MODELS 373LAV, 376CAV DOWNFLOW/HORIZONTAL and 383KAV, 395CAV UPFLOW GAS FURNACE

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

Installation Instructions

NOTE TO INSTALLER: This manual must be left with the equipment user. Model 480BAV Upflow and 481BAV Downflow/Horizontal

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Installation Instructions

Installation Instructions

GAS FURNACE. User's Information Manual for the operation and maintenance of model GB1AAV or GB3AAV Gas Furnace

Installation Instructions

Owner s Information Manual

Installation Instructions

Installation Instructions

Owner's Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Fig. 1 - Unit PGD4, PGS4, WPG4

Installation Instructions

Installation Instructions

Owner s Manual. ama PG9MXA TWO --- STAGE CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Installation Instructions

Installation Instructions

Residential Duct Mount Builder s Box Media Air Cleaner

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

Installation Instructions

Installation and Operating Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Owner s Manual. Induced Combustion Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION MANUAL LIST OF SECTIONS. 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5

Installation Instruction

Installation Instructions

Owner s Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner's Manual. Condensing Gas Furnace ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

HOME OWNER S INFORMATION Induced Combustion Gas Furnace

Installation Instructions

User s Information Manual

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE

Installation Instructions

Installation Instructions

Installation Instructions

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

INSTALLATION INSTRUCTIONS

Installation Instructions

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

GAS FURNACE USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

C7 Series Split System Uncased Indoor Coils

MODEL 340MAV, 350MAV, 352MAV, 355MAV CONDENSING GAS FURNACE

Installation Instructions

Installation Instructions

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

INSTALLATION INSTRUCTIONS

Owner s Manual PG9MAB ! WARNING. Condensing Gas Furnace NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

Owner s Manual CONDENSING GAS FURNACE ! WARNING NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

User s Information Manual

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Owner s Information Manual

Installation Instructions

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation Instructions

Installation Instructions

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Bosch 80% AFUE Gas Furnace BGS80 Model

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

Installation Instructions

Installation, Start-Up, and Operating Instructions

INSTALLATION INSTRUCTIONS TXV Coils EBU, EBA

INSTALLATION INSTRUCTIONS TXV Coils EBD, EBA

HOME OWNER S INFORMATION High Efficiency Condensing Gas Furnace

USER S INFORMATION MANUAL FOR OPERATION AND MAINTENANCE OF YOUR GAS-FIRED FURNACE

Transcription:

Heat Exchanger Cell Replacement Kit Cancels: IIK 373-35-12 IIK 373L-35-14 12-15-93 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION This instruction covers the installation of the heat exchanger cell kit Part No. 310203-752 in models 330AAV, 331AAV, 373LAV, 376CAV, 383KAV, 394HAD, 395CAV, 396HAD, 58DFA, 58DHC, 58GFA, 58PAP, 58PAV, 58RAP, 58RAV, 58SSC, 58TMA, 58TUA, 58WAV, 58ZAV, GA1AAD, GA2AAD, GB1AAV, and GB3AAV Gas Furnaces. SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained personnel should install or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils, or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, on tags, and on labels attached to the unit. Understand the signal word DANGER, WARNING, or CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard that could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions that will result in enhanced installation, reliability, or operation. Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. DESCRIPTION AND USAGE The heat exchanger cell replacement kit can be utilized to restore units having heat exchanger cells that require repair. This heat exchanger cell replacement kit contains the following items: Heat exchanger cell 1 Fiberglass gasket 2 Presstite (No. 582) sealant 1 Screw 9 Installation Instructions 1 INSTALLATION Step 1 Remove Heat Exchanger Assembly 1. Turn off gas and electrical supplies to unit. 2. Remove blower and control access doors. 3. Disconnect and remove vent pipe. 4. On hot surface ignition models: a. unplug control box connectors from blower deck. b. Unplug inducer motor. c. Disconnect wires from pressure switch, draft safeguard switch, and primary limit switch. d. Remove wires from retainer clip on casing side. NOTE: On hot surface ignition models, it is not necessary to disconnect wires from gas valve, limit over temperature switch, hot surface ignitor, or flame sensor. 5. On continuous-pilot models, disconnect all gas control compartment wiring and carefully feed wires down through the blower deck into the blower compartment. 6. Remove burner control assembly mounting screws and remove assembly from furnace. Be careful not to damage hot surface ignitor or flame sensor if applicable. 7. Remove screws securing relief box to top plate (upflow) or to blower shelf (downflow/horizontal). 8. Remove screws securing inducer assembly to cell panel and remove inducer assembly from furnace. 9. Remove auxiliary junction box and blower door interlock switch. 10. Remove screws securing cell panel to casing. 11. If necessary, remove 2 front screws of top plate (upflow) or 2 screws of bottom plate (downflow/horizontal). 12. Remove cell panel and attached heat exchanger cells through front of furnace. Step 2 Install Replacement Cell(s) 1. Determine which cell(s) need to be replaced. 2. Place heat exchanger on a flat surface with cell panel facing upward. 3. Remove 8 screws from cell opening of cell(s) being replaced. Remove and replace 1 cell at a time. NOTE: The word "top" is stamped on cell inlet plates to aid in correct assembly. 4. Using care not to damage insulation around inlet and outlet openings, remove cell from cell panel and discard. 5. Install new cell as follows: a. Center fiberglass insulation gaskets over inlet and outlet openings of cell. b. Tape each end of gasket to cell using short pieces of tape. c. Position cell under cell panel. d. Align holes and start ALL 8 screws. e. After all screws are started, check position of gaskets and cell inlet plates. When materials are properly aligned, tighten screws. 6. Cut away any insulation extending into cell openings. Do not drop pieces of insulation into cell. 7. Repeat Step 2, items 3 through 6, for additional cells being replaced. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-899 Printed in U.S.A. Form 58DFA-10SI Pg 1 12-93 Replaces: 58DFA-6SI Tab 6a 8a

Fig. 1 Replacement Cell A88384 4. If collector box sealant has been damaged, remove it and apply new sealant. Contact your distributor for proper sealant. Do not drop sealant into cell openings. 5. Reinstall inducer assembly. 6. Reinstall auxiliary junction box and blower door interlock switch. 7. Reinstall burner control assembly. Ensure that all burners are level. 8. Replace screws in top plate (upflow) or bottom plate (downflow/horizontal). 9. Reconnect all wiring using diagram located on blower access door. Put wiring behind retainer clip on casing side. 10. Reconnect gas pipe. 11. Reconnect vent pipe. 12. Reinstall blower access door. 13. Turn on gas supply and check for gas leaks. Never use a match or other open flame to check for gas leaks. Use a soap-and-water solution. Failure to follow this warning could result in fire, explosion, personal injury or death. 8. Remove baffles from old cells (if applicable) and install on new cells. See Fig. 2 and Table 1 or 2 for baffle location. NOTE: Failure to install baffles in proper location may cause premature heat exchanger failure and/or main limit cycling. Step 3 Reinstall Heat Exchanger Assembly NOTE: Check the insulation around the top, bottom, and sides of the cell panel. The insulation must overlap enough to provide a good air seal when the assembly is installed. 1. Slide heat exchanger assembly into furnace, engaging cells into cell support. Avoid bending any internal casing baffles when assembling. 2. Align holes and start screws. Ensure insulation stays in place to provide the necessary air seal. 3. Tighten screws into sides, top, and bottom of cell panel. WING BAFFLE 14. Turn on electrical supply. Step 4 Check for Air Leaks 1. Turn on blower only and block discharge air registers to create a high-static condition. 2. Using a match, check around cell inlet openings, inducer housing, flue collector box, and along sides and bottom of cell panel. 3. Seal any air leaks by pressing Presstite sealant (provided in kit) into area of air leak. 4. After completing air leak check, unblock discharge air registers. Operate furnace through 1 complete heating cycle and check for proper operation. 5. Using procedures in unit Installation Instructions, check input rate and temperature rise. 6. Reinstall gas control access door. 7. Set room thermostat to desired temperature. COLD SPOT BAFFLE 1 2 3 4 5 6 7 1 2 3 4 5 UPFLOW FURNACE DOWNFLOW/HORIZONTAL FURNACE Fig. 2 Baffle and Cell Location A90226 2

Table 1 Downflow Furnace Cold Spot Baffle Location UNIT* 373LAV036035 373LAV036050 376CAV036040 376CAV036050 GB3AAV036035 GB3AAV036050 58DHC040-GC 58RAV035-GC 58RAV050-12 58ZAV040-GC 58ZAV050-12 331AAV024065 373LAD024055 373LAD024070 396HAD024055 396HAD024070 GA2AAD024055 GA2AAD024070 58DFA055-EC 58DFA070-08 58RAP070-08 58RAP055-EC 58TMA065-08 331AAV036065 373LAD036055 373LAD036071 373LAV036055 373LAV036070 376CAV036055 376CAV036070 396HAD036055 396HAD036071 GA2AAD036055 GA2AAD036071 GB3AAV036055 GB3AAV036070 58DFA055-GC 58DFA071-12 58DHC055-GC 58TMA065-12 58RAP055-GC 58RAP071-12 58RAV055-GC 58RAV070-12 58ZAV055-GC 58ZAV070-12 331AAV060105 373LAV060090 373LAV060115 376CAV060095 376CAV060115 GB3AAV060090 GB3AAV060115 58DHC095-LC 58RAV090-LC 58RAV115-20 58TMA105-20 58ZAV095-LC 58ZAV115-20 Cells No. 1 and 2 Cell No. 2 Only Cells No. 1, 2, and 3 Cell No. 3 Only 3

UNIT* 373LAD060090 373LAD060110 396HAD060090 396HAD060110 GA2AAD060090 GA2AAD060110 58DFA090-LC 58DFA110-20 58RAP090-LC 58RAP110-20 331AAV060125 373LAD060105 373LAD060135 396HAD060105 396HAD060135 GA2AAD060105 GA2AAD060135 58DFA100-JC 58DFA100-LC 58DFA105-LC 58DFA135-20 58RAP105-LC 58RAP135-20 58TMA125-20 * Only models listed are equipped with cold spot baffles. Cells No. 2 and 4 Cells No. 3 and 4 4

Table 2 Upflow Furnace Wing Baffle Location UNIT * 330AAV036100 330AAV048100 383KAD036085 383KAD036105 383KAD048085 383KAD048105 383KAD066085 383KAD060105 383KAV036090 383KAV036110 383KAV048090 383KAV048111 394HAD036085 394HAD036105 394HAD048085 394HAD048105 394HAD066085 394HAD060105 395CAV036090 395CAV036110 395CAV048090 395CAV048111 GA1AAD036085 GA1AAD036105 GA1AAD048085 GA1AAD048105 GA1AAD066085 GA1AAD066105 GB1AAV036090 GB1AAV036110 GB1AAV048090 GB1AAV048111 58GFA085-GC 58GFA105-12 58GFA085-JC 58GFA105-16 58GFA085-MC 58GFA105-22 58PAP085-GC 58PAP105-12 58PAP085-JC 58PAP105-16 58PAP085-MC 58PAP105-22 58PAV090-GC 58PAV110-12 58PAV090-JC 58PAV111-16 58SSC090-GC 58SSC090-JC 58TUA100-12 58TUA100-16 58WAV090-GC 58WAV110-12 58WAV090-JC 58WAV111-16 Cells No. 2 and 4 5

UNIT * 330AAV060120 330AAV048120 383KAD048100 383KAD048130 383KAD060100 383KAD060130 383KAV048110 383KAV048135 383KAV060110 383KAV060135 394HAD048100 394HAD048130 394HAD060100 394HAD060130 395CAV048110 395CAV048135 395CAV060110 395CAV060135 GA1AAD048100 GA1AAD048130 GA1AAD060100 GA1AAD060135 GB1AAV048110 GB1AAV048135 GB1AAV060110 GB1AAV060135 58GFA100-JC 58GFA100-LC 58PAP100-JC 58PAP130-16 58PAP100-LC 58PAP130-20 58PAV110-JC 58PAV135-16 58PAV110-LC 58PAV135-20 58SSC110-JC 58SSC110-LC 58TMA125-20 58TUA120-16 58TUA120-20 58WAV110-JC 58WAV135-16 58WAV110-LC 58WAV136-20 330AAV060100 383KAV060090 (Series B only) 383KAV060111 (Series C only) 395CAV060090 (Series C only) 395CAV060111 (Series D only) GB1AAV060090 GB1AAV060111 58PAV090-LC (Series 111 only) 58PAV111-20 (Series 121 only) 58TUA100-20 58WAV090-LC 58WAV111-20 Cells No. 2 and 5 Cell No. 3 Only 6

UNIT * 330AAV060135 383KAD060120 383KAD060150 383KAV060125 383KAV060155 394HAD060120 394HAD060150 395CAV060130 395CAV060155 GA1AAD060120 GA1AAD060150 GB1AAV060125 GB1AAV060155 58GFA120-LC 58GFA150-20 58PAP120-LC 58PAP150-20 58PAV125-LC 58PAV155-20 58TUA135-20 58SSC130-LC 58WAV130-LC 58WAV155-20 * Only models listed are equipped with wing baffles. Cells No. 3 and 5 7

Copyright 1993 Carrier Corporation 15103 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 PC 101 Catalog No. 535-899 Printed in U.S.A. Form 58DFA-10SI Pg 8 12-93 Replaces: 58DFA-6SI Tab 6a 8a