Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Similar documents
Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Domestic Chill Tap

Zip Domestic ChillTap

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip HydroTap Miniboil

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Miniboil Boiling Only

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Zip Autoboil Installation and Operating Instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Zenith ChillTap Sparkling

Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

HydroTap Taps Installation

Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

Zip Autoboil. Installation and Operating Instructions

Installation Instructions. Filtered Boiling and Boiling Ambient drinking water for commercial kitchens and tea rooms.

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Installation Instructions Zip HydroTap G4 CS Residential Affix Model Number Label Here

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Zip Chilled Water Systems

Affix Model Number Label Here 89944

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Zip HydroTap. B & BA Residential. Affix Model Number Label Here Installation Instructions

Installation & Operating Instructions

Zip HydroTap G4 Celsius

Installation Instructions Zip HydroTap G4 BCS Residential Affix Model Number Label Here

ZIP HydroTap G4 Celsius User Guide

Installation, Operating and Maintenance Guide

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Zip Chillmaster Floor Mounted Chiller

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Unvented Electric Water Heater 10/15 litre Undersink

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

Own. Thermostatic Mixing Valve. Owner s Manual Containing. Installation, Commissioning and Maintenance guides. Lic. WMKA1895 AS SAI-Global.

MODULAR AUTOMATIC GRANULAR ICE FLAKER

INSTANTANEOUS ELECTRIC SHOWER

Zenith HydroTap. Filtered Chilled drinking water for residential kitchens and tea rooms. Affix Model Number Label Here NZ

Installation, Operating and Servicing Instructions

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

AUTOMATIC MODULAR ICE-CUBE MAKER

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Model pictured: ST6001

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS

DOMETIC PTY. LTD. Camping Boxes-Refrigerator. Models: RC 1600 EGP Type: JCB - 1. Operating Instructions AUS

HW3 Handwash Installation and Operating Instructions

Zenith HydroTap. CS Residential. Filtered Boiling, Chilled and Sparkling drinking water for Residential kitchens and tea rooms.

Hot Chocolate Dispenser

Manual / Handbuch Spare parts list / Ersatzteilliste

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

Puro Mini Dual Control Shower Mixer PU90010CP

Affix Model Number Label Here

ZIP HydroTap. User Manual

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

OP40R 40cm Remote Control Pedestal Fan

SCHWAN INSTALLATION GUIDE

Aqua & Instantaneous Electric Shower Installation Instructions SERVICE POLICY

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Streamline Undersink. Fitting Instructions and User Guide

INSTALLATION INSTRUCTIONS POINT OF USE WATER HEATERS EPU - HW

Karbon Kitchen Sink Tap

OT600E Tower Fan with Remote Control

Mira Atom ERD Thermostatic Bar Valve

The Classeq under counter range

AUTOMATIC GRANULAR ICE FLAKER

Manual and Thermostatic Power Shower Units

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

AQUABLEND 1500 SOLAR THERMOSTATIC MIXING VALVE

AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Plus Bath Shower Mixing Valve CP and PL30020CP

V80-H Multistage Pump Instruction Manual

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

GB24 & GB30. User Manual

T550i power shower pump Installation and operating instructions

Installation, Operating and Maintenance Guide

Installation and User Instructions HS10U, HS15U.

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

AUTOMATIC ICE-CUBE MAKER

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

JetSteam Iron Instruction Booklet BIR300

Convection Panel Heater

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

OPERATING AND INSTALLATION MANUAL

Installation Instructions

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

OPERATING & MAINTENANCE MANUAL DC10 DC15 DC25 DC40 DC45

Transcription:

Zip Tudor Installation Section & Operating Heading Instructions Single point open outlet (vented) water heaters Affix Model Number Label Here 81333 Above-Sink Tudor (No tapware included) Accessory Tapware for Under-Sink Tudors. Mono* Solo* Hero* Under-Sink Tudor * Accessory Tapware as indicated sold separately. Page 1 Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.01

# Read These Warnings First Please read all installation requirements, installation procedures and precautions before installing any Zip Tudor water heater. Never attempt to install any Zip Tudor water heater without reading all of the applicable instructions. Zip Tudor water heater is recommended for sinks and tubs, not recommended for basins. Zip Tudor water heaters are open outlet (vented) water heaters and must not be installed in the same way as mains pressure type water heaters. The outlet from any Zip Tudor water heater must be connected directly to an outlet spout on the sink and must not be obstructed by a tap or valve or in any other way. The water flow is controlled by a cold water tap connected before the water heater. Cold water pushes hot water out of the tank when the cold water tap is turned ON. Any such cold water tap should be labelled HOT. This water heater must not be connected to more than one outlet. All plumbing connections must be made in accordance with AS3500. The heater is intended only for indoor use and should never be installed outdoors or be exposed to the elements of nature. Over-sink and under-sink models are NOT interchangeable. The heater is unsuited for use by children or infirm people or those without experience; unless they have been given supervision or instruction by a person responsible for their safety. Children should be supervised to ensure they do not play with the heater. If the power supply cord is damaged it must be replaced by a Zip Service Provider or a qualified electrician. Do not remove the cover of the heater under any circumstances without first isolating the heater from the power supply. Outlet temperature should be set to no greater than 60 C without due regard to regulations governing the storage temperature of hot water. This unit must not be cleaned by a water jet Installation Requirements Before installing, ensure that the following are available: a) sufficient space to position the heater so there is 270 mm clear access under the heater (over-sink models) or 270mm above (under-sink). b) standard 10 amp 240 volt power outlet within 1500 mm of the heater c) cold water supply with a minimum working pressure of 50 kpa and a maximum working pressure of 350 kpa. d) Isolating valve (not supplied) If the pressure may exceed 350 kpa, a 350kPa pressure limiting valve (not supplied) must be installed in the cold water supply line. A double check valve (not supplied) is required to comply with the backflow requirements of AS/NZS3500.1 Under-sink models must be installed beneath approved vented mixer taps requiring a single mounting point on a sink, or tub. (Not recommended for basins) Water pressure under 100 kpa may be sufficient for over-sink heaters but may not operate under-sink mixer taps satisfactorily. Page 2 Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.03

Installation Procedure NOTE: Failure to correctly fit the Restrictaflow valve (provided) will void the warranty Step One - Tapware Note: Instructions for correct assembly and installation of Tudor tapware is included in the tapware box. Pay close attention to these instructions. Over-sink models must be installed with an inlet valve to control the flow from the water supply to the heater. No valve is supplied with the heater. The water supply and valve should be connected after fastening the heater to the wall. Over-sink models are supplied with a 300 mm swivel spout. A 300 mm to 600 mm telescopic swivel spout (99032) is available as an optional extra. Under-sink models must be installed with approved vented tapware. It is advisable to fit the tap to the sink before mounting the heater to the wall beneath the sink. 1. Install the Restrictaflow valve provided, with the isolating valve (not supplied), into the main cold water supply line. The Restrictaflow is adjustable and must be set to deliver no more than 6Ltr/min (Max.) NOTE: Do not fit the Restrictaflow valve to the tank (See P.5 diag) 2. Flush water supply pipes thoroughly to remove any silt or fines. 3. Fasten the tap body to the sink using the bolt & plate system provided. 4. The hose with a WHITE band on it connects to the tap hole with NO marking. 5. The hose with a RED band on it connects to the tap hole with a RED marking. 6. The hose with a BLUE band on it connects to the tap hole with a BLUE marking. 7. Ensure that the flexible tubes are firmly attached to the base of the tap body and in the correct sequence. Refer tapware installation sheet. Do not dismantle the assembled tap body during installation. Mixer taps are factory tested and sealed to provide optimum performance. To adjust water temperature delivered by Solo and Hero mixer taps, see instructions on page 7. Such adjustments should be made only by a qualified technician. Step Two - Positioning Over-sink heaters should be installed so that the outlet spout drains to a sink or tub, and with a clearance of 270 mm beneath the heater to allow for service access. Under-sink heaters should be installed a closely as possible to directly below the outlet tap with a clearance of 270 mm above the heater. This unit must not be positioned in an area that may be cleaned by a water jet. Step Three - Fastening It is not necessary to remove the case of the heater during installation. The heater must be wall mounted with two fixing screws as shown in the diagram on page 5. Fixing screws must have the strength to support the filled heater. The fixing screws are to protrude 4 mm from the wall as shown in the diagram on page 5 so as to fit into keyhole slots provided on the rear of the heater. Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.03 Page 3

Installation Procedure continued Model Weight (kg)) Empty Full Five Litre over-sink 3.5 8.5 Five Litre under-sink 3.5 8.5 Ten Litre over-sink 4.0 14.0 Ten Litre under-sink 4.0 14.0 Step Four - Connecting On over-sink models, the inlet and outlet are located on the base of the heater. On under-sink models, the inlet and outlet are located on the top of the heater. All Zip Tudor water connections are via 15 mm compression fittings and must be made strictly as shown in the diagrams. Over-sink models are supplied with a 300 mm open outlet spout, and must also be fitted with an isolation valve on the cold water side. A valve is not supplied with the heater and must be supplied and fitted by the installer. Under-sink models must be installed with approved vented tapware regulating the incoming water supply which displaces the hot water from the heater so it discharges through the open vented spout incorporated into the tap mounted on the sink or tub. The use of tapware other than approved vented tapware is dangerous. Each heater is equipped with a 1600 mm power cord and plug and should be connected to a standard 10 amp power outlet located adjacent to the heater. When correctly installed the plug must be accessible. Do not turn the power ON until the heater is filled with water and air is purged from the heater. Step Five - Commissioning Fill the heater tank and purge air from the heater by turning the water supply ON and running water through the heater until it flows smoothly. Turn the water supply OFF and turn the power supply ON. The heater will then run through its heating cycle. During the heating cycle, drips fall from the delivery spout or tap. Dripping will cease when the heating cycle is completed and the stored water temperature has reached the level set by the user. Retrofit instructions for open vented heaters NOTE: Failure to fit the recommended Restrictaflow valve will void the warranty Restrictaflow valve Flow restrictor If replacing an existing open vented water heater, an isolating valve must be fitted to the incoming water supply. A restrictaflow valve set at 6ltr/min (Max.), must be fitted to the outlet side of the isolating tap. (See diag on Page 5). NOTE It is essential that the tapware is the Open Vented type. If the aerator on the end of the tap is too restrictive. It must be removed. The installation requirements from page 2 are also applicable Page 4 Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.03

III I WIDTH 255 (5L) 310 (10L) Installation Procedure Continued DEPTH 215 (5L) 265 (10L) HEIGHT 390 (5L) 455 (10L) 125 (5L) 100 (10L) 265 (5L) 355 (10L) 140 FIXING HOLES WALL Tudor * I III E Open Outlet HOT OUT 100 COLD IN 70 Wall fixing details HOT OUT FRONT VIEW WIDTH 255 (5L) 310 (10L) ABOVE SINK INSTALLATION 100 COLD 70 IN SIDE VIEW DEPTH 215 (5L) 265 (10L) Wall Anchor Bolt Screw Head 4 mm gap 140 (5L) 180 (10L) ZIP Tudor * E HEIGHT 390 (5L) 455 (10L) 250 (5L) 275 (10L) 140 FIXING HOLES WALL FRONT VIEW SIDE VIEW UNDER SINK INSTALLATION Quick Installation Guide Step Two Position heater < 1 Metre from tap see page 3 Step One Install approved vented tapware see page 3 Step Five Commissioning. see page 4 before turning power on Cold Water Supply Isolation Valve (not supplied) Tudor Heater Restrictaflow see page 4 Step Three Fasten heater to wall see page 3 Step Four Connecting see Page 4. Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.03 Page 5

Operating Procedures Control Panel Water Temperature Zip Tudor water heaters are fully automatic, and may be left switched ON under the control of the variable thermostat. Nominal operating temperature can be varied from about 30 C to about 80 C. Temperature should not be set to less than 60 C without due regard to regulations governing the storage temperature of hot water. HIGH Economy Setting OFF The economy setting E will maintain stored water temperature at approximately 60 C. At the E setting, the temperature control locates into a set position and a slight resistance will be felt when rotating the temperature control beyond that setting. This measure is to help ensure that higher temperatures are only selected deliberately. ANTI- FREEZE Frost Protection If the heater is located where ambient air temperature could fall below 5 C when the heater is not in use, the anti freeze setting on the temperature control will maintain stored water temperature over 5 C to prevent freezing and damage to the water heater. ECONOMY LOW The same protection does not extend to connecting pipework or fittings. Safety Cutout Should the heater over-heat, a manually resettable safety cutout will automatically turn the heating element OFF. The cutout must be reset by a Zip Service Provider or a licensed electrician. Users should never reset the cutout without qualified assistance. Cleaning Never use strong, corrosive or abrasive cleaning materials. Wipe clean the outer surfaces with a sponge or soft cloth using a mild soap and water. Domestic dish washing liquid detergent is most suitable. Spare Parts PART NO DESCRIPTION 90401 element neck ring kit Tudor 90407 fascia kit Tudor undersink 90408 fascia kit Tudor oversink 90836 element kit 90420 pilot light kit Tudor 90421 thermostat kit Tudor 90423 overload kit Tudor Page 6 Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.01

# Service Procedures Knob removed to show screw Thermostat spade connectors This appliance may only be serviced by a suitably qualified technician. Disconnect from power and turn water supply OFF before attempting any kind of service work. Removing the case 1. Remove temperature control knob by gripping it and pulling towards you. 2. Remove the single retaining screw located beneath the temperature control knob. 3. Remove the four case screws two at top, two at bottom. 4. The case can now be lifted off carefully. Replacing the case Reverse of the above procedure. Replacing a thermostat 1. Remove the front cover. 2. Disconnect the two electrical terminals from the thermostat. These are spade connectors and can be easily pulled off. 3. Remove the two screws attaching the thermostat to the plastic upright. 4. Pull the capillary out of the thermostat pocket located on the element assembly. 5. Take the new thermostat (90421) and uncoil about half of the capillary tube. 6. Push the new capillary into the pocket ensuring that (for all models): a) The thermostat bulb is inserted first, before the safety cut out bulb. Attach the thermostat to the plastic upright. Reconnect the two electrical terminals. It does not matter which way around the connections occur. Ensure the remaining capillary coil is out of the way of any live terminals. Ensure the plastic upright is located securely in the position provided. Refit the cover assembly. # Tap Temperature Adjustment Adjustment of a tap temperature limiter on Solo and Hero vented taps should be made only by a Zip Service Provider or a qualified technician. End of life disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact your local city council for collection centre details Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.01 Page 7

Problem Solving Fault Possible cause Solution No heat No power Faulty element Faulty thermostat Faulty cutout Tripped overload Check power supply Contact Zip No water No supply Blockage Faulty thermostat Check water supply Contact Zip No indicator Faulty LED Faulty connection Contact Zip Contact Details Head Office Zip Heaters (Aust) Pty Ltd. ABN 46 000 578 727. 67 Allingham Street, Condell Park, NSW. 2200 Postal: Locked Bag 80 Bankstown 1885, Australia. Website: www.zipheaters.com Telephone: (02) 9796 3100 Facsimile: (02) 9796 3858 Free Call: 1800 638 633 Page 8 Zip Tudor - Installation & Operating Instructions - 81333 - May 2016 v1.01