Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Similar documents
Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

RL with INNOVATOR II No Heat Doors

RM with INNOVATOR Doors

Engineering Plan Views

RLNIE with INNOVATOR II

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

RMN with INNOVATOR Doors Technical Data Sheet

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

RLT with INNOVATOR Doors

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

PWEE Technical Data Sheet

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FG-L Technical Data Sheet

P/N _F NSF Certified June 2010

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

LifeLine Premier RLNIE

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Nosing Heater. Return Grill Heater

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RL with INNOVATOR Doors

LWU Technical Data Sheet

RFLNS, RFMNS & RFLTM Freedom Line

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

MD Medium Temperature Self Contained Open Vertical Merchandisers

RFLN & RFMN Freedom Line

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

MD Medium Temperature Self Contained Open Vertical Merchandisers

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

Self-Contained MERCHANDISERS. February

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Reach-in Merchandisers

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

Installation & Service Manual

SERIES NAV S Display Merchandisers

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

Medium Temperature Bulk Produce and Bakery Merchandisers

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

Self-Contained MERCHANDISERS. October

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

BCH Medium Temperature Merchandisers

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Installation & Service Manual

Installation & Service Manual

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

Installation & Service Manual

F-6 Multi-deck Frozen Food Wall Merchandisers

EcoVision Door Manual

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

SERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Service Merchandisers

LTH Low Temperature Merchandisers

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

CU0415, CU0715 and CU0920 Service Parts

Ultra Low Front Rear Load Medium Temperature

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

Transcription:

with INNOVATOR Doors Freedom Line merchandisers are top mount refrigeration ready K E I P/N 0541253_J NSF Certified January 201 F L Warning: Terminal block NOT for case-to-case wire connection! J G I A B We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # (Qty) Description Wiring Item # Fan Assemblies, and Thermostats A. 13W Standard Energy Efficient Fan Assembly (1) 0527610 Fan Motor, Evaporator 046105 Fan Blade Relays B. 0440423 Defrost Limit Thermostat (2) Heaters C. Electric Defrost Heaters (20V) (3) 301531 (1) 3 Door Models 301532 (1) 4 Door Models 301533 (1) 5 Door Models D. Electric Drain Pan Heaters (120V) (4) 050200 (1) 3 Door Models 050201 (1) 4 Door Models 050202 (1) 5 Door Models Item Part # Description Wiring Item # Control Panel E. 300725 Dixell XR75 Control (5) F. 033402 Dixell Discharge Air Sensor (6) G. 033402 Dixell Defrost Sensor (7) Refrigeration H. 0551016 Condensate Pump () 055101 Condensate Float Switch I. 053255 Condensate Pan with Heater (9) J. 0460992 TEV 3 Door Models 0460993 TEV 4 and 5 Door Models LED Fixtures and Power Supply K. 0499399 Power Supply (10) L. Door Lamp, LED BU.444077 Center (11) BU.44407 End (12) Refer to Innovator Reach-In Glass Door Installation and Service manual, P/N 042563, Innovator I and frame replacement parts. Note: Revision J: Updated controller information. Other changes marked with a bar, circle or underline. Data sheet- 20 HUSSMANN CORPORATION BRIDGETON, MO 63044-243 U.S.A. U.S. & CANADA 1-00-922-1919 MEXICO 1-00-90-2900 WWW.HUSSMANN.COM Spanish P/N 0541254

Engineering Plan Views Reach-In 3, 4 & 5 Door Freedom Line Standard Narrow Footprint Plan View 3, 4 & 5 Door 9 (229) Approximate location of Field Wiring 1 in. external whip 4 in. (102 mm) Minimum Air Gap from Merchandiser Insulated Panel to Wall or Flat Surface Maintain air circulation to reduce condensation. Freedom Line RFLNS - RFMNS Plan View A C PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 Merchandiser Liquid Line (in.) 3 / Merchandiser Suction Line (in.) 5 / Dimensions shown as inches and (mm). E 7 () Skid/ External Base Waste Outlet 4 (1219) 6 (152) Bottom Front Support 30 5 / (77) *35 5 / (95) 64 1 /4 (1632) Electrical Wireway Splashguard *37 1 / (943) Relay & Terminal Block Location 26 1 /2 (673) Water Seal (see note **) Front 5-Door Shown *35 5 / Not including door handles to fit through doorway *37 1 / Total width including door handles and bumper **Door Swing Clearance Plan View Dimensions for Freedom Line Options 2 Dr 3 Dr 4 Dr 5 Dr General (A) Merchandiser Length 62 (1575) 92 1 /2 (2350) 122 7 / (3121) 153 3 / (396) Maximum O/S dimension of merchandiser back to front * 37 1 / (943) 37 1 / (943) 37 1 / (943) 37 1 / (943) ** Add 26 1 /2 in. (673 mm) for door swing. Back of merchandiser to rear of splashguard 32 7 / (35) 32 7 / (35) 32 7 / (35) 32 7 / (35) Width of Skid rail 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) Electrical Service (dimensions are approximate) (B) LH end of merchandiser to field wiring connection 9 (229) 9 (229) 9 (229) 9 (229) NOTE: Electrical Field Wiring Connection Point is at top of merchandiser. Waste Outlet (C) Right end of merchandiser to center of waste outlet 23 7 / (606) 54 1 /4 (137) 46 1 /4 (15) 76 5 / (1946) Water Seal Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 PVC drip pipe 1 (25) 1 (25) 1 (25) 1 (25) NOTE: Field installed condensate removal system shipped with merchandiser. Refrigeration Outlet (D) RH end of merchandiser to center of refrigeration interface 5 3 / (136) 5 3 / (136) 5 3 / (136) 5 3 / (136) NOTE: Refrigeration interface is at top of merchandiser. Outside bottom front supports from end of merchandiser 7 () 7 () 7 () 7 () Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610) Distance between Center and Outside supports will vary 2 of 7 U.S. & Canada 1-00-922-1919 Mexico 1-00-90-2900 with Innovator Doors

Freedom Line Narrow, Short Footprint Reach-in Top-Mount-Refrigeration Ready 3, 4 and 5 Door Models Standard Reach-in configuration consists of Innovator I doors, energy efficient fan motors, and EcoShine II LED vertical lighting. 9 3 /4 (250) Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE 20 energy efficiency standards. Provide adequate clearance for air circulation at rear to reduce condensation. Note: An optional Louvered Facade Panel kit is available that will allow for the top spacing minimum clearance of 3 inches (76 mm). 65 1 /2 (1664) DOOR Ceiling 9 1 /4 (235) Minimum 37 1 /4 (946) 29 5 / (752) 21 1 /2 (546) 61 (1549) Dimensions shown as inches and (mm). Note: Facade is field-installed for easy passage through door way. Door handles can be removed to fit through 36 in. wide opening. 4 In. (102 mm) Required Air Gap 79 5 / (2022) Note: Low Height for 0 in. store entrance access REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 F and 55% R.H. FF IC AHRI Rating* Discharge Air ( F) 3 12 3 Evaporator ( F) 9 9 Unit Sizing ( F) 12 20 12 * With door A/S controller Btu/hr/Door Innovator Parallel 1020 100 900 Conventional 1040 1100 930 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. DEFROST DATA FF IC Frequency (hr) 24 24 Defrost Water (lb/dr/day) 1.2 1.2 (± 15% based on merchandiser configuration and product loading.) Electric FF IC Temp Term ( F) 4 4 Failsafe (minutes) 45 45 Gas Not Available 67 (02) FRAME 25 (635) COILS FANS Offtime Not Recommended CONVENTIONAL CONTROLS Cut In Cut Out HPC (psig) 320 395 LPC (psig) 15 5 (366) 5 1 / (130) 3 1 /2 (130) 2 5 / (727) 33 3 / (46) 36 (914) 16 1 /4 (413) 5 1 /4 (133) NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. Working charge with recommended Condensing Unit installed: 2Dr 5.1 lb 1.6 oz 2.3 kg 3Dr 5.6 lb 90 oz 2.5 kg 4Dr 6.7 lb 107 oz 3.0 kg 5Dr 7.0 lb 112 oz 3.2 kg P/N 0531253_J HUSSMANN CORPORATION BRIDGETON, MO 63044-243 U.S.A. WWW.HUSSMANN.COM 3 of 7

Hussmann recommends against frame heater cycling with Innovator doors to prevent door seals from freezing to the frames and tearing. Electrical Data 2Dr 3Dr 4Dr 5Dr Number of Fans 13W 2 3 4 5 Amperes Watts Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Evaporator Fan 120V / 60Hz Standard Energy Efficiency 0.76 1.14 1.52 1.9 50 75 100 125 Door Anti-sweat Heaters (on fan circuit) 120V / 50/50Hz Standard Innovator I 1.5 2.3 3.0 3. 12 273 364 455 120V / 50/60Hz Innovator III 0.9 1.3 1.7 2.2 104 156 20 260 Frame Anti-sweat Heaters (on fan circuit) 120V 50/50Hz Standard 0.7 1.1 1.57 1.97 94 141 1 236 Condensate Pan Heater 120V 5.0 5.0 5.0 5.0 600 600 600 600 Condensate Pump 120V 0.19 0.19 0.19 0.19.7.7.7.7 Defrost 20V 1Ø Electric Defrost 6.72 10.0 13.46 16.2 1400 2100 200 3500 120V Drain Pan Heater 0.63 1.25 2.00 2.50 75 150 240 300 Standard Vertical LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Hussmann EcoShine II - A (120V) 0.31 0.46 0.62 0.77 37.1 55.6 74.2 92.7 Case electrical data only shown for reference. For total electrical circuit requirements (MCA and MOPD) refer to condensing unit data sheet, part number 05474. Notes: 1. Electrical input requirements: The RFLNS Freedom case requires one 20/230V 60Hz single phase 4-wire connection. 2. External whip provided for 20 / 230 Volt 4-wire 60Hz connection. A qualified electrician should perform all wiring in accordance with the NEC code and/ or all local codes. Wire sizing must take into account the total distance from the electrical panel to the Freedom case. 4 of 7 U.S. & Canada 1-00-922-1919 Mexico 1-00-90-2900 with Innovator Doors

Product Data Recommended Usable Cube 1 (Cu Ft/Dr) AHRI Total Display Area 2 (Sq Ft/Dr) Shelf Area 3 (Sq Ft/Dr) 20.95 ft 3 /Dr (0.59 m 3 /Dr) 12.66 ft 2 /Dr (1.1 m 2 /Dr) 27.20 ft 2 /Dr (2.53 m 2 /Dr) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 1200 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 21-inch deep shelves. ESTIMATED SHIPPING WEIGHT 4 Freedom Line Merchandiser (20-Inch Facade) 2 Dr 3 Dr 4 Dr 5 Dr Solid End (each) lb (kg) 105 (492) 1357 (616) 12 (29) 2230 (1012) 74 (34) 4 Actual weights will vary according to optional kits included. P/N 0531253_J HUSSMANN CORPORATION BRIDGETON, MO 63044-243 U.S.A. WWW.HUSSMANN.COM 5 of 7

P CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = P = Purple 2P = Purple (2 Bands) DB = Dark BK = BL = BR = Brown Y = Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY). 20A FUSE D/A TEMPERATURE SENSOR DEFROST TERMINATE SENSOR 7 6 5 24 23 22 21 20 19 1 16 XR75CX G 7 6 5 4 3 2 1 BROWN 2 BROWN BLUE 3 DEFROST HEATERS 20 V COMPRESSOR RELAY DEFROST RELAY 20A FUSE DPST SWITCH 26 23 22 21 20 16 15 14 13 12 11 10 9 9 CONDENSATE PAN HEATER FANS GFCI OUTLET 1 FIELD INSTALLED CONDENSING UNIT L N H H P 2P CONDENSATE PUMP GREEN DASH CONTROLLER GROUND L1 L2 N DOOR A.S. HEATERS 120 V FRAME A.S. HEATERS 120 V LIGHTS 120 V 2P 20 V 1 PHASE 60 HZ INPUT HUMIDITY SENSOR ORANGE ORANGE LIGHT SWITCH 0539476_G HEATER LIMIT SWITCH 2 L1 L2 CONNECT TO LEADS PROVIDED ON TOP OF CASE DRAIN PAN HEATER 4 Dixell Wiring Diagram Reach-in Electric Defrost Sequence - 1. Power from the defrost relay energizes Defrost Heaters. The Dixell control opens the fan circuit and energizes the drain pan heater. 2. Temperature rise of the evaporator closes the Relay Control Thermostat (3) at about 35 F, energizing 120V A.S. Relay Coil (4). This relay s contacts open the Frame and Door Heater Circuits. 3. When Defrost Termination Sensor reaches the termination temp, the defrost relay opens the Defrost Heater Circuit. The Dixell control turns off the drain pan heater and turns on the fans. 4. Temperature fall of the evaporator opens the Relay Control Thermostat (3) at about 20 F, de-energizing 120V A.S. Relay Coil (4). A.S. Relay Contacts close the Frame and Door Heater Circuits. 6 of 7 U.S. & Canada 1-00-922-1919 Mexico 1-00-90-2900 with Innovator Doors

Standard Vertical Lighting Hussmann EcoShine LED Fixtures Light Switch 16 16 Wireway 15 Terminal Block 20 3 Door LED Light Wiring Diagram Light Switch 16 16 16 Terminal Block 15 20 Wireway 4 Door LED Light Wiring Diagram Light Switch 16 16 16 16 Wireway 15 15 Terminal Block 20 5 Door LED Light Wiring Diagram WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled numbers = Parts List Item Numbers R= Y = Yellow G = Green BL = BK = W = = 120V Power = 120V Neutral = Field Ground = Case Ground P/N 0531253_J HUSSMANN CORPORATION BRIDGETON, MO 63044-243 U.S.A. WWW.HUSSMANN.COM 7 of 7