Akiki Engineering Est.

Similar documents
Akiki Engineering Est.

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

Descaler & Prevention

NOBURST. NOBURST Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

Volume 10 Summer Understanding Terminology Key to Treatment Program Success

Water Treatment Improves Your Bottom Line DAVE PICOU WATER CARE SERVICES DIVISION JOHN SCHULTZ TEXTILE CARE DIVISON

Cleaning. Internal cleaning of refrigeration systems. Internal cleaning of heat transfer fluid circuits

BOILER SYSTEM CHEMICAL TREATMENT 101

Evaporative Cooling products

INDUSTRIAL GRADE WATER SOFTENERS LWT INDUSTRIAL SERIES

MODEL: LSS-280

Case Study and 700 HP Steam Boilers - Scale

Polymer Dilution Blend and Feed Specifications For General Use

Operation and Maintenance Haskris LX-Series, R-Series, WW-Series, OPC-Series

Commercial product range

INDUSTRIAL CONDENSATE POLISHERS. LWTCP Series

The Electronic Anti-Scale System Condominiums and Large Buildings

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

.2 Section Waste Management and Disposal..5 Section Cleaning and Startup of Mechanical Piping Systems.

Backpack CoilPro TM Coil Cleaner

Installation, Operation and Maintenance Manual

Recommendations Climalife

PIPING APPLICATION GUIDE

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

Industrial Processing Solutions

Digital Salt / TDS Meter. 390a. The Value Leader TM

How to Select and Size a Chiller

Installation, Operation and Maintenance Manual

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

Controller Specification Sheet

Installation, Operation and Maintenance Manual

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

HAVABLACK S2G BLACK OXIDE SALTS FOR IRON & STEEL

Other Things I Should Know?

GENERAL BULLETIN 08. A Division of Neptune Chemical Pump Company MIXER COMPANY

Common central heating problems

Membrane cleaning of RO-system with the isave unit

lindab we simplify construction Lindab Modular air handling units Service and maintenance manual

PRE INSTALLATION PROCEDURES

Sanosil disinfectants Use in CIP procedures

Water-Cooled Dual Compressor Screw Chiller

Installation, Operation and Maintenance Manual

AQUA ONE. Reverse Osmosis System Model ARO5000. Installation and Service Guide PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Industrial Descale Solutions & Descale Services

9.0 Systems For Domestic Water Installations

Blowdown Separator & Aftercoolers

Tier1 Water Home Filtration System

INSTALLATION MANUAL. Series 322 Ice Cube Machine SPECIFICATIONS UNPACKING. Series 322 Ice Cube Machine Installation Instructions

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

SPIROTECH BV PRESENTATION ON ENERGY EFFICIENT WET SYSTEMS

Pumps SELECTION OF A PUMP

Residential Application

Series 300 VTB. Installation Instructions

EcoCooler Legionella Risk Assessment Information Pack

Installation, Operation, and Maintenance Manual

A PRACTICAL GUIDE TO KUUL VITALITY EVAPORATIVE MEDIA MAINTENANCE AND SERVICE

Technical Specifications & Pricing

Scale Stopper Plus Installation & Start-Up Guide

Chiller Tube Cleaner Buying Guide

DEHYDRATION AND DESALTING

Strategies in Optimizing Condensate Return

Section 2. Product overview & label familiarisation

A PRACTICAL GUIDE TO KUUL CONTROL EVAPORATIVE MEDIA MAINTENANCE AND SERVICE

The Electronic Anti-Scale System For Hospitality Applications

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Boiler Additives And Filtration

INTAC PARTS & SERVICES ( H)

EZ CLEAN IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. External Aquarium Filter

FACT SHEET 3. Efficient Compressed Air Treatment. How to save energy, reduce costs and help the environment

S. P. THERMAL SYSTEMS INC.

Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Introduction to Heat Exchangers

QUALITY SYSTEMS MANUAL. Plant Hygiene

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

How about Savings in Time, Money, Energy and Longer Life?

HG-1500 Ozone Generator

INSTALLATION & MAINTENANCE MANUAL CSXT INSTANTANEOUS STEAM WATER HEATER Copyright 2006 PVI Industries, LLC

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Installation Instructions

APPLICATION NOTE NO. 2D Revised October Instructions for Care and Cleaning of Conductivity Cells

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

OPERATING AND MAINTENANCE MANUAL

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

Chemical treatments for paper production

METAL CHIP AND COOLANT MANAGEMENT PLANTS

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

Big Results Come From Our Smallest CoilPro

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

GEBRAUCHSANWEISUNG T-FLOW TRONIC MODE D'EMPLOI DU T-FLOW TRONIC USER INSTRUCTIONS T-FLOW TRONIC ИНСТРУКЦИЯ ПО ПРИМЕНЕНИЮ T-FLOW TRONIC

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Water Quality in Hydronic Systems April 16, 2015 with Guest Speaker Jim Poehling, P.E., LEED AP Q&A Documentation

METAL FINISHING WATER CONSERVATION. Presented by Mark Gentili

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Transcription:

Akiki Engineering Est. Water & Steam Experts 4.2. Cooling Tower Catalogue October 7, 2010

Contents Cooling Tower Chemical Products............................ 3 Cooling Towers Equipment(1).............................. 4 Cooling Towers Equipment(2).............................. 5 2

4.2.3 Chemical Treatment / Cooling Tower Cooling Tower Chemical Products CFR 2260 & CFR 2210 has a quick killing action, stability and dispersancy action of slime deposits makes it the most effective against LEGIONELLA. Other advantages: little volatility, extended stability, minimum reaction with organic corrosion and scale inhibitors. Akiki Engineering uses an alternation between two biocides: CFR 2260 & CFR 2210 Cooling Tower Treatment Benefit Features: Reduce maintenance cost and Prolong equipment life time Eliminate unscheduled shut down especially in hot season Reduce power cost, by maintaining deposit free surface of the heat exchangers Pipe Cleaner: CCH 4200 Liquid used to clean and flush loop containing dirty water and large amounts of rust and scale Remakes soluble the mineral deposit and disperse the none soluble particles You don t have to stop the installation, and on metallic surfaces, it has a passive action After the curative treatment, it is necessary to make a preventive treatment by using CVA 4110 (soft water) and biocide for microbiological control CFR 2260 Dosage rate: 1 % to 5 % of system volume Package: can of 20kg Anticorrosion & Antiscale: CFR 2110 A multifunctional liquid scale and corrosion inhibitor Complexes the hardness ions of water to avoid precipitation, and protects from corrosion by building up a film on the metallic surface Maintains in suspension mineral particles Will improve the efficiency to control microbial growth. Dosage rate is proportional to make-up water: 50-100 g/m3 in circuit Package: Can of 20 and 200 kg, container of 1000 kg Microbiological Control: CFR 2260 Used as preservative, bactericide, microbiocide, odour controller, and anti-fouling agent Used when there is a sterilisation Dosage is function of contamination state of the treated circuit, seasons, temperatures Sterilisation: 200 to 300 ppm, Maintenance: 100 to 150 ppm Storage: Keep away from freezing point Package: Can of 20, 25 and 230 kg Microbiological Control: CFR 2210 An agent to fight the micro organism; active against iron bacterial, legionella, and algaes. Dosage: 60 g/m3 of circuit; Storage: Keep away from freezing point Package: Can of 20 and 200 kg, container of 1000 kg 3 AKIKI Engineering

4.2.4 Chemical Treatment / Cooling Tower Cooling Towers Equipment(1) Controller Cold Water Meter Solenoid Valve Controller Digital readout display Control inhibitor feeding based on make-up volume Conductivity / ph function: Sensor, set point, high/low alarm Set points and alarms (Conductivity, ph) Control biocide-feeding program Furnish one microprocessor per independent closed system. Cold Water Meter Provide a make-up water meter sized the same as the make-up line A water meter is to be hard wired into the microprocessor controller, registering and accumulating total gallons of make-up water. Furnish a make-up water meter per each independent closed system Solenoid Valves Furnish a blowdown solenoid valve per independent tower water system. Blowdown valve is controlled by conductivity. When conductivity measured by the sensor becomes above the set point, a signal will initiate the solenoid valve to open and blow down is in progress. When conductivity measured by the sensor becomes below the set point, a signal will initiate the solenoid valve to close and blow down is stopped. Valve options: Normally closed Body & cap material: Cast iron Internal parts: Brass, stainless steel La Madonna Bldg, Saide Str., Ashrafieh, Beirut, Lebanon POB: 16-6979 Beirut, Lebanon 4 Web: www.akikieng.com Tel +961 1 339 322 Fax +961 1 330 491

4.2.5 Chemical Treatment / Cooling Tower Cooling Towers Equipment(2) Chemical Feeding Equipment Chemical Feeding Equipment We provide positive displacement diaphragm chemical metering pump with the following properties: Fully adjustable speed and stroke settings over the entire operating range Furnish two chemical metering pumps per independent closed system. One pump for inhibitor feed and one pump for biocide. Polyethylene chemical feed tank is provided. Each tank shall have a drum level switch agitator, incorporated in it. Also locally made chemical tanks can be provided Side Stream Filtration Unit Cooling Tower Side Stream Filtration Unit Including sand filter, filter pump, strainer and controls, factory assembled, piped and wired mounted to steel skid. Complete with all accessories and electrical panel board. Other series are also available AKIKI Engineering 5