Bryant Air Conditioning SINGLE PACKAGE HEAT PUMP S Model 655A Sizes 018-060 1 1 2 to 5 Tons DESCRIPTION Model 655A is our latest generation of packaged heat pumps for manufactured housing, residential, and light commercial applications. The model 655A design is the result of our firm commitment to the development of the finest comfort systems modern technology can offer. Our commitment is backed by our advanced engineering, testing, and research laboratories and our wealth of practical experience. Model 655A is designed in one basic cabinet size and features a round side-by-side duct configuration on sizes 018-048. Rectangular duct configuration is provided on the 060 size only. FEATURES FACTORY-ASSEMBLED PACKAGE is a compact, fully selfcontained, heat pump unit that is prewired, prepiped, and precharged for minimum installation expense. 655A units are available in a variety of standard sizes with voltage options to meet residential and light commercial requirements. Unit installs easily on a rooftop or a ground-level pad. The optional base rail provides an elevated base. CONVERTIBLE DUCT CONFIGURATION on the 655A is designed for easy use in either downflow or horizontal discharge applications. HIGH-EFFICIENCY DESIGN with SEERs (Seasonal Energy Efficiency Ratios) up to 10.1 and HSPFs (Heating Seasonal Performance Factors) of up to 7.0. DURABLE, DEPENDABLE COMPRESSORS are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Vibration isolation provides quiet operation. Reciprocating or scroll compressors are used. Compressors have internal high-pressure and overcurrent protection. DIRECT-DRIVE MULTISPEED, PSC (permanent split capacitor) BLOWER MOTOR is standard on all models. DIRECT-DRIVE, PSC OUTDOOR-FAN MOTORS are designed to help reduce energy consumption and provide for cooling operation down to 40 F. REFRIGERANT SYSTEM is designed to provide dependability. Liquid refrigerant strainers are used to promote clean, unrestricted operation. Sizes 018 through 042 include an accumulator (unnecessary on 048 and 060 sizes, which feature scroll compressors). All units feature a proven-reliable reversing valve. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. CRANKCASE HEATER (sizes 018 through 042) reduces start-up wear by keeping lubricant at an optimum temperature. Not required on scroll compressor models (048 and 060). INDOOR AND OUTDOOR COILS are computer-designed for optimum heat transfer and cooling efficiency. Outdoor coil is fabricated of copper tube and aluminum fins and is located inside the unit where it is protected against damage for long life and reliable operation. Copper fin coils are also available by special order. These coils are recommended in applications where aluminum fins are likely to be damaged due to corrosion, for example, seacoast installations. WEATHERIZED CABINETS are constructed of heavy-duty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the indoor compartment are insulated with aluminum foil faced insulation to help keep the conditioned air from being affected by the outdoor ambient temperature. (Conforms to ASHRAE 62P.) Sloped condensate pan permits an external drain. LOW SOUND RATINGS ensure a quiet indoor and outdoor environment with sound ratings as low as 7.8 bels. EASY TO SERVICE CABINETS provide easy accessibility to serviceable components during maintenance and installation. Rounded corners are an important safety feature, and a highquality finish ensures an attractive appearance. OPTIONAL BASE RAIL S provide holes for rigging and handling as well as an elevated mounting frame that gives additional structural support to horizontal applications. ROUND DUCT CONNECTIONS provide easy installation for manufactured housing. DOWNFLOW OPTION is converted for downflow at the factory for easy vertical ductwork connections. FACTORY-INSTALLED OPTIONS DESCRIPTION AND USAGE Unit With Base Rail Unit has rigging holes and an elevated mounting frame. Rigging holes to provide greater ease in handling. Frame to provide greater structural support for horizontal applications. Downflow Option Unit is shipped configured for downflow application. Unit is equipped with base rail. To provide easy vertical ductwork connections. Form No. PDS 655A.18.2B
FIELD-INSTALLED ACCESSORY DESCRIPTION AND USAGE Flat Roof Curb Consists of galvanized steel support frame in 8-, 11-, and 14-in. high designs. Provides wood nailer to attach roof counter flashing. Insulated basepans in curbs are provided to prevent condensation. Ductwork attaches to rails provided in the roof curb. A gasket is provided to form an airtight and watertight seal between unit and curb. The roof curb design meets the standards of the NRCA (National Roofing Contractors Association). Slab-mounted applications when elevation of the unit above the slab is necessary. Rooftop application for downflow discharge. Curbs are preassembled and are available for flat or pitched roofs. Pitched Roof Curb Provided in ratios of 1, 2, 3, 4, 5, and 6 to 12 for use on pitched roof applications. For when a roof curb is needed on a pitched roof. Modulating Economizers Economizers are available for downflow or horizontal applications, and are designed for easy installation. Economizers reduce energy costs and extend equipment life by allowing the use of outdoor air to supply free cooling when conditions are favorable. Constant ventilation is recommended for light commercial applications when the conditioned space is occupied. All economizers are shipped complete with a damper motor and linkage, enthalpy control, low-voltage wiring harness, and a rainhood. Adequate wire lengths are provided (additional fieldsupplied wires are not required). Horizontal economizers are also furnished with a 2-in. disposable air filter and gasket material. Modulating economizer package consists of low-leakage dampers with controls. The economizer will allow outdoor ventilation air into the unit whenever the evaporator fan is running. Allows outdoor air to be used for free cooling whenever the outdoor air is below the enthalpy control setting. To reduce energy usage. Use whenever the hours of operation at temperatures below 40 F are significant. Two-Position Damper In the two-position dampers, the enthalpy control detects when outdoor air is suitable for free cooling by measuring the outdoor-air dry bulb temperature and humidity. Whenever the outdoor-air quality is acceptable for free cooling, the outdoor-air damper opens fully and the return-air damper closes, allowing outdoor air to enter the building. Allows use of outdoor air to cool building without using compressor. Damper closes when indoor fan is off to prevent cold backdraft, and wasted energy. Manual Outdoor-Air Damper Package consists of an adjustable damper which can be set at different positions. The package includes a rainhood and birdscreen. To allow a fixed percentage of outdoor air for ventilation under all conditions. The damper may be used on either downflow or horizontal airflow applications. Thermostat and Subbase These accessories provide cooling control for unit. Autochangeover and manual changeover types are available. To operate and control unit, and to maintain desired building temperature. The 0 F Low Ambient Kit Kit permits operation down to 0 F. When mechanical cooling is required when outdoor-air temperature is between 40 F and 0 F. Filter Rack Rack features easy installation and serviceability. The filter rack housing is constructed of heavy-gage steel and is fully insulated. Both sides of the filter rack are flanged for easy installation. Kit provides ability to locate filters outside the building. Rectangular Duct Connection Kit Kit consists of a sheet metal transition and hardware for mounting. Allows easy conversion from round to rectangular ducts. Duct Cover Kit Kit consists of a panel which covers and seals horizontal duct openings. To cover horizontal ducts after unit has been converted to downflow discharge. Lifting Bracket Kit Provides attachment point for rigging straps. When unit needs to be lifted or moved. The kit is not required when unit is equipped with optional base rail or downflow application. High- and Low-Pressure Switches Protect the unit from running at unsuitable pressures. Provides additional safety features when needed. Outdoor Thermostat Accessory provides control when outdoor-air temperature falls below set point. To bring second stage of 2-stage electric heat on line. Electric Heater Heater module slides into keyed mounting slots in the fan inlet. Heater sizes range from 5.0 to 20.0 kw. Design allows for single-point supply for entire unit. To provide heating capability when required. Efficiency Alarm Kit Device Energizes a warning light located on the indoor thermostat. To provide warning when the compressor fails to operate after a call for heating or cooling. CONTENTS Page Model Description...3 ARI Capacities...3 Dimensional Drawings...4-8 Specifications...9 Selection Procedure...9 Cooling Capacities...10-12 Heating Capacities...12-15 Air Delivery...16,17 Electric Heater Data...19,20 Electrical Data...22 Operating Sequence...23 Typical Single-Phase Wiring Schematic...24 Typical Installation...25 Engineers Specification Guide... 26 2
MODEL DESCRIPTION 655A NOMINAL TONS ARI* CAPACITIES PRELIMINARY COOLING AND HEATING CAPACITIES AND EFFICIENCIES STANDARD CFM NET COOLING CAPACITIES AT 95 F (Btuh) SEER NET HEATING CAPACITIES AT 47 F (Btuh) COP (at 47 F Btuh) NET HEATING CAPACITIES (at 17 F Btuh) COP (at 17 F Btuh) HSPF SOUND RATINGS** (Bels) 018 1 1 2 675 19,000 10.0 17,800 2.9 9,300 1.7 6.6 7.8 024 2 750 24,000 10.0 23,600 2.9 12,000 1.8 6.7 8.0 030 2 1 2 1000 29,000 10.0 29,400 3.0 15,000 1.8 6.8 8.0 036 3 1270 35,600 10.1 35,400 3.1 17,400 1.8 6.8 8.0 042 3 1 2 1390 40,500 10.0 40,500 3.1 21,000 1.9 7.0 8.2 048 4 1575 47,000 10.1 47,500 3.1 27,200 2.0 7.0 8.2 060 5 1995 57,500 10.0 57,000 3.2 32,000 2.0 7.0 8.2 Bels Sound Levels (1 bel = 10 decibels) COP Coefficient of Performance DOE Department of Energy HSPF Heating Seasonal Performance Factor SEER Seasonal Energy Efficiency Ratio *Air Conditioning & Refrigeration Institute. Rated in accordance with ARI Standard 210/240-89 and/or U.S. Government DOE test procedures. **Rated in accordance with ARI Standard 270-84. OUTDOOR SOUND: ONE-THIRD OCTAVE BAND DATA DECIBELS FREQ. 655A Hz 018 024 030 036 042 048 060 63 40.1 49.6 46.8 47.6 50.0 53.2 54.3 125 55.2 60.1 61.3 62.1 64.7 65.4 65.1 250 64.9 70.1 70.5 70.4 70.4 74.5 71.5 500 65.3 68.3 69.2 69.0 69.9 74.3 72.7 1000 71.2 72.6 74.1 72.2 75.3 75.2 73.9 2000 69.0 69.4 70.0 71.1 73.8 72.6 73.4 4000 64.7 67.8 68.9 70.3 75.1 68.6 71.7 8000 59.8 60.9 64.0 63.9 69.2 61.2 66.3 3
DIMENSIONAL DRAWINGS ELECTRICAL CHARACTERISTICS WT CORNER WT (Lb/Kg) HEIGHT (in./mm) DIMENSION (in./mm) Lb Kg A B C D E F 655A018 208/230-1-60 248 106 66/30 45/20 95/43 42/19 24.1/613 18.2/462 655A024 208/230-1-60 256 117 68/31 46/21 97/44 45/20 24.1/613 18.2/462 655A030 208/230-1-60, 208/230-3-60 268 122 66/30 58/26 91/41 53/24 24.1/613 18.2/462 655A036 208/230-1-60, 208/230-3-60, 460-3-60 288 131 71/32 63/29 96/44 58/26 28.1/714 22.2/563 655A042 208/230-1-60, 208/230-3-60, 460-3-60 295 134 73/33 65/30 97/44 60/27 28.1/714 22.2/563 CENTER OF GRAVITY (in./mm) X Y Z 655A018 20.7/525 19.2/487 10.6/270 655A024 20.4/517 19.3/491 10.6/270 655A030 20.3/515 20.1/510 10.6/270 655A036 20.1/511 20.2/513 12.4/314 655A042 20.0/509 20.3/516 12.4/314 REQ D CLEARANCES FOR SERVICING in. (mm) Indoor Coil Access Side................. 30 (762) Control Box Access Side................ 30 (762) (Except for NEC requirements) Unit Top......................... 36 (914) Side Opposite Ducts.................. 30 (762) REQ D CLEARANCES TO COMBUSTIBLE MAT L in. (mm) Unit Top............................. 0 Duct Side of Unit........................ 0 Side Opposite Ducts...................... 0 Bottom of Unit......................... 0 Vertical Discharge, First 12 in. (305) of Supply Duct... 1 (25) NEC REQ D CLEARANCES in. (mm) Between Units, Control Box Side........... 42 (1067) Unit and Ungrounded Surfaces, Control Box Side... 36 (914) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side........ 42 (1067) CG Center of Gravity MAT L Material NEC National Electrical Code REQ D Required NOTE: Clearances must be maintained to prevent recirculation of air from outdoor-fan discharge. Unit 655A Sizes 018-042 Without Base Rail 4
DIMENSIONAL DRAWINGS (cont) ELECTRICAL CHARACTERISTICS WT CORNER WT (Lb/Kg) HEIGHT (in./mm) DIMENSION (in./mm) Lb Kg A B C D E F 655A018 208/230-1-60 268 122 70/32 50/23 100/45 48/22 27.4/697 21.5/546 655A024 208/230-1-60 276 125 73/33 51/23 102/46 50/23 27.4/697 21.5/546 655A030 208/230-1-60, 208/230-3-60 288 131 71/32 63/29 96/44 58/26 27.4/697 21.5/546 655A036 208/230-1-60, 208/230-3-60, 460-3-60 308 140 76/35 68/31 101/46 63/29 31.4/798 25.5/648 655A042 208/230-1-60, 208/230-3-60, 460-3-60 315 143 78/35 70/32 102/46 65/30 31.4/798 25.5/648 CENTER OF GRAVITY (in./mm) X Y Z 655A018 20.4/518 19.4/493 12.9/329 655A024 20.2/513 19.5/495 12.9/329 655A030 20.1/511 20.2/513 12.9/329 655A036 20.0/508 20.3/515 14.7/373 655A042 19.9/506 20.4/518 14.7/373 REQ D CLEARANCES FOR SERVICING in. (mm) Indoor Coil Access Side................. 30 (762) Control Box Access Side................ 30 (762) (Except for NEC requirements) Unit Top......................... 36 (914) Side Opposite Ducts.................. 30 (762) REQ D CLEARANCES TO COMBUSTIBLE MAT L in. (mm) Unit Top............................. 0 Duct Side of Unit........................ 0 Side Opposite Ducts...................... 0 Bottom of Unit......................... 0 Vertical Discharge, First 12 in. (305) of Supply Duct... 1 (25) NEC REQ D CLEARANCES in. (mm) Between Units, Control Box Side........... 42 (1067) Unit and Ungrounded Surfaces, Control Box Side... 36 (914) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side........ 42 (1067) CG Center of Gravity MAT L Material NEC National Electrical Code REQ D Required Unit 655A Sizes 018-042 With Optional Base Rail 5
DIMENSIONAL DRAWINGS (cont) ELECTRICAL WT CORNER WT (Lb/Kg) CHARACTERISTICS Lb Kg A B C D 655A048 208/230-1-60, 208/230-3-60, 460-3-60 359 163 89/40 81/37 113/51 76/35 655A060 208/230-1-60, 208/230-3-60, 460-3-60 373 170 92/42 85/39 116/53 80/36 CENTER OF GRAVITY (in./mm) X Y Z 655A048 19.7/500 20.5/522 15.0/381 655A060 19.7/499 20.6/523 15.0/381 REQ D CLEARANCES FOR SERVICING in. (mm) Indoor Coil Access Side................. 30 (762) Control Box Access Side................ 30 (762) (Except for NEC requirements) Unit Top......................... 36 (914) Side Opposite Ducts.................. 30 (762) REQ D CLEARANCES TO COMBUSTIBLE MAT L in. (mm) Unit Top............................. 0 Duct Side of Unit........................ 0 Side Opposite Ducts...................... 0 Bottom of Unit......................... 0 Vertical Discharge, First 12 in. (305) of Supply Duct... 1 (25) NEC REQ D CLEARANCES in. (mm) Between Units, Control Box Side........... 42 (1067) Unit and Ungrounded Surfaces, Control Box Side... 36 (914) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side........ 42 (1067) CG Center of Gravity MAT L Material NEC National Electrical Code REQ D Required NOTE: Clearances must be maintained to prevent recirculation of air from outdoorfan discharge. Unit 655A Sizes 048,060 Without Base Rail 6
DIMENSIONAL DRAWINGS (cont) ELECTRICAL WT CORNER WT (Lb/Kg) CHARACTERISTICS Lb Kg A B C D 655A048 208/230-1-60, 208/230-3-60, 460-3-60 379 172 94/43 86/39 118/54 81/37 655A060 208/230-1-60, 208/230-3-60, 460-3-60 393 179 97/44 90/41 121/55 85/39 CENTER OF GRAVITY (in./mm) X Y Z 655A048 19.6/498 20.6/524 17.3/440 655A060 19.6/497 20.6/524 17.3/440 REQ D CLEARANCES FOR SERVICING in. (mm) Indoor Coil Access Side................. 30 (762) Control Box Access Side................ 30 (762) (Except for NEC requirements) Unit Top......................... 36 (914) Side Opposite Ducts.................. 30 (762) REQ D CLEARANCES TO COMBUSTIBLE MAT L in. (mm) Unit Top............................. 0 Duct Side of Unit........................ 0 Side Opposite Ducts...................... 0 Bottom of Unit......................... 0 Vertical Discharge, First 12 in. (305) of Supply Duct... 1 (25) NEC REQ D CLEARANCES in. (mm) Between Units, Control Box Side........... 42 (1067) Unit and Ungrounded Surfaces, Control Box Side... 36 (914) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side........ 42 (1067) CG Center of Gravity MAT L Material NEC National Electrical Code REQ D Required NOTE: Clearances must be maintained to prevent recirculation of air from outdoorfan discharge. Unit 655A Sizes 048,060 With Optional Base Rail 7
DIMENSIONAL DRAWINGS (cont) Flat Pitched PART NUMBER A B PITCH 389099-701 8 [203] 389100-701 11 [279] 389101-701 14 [356] 389103-701 8 [203] 10 7 8 [276] 1 : 12 389104-701 8 [203] 13 9 16 [344] 2 : 12 389105-701 8 [203] 16 3 8 [416] 3 : 12 389106-701 8 [203] 19 1 4 [489] 4 : 12 389107-701 8 [203] 22 3 8 [568] 5 : 12 389108-701 8 [203] 25 5 8 [651] 6 : 12 NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied as required for unit being installed. 3. Dimensions in [ ] are in millimeters. 4. Roof curb is made of 16 gage steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance 4 ft on each side. 7. Direction of airflow. 8. Insulated panels: 1-in. thick fiberglass, 1-lb density. Roof Curb Dimensions 8
SPECIFICATIONS 655A 018 024 030 036 042 048 060 REFRIGERANT R-22 Refrigerant Control* Fixed Orifice Metering Device SHIPPING WEIGHT (lb) Without Base Rail 300 308 320 340 347 411 425 With Optional Base Rail 287 295 307 327 334 398 412 COMPRESSOR TYPE Reciprocating Reciprocating Reciprocating Reciprocating Reciprocating Scroll Scroll INDOOR FAN Centrifugal Direct Drive Speeds 2 3 3 3 2 2 2 Rpm (High Speed) 825 1025 1025 1100 1100 1100 1100 Diameter (in.) 10 10 10 10 10 10 11 Width (in.) 9 9 9 9 9 9 9 Nominal Airflow (Cfm) 675 800 1000 1300 1400 1600 1995 Motor Hp 1 4 1 4 1 3 1 2 3 4 3 4 1 INDOOR COIL Rows...Fins/in. 3...15 3...15 3...15 3...15 3...15 3...15 4...15 Face Area (sq ft) 1.83 2.29 3.06 2.70 3.60 4.50 4.50 OUTDOOR FAN Propeller Direct Drive Cfm 1700 1900 1900 1900 1900 2400 2400 Rpm 850 1050 850 1050 1050 1050 1050 Diameter (in.) 18 18 18 18 20 20 20 Motor Hp 1 8 1 4 1 4 1 4 1 4 1 3 1 3 OUTDOOR COIL Rows...Fins/in. 2...17 2...17 2...17 2...17 2...17 2...17 2...17 Face Area (sq ft) 5.65 5.65 5.65 6.70 6.70 8.20 8.20 FILTER SIZE (in.) Throwaway 20x20 20x20 20x24 24x24 24x24 24x30 24x30 *Operating charge listed on unit nameplate. Recommended field-supplied filters are 1 in. thick. SELECTION PROCEDURE I DETERMINE COOLING AND HEATING REQUIRE- MENTS AT DESIGN CONDITIONS. Given: Required Cooling Capacity (TC)... 28,000 Btuh Sensible Heat Capacity (SHC)... 20,500 Btuh Required Heating Capacity...28,550 Btuh Outdoor Entering-Air Temperature...95F Outdoor-Air Winter Design Temperature...20F Indoor-Air Winter Design Temperature...70F Indoor Entering-Air Temperature...80Fedb, 67 F ewb Indoor-Air Quantity...1125cfm External Static Pressure...0.40 in. wg Electrical Characteristics (V-Ph-Hz)... 230-1-60 edb entering dry bulb ewb entering wet bulb II SELECT BASED ON REQUIRED COOLING CAPACITY. Enter Cooling Capacities table at condenser entering temperature of 95 F, indoor air entering at 1125 cfm and 67 F ewb (entering wet bulb). The 655A030 unit will provide a total cooling capacity of 29,300 Btuh and a sensible heat capacity of 22,100 Btuh. For indoor-air temperature other than 80 F edb (entering dry bulb), calculate sensible heat capacity correction, as required, using the formula found in Note 3 following the cooling capacities tables. NOTE: Unit ratings are net capacities. III SELECT ELECTRIC HEAT. Enter the Heating Capacities table, page 13 at 1125 cfm. At 70 F return indoor air and 20 F air entering outdoor coil, the integrated heating capacity is 14,900 Btuh. (Select integrated heating capacity value since deductions for outdoor-coil frost and defrosting have already been made. No correction is required.) The required heating capacity is 28,550 Btuh. Therefore, 13,650 Btuh (28,550 14,900) additional electric heat is required. Determine additional electric heat capacity in kw. 13,650 Btuh = 4.0 kw of heat required 3414 Btuh/kW Enter the Electric Heater Packages table on page 19 for 208/240 v, single-phase, 655A030 unit. The 5-kW heater at 240 v most closely satisfies the heating required. To calculate kw at 230 v, multiply the heater kw by multiplication factor 0.92 found in the Wattage Multiplication Factors table on page 21. 5 kw x.92 = 4.6 kw 4.6 x 3414 = 15,704 Btuh To calculate kw at 208 v, see note below Electric Heater Packages table on page 19. Total unit heating capacity is 30,604 Btuh (14,900 + 15,704). IV DETERMINE FAN SPEED AND POWER REQUIRE- MENTS AT DESIGN CONDITIONS. Before entering the air delivery tables, calculate the total static pressure required. From the given, the Accessory Electric Heat Pressure Drop table, the Wet Coil Pressure Drop table, and the Filter Pressure Drop table, find: External static pressure 0.40 in. wg Filter 0.11 in. wg Electric heat 0.04 in. wg Wet coil 0.11 in. wg Total static pressure 0.66 in. wg Enter the table for Dry Coil Air Delivery Horizontal Discharge on page 16 at 1125 cfm and 230-v high speed. By interpolation, the standard motor will deliver 0.66 in. wg static pressure. This will adequately adequately handle job requirements. 9
COOLING CAPACITIES 655A018 (1 1 2 TONS) Indoor Outdoor Air Temperature (F) Air 85 95 105 115 Cfm BF F Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Ewb Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible 525 0.05 675 0.07 750 0.07 Compressor kw 72 21.7 10.0 1.94 20.8 9.8 2.07 19.5 9.4 2.19 18.1 8.9 2.31 67 19.6 12.8 1.90 18.4 12.3 2.01 17.0 11.8 2.12 15.6 11.3 2.23 62 17.2 15.1 1.85 16.0 14.5 1.95 14.7 13.9 2.05 13.5 13.3 2.15 63* 17.9 12.3 1.86 16.7 11.8 1.96 15.4 11.2 2.07 14.1 10.7 2.16 72 22.3 10.8 2.01 21.4 10.6 2.14 20.1 10.3 2.27 18.7 9.8 2.39 67 20.3 14.2 1.97 19.0 13.8 2.09 17.0 13.4 2.20 16.1 12.8 2.31 62 18.0 17.1 1.92 16.8 16.5 2.04 15.6 15.6 2.15 14.6 14.6 2.26 63* 18.7 13.8 1.93 17.3 13.3 2.04 15.9 12.7 2.15 14.5 12.2 2.25 72 22.2 10.9 2.03 21.5 10.9 2.17 20.2 10.6 2.30 18.8 10.2 2.42 67 20.5 14.9 2.01 19.2 14.6 2.13 17.8 14.1 2.24 16.3 13.6 2.35 62 18.3 17.9 1.96 17.1 17.1 2.08 16.1 16.1 2.19 15.0 15.0 2.31 63* 18.8 14.5 1.96 17.5 14.0 2.08 16.1 13.4 2.18 14.6 12.8 2.28 655A024 (2 TONS) Indoor Air Cfm BF 700 0.04 800 0.05 900 0.06 F Ewb Outdoor Air Temperature (F) 85 95 105 115 Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible Compressor kw 72 28.6 13.0 2.66 26.9 12.4 2.79 25.2 11.9 2.92 23.4 11.3 3.04 67 25.2 16.2 2.58 23.6 15.6 2.70 21.9 15.0 2.82 20.1 14.4 2.93 62 21.9 19.3 2.49 20.4 18.6 2.61 18.8 17.9 2.72 17.4 17.1 2.82 63* 23.0 15.6 2.51 21.4 15.0 2.63 19.8 14.4 2.73 18.2 13.7 2.83 72 29.1 13.6 2.72 27.4 13.0 2.85 25.6 12.5 2.98 23.8 11.9 3.11 67 25.7 17.3 2.64 24.0 16.7 2.76 22.2 16.1 2.88 20.5 15.4 2.99 62 22.4 20.7 2.55 20.8 19.9 2.67 19.3 19.1 2.78 18.0 18.0 2.90 63* 23.5 16.7 2.57 21.8 16.0 2.69 20.1 15.3 2.80 18.4 14.7 2.89 72 29.5 14.1 2.77 27.7 13.5 2.90 25.9 13.0 3.04 24.0 12.5 3.16 67 26.0 18.3 2.69 24.3 17.7 2.82 22.5 17.0 2.93 20.6 16.4 3.04 62 22.7 21.9 2.61 21.2 21.0 2.73 19.9 19.9 2.86 18.6 18.6 2.97 63* 23.8 17.6 2.62 22.1 16.9 2.74 20.4 16.3 2.85 18.6 15.6 2.95 655A030 (2 1 2 TONS) Indoor Air Cfm BF 875 0.05 1000 0.06 1125 0.06 F Ewb Outdoor Air Temperature (F) 85 95 105 115 Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible Compressor kw 72 34.1 16.0 3.24 32.3 15.4 3.43 30.2 14.7 3.59 27.9 14.0 3.74 67 30.5 20.3 3.17 28.6 19.6 3.34 26.5 18.8 3.49 24.4 18.0 3.62 62 26.8 24.2 3.09 25.1 23.4 3.25 23.3 22.5 3.39 21.5 21.5 3.51 63* 27.9 19.6 3.11 26.1 18.8 3.27 24.2 18.1 3.40 22.3 17.3 3.52 72 34.5 16.6 3.31 32.8 16.1 3.49 30.7 15.5 3.66 28.3 14.8 3.81 67 31.0 21.6 3.24 29.0 20.9 3.41 26.9 20.1 3.56 24.7 19.3 3.70 62 27.4 25.9 3.16 25.6 25.0 3.33 23.9 23.8 3.47 22.3 22.3 3.61 63* 28.5 20.8 3.17 26.5 20.1 3.34 24.6 19.3 3.48 22.5 18.4 3.60 72 34.9 17.2 3.37 33.1 16.7 3.56 31.0 16.1 3.73 28.6 15.5 3.88 67 31.4 22.8 3.31 29.3 22.1 3.48 27.1 21.3 3.63 24.9 20.5 3.77 62 27.8 27.3 3.23 26.1 26.1 3.40 24.6 24.6 3.56 23.0 23.0 3.71 63* 28.8 22.0 3.24 26.8 21.2 3.40 24.8 20.4 3.55 22.7 19.6 3.67 BF Bypass Factor Ewb Entering Wet Bulb ldb Leaving Dry Bulb lwb Leaving Wet Bulb *At 75 F entering dry bulb (edb) (Tennessee Valley Authority [TVA] rating conditions); all others at 80 F. NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: tldb =tewb sensible capacity (MBtuh x 1000) 1.10 x cfm tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving indoor coil (hlwb) total capacity (MBtuh x 1000) hlwb=hewb 4.5 cfm Where: hewb = Enthalpy of air entering indoor coil 3. The sensible heat capacity is based on 80 F edb temperature of air entering indoor coil. Below 80 F edb, subtract (corr factor x cfm) from the sensible heat capacity. Above 80 F edb, add (corr factor x cfm) to the sensible heat capacity. Correction Factor = 1.10 x (1 BF) x (edb 80). 10
655A036 (3 TONS) Indoor Air Cfm BF 1050 0.10 1300 0.13 1500 0.14 F Ewb COOLING CAPACITIES (cont) Outdoor Air Temperature (F) 85 95 105 115 Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible Compressor kw 72 40.1 19.8 3.80 38.2 19.2 4.02 36.1 18.5 4.25 33.8 17.7 4.46 67 36.8 25.4 3.70 34.6 24.6 3.90 32.4 23.7 4.09 30.1 22.8 4.28 62 33.1 30.4 3.59 31.1 29.3 3.77 29.1 28.2 3.94 27.2 27.0 4.12 63* 33.9 24.6 3.62 31.7 23.6 3.80 29.6 22.7 3.97 27.5 21.8 4.14 72 40.8 20.9 3.92 38.8 20.4 4.15 36.9 20.0 4.39 34.6 19.3 4.62 67 37.7 27.9 3.83 35.6 27.1 4.04 33.3 26.3 4.24 30.9 25.3 4.43 62 34.4 33.4 3.74 32.4 32.1 3.94 30.5 30.5 4.13 28.7 28.7 4.32 63* 34.9 27.0 3.76 32.6 26.1 3.95 30.4 25.1 4.12 28.1 24.1 4.29 72 41.4 22.0 4.03 39.7 21.8 4.28 37.1 20.8 4.48 34.8 20.3 4.71 67 38.2 29.6 3.93 36.1 29.0 4.15 33.7 28.1 4.35 31.2 27.1 4.54 62 35.3 35.3 3.86 33.4 33.4 4.07 31.6 31.6 4.27 29.7 29.7 4.47 63* 35.5 28.8 3.87 33.1 27.8 4.05 30.8 26.8 4.23 28.5 25.8 4.40 655A042 (3 1 2 TONS) Indoor Air Cfm BF 1225 0.07 1400 0.08 1575 0.09 F Ewb Outdoor Air Temperature (F) 85 95 105 115 Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible Compressor kw 72 46.1 22.5 4.66 43.6 21.6 4.92 41.0 20.8 5.17 38.5 19.9 5.44 67 41.8 28.9 4.51 39.3 28.0 4.77 36.9 27.0 5.00 34.4 26.0 5.23 62 37.4 34.5 4.35 35.2 33.4 4.58 33.0 32.2 4.81 30.9 30.8 5.04 63* 38.4 27.9 4.39 36.1 26.9 4.62 33.7 25.9 4.84 31.3 24.9 5.06 72 46.6 23.3 4.75 44.0 22.5 5.02 41.4 21.6 5.27 39.0 21.0 5.55 67 42.6 30.7 4.63 40.0 29.8 4.88 37.4 28.8 5.12 34.9 27.8 5.35 62 38.2 36.8 4.48 36.0 35.4 4.71 33.9 33.8 4.96 31.9 31.9 5.21 63* 39.1 29.6 4.50 36.6 28.6 4.73 34.2 27.6 4.96 31.7 26.5 5.18 72 46.8 24.0 4.84 44.2 23.2 5.10 42.0 22.7 5.40 39.1 21.8 5.64 67 43.0 32.3 4.72 40.4 31.5 4.99 37.8 30.5 5.22 35.1 29.5 5.45 62 39.0 38.6 4.59 36.9 36.8 4.85 34.9 34.8 5.11 32.9 32.8 5.36 63* 39.7 31.2 4.59 37.0 30.2 4.84 34.5 29.2 5.07 32.0 28.1 5.29 655A048 (4 TONS) Indoor Air Cfm BF 1400 0.06 1600 0.07 1800 0.08 F Ewb Outdoor Air Temperature (F) 85 95 105 115 Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible Compressor kw 72 52.9 26.3 4.82 50.8 25.6 5.30 48.5 24.8 5.83 46.0 24.1 6.42 67 48.4 33.8 4.75 46.3 33.1 5.23 43.9 32.1 5.76 41.4 31.1 6.32 62 44.0 40.8 4.68 41.9 39.7 5.15 39.7 38.6 5.66 37.6 37.5 6.20 63* 44.9 32.8 4.70 42.7 31.8 5.18 40.5 30.9 5.68 38.2 29.9 6.22 72 53.9 27.6 4.94 51.7 26.9 5.43 49.2 26.1 5.96 46.7 25.3 6.54 67 49.3 36.1 4.86 47.0 35.2 5.34 44.5 34.3 5.87 41.9 33.3 6.44 62 44.9 43.6 4.79 42.8 42.4 5.27 40.9 40.9 5.79 38.9 38.9 6.35 63* 45.7 34.9 4.82 43.3 33.9 5.29 41.0 32.9 5.80 38.6 31.9 6.34 72 54.2 28.5 5.04 52.1 28.0 5.53 49.7 27.3 6.07 47.0 26.5 6.65 67 49.8 38.0 4.97 47.6 37.3 5.45 45.0 36.4 5.99 42.3 35.4 6.55 62 45.8 45.7 4.90 44.0 44.0 5.38 42.0 42.0 5.92 40.0 40.0 6.48 63* 46.2 36.9 4.93 43.8 35.9 5.40 41.5 34.9 5.91 39.0 33.8 6.46 BF Bypass Factor Ewb Entering Wet Bulb ldb Leaving Dry Bulb lwb Leaving Wet Bulb *At 75 F entering dry bulb (edb) (Tennessee Valley Authority [TVA] rating conditions); all others at 80 F. NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: tldb =tewb sensible capacity (MBtuh x 1000) 1.10 x cfm tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving indoor coil (hlwb) total capacity (MBtuh x 1000) hlwb=hewb 4.5 cfm Where: hewb = Enthalpy of air entering indoor coil 3. The sensible heat capacity is based on 80 F edb temperature of air entering indoor coil. Below 80 F edb, subtract (corr factor x cfm) from the sensible heat capacity. Above 80 F edb, add (corr factor x cfm) to the sensible heat capacity. Correction Factor = 1.10 x (1 BF) x (edb 80). 11
655A060 (5 TONS) Indoor Air Cfm BF 1750 0.03 2000 0.04 2250 0.04 F Ewb COOLING CAPACITIES (cont) Outdoor Air Temperature (F) 85 95 105 115 Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Compressor Capacity MBtuh Total Sensible kw Total Sensible kw Total Sensible kw Total Sensible Compressor kw 72 66.3 32.8 6.12 63.4 31.8 6.71 60.2 30.9 7.34 56.8 29.6 8.00 67 59.8 42.1 5.98 56.8 41.0 6.55 53.8 40.0 7.17 50.7 38.8 7.86 62 53.6 51.0 5.85 50.8 49.7 6.42 48.2 48.2 7.03 46.0 45.9 7.72 63* 55.3 40.8 5.87 52.3 39.6 6.45 49.5 38.4 7.06 46.6 37.2 7.72 72 67.3 34.5 6.27 64.2 33.5 6.86 60.9 32.4 7.48 57.5 31.3 8.17 67 60.6 45.0 6.12 57.5 44.0 6.68 54.4 42.8 7.31 51.1 41.7 7.99 62 54.7 54.4 5.99 52.4 52.3 6.56 49.9 49.8 7.21 47.5 47.5 7.90 63* 56.1 43.5 6.02 53.0 42.3 6.59 50.0 41.1 7.20 47.0 39.9 7.86 72 67.8 35.8 6.40 64.7 34.9 6.98 61.3 33.9 7.61 57.8 32.9 8.29 67 61.1 47.7 6.25 57.9 46.6 6.82 54.8 45.5 7.44 51.4 44.4 8.13 62 56.2 56.2 6.15 53.9 53.9 6.73 51.3 51.3 7.39 48.8 48.8 8.08 63* 56.6 46.1 6.15 53.4 44.9 6.73 50.3 43.6 7.34 47.2 42.4 8.00 BF Bypass Factor Ewb Entering Wet Bulb ldb Leaving Dry Bulb lwb Leaving Wet Bulb *At 75 F entering dry bulb (edb) (Tennessee Valley Authority [TVA] rating conditions); all others at 80 F. NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: tldb =tewb sensible capacity (MBtuh x 1000) 1.10 x cfm tlwb = Wet-bulb temperature corresponding to enthalpy of air leaving indoor coil (hlwb) total capacity (MBtuh x 1000) hlwb=hewb 4.5 cfm Where: hewb = Enthalpy of air entering indoor coil 3. The sensible heat capacity is based on 80 F edb temperature of air entering indoor coil. Below 80 F edb, subtract (corr factor x cfm) from the sensible heat capacity. Above 80 F edb, add (corr factor x cfm) to the sensible heat capacity. Correction Factor = 1.10 x (1 BF) x (edb 80). 655A018 (1 1 2 TONS) Outdoor Coil Air Temp (F db at 70% rh) HEATING CAPACITIES 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 525 675 60 22.5 21.5 20.5 22.5 21.5 20.5 1.83 1.90 1.96 23.2 22.4 21.3 23.2 22.4 21.3 1.80 1.88 1.95 50 19.0 18.1 17.2 19.0 18.1 17.2 1.75 1.82 1.87 19.7 18.9 17.9 19.7 18.9 17.9 1.75 1.82 1.88 47 18.0 17.1 16.2 18.0 17.1 16.2 1.73 1.79 1.85 18.7 17.8 16.9 18.7 17.8 16.9 1.73 1.80 1.86 40 15.9 15.0 14.2 15.2 14.4 13.6 1.68 1.74 1.79 16.5 15.7 14.8 15.8 15.0 14.2 1.69 1.75 1.81 30 12.8 12.1 11.4 11.2 10.6 10.0 1.61 1.66 1.70 13.3 12.6 11.9 11.7 11.0 10.4 1.63 1.68 1.73 20 10.3 9.7 9.0 9.3 8.7 8.1 1.55 1.59 1.62 10.7 10.1 9.4 9.7 9.1 8.4 1.58 1.62 1.66 17 9.6 8.9 8.2 8.7 8.1 7.5 1.53 1.57 1.59 10.0 9.3 8.6 9.1 8.5 7.9 1.57 1.60 1.64 10 7.8 7.2 6.6 7.4 6.8 6.2 1.49 1.52 1.54 8.2 7.5 6.9 7.7 7.1 6.5 1.53 1.56 1.59 0 5.3 4.8 4.1 5.3 4.8 4.1 1.43 1.45 1.45 5.6 5.0 4.4 5.6 5.0 4.4 1.48 1.50 1.51 10 2.8 2.3 1.7 2.8 2.3 1.7 1.37 1.38 1.37 3.0 2.4 1.9 3.0 2.4 1.9 1.43 1.44 1.44 655A018 (1 1 2 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 750 60 23.4 22.7 21.7 23.4 22.7 21.7 1.80 1.89 1.96 50 20.0 19.1 18.2 20.0 19.1 18.2 1.76 1.83 1.89 47 19.0 18.1 17.1 19.0 18.1 17.1 1.74 1.81 1.87 40 16.7 15.9 15.0 16.0 15.2 14.4 1.70 1.76 1.82 30 13.5 12.8 12.0 11.8 11.2 10.5 1.65 1.70 1.75 20 10.9 10.2 9.5 9.8 9.2 8.6 1.60 1.64 1.68 17 10.1 9.5 8.8 9.2 8.6 8.0 1.59 1.63 1.66 10 8.3 7.7 7.0 7.8 7.2 6.6 1.55 1.59 1.61 0 5.7 5.1 4.5 5.7 5.1 4.5 1.51 1.53 1.54 10 3.1 2.6 2.0 3.1 2.6 2.0 1.46 1.47 1.47 db Dry Bulb edb Entering Dry Bulb rh Relative Humidity NOTES: 1. heating capacity values shown include indoor-fan motor heat. These values ignore the effect of outdoor coil frost build-up. 2. heating capacity values shown are net values to which indoor-fan motor heat has been added and from which the defrost effect has been subtracted. To obtain total system heating capacities, add the heating capacity of the supplemental electric heaters to the integrated capacities. 3. Total power input values include the compressor, outdoor-fan motor, and indoor-fan motor. 12
HEATING CAPACITIES (cont) 655A024 (2 TONS) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 700 800 60 29.7 28.6 27.2 29.7 28.6 27.2 2.31 2.41 2.50 29.8 29.0 27.8 29.8 29.0 27.8 2.28 2.39 2.49 50 25.5 24.3 23.1 25.5 24.3 23.1 2.24 2.32 2.39 26.0 24.8 23.6 26.0 24.8 23.6 2.23 2.32 2.40 47 24.3 23.1 21.8 24.3 23.1 21.8 2.22 2.29 2.36 24.8 23.6 22.3 24.8 23.6 22.3 2.22 2.30 2.37 40 21.4 20.3 19.1 20.5 19.4 18.4 2.15 2.22 2.28 21.9 20.7 19.6 21.0 19.9 18.8 2.16 2.23 2.30 30 17.3 16.3 15.4 15.1 14.3 13.5 2.05 2.11 2.17 17.6 16.6 15.7 15.5 14.6 13.8 2.07 2.13 2.19 20 13.9 13.1 12.2 12.5 11.8 11.0 1.97 2.02 2.06 14.2 13.4 12.5 12.8 12.1 11.3 2.00 2.05 2.09 17 12.9 12.1 11.3 11.8 11.1 10.3 1.95 1.99 2.03 13.2 12.4 11.6 12.0 11.3 10.5 1.97 2.02 2.06 10 10.6 9.88 9.10 9.96 9.32 8.59 1.89 1.93 1.96 10.8 10.1 9.33 10.2 9.54 8.80 1.92 1.96 2.00 0 7.20 6.67 5.98 7.20 6.67 5.98 1.81 1.84 1.86 7.39 6.85 6.14 7.39 6.85 6.14 1.85 1.88 1.90-10 3.85 3.47 2.85 3.85 3.47 2.85 1.73 1.75 1.76 3.97 3.59 2.95 3.97 3.59 2.95 1.77 1.79 1.80 655A024 (2 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 900 60 30.2 29.3 28.2 30.2 29.3 28.2 2.27 2.38 2.48 50 26.4 25.3 24.0 26.4 25.3 24.0 2.24 2.33 2.41 47 25.3 24.0 22.8 25.3 24.0 22.8 2.23 2.31 2.38 40 22.3 21.1 20.0 21.3 20.3 19.2 2.17 2.25 2.31 30 18.0 17.0 16.0 15.7 14.9 14.0 2.09 2.15 2.21 20 14.5 13.6 12.8 13.1 12.3 11.5 2.02 2.07 2.12 17 13.4 12.6 11.8 12.2 11.5 10.7 2.00 2.05 2.09 10 11.0 10.3 9.53 10.4 9.72 8.99 1.95 1.99 2.03 0 7.52 6.97 6.29 7.52 6.97 6.29 1.88 1.92 1.94 10 4.04 3.65 3.06 4.04 3.65 3.06 1.82 1.84 1.85 655A030 (2 1 2 TONS) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 875 1000 60 38.2 36.6 34.9 38.2 36.6 34.9 2.95 3.09 3.22 38.8 37.3 35.8 38.8 37.3 35.8 2.91 3.07 3.21 50 32.0 30.6 29.0 32.0 30.6 29.0 2.79 2.92 3.03 32.6 31.2 29.7 32.6 31.2 29.7 2.78 2.92 3.03 47 30.1 28.8 27.3 30.1 28.8 27.3 2.75 2.87 2.98 30.8 29.4 27.9 30.8 29.4 27.9 2.74 2.87 2.98 40 26.3 25.1 23.8 25.3 24.1 22.8 2.64 2.76 2.86 26.9 25.7 24.3 25.8 24.6 23.4 2.64 2.76 2.87 30 20.9 19.9 18.8 18.3 17.4 16.5 2.49 2.59 2.68 21.3 20.3 19.2 18.7 17.8 16.8 2.50 2.61 2.70 20 16.7 15.9 14.9 15.1 14.3 13.4 2.37 2.46 2.53 17.0 16.2 15.3 15.4 14.6 13.8 2.39 2.48 2.56 17 15.5 14.7 13.8 14.1 13.4 12.5 2.33 2.41 2.49 15.8 15.0 14.1 14.4 13.7 12.8 2.35 2.44 2.52 10 12.6 11.9 11.0 11.9 11.2 10.4 2.24 2.32 2.38 12.8 12.1 11.3 12.1 11.5 10.7 2.27 2.35 2.41 0 8.4 7.9 7.1 8.4 7.9 7.1 2.11 2.18 2.23 8.6 8.1 7.4 8.6 8.1 7.4 2.15 2.22 2.27 10 4.3 3.9 3.3 4.3 3.9 3.3 1.99 2.04 2.08 4.3 4.0 3.4 4.3 4.0 3.4 2.03 2.09 2.13 655A030 (2 1 2 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 1125 60 39.3 37.9 36.5 39.3 37.9 36.5 2.90 3.06 3.20 50 33.1 31.8 30.3 33.1 31.8 30.3 2.78 2.92 3.04 47 31.3 30.0 28.5 31.3 30.0 28.5 2.74 2.88 2.99 40 27.3 26.1 24.8 26.2 25.1 23.8 2.65 2.78 2.88 30 21.6 20.6 19.6 19.0 18.1 17.2 2.52 2.63 2.73 20 17.3 16.5 15.6 15.6 14.9 14.0 2.41 2.51 2.59 17 16.0 15.3 14.4 14.6 13.9 13.1 2.38 2.47 2.55 10 13.0 12.4 11.6 12.3 11.7 10.9 2.30 2.38 2.45 0 8.7 8.2 7.6 8.7 8.2 7.6 2.19 2.26 2.31 10 4.4 4.1 3.6 4.4 4.1 3.6 2.08 2.13 2.17 db Dry Bulb edb Entering Dry Bulb rh Relative Humidity NOTES: 1. heating capacity values shown include indoor-fan motor heat. These values ignore the effect of outdoor coil frost build-up. 2. heating capacity values shown are net values to which indoor-fan motor heat has been added and from which the defrost effect has been subtracted. To obtain total system heating capacities, add the heating capacity of the supplemental electric heaters to the integrated capacities. 3. Total power input values include the compressor, outdoor-fan motor, and indoor-fan motor. 13
HEATING CAPACITIES (cont) 655A036 (3 TONS) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 1050 1300 60 44.9 43.6 41.7 44.9 43.6 41.7 3.41 3.58 3.71 46.2 44.8 43.2 46.2 44.8 43.2 3.40 3.56 3.71 50 37.9 36.4 34.6 37.9 36.4 34.6 3.25 3.38 3.49 39.2 37.6 35.8 39.2 37.6 35.8 3.26 3.39 3.51 47 35.8 34.2 32.5 35.8 34.2 32.5 3.20 3.32 3.42 37.1 35.4 33.6 37.1 35.4 33.6 3.22 3.34 3.45 40 31.3 29.7 28.1 30.0 28.5 27.0 3.08 3.18 3.27 32.3 30.8 29.1 31.0 29.5 28.0 3.12 3.22 3.31 30 24.7 23.3 21.9 21.6 20.4 19.2 2.90 2.98 3.05 25.5 24.1 22.7 22.4 21.1 19.9 2.96 3.04 3.11 20 19.5 18.3 16.9 17.6 16.5 15.2 2.75 2.81 2.86 20.2 19.0 17.6 18.2 17.1 15.8 2.82 2.88 2.93 17 17.9 16.8 15.4 16.4 15.3 14.0 2.70 2.76 2.80 18.6 17.4 16.0 17.0 15.9 14.6 2.78 2.83 2.88 10 14.3 13.2 11.9 13.5 12.5 11.2 2.60 2.64 2.67 14.9 13.8 12.5 14.0 13.0 11.8 2.68 2.72 2.76 0 9.1 8.2 6.8 9.1 8.2 6.8 2.44 2.47 2.47 9.5 8.6 7.3 9.5 8.6 7.3 2.55 2.57 2.58 10 3.9 3.2 1.8 3.9 3.2 1.8 2.29 2.29 2.28 4.2 3.4 2.2 4.2 3.4 2.2 2.41 2.41 2.40 655A036 (3 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 1500 60 46.8 45.4 43.8 46.8 45.4 43.8 3.41 3.56 3.72 50 39.9 38.3 36.6 39.9 38.3 36.6 3.29 3.42 3.54 47 37.8 36.1 34.4 37.8 36.1 34.4 3.26 3.38 3.49 40 33.0 31.4 29.8 31.6 30.2 28.6 3.16 3.26 3.36 30 26.1 24.7 23.2 22.9 21.6 20.4 3.01 3.10 3.17 20 20.6 19.4 18.0 18.6 17.5 16.3 2.88 2.95 3.00 17 19.0 17.8 16.5 17.3 16.3 15.0 2.84 2.90 2.95 10 15.2 14.1 12.9 14.4 13.4 12.2 2.75 2.80 2.83 0 9.8 8.9 7.8 9.8 8.9 7.8 2.62 2.65 2.66 10 4.3 3.6 2.5 4.3 3.6 2.5 2.49 2.50 2.49 655A042 (3 1 2 TONS) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 1225 1400 60 51.1 49.3 47.8 51.1 49.3 47.8 3.87 4.06 4.26 50.7 50.1 48.7 50.7 50.1 48.7 3.80 4.04 4.25 50 43.7 42.0 40.3 43.7 42.0 40.3 3.70 3.87 4.04 44.1 42.7 41.1 44.1 42.7 41.1 3.69 3.88 4.05 47 41.4 39.8 38.1 41.4 39.8 38.1 3.65 3.82 3.97 42.2 40.5 38.8 42.2 40.5 38.8 3.66 3.83 3.99 40 36.4 34.9 33.3 34.9 33.4 31.9 3.52 3.66 3.80 37.0 35.5 33.9 35.5 34.1 32.6 3.54 3.69 3.83 30 29.2 27.8 26.5 25.5 24.4 23.2 3.32 3.45 3.56 29.7 28.3 27.0 26.0 24.8 23.7 3.36 3.48 3.60 20 23.4 22.2 21.0 21.1 20.0 18.9 3.14 3.24 3.33 23.9 22.7 21.4 21.5 20.5 19.3 3.19 3.30 3.39 17 21.7 20.6 19.3 19.8 18.7 17.6 3.09 3.18 3.27 22.1 21.0 19.8 20.2 19.1 18.0 3.14 3.24 3.32 10 17.7 16.6 15.5 16.7 15.7 14.6 2.97 3.04 3.11 18.0 17.0 15.9 17.0 16.1 15.0 3.03 3.11 3.17 0 11.9 11.0 10.0 11.9 11.0 10.0 2.80 2.84 2.89 12.2 11.4 10.3 12.2 11.4 10.3 2.87 2.92 2.96 10 6.2 5.4 4.5 6.2 5.4 4.5 2.62 2.64 2.66 6.4 5.7 4.8 6.4 5.7 4.8 2.71 2.73 2.74 655A042 (3 1 2 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 1575 60 51.1 50.6 49.0 51.1 50.6 49.0 3.80 4.04 4.23 50 44.7 43.3 41.6 44.7 43.3 41.6 3.71 3.90 4.07 47 42.7 41.2 39.5 42.7 41.2 39.5 3.68 3.85 4.02 40 37.6 36.1 34.5 36.0 34.6 33.1 3.56 3.72 3.86 30 30.2 28.8 27.4 26.4 25.2 24.0 3.40 3.53 3.65 20 24.3 23.1 21.9 21.9 20.8 19.7 3.25 3.35 3.44 17 22.5 21.3 20.2 20.5 19.5 18.4 3.20 3.30 3.38 10 18.4 17.3 16.3 17.3 16.3 15.4 3.10 3.17 3.24 0 12.5 11.6 10.7 12.5 11.6 10.7 2.94 3.00 3.03 10 6.6 5.8 5.1 6.6 5.8 5.1 2.79 2.82 2.83 db Dry Bulb edb Entering Dry Bulb rh Relative Humidity NOTES: 1. heating capacity values shown include indoor-fan motor heat. These values ignore the effect of outdoor coil frost build-up. 2. heating capacity values shown are net values to which indoor-fan motor heat has been added and from which the defrost effect has been subtracted. To obtain total system heating capacities, add the heating capacity of the supplemental electric heaters to the integrated capacities. 3. Total power input values include the compressor, outdoor-fan motor, and indoor-fan motor. 14
HEATING CAPACITIES (cont) 655A048 (4 TONS) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 1400 1600 60 57.5 56.9 56.3 57.5 56.9 56.3 4.38 4.82 5.30 56.7 56.8 56.8 56.7 56.8 56.8 4.29 4.72 5.21 50 50.1 49.2 48.3 50.1 49.2 48.3 4.19 4.60 5.04 50.3 49.6 48.9 50.3 49.6 48.9 4.15 4.54 4.98 47 47.9 46.9 45.9 47.9 46.2 45.9 4.14 4.53 4.97 48.4 47.5 46.5 48.4 47.5 46.5 4.11 4.49 4.91 40 42.6 41.8 40.9 40.8 40.0 39.2 4.00 4.38 4.80 43.1 42.3 41.4 41.3 40.5 39.7 3.99 4.36 4.76 30 35.1 34.4 33.7 30.8 30.1 29.6 3.82 4.17 4.57 35.6 34.9 34.2 31.2 30.5 29.9 3.82 4.17 4.55 20 29.2 28.6 28.0 26.3 25.8 25.3 3.68 4.02 4.38 29.6 29.0 28.4 26.7 26.1 25.6 3.70 4.03 4.39 17 27.4 26.8 26.3 25.0 24.5 24.0 3.64 3.97 4.33 27.8 27.2 26.7 25.3 24.8 24.3 3.66 3.98 4.34 10 23.2 22.7 22.3 21.9 21.4 21.0 3.54 3.86 4.20 23.5 23.1 22.6 22.1 21.7 21.3 3.57 3.89 4.22 0 17.3 16.9 16.6 17.3 16.9 16.6 3.40 3.70 4.01 17.5 17.2 16.9 17.5 17.2 16.9 3.45 3.74 4.06 10 11.4 11.1 10.9 11.4 11.1 10.9 3.27 3.54 3.83 11.5 11.3 11.1 11.5 11.3 11.1 3.33 3.60 3.90 655A048 (4 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 1800 60 56.0 56.6 56.4 56.0 56.6 56.4 4.26 4.68 5.13 50 50.3 49.9 49.2 50.3 49.9 49.2 4.14 4.53 4.95 47 48.6 47.9 47.0 48.6 47.9 47.0 4.10 4.48 4.89 40 43.4 42.7 41.9 41.6 40.9 40.1 4.00 4.36 4.76 30 36.0 35.3 34.6 31.5 30.9 30.3 3.85 4.19 4.56 20 29.9 29.3 28.8 27.0 26.5 25.9 3.74 4.06 4.41 17 28.1 27.5 27.0 25.6 25.1 24.6 3.71 4.02 4.37 10 23.9 23.4 22.9 22.4 22.0 21.6 3.63 3.93 4.26 0 17.8 17.4 17.1 17.8 17.4 17.1 3.51 3.80 4.11 10 11.7 11.5 11.3 11.7 11.5 11.3 3.40 3.67 3.96 655A060 (5 TONS) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 60 70 80 1750 2000 60 70.1 69.0 67.9 70.1 69.0 67.9 5.09 5.58 6.12 70.7 69.6 67.9 70.7 69.6 6.00 5.03 5.49 6.00 50 60.4 59.2 58.1 60.4 59.2 58.1 4.88 5.34 5.85 61.2 59.9 58.1 61.2 59.9 5.77 4.85 5.28 5.77 47 57.6 56.3 55.2 57.6 56.3 55.2 4.82 5.27 5.77 58.3 57.0 55.2 58.3 57.0 5.70 4.79 5.22 5.70 40 51.1 50.0 49.0 48.9 47.9 47.0 4.68 5.11 5.60 51.7 50.6 49.0 49.5 48.5 5.55 4.67 5.08 5.55 30 41.8 40.9 40.3 36.6 35.9 35.3 4.48 4.89 5.36 42.3 41.4 40.3 37.0 36.3 5.34 4.49 4.89 5.34 20 34.4 33.7 32.8 31.0 30.4 29.6 4.32 4.72 5.14 34.9 34.2 32.8 31.4 30.8 5.15 4.35 4.74 5.15 17 32.2 31.5 30.5 29.3 28.8 27.9 4.28 4.67 5.07 32.6 32.0 30.5 29.8 29.2 5.09 4.31 4.69 5.09 10 27.0 26.5 25.3 25.4 24.9 23.9 4.17 4.55 4.92 27.4 26.9 25.3 25.8 25.3 4.96 4.21 4.58 4.96 0 19.6 19.3 17.9 19.6 19.3 17.9 4.01 4.37 4.69 20.0 19.7 17.9 20.0 19.7 4.77 4.08 4.43 4.77 10 12.2 12.1 10.4 12.2 12.1 10.4 3.86 4.20 4.47 12.6 12.4 10.4 12.6 12.4 4.58 3.94 4.28 4.58 655A060 (5 TONS) (cont) Outdoor Coil Air Temp (F db at 70% rh) 60 70 80 60 70 80 60 70 80 2250 60 70.8 69.9 68.8 70.8 69.9 68.8 5.00 5.45 5.94 50 61.7 60.5 59.3 61.7 60.5 59.3 4.85 5.27 5.74 47 58.9 57.6 56.5 58.9 57.6 56.5 4.80 5.21 5.68 40 52.3 51.1 50.1 50.1 49.0 48.0 4.68 5.09 5.55 30 42.8 41.9 41.1 37.5 36.7 36.0 4.52 4.91 5.35 20 35.3 34.6 33.7 31.8 31.2 30.4 4.39 4.77 5.18 17 33.0 32.4 31.5 30.1 29.5 28.7 4.36 4.73 5.13 10 27.8 27.2 26.3 26.2 25.6 24.8 4.27 4.63 5.01 0 20.3 19.9 18.9 20.3 19.9 18.9 4.14 4.50 4.84 10 12.9 12.6 11.5 12.9 12.6 11.5 4.02 4.36 4.67 db Dry Bulb edb Entering Dry Bulb rh Relative Humidity NOTES: 1. heating capacity values shown include indoor-fan motor heat. These values ignore the effect of outdoor coil frost build-up. 2. heating capacity values shown are net values to which indoor-fan motor heat has been added and from which the defrost effect has been subtracted. To obtain total system heating capacities, add the heating capacity of the supplemental electric heaters to the integrated capacities. 3. Total power input values include the compressor, outdoor-fan motor, and indoor-fan motor. 15
SIZE 018 024 030 036 042 048 060 MOTOR SPEED Low High Low Med High Low Med High Low Med High Low High Low High Low High DRY COIL AIR DELIVERY* HORIZONTAL DISCHARGE (Deduct 10% for 208 v) 230 AND 460 V HORIZONTAL DISCHARGE External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts 230 225 220 210 195 170 Cfm 760 745 725 695 640 540 Watts 270 235 200 Cfm 850 700 450 Watts 280 275 265 255 250 245 240 Cfm 820 810 755 700 660 600 560 Watts 365 360 350 345 340 330 320 310 300 Cfm 1025 1010 975 940 900 850 800 720 630 Watts 490 480 470 460 445 430 410 390 380 Cfm 1300 1255 1200 1150 1080 1005 915 790 620 Watts Cfm Watts 365 360 360 350 350 Cfm 1060 1020 980 935 880 Watts 490 485 475 460 450 430 Cfm 1270 1220 1170 1100 1020 920 Watts 520 495 474 458 495 425 Cfm 1375 1335 1290 1244 1200 1146 Watts 575 560 535 510 480 460 440 425 Cfm 1520 1490 1450 1440 1380 1300 1200 1080 Watts 650 614 575 540 510 480 Cfm 1560 1500 1380 1280 1170 1060 Watts 730 700 680 645 615 580 535 490 430 Cfm 1620 1590 1550 1510 1460 1390 1310 1210 1050 Watts 850 800 750 700 650 610 Cfm 1780 1670 1550 1400 1230 1050 Watts 1080 1040 1020 970 910 840 785 730 680 620 540 Cfm 2100 2090 2080 2060 1980 1900 1810 1710 1590 1450 1200 Watts 1230 1190 1125 1060 1010 940 880 820 760 710 660 Cfm 2390 2340 2280 2210 2150 2030 1900 1770 1630 1480 1300 Watts 1150 1100 1050 1010 950 900 850 800 730 650 Cfm 2500 2410 2330 2260 2170 2080 1990 1880 1750 1580 Watts 1170 1110 1050 990 920 880 Cfm 2470 2340 2200 2040 1870 1700 *Air delivery values are based on operating voltage of 230 v or 460 v, dry coil, without filter or electric heater. Deduct wet coil, filter, and electric heater pressure drops to obtain external static pressure available for ducting. NOTES: 1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Indoor coil frosting may occur at airflows below this point. 2. Dashes indicate portions of table that are beyond the blower motor capacity or are not recommended. 16
SIZE 018 024 030 036 042 048 060 MOTOR SPEED Low High Low Med High Low Med High Low Med High Low High Low High Low High DRY COIL AIR DELIVERY* VERTICAL DISCHARGE (Deduct 10% for 208 v) 230 AND 460 V VERTICAL DISCHARGE External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Watts 230 225 220 210 195 170 Cfm 760 745 725 695 640 540 Watts 270 235 200 Cfm 850 700 450 Watts 280 275 265 255 250 245 240 Cfm 820 810 755 700 660 600 560 Watts 365 360 350 345 340 330 320 310 300 Cfm 1025 1010 975 940 900 850 800 720 630 Watts 490 480 470 460 445 430 410 390 380 Cfm 1300 1255 1200 1150 1080 1005 915 790 620 Watts Cfm Watts 365 360 360 350 350 Cfm 1060 1020 980 935 880 Watts 490 485 475 460 450 430 Cfm 1270 1220 1170 1100 1020 920 Watts 520 495 474 458 495 425 Cfm 1375 1335 1290 1244 1200 1146 Watts 575 560 535 510 480 460 440 425 Cfm 1520 1490 1450 1440 1380 1300 1200 1080 Watts 650 614 575 540 510 480 Cfm 1560 1500 1380 1280 1170 1060 Watts 730 700 680 645 615 580 535 490 430 Cfm 1620 1590 1550 1510 1460 1390 1310 1210 1050 Watts 850 800 750 700 650 610 Cfm 1780 1670 1550 1400 1230 1050 Watts 1080 1040 1020 970 910 840 785 730 680 620 540 Cfm 2100 2090 2080 2060 1980 1900 1810 1710 1590 1450 1200 Watts 1230 1190 1125 1060 1010 940 880 820 760 710 660 Cfm 2390 2340 2280 2210 2150 2030 1900 1770 1630 1480 1300 Watts 890 850 810 780 740 710 660 630 580 Cfm 2500 2410 2330 2260 2170 2080 1970 1860 1700 Watts 1000 960 910 870 830 790 750 Cfm 2480 2370 2250 2120 2000 1850 1690 *Air delivery values are based on operating voltage of 230 v or 460 v, dry coil, without filter or electric heater. Deduct wet coil, filter, and electric heater pressure drops to obtain external static pressure available for ducting. NOTES: 1. Do not operate the unit at a cooling airflow that is less than 350 cfm for each 12,000 Btuh of rated cooling capacity. Indoor coil frosting may occur at airflows below this point. 2. Dashes indicate portions of table that are beyond the blower motor capacity or are not recommended. 17
SIZE FILTER SIZE (in.) WET COIL PRESSURE DROP SIZE AIRFLOW (cfm) PRESSURE DROP (in. wg) 600 0.069 018 700 0.082 800 0.102 900 0.116 600 0.039 024 700 0.058 800 0.075 900 0.088 900 0.088 030 1000 0.095 1200 0.123 1000 0.068 036 1200 0.088 1400 0.108 1600 0.123 1000 0.048 042 1200 0.069 1400 0.088 1600 0.102 1400 0.068 048 1600 0.075 1800 0.088 1700 0.082 060 1900 0.095 2100 0.108 2300 0.123 ACCESSORY ELECTRIC HEATER PRESSURE DROP (in. wg) HEATER kw CFM 600 800 1000 1200 1400 1600 1800 2000 2200 5-20 0.030 0.033 0.037 0.042 0.047 0.052 0.060 0.067 0.075 FILTER PRESSURE DROP (in. wg) CFM 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 018, 024 20 x 20 0.05 0.07 0.08 0.10 0.12 0.13 030 20 x 24 0.09 0.10 0.11 0.13 0.14 036, 042 24 x 24 0.08 0.09 0.10 0.11 0.12 0.14 0.15 048, 060 24 x 30 0.09 0.10 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 ACCESSORY ELECTRIC HEATER PACKAGE USAGE DUAL POINT POWER PACKAGES HEATER ACCESSORY KIT PART NUMBER SIZE 018 024 030 036 042 048 060 208/240-1-60* 5.0 kw 389081-701 X X X X X X X 7.5 kw 389082-701 X X X X X X X 10.0 kw 389083-701 X X X X X X X 15.0 kw 389215-701 X X X X X 17.5 kw 389085-701 X 20.0 kw 389086-701 X X X 208/240-3-60* 10.0 kw 389087-701 X X X X X 15.0 kw 389088-701 X X X X X 17.5 kw 389089-701 X X X X 480-3-60 10.0 kw 389090-701 X X X X 15.0 kw 389091-701 X X X X 17.5 kw 389092-701 X X X X *kw shown at 240 v. 18