Ambient Controller (full modulation feature) and MotorMasterr Control only. } Use only when low pressure switch is used. Accessory Description and Usage (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMasterr 2. Compressor tart Assist - Capacitor and Relay tart capacitor and relay gives a hard boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling uggested for all compressors in areas with a history of low voltage problems. 3. Compressor tart Assist PTC Type olid state electrical device which gives a soft boost to the compressor at each start -up. Usage Guideline: uggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. uggested in all commercial applications. 5. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5 -minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 6. Evaporator Freeze Thermostat An PT temperature-actuated switch that stops unit operation when evaporator reaches freeze -up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Low -Ambient Pressure witch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low -ambient temperatures down to 0_F when properly installed. Usage Guideline: A Low -Ambient Pressure witch or MotorMasterr Low -Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 8. MotorMasterr Low -Ambient Controller A fan -speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -20_F (-28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± - 1 2 _C). Usage Guideline: A MotorMasterr Low Ambient Controller or Low -Ambient Pressure witch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). uggested for all commercial applications. 9. Outdoor Air Temperature ensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: uggested for all Bryant thermostats listed in this publication. 5

Accessory Description and Usage (Listed Alphabetically) (Continued) 10. ound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by up to 2 dba. Usage Guideline: uggested when unit is installed closer than 15 ft to quiet areas, bedrooms, etc. uggested when unit is installed between two houses less than 10 ft apart. 11. upport Feet Four stick -on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: uggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 12. Thermostatic Expansion Valve (TXV) A modulating flow -control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor tart Assist Capacitor and Relay is required. Usage Guideline: Accessory required to meet ARI rating and system reliability, where indoor not equipped. Hard shut off TXV or LL required in air conditioner long line applications. Required for use on all zoning systems. 13. Time-Delay Relay An PT delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: Accessory required to meet ARI rating, where indoor not equipped. 14. Winter tart Control This control is designed to alleviate nuisance opening of the low -pressure switch by bypassing it for the first 3 minutes of operation. 6

ELECTRICAL DATA UNIT IZE --- ERIRE V/PH OPER VOLT* COMPR FAN MCA MIN WIRE IZE{ MIN WIRE IZE{ MAX LENGTH (FT)} MAX LENGTH (FT)} MAX MIN LRA RLA FLA 60 C 75 C 60 C 75 C MAX FUE** or CKT BRK AMP 018---A 40.3 7.7 0.5 10.3 14 14 76 73 15 024---A 54.0 10.4 0.75 13.8 14 14 57 54 20 030---A 68.0 14.1 1.2 18.8 14 14 42 40 30 036---A 77.0 14.4 1.2 19.2 12 12 65 62 30 208/230/1 253 197 042---A 104.0 19.2 1.2 25.2 10 10 79 75 40 048---A 137.0 20.2 1.2 26.4 10 10 76 72 40 060---A 141.0 25.3 1.2 32.9 8 8 96 91 50 060---B 150.0 25.0 1.2 32.5 8 8 96 91 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30 C(86 F), consult table 310---16 of the NEC (ANI/NFPA 70). The ampacity of non---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conditions, per the NEC (ANI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60 or 75 C (140 or 167 C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANI/NFPA 70). } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time --- Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA ---RatedLoadAmps NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. A-WEIGHTED OUND LEVEL (DBA) UNIT IZE TANDARD RATING TYPICAL OCTAVE BAND PECTRUM (without tone adjustment) 125 250 500 1000 2000 4000 8000 018---A 74 49.5 59.5 64.5 65.5 64.0 60.0 54.0 024---A 75 52.5 60.5 67.0 70.0 65.5 61.5 58.5 030---A 75 56.0 62.5 67.5 70.0 65.5 60.5 56.5 036---A 75 55.0 60.5 68.5 72.0 66.0 62.5 56.0 042---A 75 59.5 60.5 66.5 70.5 66.5 62.0 63.0 048---A 75 53.5 61.0 65.0 69.5 64.5 61.5 60.0 060---A 75 56.0 64.0 68.0 70.0 65.0 61.5 60.5 060---B 75 59.5 63.0 67.0 69.5 66.5 62.0 56.0 CHARGING UBCOOLING (TXV-TYPE EXPANION DEVICE) UNIT IZE---ERIE REQUIRED UBCOOLING (_F) 018---A 14 024---A 7 030---A 9 036---A 8 042---A 11 048---A 9 060---A 12 060---B 13 7

DIMENION 8

COMBINATION RATING Unit ize --- eries Factory upplied EER Indoor Model Cap. BTUH EER Furnace Model Enhancement tandard Rating TDR *CAR**1814A** 17,300 TXV 13.00 11.00 CAR**1814A** 17,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAR**2414A** 17,400 TDR&TXV 14.50 11.70 315(A,J)AV036070 CAR**2414A** 17,700 TXV 13.00 11.00 CAR**2417A** 17,400 TDR&TXV 15.00 12.00 315(A,J)AV048090 CAR**2417A** 17,400 TDR&TXV 14.50 11.70 355AAV042060 CAR**2417A** 17,700 TXV 13.00 11.00 CNRF*2418A** 17,700 TXV 13.00 11.00 CNRH*2417A** 17,400 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNRH*2417A** 17,400 TDR&TXV 15.00 12.00 315(A,J)AV048090 CNRH*2417A** 17,400 TDR&TXV 14.50 11.70 355AAV042040 CNRH*2417A** 17,400 TDR&TXV 15.00 12.00 355AAV042060 CNRH*2417A** 17,400 TDR&TXV 15.00 12.00 355AAV042080 CNRH*2417A** 17,700 TXV 13.00 11.00 CNRV*1814A** 17,000 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNRV*1814A** 17,300 TXV 13.00 11.00 018---A CNRV*2414A** 17,400 TDR&TXV 14.50 11.70 315(A,J)AV036070 CNRV*2414A** 17,700 TXV 13.00 11.00 CNRV*2417A** 17,400 TDR&TXV 15.00 12.00 315(A,J)AV048090 CNRV*2417A** 17,400 TDR&TXV 15.00 12.00 355AAV042060 CNRV*2417A** 17,700 TXV 13.00 11.00 CRH*2412A** 17,400 TDR&TXV 15.00 12.00 315(A,J)AV036070 CRH*2412A** 17,400 TDR&TXV 15.00 12.00 315(A,J)AV048090 CRH*2412A** 17,400 TDR&TXV 15.00 12.00 355AAV042040 CRH*2412A** 17,400 TDR&TXV 15.00 12.00 355AAV042060 CRH*2412A** 17,400 TDR&TXV 15.00 12.00 355AAV042080 CRH*2412A** 17,700 TXV 13.00 11.00 FA4CN(F,C)018 17,400 TDR&TXV 13.00 11.00 FA4CN(F,C)024 17,400 TDR&TXV 13.00 11.00 FC4DNF018 17,700 TDR&TXV 14.50 11.70 FC4DNF024 17,800 TDR&TXV 14.50 11.70 FF1ENE018 17,400 TDR&TXV 13.20 11.00 FF1ENE024 17,600 TDR&TXV 13.20 11.00 FK4DNF001 17,500 TDR&TXV 15.00 12.00 FK4DNF002 17,800 TDR&TXV 15.00 12.00 *CAR**2414A** 23,000 TXV 13.00 11.00 CAR**2414A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAR**2417A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV048090 CAR**2417A** 22,800 TDR&TXV 14.00 11.50 355AAV042060 CAR**2417A** 23,000 TXV 13.00 11.00 024---A CAR**3014A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAR**3014A** 23,200 TXV 13.00 11.00 CAR**3017A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV048090 CAR**3017A** 23,000 TDR&TXV 14.00 11.50 355AAV042060 CAR**3017A** 23,200 TXV 13.00 11.00 ee notes on pg. 17 CNRF*2418A** 23,000 TXV 13.00 11.00 9

COMBINATION RATING CONTINUED Unit ize --- eries Indoor Model Cap. BTUH Factory upplied Enhancement EER tandard Rating TDR EER Furnace Model CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRH*2417A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 355AAV042040 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 355AAV042060 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 355AAV042080 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 355AAV060080 CNRH*2417A** 23,000 TDR&TXV 14.00 11.50 355AAV060100 CNRH*2417A** 22,800 TDR&TXV 14.00 11.50 355AAV060120 CNRH*2417A** 23,000 TXV 13.00 11.00 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRH*3017A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV048090 CNRH*3017A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV060110 CNRH*3017A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV066135 CNRH*3017A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV066155 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV042040 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV042060 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV042080 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV060080 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV060100 CNRH*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV060120 CNRH*3017A** 23,200 TXV 13.00 11.00 CNRV*2414A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRV*2414A** 23,000 TXV 13.00 11.00 024---A CNRV*2417A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRV*2417A** 22,800 TDR&TXV 14.00 11.50 355AAV042060 CNRV*2417A** 23,000 TXV 13.00 11.00 CNRV*3014A** 22,800 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRV*3014A** 23,200 TXV 13.00 11.00 CNRV*3017A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV048090 CNRV*3017A** 23,000 TDR&TXV 14.00 11.50 355AAV042060 CNRV*3017A** 23,200 TXV 13.00 11.00 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CRH*2412A** 23,000 TDR&TXV 14.50 11.70 315(A,J)AV048090 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 355AAV042040 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 355AAV042060 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 355AAV042080 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 355AAV060080 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 355AAV060100 CRH*2412A** 23,000 TDR&TXV 14.00 11.50 355AAV060120 CRH*2412A** 23,000 TXV 13.00 11.00 ee notes on pg. 17 CRH*3012A** 23,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CRH*3012A** 23,200 TDR&TXV 14.50 11.70 315(A,J)AV048090 CRH*3012A** 23,200 TDR&TXV 14.00 11.50 315(A,J)AV060110 CRH*3012A** 23,200 TDR&TXV 14.50 11.70 315(A,J)AV066135 CRH*3012A** 23,200 TDR&TXV 14.50 11.70 315(A,J)AV066155 CRH*3012A** 23,200 TDR&TXV 14.00 11.50 355AAV042040 CRH*3012A** 23,000 TDR&TXV 14.00 11.50 355AAV042060 10

COMBINATION RATING CONTINUED Unit ize --- eries Indoor Model Cap. BTUH Factory upplied EER Enhancement tandard Rating TDR EER Furnace Model CRH*3012A** 23,200 TDR&TXV 14.00 11.50 355AAV042080 CRH*3012A** 23,200 TDR&TXV 14.00 11.50 355AAV060080 CRH*3012A** 23,200 TDR&TXV 14.00 11.50 355AAV060100 CRH*3012A** 23,000 TDR&TXV 14.00 11.50 355AAV060120 CRH*3012A** 23,200 TXV 13.00 11.00 024---A FA4CN(F,C)024 22,800 TDR&TXV 13.00 11.00 FA4CN(F,C)030 23,200 TDR&TXV 13.00 11.00 FC4DNF024 23,200 TDR&TXV 13.70 11.50 FC4DNF030 23,400 TDR&TXV 14.00 11.50 FF1ENE024 22,600 TDR&TXV 13.00 11.00 FF1ENE030 24,000 TDR&TXV 13.00 11.00 FK4DNF001 23,000 TDR&TXV 14.00 11.50 *CAR**3014A** 28,000 TXV 13.00 11.00 CAR**3014A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAR**3017A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CAR**3017A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CAR**3017A** 28,000 TXV 13.00 11.00 CAR**3614A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CAR**3614A** 28,400 TXV 13.00 11.00 CAR**3617A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV048090 CAR**3617A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CAR**3617A** 28,400 TXV 13.00 11.00 CAR**3621A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV060110 CAR**3621A** 28,200 TDR&TXV 14.00 11.50 355AAV042080 CAR**3621A** 28,200 TDR&TXV 14.00 11.50 355AAV060080 CAR**3621A** 28,200 TDR&TXV 14.50 11.70 355AAV060100 CAR**3621A** 28,200 TXV 13.00 11.00 CNRF*3618A** 28,400 TXV 13.00 11.00 030---A CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRH*3017A** 28,200 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRH*3017A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV066155 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV042040 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV042080 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV060080 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV060100 CNRH*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV060120 CNRH*3017A** 28,000 TXV 13.00 11.00 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRH*3617A** 28,200 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRH*3617A** 28,200 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRH*3617A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV066155 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV042040 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV042080 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV060080 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV060100 CNRH*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV060120 CNRH*3617A** 28,400 TXV 13.00 11.00 ee notes on pg. 17 11

COMBINATION RATING CONTINUED Unit ize --- eries Factory upplied EER Indoor Model Cap. BTUH EER Furnace Model Enhancement tandard Rating TDR CNRV*3014A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRV*3014A** 28,000 TXV 13.00 11.00 CNRV*3017A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRV*3017A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CNRV*3017A** 28,000 TXV 13.00 11.00 CNRV*3617A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRV*3617A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CNRV*3617A** 28,400 TXV 13.00 11.00 030---A CNRV*3621A** 28,200 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRV*3621A** 28,000 TDR&TXV 14.00 11.50 355AAV042080 CNRV*3621A** 28,000 TDR&TXV 14.00 11.50 355AAV060080 CNRV*3621A** 28,000 TDR&TXV 14.00 11.50 355AAV060100 CNRV*3621A** 28,200 TXV 13.00 11.00 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CRH*3012A** 28,000 TDR&TXV 14.50 11.70 315(A,J)AV066155 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 355AAV042040 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 355AAV042060 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 355AAV042080 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 355AAV060080 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 355AAV060100 CRH*3012A** 28,000 TDR&TXV 14.00 11.50 355AAV060120 CRH*3012A** 28,400 TXV 13.00 11.00 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV036070 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV048090 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV060110 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV066135 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 315(A,J)AV066155 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 355AAV042040 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 355AAV042060 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 355AAV042080 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 355AAV060080 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 355AAV060100 CRH*3612A** 28,200 TDR&TXV 14.50 11.70 355AAV060120 CRH*3612A** 28,400 TXV 13.00 11.00 FA4CN(F,C)030 28,000 TDR&TXV 13.00 11.00 FA4CN(F,C)036 28,200 TDR&TXV 13.00 11.00 FC4DN(F,B)036 28,600 TDR&TXV 14.00 11.50 FC4DNF030 28,400 TDR&TXV 14.00 11.50 FF1ENE030 28,000 TDR&TXV 13.00 11.00 FF1ENE036 28,200 TDR&TXV 13.00 11.00 FK4DNF001 28,000 TDR&TXV 14.00 11.50 FK4DNF002 28,400 TDR&TXV 14.50 11.70 FK4DNF003 28,400 TDR&TXV 14.50 11.70 FK4DNF005 29,200 TDR&TXV 15.00 12.00 FK4DNF002 23,400 TDR&TXV 14.50 11.70 FK4DNF003 23,200 TDR&TXV 14.50 11.70 *CAR**3617A** 34,000 TXV 13.00 11.00 036---A CAR**3614A** 33,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CAR**3614A** 33,000 TXV 13.00 11.00 ee notes on pg. 17 CAR**3617A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 12

COMBINATION RATING CONTINUED Unit ize --- eries Factory upplied EER Indoor Model Cap. BTUH EER Furnace Model Enhancement tandard Rating TDR CAR**3617A** 34,000 TDR&TXV 14.00 11.50 355AAV042060 CAR**3621A** 34,200 TDR&TXV 14.00 11.50 315(A,J)AV060110 CAR**3621A** 33,800 TDR&TXV 13.50 11.20 355AAV042080 CAR**3621A** 34,000 TDR&TXV 14.00 11.50 355AAV060080 CAR**3621A** 34,000 TDR&TXV 14.00 11.50 355AAV060100 CAR**3621A** 34,000 TXV 13.00 11.00 CAR**4221A** 34,400 TDR&TXV 14.00 11.50 315(A,J)AV060110 CAR**4221A** 34,200 TDR&TXV 13.50 11.20 355AAV042080 CAR**4221A** 34,200 TDR&TXV 14.00 11.50 355AAV060080 CAR**4221A** 34,400 TDR&TXV 14.00 11.50 355AAV060100 CAR**4221A** 34,600 TXV 13.00 11.00 CAR**4224A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV066135 CAR**4224A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV066155 CAR**4224A** 34,200 TDR&TXV 14.00 11.50 355AAV042040 CAR**4224A** 34,200 TDR&TXV 14.00 11.50 355AAV060120 CAR**4224A** 34,600 TXV 13.00 11.00 CNRF*3618A** 34,200 TXV 13.00 11.00 036---A CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 315(A,J)AV036070 CNRH*3617A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRH*3617A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRH*3617A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRH*3617A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV042040 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV042060 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV042080 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV060080 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV060100 CNRH*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV060120 CNRH*3617A** 34,000 TXV 13.00 11.00 CNRH*4221A** 34,400 TDR&TXV 14.00 11.50 315(A,J)AV036070 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV048090 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV060110 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV066135 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV066155 CNRH*4221A** 34,400 TDR&TXV 14.00 11.50 355AAV042040 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 355AAV042060 CNRH*4221A** 34,200 TDR&TXV 14.00 11.50 355AAV042080 CNRH*4221A** 34,400 TDR&TXV 14.00 11.50 355AAV060080 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 355AAV060100 CNRH*4221A** 34,400 TDR&TXV 14.50 11.70 355AAV060120 CNRH*4221A** 34,600 TXV 13.00 11.00 CNRV*3617A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRV*3617A** 33,800 TDR&TXV 13.50 11.20 355AAV042060 CNRV*3617A** 34,000 TXV 13.00 11.00 CNRV*3621A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRV*3621A** 33,800 TDR&TXV 13.50 11.20 355AAV042080 CNRV*3621A** 34,000 TDR&TXV 13.50 11.20 355AAV060080 CNRV*3621A** 34,000 TDR&TXV 13.50 11.20 355AAV060100 CNRV*3621A** 34,000 TXV 13.00 11.00 ee notes on pg. 17 CNRV*4221A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV060110 CNRV*4221A** 34,200 TDR&TXV 14.00 11.50 355AAV042080 CNRV*4221A** 34,400 TDR&TXV 14.00 11.50 355AAV060080 13

COMBINATION RATING CONTINUED Unit ize --- eries Factory upplied EER Indoor Model Cap. BTUH EER Furnace Model Enhancement tandard Rating TDR CNRV*4221A** 34,400 TDR&TXV 14.50 11.70 355AAV060100 CNRV*4221A** 34,600 TXV 13.00 11.00 036---A CRH*3612A** 34,000 TDR&TXV 14.00 11.50 315(A,J)AV036070 CRH*3612A** 34,000 TDR&TXV 14.50 11.70 315(A,J)AV048090 CRH*3612A** 34,000 TDR&TXV 14.50 11.70 315(A,J)AV060110 CRH*3612A** 34,000 TDR&TXV 14.50 11.70 315(A,J)AV066135 CRH*3612A** 34,000 TDR&TXV 14.50 11.70 315(A,J)AV066155 CRH*3612A** 34,000 TDR&TXV 14.00 11.50 355AAV042040 CRH*3612A** 34,000 TDR&TXV 14.00 11.50 355AAV042060 CRH*3612A** 34,000 TDR&TXV 14.00 11.50 355AAV042080 CRH*3612A** 34,000 TDR&TXV 14.00 11.50 355AAV060080 CRH*3612A** 34,000 TDR&TXV 14.00 11.50 355AAV060100 CRH*3612A** 34,000 TDR&TXV 14.00 11.50 355AAV060120 CRH*3612A** 34,000 TXV 13.00 11.00 CRH*4212A** 34,400 TDR&TXV 14.00 11.50 315(A,J)AV036070 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV048090 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV060110 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV066135 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 315(A,J)AV066155 CRH*4212A** 34,400 TDR&TXV 14.00 11.50 355AAV042040 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 355AAV042060 CRH*4212A** 34,400 TDR&TXV 14.00 11.50 355AAV042080 CRH*4212A** 34,400 TDR&TXV 14.00 11.50 355AAV060080 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 355AAV060100 CRH*4212A** 34,400 TDR&TXV 14.50 11.70 355AAV060120 CRH*4212A** 34,600 TXV 13.00 11.00 FA4CN(F,C)036 34,200 TDR&TXV 13.00 11.00 FA4CN(F,C)042 35,000 TDR&TXV 13.00 11.00 FC4DN(F,B)036 34,800 TDR&TXV 14.00 11.50 FC4DN(F,B)042 35,000 TDR&TXV 14.00 11.50 FF1ENE036 34,200 TDR&TXV 13.00 11.00 FK4DNB006 35,600 TDR&TXV 15.00 12.00 FK4DNF001 33,800 TDR&TXV 13.50 11.20 FK4DNF002 34,000 TDR&TXV 14.00 11.50 FK4DNF003 34,400 TDR&TXV 14.50 11.70 FK4DNF005 35,000 TDR&TXV 15.00 12.00 *CAR**4221A** 40,500 TXV 13.00 11.00 CAR**4221A** 40,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 CAR**4221A** 40,000 TDR&TXV 13.50 11.20 355AAV042080 CAR**4221A** 40,000 TDR&TXV 13.50 11.20 355AAV060080 CAR**4221A** 40,000 TDR&TXV 13.50 11.20 355AAV060100 042---A CAR**4224A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV066135 CAR**4224A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV066155 CAR**4224A** 40,000 TDR&TXV 13.50 11.20 355AAV042040 CAR**4224A** 40,000 TDR&TXV 13.50 11.20 355AAV060120 CAR**4224A** 40,500 TXV 13.00 11.00 CAR**4817A** 40,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CAR**4817A** 39,500 TDR&TXV 13.50 11.20 355AAV042060 CAR**4817A** 40,500 TXV 13.00 11.00 CAR**4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CAR**4821A** 40,500 TDR&TXV 13.50 11.20 355AAV042080 CAR**4821A** 41,000 TDR&TXV 13.50 11.20 355AAV060080 CAR**4821A** 41,000 TDR&TXV 14.00 11.50 355AAV060100 CAR**4821A** 41,500 TXV 13.00 11.00 ee notes on pg. 17 14

COMBINATION RATING CONTINUED Unit ize --- eries Indoor Model Cap. BTUH Factory upplied EER Enhancement tandard Rating TDR EER Furnace Model CAR**4824A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CAR**4824A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CAR**4824A** 40,500 TDR&TXV 13.50 11.20 355AAV042040 CAR**4824A** 41,000 TDR&TXV 14.00 11.50 355AAV060120 CAR**4824A** 41,500 TXV 13.00 11.00 CNRF*4818A** 41,000 TXV 13.00 11.00 CNRH*4221A** 40,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CNRH*4221A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRH*4221A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRH*4221A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRH*4221A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRH*4221A** 40,000 TDR&TXV 13.50 11.20 355AAV042040 CNRH*4221A** 40,500 TDR&TXV 13.50 11.20 355AAV042060 CNRH*4221A** 40,000 TDR&TXV 13.50 11.20 355AAV042080 CNRH*4221A** 40,500 TDR&TXV 13.50 11.20 355AAV060080 CNRH*4221A** 40,500 TDR&TXV 14.00 11.50 355AAV060100 CNRH*4221A** 40,500 TDR&TXV 14.00 11.50 355AAV060120 CNRH*4221A** 40,500 TXV 13.00 11.00 042---A CNRH*4821A** 41,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CNRH*4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV048090 CNRH*4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRH*4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRH*4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRH*4821A** 41,000 TDR&TXV 13.50 11.20 355AAV042040 CNRH*4821A** 41,000 TDR&TXV 13.50 11.20 355AAV042060 CNRH*4821A** 41,000 TDR&TXV 13.50 11.20 355AAV042080 CNRH*4821A** 41,000 TDR&TXV 13.50 11.20 355AAV060080 CNRH*4821A** 41,000 TDR&TXV 14.00 11.50 355AAV060100 CNRH*4821A** 41,000 TDR&TXV 14.00 11.50 355AAV060120 CNRH*4821A** 41,500 TXV 13.00 11.00 CNRV*4221A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRV*4221A** 40,000 TDR&TXV 13.50 11.20 355AAV042080 CNRV*4221A** 40,500 TDR&TXV 13.50 11.20 355AAV060080 CNRV*4221A** 40,500 TDR&TXV 14.00 11.50 355AAV060100 CNRV*4221A** 40,500 TXV 13.00 11.00 CNRV*4821A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV060110 CNRV*4821A** 40,500 TDR&TXV 13.50 11.20 355AAV042080 CNRV*4821A** 41,000 TDR&TXV 13.50 11.20 355AAV060080 CNRV*4821A** 41,000 TDR&TXV 14.00 11.50 355AAV060100 CNRV*4821A** 41,500 TXV 13.00 11.00 CNRV*4824A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRV*4824A** 41,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRV*4824A** 40,500 TDR&TXV 13.50 11.20 355AAV042040 CNRV*4824A** 41,000 TDR&TXV 14.00 11.50 355AAV060120 CNRV*4824A** 41,500 TXV 13.00 11.00 ee notes on pg. 17 CRH*4212A** 40,500 TDR&TXV 13.50 11.20 315(A,J)AV036070 CRH*4212A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV048090 CRH*4212A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV060110 CRH*4212A** 40,500 TDR&TXV 14.00 11.50 315(A,J)AV066135 CRH*4212A** 41,500 TDR&TXV 14.00 11.50 315(A,J)AV066155 CRH*4212A** 40,000 TDR&TXV 13.50 11.20 355AAV042040 CRH*4212A** 40,000 TDR&TXV 13.50 11.20 355AAV042060 CRH*4212A** 40,500 TDR&TXV 13.50 11.20 355AAV042080 CRH*4212A** 40,500 TDR&TXV 13.50 11.20 355AAV060080 15

COMBINATION RATING CONTINUED Unit ize --- eries Indoor Model Cap. BTUH Factory upplied EER Enhancement tandard Rating TDR EER Furnace Model CRH*4212A** 40,500 TDR&TXV 14.00 11.50 355AAV060100 CRH*4212A** 40,500 TDR&TXV 14.00 11.50 355AAV060120 CRH*4212A** 40,500 TXV 13.00 11.00 042---A CRH*4812A** 41,000 TDR&TXV 13.50 11.20 315(A,J)AV036070 CRH*4812A** 41,500 TDR&TXV 14.00 11.50 315(A,J)AV048090 CRH*4812A** 41,500 TDR&TXV 14.00 11.50 315(A,J)AV060110 CRH*4812A** 41,500 TDR&TXV 14.00 11.50 315(A,J)AV066135 CRH*4812A** 41,500 TDR&TXV 14.00 11.50 315(A,J)AV066155 CRH*4812A** 41,000 TDR&TXV 13.50 11.20 355AAV042040 CRH*4812A** 41,000 TDR&TXV 13.50 11.20 355AAV042060 CRH*4812A** 41,000 TDR&TXV 13.50 11.20 355AAV042080 CRH*4812A** 41,000 TDR&TXV 13.50 11.20 355AAV060080 CRH*4812A** 41,500 TDR&TXV 14.00 11.50 355AAV060100 CRH*4812A** 41,000 TDR&TXV 14.00 11.50 355AAV060120 CRH*4812A** 41,500 TXV 13.00 11.00 FA4CN(F,C)042 41,000 TDR&TXV 13.00 11.00 FA4CN(F,C)048 41,500 TDR&TXV 13.00 11.00 FC4DN(F,B)042 41,500 TDR&TXV 13.50 11.20 FC4DN(F,B)048 42,500 TDR&TXV 14.00 11.50 FK4DNB006 42,500 TDR&TXV 15.00 12.00 FK4DNF003 40,000 TDR&TXV 14.00 11.50 FK4DNF005 42,000 TDR&TXV 14.50 11.70 *CAR**4821A** 46,000 TXV 13.00 11.00 CAR**4817A** 45,000 TDR&TXV 13.50 11.20 315(A,J)AV048090 CAR**4817A** 45,000 TXV 13.00 11.00 CAR**4821A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 CAR**4821A** 45,500 TDR&TXV 13.20 11.00 355AAV060080 CAR**4821A** 45,500 TDR&TXV 13.20 11.00 355AAV060100 CAR**4824A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV066135 CAR**4824A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV066155 CAR**4824A** 45,500 TDR&TXV 13.50 11.20 355AAV060120 CAR**4824A** 46,500 TXV 13.00 11.00 048---A CAR**6021A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV060110 CAR**6021A** 45,500 TDR&TXV 13.50 11.20 355AAV060080 CAR**6021A** 46,000 TDR&TXV 13.50 11.20 355AAV060100 CAR**6021A** 47,000 TXV 13.00 11.00 CAR**6024A** 47,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CAR**6024A** 47,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CAR**6024A** 46,500 TDR&TXV 13.50 11.20 355AAV060120 CAR**6024A** 48,000 TXV 13.00 11.00 CNRF*4818A** 45,500 TXV 13.00 11.00 CNRH*4821A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV048090 CNRH*4821A** 45,500 TDR&TXV 13.50 11.20 355AAV060080 CNRH*4821A** 46,000 TXV 13.00 11.00 CNRH*6024A** 46,500 TDR&TXV 13.50 11.20 315(A,J)AV048090 CNRH*6024A** 46,500 TDR&TXV 14.00 11.50 355AAV060080 CNRH*6024A** 47,500 TXV 13.00 11.00 ee notes on pg. 17 CNRV*4821A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV060110 CNRV*4821A** 45,500 TDR&TXV 13.50 11.20 355AAV060080 CNRV*4821A** 45,500 TDR&TXV 13.50 11.20 355AAV060100 16

COMBINATION RATING CONTINUED Unit ize --- eries Factory upplied EER Indoor Model Cap. BTUH EER Enhancement tandard Rating TDR CNRV*4821A** 46,000 TXV 13.00 11.00 Furnace Model CNRV*4824A** 46,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRV*4824A** 46,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRV*4824A** 45,500 TDR&TXV 13.50 11.20 355AAV060120 CNRV*4824A** 46,500 TXV 13.00 11.00 CNRV*6024A** 47,000 TDR&TXV 14.00 11.50 315(A,J)AV066135 CNRV*6024A** 47,000 TDR&TXV 14.00 11.50 315(A,J)AV066155 CNRV*6024A** 46,500 TDR&TXV 13.50 11.20 355AAV060120 CNRV*6024A** 47,500 TXV 13.00 11.00 048---A CRH*4812A** 45,500 TDR&TXV 13.50 11.20 315(A,J)AV048090 CRH*4812A** 45,500 TDR&TXV 13.50 11.20 355AAV060080 CRH*4812A** 46,000 TXV 13.00 11.00 CRH*6012A** 46,000 TDR&TXV 13.50 11.20 315(A,J)AV048090 CRH*6012A** 46,000 TDR&TXV 13.50 11.20 355AAV060080 CRH*6012A** 47,000 TXV 13.00 11.00 FA4CN(F,C)048 47,000 TDR&TXV 13.00 11.00 FA4CN(F,C)060 48,000 TDR&TXV 13.20 11.00 FC4DN(F,B)048 47,500 TDR&TXV 13.50 11.20 FC4DN(F,B)060 49,000 TDR&TXV 14.20 11.70 FK4DNB006 48,000 TDR&TXV 14.50 11.70 FK4DNF005 47,000 TDR&TXV 14.00 11.50 *CAR**6024A** 57,000 TXV 13.00 11.00 CAR**6021A** 56,000 TXV 13.00 11.00 060---A,B CNRH*6024A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV066135 CNRH*6024A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV066155 CNRH*6024A** 57,000 TXV 13.00 11.00 CNRV*6024A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV066135 CNRV*6024A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV066155 CNRV*6024A** 57,000 TXV 13.00 11.00 CRH*6012A** 56,000 TDR&TXV 13.00 11.00 315(A,J)AV060110 CRH*6012A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV066135 CRH*6012A** 56,000 TDR&TXV 13.20 11.00 315(A,J)AV066155 CRH*6012A** 57,000 TXV 13.00 11.00 FA4CN(F,C)060 56,500 TDR&TXV 13.00 11.20 FC4DN(F,B)060 57,500 TDR&TXV 13.20 11.00 FK4DNB006 57,000 TDR&TXV 13.50 11.20 * Tested combination { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR. EER Energy Efficiency Ratio EER easonal Energy Efficiency Ratio TDR Time --- Delay Relay TXV Thermostatic Expansion Valve NOTE: 1. Ratings are net values reflecting the effects of circulating fan motor heat. upplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. 17

DETAILED COOLING CAPACITIE EVAPORATOR AIR CFM EWB Capacity ys- CONDENER ENTERING AIR TEMPERATURE deg F 75 85 95 105 115 Capacity ystem Capacity ys- Capacity ys- Capacity ens tem KW** ens KW** ens tem KW** ens tem KW** ens NA018---A Outdoor ection With CAR**1814A** Indoor ection 525 600 675 ystem KW** 72 20.66 10.90 1.23 19.73 10.55 1.34 18.83 10.20 1.47 17.96 9.88 1.62 17.14 9.58 1.80 67 18.45 13.22 1.24 17.58 12.86 1.35 16.74 12.51 1.47 15.94 12.18 1.62 15.19 11.88 1.79 62 16.67 15.55 1.24 15.90 15.16 1.35 15.16 14.78 1.47 14.49 14.40 1.61 13.93 13.93 1.77 57 16.31 16.31 1.24 15.68 15.68 1.35 15.06 15.06 1.47 14.48 14.48 1.61 13.93 13.93 1.77 72 21.12 11.48 1.25 20.15 11.12 1.37 19.21 10.77 1.50 18.30 10.44 1.65 17.45 10.13 1.83 67 18.87 14.13 1.26 17.97 13.76 1.37 17.10 13.41 1.50 16.27 13.07 1.65 15.50 12.76 1.82 62 17.19 16.73 1.27 16.43 16.29 1.38 15.76 15.76 1.50 15.14 15.14 1.64 14.55 14.55 1.81 57 17.08 17.08 1.27 16.41 16.41 1.38 15.76 15.76 1.50 15.14 15.14 1.64 14.55 14.55 1.81 72 21.46 12.02 1.27 20.46 11.65 1.39 19.48 11.30 1.52 18.55 10.97 1.68 17.67 10.66 1.85 67 19.20 14.99 1.29 18.28 14.62 1.40 17.38 14.25 1.53 16.53 13.91 1.67 15.74 13.59 1.84 62 17.72 17.72 1.29 17.03 17.03 1.40 16.34 16.34 1.53 15.69 15.69 1.67 15.07 15.07 1.84 57 17.74 17.74 1.29 17.03 17.03 1.40 16.34 16.34 1.53 15.69 15.69 1.67 15.07 15.07 1.84 Cooling Indoor Model Capacity Power Furnace Model *CAR**1814A** 1.00 1.00 CAR**2414A** 1.02 1.02 CAR**2417A** 1.02 1.02 CNRF*2418A** 1.02 1.02 CNRH*2417A** 1.02 1.02 CNRV*1814A** 1.00 1.00 CNRV*2414A** 1.02 1.02 CNRV*2417A** 1.02 1.02 CRH*2412A** 1.02 1.02 FA4CN(F,C)018 1.01 1.01 FA4CN(F,C)024 1.01 1.01 FC4DNF018 1.02 0.96 FC4DNF024 1.03 0.97 FF1ENE018 1.01 1.01 FF1ENE024 1.02 1.02 FK4DNF001 1.01 0.93 FK4DNF002 1.03 0.94 ee notes on pg. 24 Cooling Indoor Model Capacity Power Furnace Model CAR**1814A** 0.98 0.94 315(A,J)AV036070 CAR**2414A** 1.01 0.95 315(A,J)AV036070 CNRH*2417A** 1.01 0.95 315(A,J)AV036070 CNRV*1814A** 0.98 0.92 315(A,J)AV036070 CNRV*2414A** 1.01 0.95 315(A,J)AV036070 CRH*2412A** 1.01 0.92 315(A,J)AV036070 CAR**2417A** 1.01 0.92 315(A,J)AV048090 CNRH*2417A** 1.01 0.92 315(A,J)AV048090 CNRV*2417A** 1.01 0.92 315(A,J)AV048090 CRH*2412A** 1.01 0.92 315(A,J)AV048090 CNRH*2417A** 1.01 0.95 355AAV042040 CRH*2412A** 1.01 0.92 355AAV042040 CAR**2417A** 1.01 0.95 355AAV042060 CNRH*2417A** 1.01 0.92 355AAV042060 CNRV*2417A** 1.01 0.92 355AAV042060 CRH*2412A** 1.01 0.92 355AAV042060 CNRH*2417A** 1.01 0.92 355AAV042080 CRH*2412A** 1.01 0.92 355AAV042080 18

DETAILED COOLING CAPACITIE CONTINUED EVAPORATOR AIR CFM 700 800 900 EWB CONDENER ENTERING AIR TEMPERATURE deg F 75 85 95 105 115 Capacity Capacity Capacity Capacity Capacity ystem KW** tem KW** tem KW** tem KW** ys- ys- ys- ens ens ens ens ens NA024---A Outdoor ection With CAR**2414A** Indoor ection ystem KW** 72 27.40 14.58 1.69 26.25 14.15 1.84 25.14 13.73 2.00 24.05 13.33 2.19 22.97 12.94 2.40 67 24.67 17.86 1.69 23.61 17.42 1.83 22.58 16.99 1.99 21.57 16.58 2.16 20.55 16.17 2.36 62 22.42 21.12 1.68 21.48 20.65 1.81 20.57 20.18 1.97 19.70 19.70 2.14 18.95 18.95 2.34 57 22.02 22.02 1.67 21.25 21.25 1.81 20.48 20.48 1.97 19.72 19.72 2.14 18.95 18.95 2.34 72 27.92 15.34 1.73 26.72 14.90 1.88 25.56 14.48 2.04 24.44 14.07 2.23 23.32 13.67 2.44 67 25.17 19.08 1.72 24.07 18.63 1.87 23.00 18.19 2.03 21.96 17.77 2.21 20.92 17.36 2.41 62 23.07 22.70 1.72 22.16 22.16 1.86 21.36 21.36 2.01 20.55 20.55 2.19 19.74 19.74 2.39 57 23.00 23.00 1.72 22.18 22.18 1.86 21.36 21.36 2.01 20.56 20.56 2.19 19.75 19.75 2.39 72 28.30 16.06 1.77 27.06 15.61 1.92 25.87 15.19 2.08 24.71 14.78 2.27 23.57 14.37 2.48 67 25.55 20.23 1.76 24.42 19.78 1.90 23.32 19.34 2.07 22.26 18.91 2.25 21.20 18.48 2.45 62 23.81 23.81 1.76 22.94 22.94 1.90 22.09 22.09 2.06 21.24 21.24 2.24 20.40 20.40 2.44 57 23.81 23.81 1.76 22.94 22.94 1.90 22.09 22.09 2.06 21.25 21.25 2.24 20.40 20.40 2.44 Cooling Indoor Model Capacity Power Furnace Model *CAR**2414A** 1.00 1.00 CAR**2417A** 1.00 1.00 CAR**3014A** 1.01 1.01 CAR**3017A** 1.01 1.01 CNRF*2418A** 1.00 1.00 CNRH*2417A** 1.00 1.00 CNRH*3017A** 1.01 1.01 CNRV*2414A** 1.00 1.00 CNRV*2417A** 1.00 1.00 CNRV*3014A** 1.01 1.01 CNRV*3017A** 1.01 1.01 CRH*2412A** 1.00 1.00 CRH*3012A** 1.01 1.01 FA4CN(F,C)024 0.99 0.99 FA4CN(F,C)030 1.01 1.01 FC4DNF024 1.01 0.96 FC4DNF030 1.02 0.97 FF1ENE024 0.98 0.98 FF1ENE030 1.04 1.04 FK4DNF001 1.00 0.96 FK4DNF002 1.02 0.96 FK4DNF003 1.01 0.95 CAR**2414A** 0.99 0.95 315(A,J)AV036070 CAR**3014A** 0.99 0.95 315(A,J)AV036070 CNRH*2417A** 0.99 0.95 315(A,J)AV036070 CNRH*3017A** 1.00 0.96 315(A,J)AV036070 CNRV*2414A** 0.99 0.95 315(A,J)AV036070 CNRV*3014A** 0.99 0.95 315(A,J)AV036070 CRH*2412A** 1.00 0.96 315(A,J)AV036070 CRH*3012A** 1.00 0.96 315(A,J)AV036070 CAR**2417A** 0.99 0.95 315(A,J)AV048090 CAR**3017A** 1.00 0.94 315(A,J)AV048090 CNRH*2417A** 0.99 0.95 315(A,J)AV048090 CNRH*3017A** 1.00 0.94 315(A,J)AV048090 CNRV*2417A** 0.99 0.95 315(A,J)AV048090 CNRV*3017A** 1.00 0.94 315(A,J)AV048090 CRH*2412A** 1.00 0.94 315(A,J)AV048090 CRH*3012A** 1.01 0.95 315(A,J)AV048090 CNRH*2417A** 0.99 0.95 315(A,J)AV060110 ee notes on pg. 24 Cooling Indoor Model Capacity Power Furnace Model CNRH*3017A** 1.00 0.94 315(A,J)AV060110 CRH*2412A** 1.00 0.96 315(A,J)AV060110 CRH*3012A** 1.01 0.96 315(A,J)AV060110 CNRH*2417A** 0.99 0.95 315(A,J)AV066135 CNRH*3017A** 1.00 0.94 315(A,J)AV066135 CRH*2412A** 1.00 0.96 315(A,J)AV066135 CRH*3012A** 1.01 0.95 315(A,J)AV066135 CNRH*2417A** 1.00 0.96 315(A,J)AV066155 CNRH*3017A** 1.00 0.94 315(A,J)AV066155 CRH*2412A** 1.00 0.96 315(A,J)AV066155 CRH*3012A** 1.01 0.95 315(A,J)AV066155 CNRH*2417A** 0.99 0.95 355AAV042040 CNRH*3017A** 1.00 0.96 355AAV042040 CRH*2412A** 1.00 0.96 355AAV042040 CRH*3012A** 1.01 0.96 355AAV042040 CAR**2417A** 0.99 0.95 355AAV042060 CAR**3017A** 1.00 0.96 355AAV042060 CNRH*2417A** 0.99 0.95 355AAV042060 CNRH*3017A** 1.00 0.96 355AAV042060 CNRV*2417A** 0.99 0.95 355AAV042060 CNRV*3017A** 1.00 0.96 355AAV042060 CRH*2412A** 1.00 0.96 355AAV042060 CRH*3012A** 1.00 0.96 355AAV042060 CNRH*2417A** 0.99 0.95 355AAV042080 CNRH*3017A** 1.00 0.96 355AAV042080 CRH*2412A** 1.00 0.96 355AAV042080 CRH*3012A** 1.01 0.96 355AAV042080 CNRH*2417A** 0.99 0.95 355AAV060080 CNRH*3017A** 1.00 0.96 355AAV060080 CRH*2412A** 1.00 0.96 355AAV060080 CRH*3012A** 1.01 0.96 355AAV060080 CNRH*2417A** 1.00 0.96 355AAV060100 CNRH*3017A** 1.00 0.96 355AAV060100 CRH*2412A** 1.00 0.96 355AAV060100 CRH*3012A** 1.01 0.96 355AAV060100 CNRH*2417A** 0.99 0.95 355AAV060120 CNRH*3017A** 1.00 0.96 355AAV060120 CRH*2412A** 1.00 0.96 355AAV060120 CRH*3012A** 1.00 0.96 355AAV060120 19

DETAILED COOLING CAPACITIE CONTINUED EVAPORA- TOR AIR CFM 875 1000 1125 EWB CONDENER ENTERING AIR TEMPERATURE deg F 75 85 95 105 115 125 Capacity Capacity Capacity Capacity Capacity Capacity ystetetetetem ys- ys- ys- ys- ens KW** ens KW** ens KW** ens KW** ens KW** ens NA030---A Outdoor ection With *CAR**3014A** Indoor ection 72 32.80 17.75 2.08 31.60 17.30 2.28 30.36 16.84 2.50 29.08 16.37 2.75 27.74 15.88 3.03 26.34 15.38 3.33 67 29.84 22.02 2.06 28.75 21.57 2.26 27.61 21.10 2.49 26.44 20.63 2.74 25.22 20.13 3.01 23.95 19.62 3.31 62 27.47 26.23 2.05 26.51 25.74 2.25 25.53 25.20 2.48 24.57 24.57 2.73 23.64 23.64 3.00 22.66 22.66 3.30 57 27.15 27.15 2.05 26.33 26.33 2.25 25.47 25.47 2.48 24.58 24.58 2.73 23.64 23.64 3.00 22.66 22.66 3.30 72 33.28 18.64 2.13 32.03 18.18 2.33 30.74 17.72 2.55 29.41 17.24 2.80 28.03 16.75 3.08 26.59 16.24 3.38 67 30.31 23.47 2.11 29.17 23.01 2.31 28.00 22.53 2.54 26.79 22.05 2.79 25.54 21.54 3.06 24.24 21.02 3.36 62 28.19 28.02 2.10 27.30 27.30 2.30 26.38 26.38 2.53 25.44 25.44 2.78 24.44 24.44 3.05 23.39 23.39 3.35 57 28.18 28.18 2.10 27.30 27.30 2.30 26.39 26.39 2.53 25.44 25.44 2.78 24.44 24.44 3.05 23.39 23.39 3.35 72 33.62 19.48 2.18 32.33 19.02 2.38 31.00 18.54 2.60 29.64 18.06 2.85 28.22 17.56 3.13 26.74 17.05 3.43 67 30.66 24.84 2.16 29.49 24.37 2.36 28.29 23.88 2.59 27.06 23.38 2.84 25.78 22.86 3.11 24.46 22.31 3.41 62 29.01 29.01 2.16 28.09 28.09 2.36 27.13 27.13 2.58 26.13 26.13 2.83 25.08 25.08 3.11 23.98 23.98 3.41 57 29.02 29.02 2.16 28.09 28.09 2.36 27.13 27.13 2.58 26.13 26.13 2.83 25.08 25.08 3.11 23.98 23.98 3.41 ystem KW** Cooling Indoor Model Capacity Power Furnace Model *CAR**3014A** 1.00 1.00 CAR**3017A** 1.00 1.00 CAR**3614A** 1.01 1.01 CAR**3617A** 1.01 1.01 CAR**3621A** 1.01 1.01 CNRF*3618A** 1.01 1.01 CNRH*3017A** 1.00 1.00 CNRH*3617A** 1.01 1.01 CNRV*3014A** 1.00 1.00 CNRV*3017A** 1.00 1.00 CNRV*3617A** 1.01 1.01 CNRV*3621A** 1.01 1.01 CRH*3012A** 1.01 1.01 CRH*3612A** 1.01 1.01 FA4CN(F,C)030 1.00 1.00 FA4CN(F,C)036 1.01 1.01 FC4DN(F,B)036 1.02 0.98 FC4DNF030 1.01 0.97 FF1ENE030 1.00 1.00 FF1ENE036 1.01 1.01 FK4DNF001 1.00 0.96 FK4DNF002 1.01 0.95 FK4DNF003 1.01 0.95 FK4DNF005 1.04 0.96 CAR**3014A** 1.00 0.96 315(A,J)AV036070 CAR**3614A** 1.00 0.96 315(A,J)AV036070 CNRH*3017A** 1.00 0.96 315(A,J)AV036070 CNRH*3617A** 1.00 0.96 315(A,J)AV036070 CNRV*3014A** 1.00 0.96 315(A,J)AV036070 CRH*3012A** 1.00 0.96 315(A,J)AV036070 CRH*3612A** 1.01 0.95 315(A,J)AV036070 CAR**3017A** 1.00 0.96 315(A,J)AV048090 CAR**3617A** 1.01 0.95 315(A,J)AV048090 CNRH*3017A** 1.00 0.96 315(A,J)AV048090 CNRH*3617A** 1.00 0.96 315(A,J)AV048090 CNRV*3017A** 1.00 0.96 315(A,J)AV048090 CNRV*3617A** 1.00 0.96 315(A,J)AV048090 CRH*3012A** 1.00 0.96 315(A,J)AV048090 CRH*3612A** 1.01 0.95 315(A,J)AV048090 CAR**3621A** 1.01 0.95 315(A,J)AV060110 CNRH*3017A** 1.00 0.96 315(A,J)AV060110 CNRH*3617A** 1.01 0.96 315(A,J)AV060110 CNRV*3621A** 1.01 0.96 315(A,J)AV060110 CRH*3012A** 1.00 0.96 315(A,J)AV060110 CRH*3612A** 1.01 0.95 315(A,J)AV060110 CNRH*3017A** 1.01 0.96 315(A,J)AV066135 CNRH*3617A** 1.01 0.96 315(A,J)AV066135 CRH*3012A** 1.00 0.96 315(A,J)AV066135 CRH*3612A** 1.01 0.95 315(A,J)AV066135 CNRH*3017A** 1.01 0.95 315(A,J)AV066155 CNRH*3617A** 1.01 0.95 315(A,J)AV066155 CRH*3012A** 1.00 0.94 315(A,J)AV066155 CRH*3612A** 1.01 0.95 315(A,J)AV066155 ee notes on pg. 24 Cooling Indoor Model Capacity Power Furnace Model CNRH*3017A** 1.00 0.96 355AAV042040 CNRH*3617A** 1.00 0.96 355AAV042040 CRH*3012A** 1.00 0.96 355AAV042040 CRH*3612A** 1.01 0.95 355AAV042040 CAR**3017A** 1.00 0.96 355AAV042060 CAR**3617A** 1.00 0.96 355AAV042060 CNRH*3017A** 1.00 0.96 355AAV042060 CNRH*3617A** 1.00 0.96 355AAV042060 CNRV*3017A** 1.00 0.96 355AAV042060 CNRV*3617A** 1.00 0.96 355AAV042060 CRH*3012A** 1.00 0.96 355AAV042060 CRH*3612A** 1.01 0.95 355AAV042060 CAR**3621A** 1.01 0.96 355AAV042080 CNRH*3017A** 1.00 0.96 355AAV042080 CNRH*3617A** 1.00 0.96 355AAV042080 CNRV*3621A** 1.00 0.96 355AAV042080 CRH*3012A** 1.00 0.96 355AAV042080 CRH*3612A** 1.01 0.95 355AAV042080 CAR**3621A** 1.01 0.96 355AAV060080 CNRH*3017A** 1.00 0.96 355AAV060080 CNRH*3617A** 1.00 0.96 355AAV060080 CNRV*3621A** 1.00 0.96 355AAV060080 CRH*3012A** 1.00 0.96 355AAV060080 CRH*3612A** 1.01 0.95 355AAV060080 CAR**3621A** 1.01 0.95 355AAV060100 CNRH*3017A** 1.00 0.96 355AAV060100 CNRH*3617A** 1.00 0.96 355AAV060100 CNRV*3621A** 1.00 0.96 355AAV060100 CRH*3012A** 1.00 0.96 355AAV060100 CRH*3612A** 1.01 0.95 355AAV060100 CNRH*3017A** 1.00 0.96 355AAV060120 CNRH*3617A** 1.00 0.96 355AAV060120 CRH*3012A** 1.00 0.96 355AAV060120 CRH*3612A** 1.01 0.95 355AAV060120 20