HUMIDITY SENSING BATH FAN

Similar documents
VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN / LED LIGHT

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

VENTILATION FAN WITH BLUETOOTH SPEAKER

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

VENTILATION FAN WITH LIGHT AND HEATER

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

breeze easytm model # F100-1W

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Installation Instructions Exhaust Fan With Light

READ AND SAVE THESE INSTRUCTIONS

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Please Read and Save These Instructions Safety Information

INSTALLATION MANUAL AND USER GUIDE

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL AND USER GUIDE

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Easy installation in both new construction and retrofit

INSTALLATION INSTRUCTIONS

Bathroom Exhaust Fan

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Easy installation in both new construction and retrofit

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Heater/Exhaust Fan/Light User s Guide

Bathroom Exhaust Fan/Fluorescent Light Combination

CONTENTS WIRING DIAGRAM

Bathroom Exhaust Fan/Fluorescent Light Combination

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Insulated Ventilators. Operating Instructions & Parts Manual

READ AND SAVE THESE INSTRUCTIONS

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Easy installation. T080LP ENERGY STAR Lo Profile Ventilation Fan INSTALLATION GUIDE

CVS Model Inline Multi-Port Ventilators

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

RP, GP, XP Pro Series Installation Instructions

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

Integrated Ventilation System

FLCH4R Garage and Utility Electric Heater

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

DBF 4XL Dryer Booster Fans

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Please Read and Save These Instructions.

RP / RPc Series Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

SF180 Installation Instructions

Wall Hanging Mode. Pedestal Mode

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

ELECTRIC FLAT PANEL FIREPLACE HEATER

ELECTRIC STOVE HEATER Models: FS2213B

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

READ AND SAVE THESE INSTRUCTIONS

24 & 30 Quiet Design Oscillating Wall Mount Fan

Use and Care & Installation Guide

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

IN014 Rev P Saber Way, Ward Hill, MA radonaway.com

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Self-Cleaning Range Hoods

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

User s Manual WS-5830SS WS-5836SS WS-5842SS

READ AND SAVE THESE INSTRUCTIONS

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

Use, Care, and Installation Guide

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

MaxLite LED Vapor Tight Linear Fixture

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

APPUZO RANGE HOOD INSTALLATION

READ AND SAVE THESE INSTRUCTIONS

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

READ AND SAVE THESE INSTRUCTIONS

Transcription:

HUMIDITY SENSING BATH FAN MODEL VFB070B3H / SLM70H TABLE OF CONTENTS Package Contents General Safety Information 3 Preparation and Wiring Diagrams 4 Assembly Instructions - New Construction 5 Assembly Instructions - Existing Construction 6 Grille Installation 8 Humidity Sensing Fan Operation 8 Care and Maintenance 9 Troubleshooting 0 Dimensions Warranty READ AND SAVE THESE INSTRUCTIONS Address: 460 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: -888-979-9889

PACKAGE CONTENTS

GENERAL SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION. Make sure that the electric service supply voltage is AC 0V, 60Hz.. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act). 3. Always disconnect the power source before working on or near the ventilating fan, motor or junction box. 4. Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects. 5. Do not kink the power cord. 6. shown in Fig.A. 7. Provide suction parts with proper ventilation. 8. This unit is UL Listed for use over a bathtub or shower when installed in a GFCI protected branch circuit. 6. Ducted ventilating fans must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) protected branch circuit. 8. Do not use this unit with any other solid-state control device. Solid-state controls may cause harmonic distortion, which can cause a motor humming noise. 9. NEVER place a switch where it can be reached from a tub or shower. 0. Not to be installed in a ceiling thermally insulated to a value greater than R50. (This is required for installation in Canada only). Turning angle too large Duct shrink WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Too many elbows Turning angle too large Elbow near the body Duct shrink Body. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.. Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent the power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by Too many elbows Fig. A Minimum 8 in. Elbow near the body Body CAUTION. For general ventilating use only. Do not use to exhaust Minimum 8 in. hazardous or explosive materials and vapors.. Not for use in cooking areas. (Fig.B) 3. This product must properly Cooking connect area to the grounding conductor of the supply Do not circuit. install above or inside this area 4. To reduce the risk of injury to persons, install the fan at 4. burning equipment to prevent backdrafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and local code authorities. 5. When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities. 45 45 Cooking area Do not install above or inside this area Cooking Equipment Cooking Equipment Fig. B 45 45 floor floor 3

PREPARATION Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife Helpful Tools (not included): Electric Drill, Drill Bits WARNING: Turn off electricity at breaker box before beginning installation. Carefully remove unit from carton. Check area above installation location to be sure that wiring can run to the planned location and that duct proper ventilation. Inspect duct work and wiring before proceeding with installation. Before installation, provide inspection and future maintenance access at a location that will not interfere with installation work. You may need the help of a second person to install this fan: one person on the attic side and one on the room side. Note: Installations may vary depending on how the previous bath fan was installed. Supplies necessary for the installation of your bath fan are not all included. However, most are available at your local home improvement or hardware store. DIMENSION REQUIREMENTS Housing Dimension (L) WIRING DIAGRAM Housing Dimension (W) Housing Dimension (H) 7 / in. 7 /4 in. 4 in. Fan housing Short piece of flexible duct helps alignment and absorbs sound Seal gap around housing Caulk termination to duct Proper insulation around the fan to minimize building heat loss and gain. 3 circular duct is recommended for installation. The ducting from this fan to the outside of building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow. Locate unit above (GFCI-protected circuit required) or within 5 feet of the shower head. Locate unit away from heating or cooling sources which can affect humidity levels. Do not locate near window. Unit may respond to the outdoor humidity level. Unit must be installed in ceiling to properly sense moisture. proper sensing. The fan will operate most efficiently when located where the shortest possible duct run and minimum number of elbows will be needed. Use a roof cap or wall cap that has a built-in damper to reduce backdrafts. or Roof cap (with built-in damper) Wall cap (with built-in damper) JUNCTION BOX BLACK WHITE SWITCH BOX OFF ON POWER SWITCH L N BLACK WHITE GROUND ON/OFF SWITCH (purchase separately) SWITCH BOX (bare) GREEN GRD Note: Do not use with timer switch. POWER SWITCH 0 VAC LINE IN WIRING PLATE 4

ASSEMBLY INSTRUCTIONS NEW CONSTRUCTION BEFORE INSTALLATION Turn off power source. Review all safety precautions.. Attach the Duct Connector to the Fan Body.. Remove the wiring box cover from the Fan Body. Remove the wiring knockout from the wiring box cover with a flathead screwdriver (not included). 3. Place the Fan Body next to a ceiling joist or wall stud. The Fan Body should be level and perpendicular to the joust or stud 3 Joist or wall stud 4. Mount the Fan Body to the joist or stud using 4 nails (not included) were indicated. Joist or wall stud Nail Nail 5

ASSEMBLY INSTRUCTIONS 5. Pull the wire through the hole and into the junction box(not included), secure 0VAC house wiring from the wall diagram on page4. 4AWG is the smallest conductor that shall be used for branch-circuit wiring. Push the wires back through the hole. Reattach the wiring box cover. 5 6. Install a circular 3 in. duct (not included) and secure it with duct tape or clamps (neither included). 6 6 3 in. Duct Finish ceiling work. The ceiling hole should be aligned with the edge of the fan housing. Duct tape or clamp Ceiling EXISTING CONSTRUCTION BEFORE INSTALLATION Turn off power source. Review all safety precautions.. Remove existing fan.. Measure the opening to ensure it is large enough to accommodate the new Fan Body(7 /in. x 7 /4in.). Note: 7 /4 inch side of opening should be flush with the joist. 6

ASSEMBLY INSTRUCTIONS 3 3. If this fan is not replacing an old fan, be sure to cut a 7 /in. x 7 /4in. opening for the Fan Body ❶. Make sure the 7 /4 inch side of opening is flush with the joist for installation from below. in. 7 / " 9.4.4" 9/4 7 in. 4 4. Attach the Duct Connector to the Fan body. Remove the wiring box cover from the Fan Body ❶. Remove the wiring knockout from the wiring box cover with a flathead screwdriver (not included). Remove the three screws that hold the fan motor assembly in place. Remove the fan motor assembly from the Fan Body ❶. Unplug fan connector. ❶ 5 5. Pull the wire through the hole and into the junction box(not included), secure 0VAC house wiring from the wall diagram on page4. 4AWG is the smallest conductor that shall be used for branch-circuit wiring. ❶ Push the wires back through the hole. Reattach the wiring box cover. 6 6. Install a circular 3 in. duct (not included) and secure it with duct tape or clamps (neither included). tud r wall s Joist o 3 inch duct ❶ Mount the Fan Body ❶ to the joist or stud using nails (not included) were indicated. Tape Nail 7. Plug the fan connector and fan assembly back into the Fan Body ❶. Reattach the fan assembly using the three screws removed in step 4. 7 7

GRILLE INSTALLATION. Pinch the mounting springs on the Grille, and insert them into the narrow rectangular slots inside the fan. Push the Grille up toward the ceiling. Turn on electricity at the breaker box after finishing installation. HUMIDITY SENSING FAN OPERATION. Humidity Sensing Mode: Flip wall switch to ON position. The LED indicator light in the fan will be BLUE. The fan will automatically start when the humidity level in the room is above 60%. If humidity level is below 60%, the fan will stop automatically. Blue LED Light. Full Speed Mode: Cycle wall on/off switch. LED indicator light in fan will be AMBER. 3 Amber LED Light 3. Fan Off: Move wall on/off switch to OFF position. 8

CARE AND MAINTENANCE See safety information before proceeding. Routine maintenance should be done at least once a year. Never use solvents, thinner or harsh chemicals when cleaning the fan. Do not allow water to enter the motor. Do not immerse metal parts in water. Do not immerse resin parts in water over 40º Fahrenheit. Turn off power source. Review all safety precautions.. To remove grille ❷, squeeze springs and pull down.. Wash and clean the grille ❷ in a sink and dry with a cloth. 3. Remove dust and dirt from the fan body ❶ with a vacuum cleaner. 3 4. Dampen cloth with dust detergent and wipe the fan body ❶. Then wipe dry with a clean cloth. Vacuum cleaner 4 5 5. Replace grille ❷ back onto fan body ❶. 6. Turn on power source to operate fan again. 9

TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION The fan is not turning on. Power off. Faulty switch 3. Faulty wire connection. Make sure power supply is on.. Test or replace switch. 3. Check wire in switch box. The fan seems louder than it should. CFM too great. Damper not working properly or damaged 3. Bend in duct too close to fan discharge 4. Fan discharge duct 5. Fan body not securely attached. Be sure the CFM rating on the fan matches the size of your room.. Check damper to ensure it is opening and closing properly. If the damper has become damaged, please call Customer Service. 3. Be sure you do not have any sharp bends in duct closer than 8 in. to the fan discharge. 4. Use recommended size ducting to reduce fan noise. 5. Be sure the fan is securely attached to your ceiling joists. The fan is not clearing the room. airfow within room. Be sure a door or window is slightly ajar or opened.. Be sure the CFM rating on the fan matches the requirements for your room size. The fan keeps running even though the house humidity level is lower than 60% RH. Our sensor tolerance is +/-0% RH. Outdoor humidity is back drafting to the fan. Continue to let the fan run since it is good to keep venting the house and the electric bill is minimal (approximately less than $0 per year).. Turn the fan off when not in use. 0

DIMENSIONS 3 9 3/8 0 3/4 3/6 4 UNIT: INCH PRODUCT SPECIFICATIONS SPECIFICATIONS Model No. Voltage (V) Frequency (Hz) Fan Power @ 0. SP (W) Air Flow @ 0. SP (CFM) Weight (lb.) Max. Current (amps) VFB070B3H SLM70H 0 60 70 3.65 0.9 Note: Design and specifications subject to change without notice.

WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc. ( Delta Electronics ) warrants to the original consumer purchaser in the USA and Canada that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase. Limitations and Exclusions. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer. The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and installation service.. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta Electronics F.O.B. shipping point. 3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict product liability or otherwise. 4. 5. The warranty does not cover if user does not comply with manufacturer s installation manual. 6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below. 7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect, improper transportation or storage, improper testing, improper installation, improper operation, accident of products or parts thereof, or unusual deterioration or degradation of products or parts thereof due to Address: 460 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: -888-979-9889 www.deltabreez.com Model:VFB070B3H / SLM70H