Certificate of Conformity Certificate num. Registration date Version Valid until

Similar documents
PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Certificate of Conformity Certificate num. Registration date Version Valid until

Certificate of Conformity Certificate num. Registration date Version Valid until

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Hospitals and Major Medical Centers

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

FIRE SUPPRESSION SYSTEM

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

BOC FS125 The Fire Extinguishing Solution

Safe, Effective, Environment-friendly

Australian/New Zealand Standard

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

CO2 COCO GAS FLOODING SYSTEM

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

SECTION FM-200 FIRE SUPPRESSION SYSTEM

SPECIFICATION: ARGONITE Engineered Fire Suppression System

TECHNICAL DATA OBSOLETE

Inert Gas Fire Extinguishing System

Data/ Specification Sheet

Fire Protection in the Mining Industry. Garry Kwok Board Member

Engineering Specifications

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

Twin-Agent Fire Fighting/Securing Systems Specifications

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Carbon Dioxide Fire Suppression Systems

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

TECHNICAL DATA. 319a. January 27, 2012

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Design & Construction Standards, Revised January

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

Fire suppression systems for server rooms and data centres

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

An Overview of Extinguishing Systems for Computer Equipment

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

FM-200 In-Cabinet Series

Rick Seidel Fike Corporation Regional Sales Manager

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

ODS & SGG Alternatives for the Fire Protection Industry 2018

READY FOR CHANGE. A Guide for Meeting the NFPA Compliance Standard for Portable Fire Extinguishers

5.07 Air Replenishment Systems

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

TOTALPAC2 Integrated Fire Protection System

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

CERTIFICATION SAFETY & BEYOND

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

MONITRON II MODEL EH-M2 ELECTRIC BOILER OPERATION AND INSTALLATION INSTRUCTIONS. Four stage electronic control with energy saving and other features.

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

CO 2 Fire Extinguishing Systems

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

WORMALD INTERNATIONAL ELECTRIC VALVE ACTUATOR

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

CARBON DIOXIDE CO 2 Industrial fire suppression systems

A Guide for Meeting NFPA 10 Subsection

EL765. Fire Extinguishers [EL /2/ ]

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Committee Input No. 9-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

FIRE PROTECTION PROGRAM

CRU-S Series Stainless Steel Condensate Recovery Unit

Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995

NOTICE INVITING TENDER

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

LaserFOCUS VLF-250 Engineering Specification

D. Reference Standards (Utilize latest editions available):

Public Safety [661] Chapter 226, Liquefied Petroleum Gas, Amended for Application within the State of Iowa

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

CLEAN AGENTS Updates to the NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems 2015 Edition

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

PriceList Category PartNbr Part Description Weight (l MSRP

Types of Detection. Fusible Link Detection - Most Common

Fire fighting Portable fire extinguishers Performance and construction

CO2 High Pressure Extinguishing System

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Capital Projects Group Fire Extinguishers Specification

Transcription:

CSIRO Verification Services Highett, Victoria, Australia +61 (0)3 9252 6000 http://www.activfire.gov.au/ Page 1 of 5 Issued by Product designation Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system (Refer to the Schedule/enclosures for further specified details) Agent/distributor Tyco Fire Protection Products 567 Somerville Road, SUNSHINE, VIC, AUSTRALIA, 3020 Registrant Ansul Incorporated One Stanton Street, MARINETTE, WI, UNITED STATES, 54143-2542 Producer Ansul Incorporated One Stanton Street, MARINETTE, WI, UNITED STATES, 54143-2542 Conformance criteria and evaluation The Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system has been evaluated and verified as conforming with the relevant requirements of the following criteria. 1. Australian Standard AS 4214-2002, 'Gaseous fire extinguishing systems'. 2. SSL Appraisal Specification FAS-102, Version 3.1, 'Gaseous Extinguishing Systems'. Limitations/conditions of conformance Limitations/conditions of conformance, where identified on this certificate, are derived from qualifications from evaluation(s) for conformity and/or other related technical documentation. All details with respect to design, assembly and installation instructions and restrictions should be checked against the producer's current technical manual/data sheets and the requirements of the Authority having Jurisdiction. Specified limitations/conditions, determined from the evaluation for conformity, include the following. i. The components of Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system are designed to operate in the temperature range - 20 C to 50 C. ii. INERGEN storage containers designed to hold INERGEN in gaseous form at a nominal pressure of 300 Bar at 15 C. iii. Enclosure venting shall be provided and designed to ensure that, when the system is discharged, the pressure within the enclosure can not become harmful to the enclosure or its occupants. (Limitations/conditions of conformance continue) This certification is issued within the scope of CSIRO Verification Services Rules governing ActivFire Scheme and is valid only for the product(s) as submitted for evaluation and verification of conformity, subject to the following conditions. Reference to details, limitations and requirements, where documented as a schedule/enclosure with this certificate. The Registrant is responsible for their attestation of conformity and ensuring that on-going production complies with the conformance criteria defined in this certificate. This certificate will not be valid if any changes or modifications are made to the product which have not been notified and validated by CSIRO Verification Services. This certificate is subject to periodical re-validation upon verification that all requirements, as determined by the conformity assessment body, continue to be satisfactorily met by the Registrant. This certificate may only be reproduced in its published form, without modification and inclusive of all schedules/enclosures. Any changes, errors or omissions, must be submitted in writing and if necessary or requested, substantiated with relevant evidence. Any representations, such as advertising or other marketing related activities or articles shall reflect the correct contents of this certificate and conform with all relevant trade practices.and consumer protection legislation and regulations. Any terms or conditions of use as applicable to content and documentation as published or accessed through web sites administered by the CSIRO Verification Services. David Whittaker Executive Officer ActivFire Scheme CSIRO Australia, 2011 This certificate remains the property of CSIRO and may be subject to amendment, suspension or withdrawal at any time. The validity and authenticity of this certificate can be verified by the certification register located at http://www.activfire.gov.au

Page 2 of 5 Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing systems installed in Australia and New Zealand are subject to the following additional requirements: i. Installation and service of Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system shall be carried out by technicians/staff accredited by TYCO Technical Services in the handling of pressurised containers and the system installation and service manuals ii. Design of Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system shall be carried out by staff accredited by TYCO Technical Services using the TYCO Safety Products, INERGEN 300 Bar calculation program. iii. All Inergen refilled cylinders are to be distributed by only accredited Wormald Branches. Inergen filling shall be carried out by a licenced gas filler accredited to ISO 9002. Analysis of each batch of filled cylinders shall be performed by a NATA accredited laboratory using a gas chromatograph for two of the three gases. This NATA analysis tag is attached to every filled Inergen cylinder which specifies the laboratory report number, analysis date, cylinder number, volume of gas in the cylinder and quantity and tolerance of each constituent gas. Producer's description The Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system is an engineered gaseous total-flooding type fire protection system which extinguishes fire by using patented blend of inert gases to dilute the oxygen content of the air within the risk enclosure. The inert gas blend is marketed by TYCO International as INERGEN (IG-541), and is a mixture of nitrogen, argon and carbon dioxide in appropriate percentages. The three gases: Nitrogen, Argon and Carbon Dioxide are mixed in the following proportions: Nitrogen 52% Argon 40% Carbon Dioxide 8% As these gases occur naturally in the atmosphere, accidental and deliberate releases of INERGEN do not contribute to global atmospheric warming or ozone depletion. INERGEN agent complies with the NFPA Standard 2001, Standard for Clean Agent Fire Extinguishing Systems and EPA Program SNAP. The agent is also listed and approved by Underwriters Laboratories, Inc. (USA) and factory Mutual Research Corporation. INERGEN is particular suitable for use in occupiable areas because the recommended extinguishing concentrations result in an atmosphere within the protected enclosure which can be breathed for a prolonged period with no risk to health and little if any discomfort. The INERGEN is stored at 300 Bar, the storage cylinder, discharge valves, other control valves, the manifold piping, being stronger than those of the 200 Bar system and otherwise suitable for the higher agent pressure. INERGEN systems are designed to extinguish fires involving flammable liquids, gases and class A, B & C hazards, especially electrical equipment. Providing a Class A fire is detected quickly, the INERGEN is discharged promptly and the concentration is maintained for an adequate period of time to allow embers to cool, then surface fire and the embers associated with the burning of solid materials are quickly extinguished. Class B & C fires are quickly extinguished by INERGEN at appropriate concentrations, but in the case of Class C fires the risk of explosion should be carefully considered and where possible the flammable gas flow should be isolated before or as soon as possible after extinguishment.

Page 3 of 5 Technical specification The following details are a representative extract of the technical specification for the Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system and may be subject to change. Complete and current details should be determined from the designated producer s technical manual/data sheets. The components of the Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system that have been appraised by form part of the listed system include the following: INERGEN 80 Ltr. Container Filled 300 Bar KO 240 435 6 INERGEN 80 Ltr. Container label KO 235 396 0 Pressure Indicator DKE-6 KO 241 098 7 Pressure Monitoring Device KM-4 KO 241 099 6 Accessories for KM-3 and KM-4 KO 241 092 6 Connection Hose DN12 / 300 Bar KO 247 021 3 Pressure reducer DRE/VS II KS 241-DRE-VS-II Manifold KS 246-ISR Quick Action Valve CI 12-9 KO 241 029 6 Container Top Label 300 Bar KO 235 382 0 Container Neck Label 300 Bar KO 235 386 0 Check Valve RSVI-12 / 300 Bar KO 241 371 6 8 Ltr. Cylinder Filled 200 Bar KO 240 401 6 8 Ltr. Cylinder Label KO 235 398 6 Cylinder Retention Ring KO 240 140 6 8 Ltr. Cylinder Retention Bar KO 240 504 6 27 Ltr. Cylinder Filled 200 Bar KO 240 412 6 27 Ltr. Cylinder Label KO 235 398 6 Cylinder Retention Ring KO 240 140 6 Connection Hose DN10 / 200 Bar KO 247 022 6 Actuation Hose 200 Bar DN 8 KO 247 021 6 Adaptor DN 8 KO 240 305 6 Fixing Link KO 240 080 6 INERGEN 80 Ltr. Container Filled 200 Bar KO 240 415 6 INERGEN 80 Ltr. Container label KO 235 398 6 Pressure Indicator DKE-6 (200 Bar) KO 241 098 6 Pressure Monitoring Device KM-4 KO 241 099 6 Accessories for KM-3 and KM-4 KO 241 092 6 Quick Action Pilot Valve Cl 12-6 KO 241 025 6 Terminal Box KO 246 672 6 Slave Cylinder Branch Tee KO 029 193 6 Hose DN8 KO 247 021 6 Release Head III KO 241 381 6 Manual override KO 240 627 6 Manifold Bracket - Short KO 240 106 6 ½ in. x 180 Nozzle (NPT) 310.208.001 ½ in. x 360 Nozzle (NPT) 310.208.002 ½ in. x 180 Nozzle (BSP) 310.208.007 ½ in. x 360 Nozzle (BSP) 310.208.008 1 in. x 180 Nozzle (NPT) 310.208.003 1 in. x 360 Nozzle (NPT) 310.208.004 1 in. x 180 Nozzle (BSP) 310.208.009 1 in. x 360 Nozzle (BSP) 310.208.010 1 ½ in. x 180 Nozzle (NPT) 310.208.005 1 ½ in. x 360 Nozzle (NPT) 310.208.007 1 ½ in. x 180 Nozzle (BSP) 310.208.011 1 ½ in. x 360 Nozzle (BSP) 310.208.012

Page 4 of 5 ½ in. x 360 Nozzle (VdS/DIN) KS 241 GRD ½ ½ in. x 360 Nozzle (VdS/DIN) KS 241 GRD ½ 1 in. x 360 Nozzle (VdS/DIN) KS 241 GRD 1 Local Application Nozzle - GOD KO 241 GOD Fixture Parts KO 240 109 6 Step Motor Delay Device SMV-1 KO 241 397 6 Programming Interface PSS-1 KO 099 016 0 Electric Actuator SF-2 KO 246 032 6 Pilot Cylinder Tee KO 029 196 6 Lock Off Unit KO 246 289 6 Adaptor 18mm x 1.5 to 10 mm KO 240 305 6 Slave Cylinder Elbow KO 029 191 6 Manifold Bracket Long KO 240 108 6 Retention Bar 560 mm KO 240 102 6 Grate 560 mm KO 368 160 6 Retention Bar 840 mm KO 240 104 6 Grate 840 mm KO 368 165 6 Test and Relief Unit PRE-1 KO 242 466 6 Filter for Pilot Line DN8-SLF2 KO241 386 6 Switch Over, Main / Standby UER-1 KO 240 136 6 Fixture for Pilot Cylinder (27 Ltr.) KO 240 506 6 Straight Coupling RA 12 KO 029 141 6 Straight Coupling RA 10 KO 029 122 6 Adjustable T Coupling KO 029 193 6 Automatic Vent Valve SGV-1 KO 241 233 6 Pilot Gas Release Valve ELV-1 KO 241 231 6 T Coupling for SGV-1 / ELV-1 KO 029 510 6 Pilot Line 10 x 1.5 DIN 2391 KO 403 050 6 Orifice at the Container DRE-V/S KS 241-DRE-VS-300 Release Head III KO 241 381 6 Pneumatic Actuator KO 241 388 6 Local Manual Actuator KO 240 6276 Discharge Pressure Switch - Latching 305.205.006 Discharge Pressure Switch Non-Latching FF4-A22-022 KO 246 299 6 Test Unit for Pressure Switch FF4-A22-022 KO 246 296 6 Pressure Switch - Flameproof 305.205.003 Container Supervisory Pressure Indicator KM-4 KO 241 099 6 Union-joint 50 RL KO 240 311 6 Union-joint 80 RL KO 240 315 6 End cap 50 R KO 240 314 6 End cap 50 L KO 240 318 6 End cap 80 R KO 240 319 6 End cap 80 L KO 240 320 6 Elbow 50 RL KO 240 307 6 Elbow 80 RL KO 240 309 6 Tee 50 RRL KO 240 327 6 Tee 50 x 25 x 50 RRL KO 240 329 6 Tee 80 RRL KO 240 321 6 Tee 80 x 50 x 80 RRL KO 240 323 6 Tee 80 x 25 x 80 RRL KO 240 325 6 Connecting Pipe 560-50 RL KO 240 258 6 Connecting Pipe 560-80 RL KO 240 259 6 Discharge Hose DN12/300 Bar KO 247 021 3 Check Valve 305.208.001

Page 5 of 5 Automatic Venting valve GGV-1 KO 241 233 6 Pressure reducing Unit DRE-3-DN 50 KS 241 DRE3 Retention Plate KO 240 140 6 Retention Bar KO 240 102 6 Fixing Link KO 240 080 6 Free Standing Post KO 240 142 6 Distribution Valve Assembly 308.208.001 Manual bypass Valve 302.001.008 Curtain Trip 305.200.007 Manual Release Caution Plate SL 93936 Door Caution Plate (Lock-off) SL 93481 Door Caution Plate (No Lock-off) SL 93482 Over Pressurisation vent 300 x 300 302.205.014 Over Pressurisation vent 500 x 500 302.205.015 INERGEN, 300 Bar, Engineered, Total Flooding, Fire Extinguishing System, Design, Installation, Commissioning, Servicing and Maintenance Manual, January, 14A-09 2006 Piping requirements: Two types of piping shall be used in the Tyco Safety Products, INERGEN 300 bar, engineered total flooding fire extinguishing system: 1. High pressure piping, extending from the storage cylinders to the pressure reducing orifice. This shall be suitable for a working pressure of at least 23.0 MPa and shall be Class 2 or 3, Pipe Grade B, in accordance with AS 4041. Minimum thickness of pipe wall shall be in accordance with BS 1600 and ANSI/ASME B36.10M. Welding shall be by Certified Code Welders only. Welded flanges shall be to ANSI/ASME B16.5 Class 900 lb, AS 2129 Table T. Butt-welded fittings shall be to ANSI/ASME B16.9 or BS 1640 Classes 1 and 2 (Standard weight = Schedule 40. Extra strong = Schedule 80). Screwed fittings shall be DN50 maximum, and shall be 3000 lb fittings to BS 3799 or ANSI B16.11. 2. Low pressure piping, extending from the pressure reducing orifice to the nozzles. This shall be suitable for a working pressure of at least 11.5 MPa and shall be Class 2 or 3, Pipe Grade B, in accordance with AS 4041. Minimum thickness of pipe wall shall be in accordance with BS 1600 and ANSI/ASME B36.10M. Welding shall be by Certified Code Welders only. Welded flanges shall be to ANSI/ASME B16.5 Class 600 lb, AS 2129 Table K. Butt welded fittings shall be to ANSI/ASME B16.9 or BS 1640 Classes 1 and 2 (Standard weight = Schedule 40; Extra strong = Schedule 80). Screwed fittings shall be DN50 maximum, and shall be 3000 lb fittings to BS 3799 or ANSI B16.11.