Performance Rating of Unit Ventilators

Similar documents
Performance Rating of Heat Pump Pool Heaters

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

Performance Rating of Heat Pump Pool Heaters

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers

Performance Rating of Refrigerant Pressure Regulating Valves

Sound Performance Rating of Non-ducted Indoor Airconditioning

AHRI Standard 870 (I-P) Standard for Performance Rating of Direct Geoexchange Heat Pumps

AHRI Standard 751 (SI) 2016 Standard for Performance Rating of Thermostatic Refrigerant Expansion Valves

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Sound Performance Rating of Outdoor Unitary Equipment

Performance Rating of Automatic Commercial Ice-makers

Performance Rating of Computer and Data Processing Room Air Conditioners

Standard for 2006 Performance Rating Of Positive Displacement Ammonia Compressors and Compressor Units

Performance Rating of Active Chilled Beams

Specifications for Fluorocarbon Refrigerants

ANSI/AHRI Standard 1351 (SI) 2014 Standard for Mechanical Performance Rating of Central Station Air-handling Unit Casings

Specifications for Fluorocarbon Refrigerants

ANSI/AHRI Standard 1360 (I-P) 2016 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners

Performance Rating of Commercial and Industrial Humidifiers

AHRI Standard 1360 (I-P) 2017 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners

AHRI Guideline N with Addendum Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

1997 STANDARD for APPLICATION OF SOUND RATING LEVELS OF OUTDOOR UNITARY EQUIPMENT. Standard NORTH FAIRFAX DRIVE! ARLINGTON, VIRGINIA 22203

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

AHRI Guideline N Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

Specifications for Refrigerants

Specifications for Refrigerants

2015 Standard for Performance Rating of Refrigerant Recovery Equipment and Recovery/Recycling Equipment

2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)

Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

CHAPTER 5 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

ANSI/AHRI Standard Standard for Performance Rating of Indoor Pool Dehumidifiers

CHAPTER 6 REFERENCED STANDARDS. American Architectural Manufacturers Association 1827 Walden Office Square Suite 550 Schaumburg, IL

AHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers

CHAPTER 6 [CE] REFERENCED STANDARDS

WATER-SOURCE HEAT PUMPS CERTIFICATION PROGRAM For 50 Hz Products

AHRI Certification Program Scopes - COOLING

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

COMcheck Software Version Review Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ERRATA SHEET FOR ANSI/ASHRAE/IES STANDARD (I-P Edition) Energy Standard for Buildings Except Low-Rise Residential Buildings.

This document is a preview generated by EVS

COMcheck Software Version Mechanical Compliance Certificate

The products covered by the Regulation can be classified as follows:

2011 Manitoba Energy Code for Buildings (MECB) PART 5, Heating, Ventilating and Air-conditioning Systems

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

SECTION AIR-SOURCE UNITARY HEAT PUMPS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

INDOOR POOL DEHUMIDIFIERS CERTIFICATION PROGRAM

ASHRAE WILL GIVE YOU THE WORLD. This ASHRAE Distinguished Lecturer is brought to you by the Society Chapter Technology Transfer Committee

COMcheck Software Version Mechanical Compliance Certificate

Methods of Testing Capacity of Refrigerant Solenoid Valves

Certification Programs, Standards,

High Performance Building Guide 1

Applying VRF? Don t Overlook Standard 15

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Applying VRF? Don t Overlook Standard 15

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

ASHRAE Standard 62 Ventilation Report Technical Assignment #1. Calvert Memorial Hospital Prince Frederick, MD

Low GWP Refrigerants for Air Conditioning Applications

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

2009 IECC Commercial Mechanical Requirements

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

2016 Annual Conference

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Reviewing HVAC Designs for Compliance with ACCA Manual S

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

QW SERIES WALL SLEEVE (THROUGH WINDOW OPENING) INSTALLATION INSTRUCTIONS. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Application of the 2012 North Carolina Energy Conservation Code

Variable Refrigeration Flow Systems Overview 10/11/2016

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

AMCA Publication

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

2009 Washington State Non-Residential Energy Code Scott Rushing, PE, LEED AP - Rushing Company Lisa Rosenow, CSBA, LEED AP NEEC

UNIFIED FACILITIES GUIDE SPECIFICATIONS

INSTALLATION INSTRUCTIONS

HVAC Mandatory Provisions Part II, Page 1

SECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

City of Duluth Festival Center 04/25

Safety Standard for Refrigeration Systems

INTERNATIONAL STANDARD

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

COMcheck Software Version

Adding More Fan Power Can Be a Good Thing

R-410A DUCTLESS SPLIT SYSTEMS. Single Zone, Dual Zone & Multi Zone Air Conditioners and Heat Pumps

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Saudi Standards, Metrology and Quality Org.(SASO)

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

The Current (2017) State of the Art for Air Leakage in Ductwork

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Transcription:

AHRI Standard 840 (I-P) 1 2015 Standard for Performance Rating of Unit Ventilators Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Office Copyright 2009, by Air-Conditioning and Refrigeration Institute Registered United States Patent and Trademark

IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes AHRI Standard 840-98. See AHRI Standard 841 for SI ratings. AHRI CERTIFICATION PROGRAM PROVISIONS Scope of the Certification Program The certification program includes Unit Ventilators, as defined in Section 3, with outside air ventilation and return air dampers capable of providing ventilation air of at least 80% of rated standard airflow with the capability of providing any combination of these functions: humidity control, circulation, heating, cooling and filtering of air. Certified Ratings Refer to the Unit Ventilators Operations Manual for the certified ratings. Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Copyright 2015, by Air-Conditioning, Heating, and Refrigeration Institute Registered United States Patent and Trademark Office

TABLE OF CONTENTS SECTION PAGE Section 1. Purpose... 1 Section 2. Scope... 1 Section 3. Definitions... 1 Section 4. Classifications... 2 Section 5. Test Requirements... 3 Section 6. Rating Requirements... 3 Section 7. Minimum Data Requirements for Published Ratings... 4 Section 8. Operating Requirements... 5 Section 9. Marking and Nameplate Data... 6 Section 10. Conformance Conditions... 6 TABLES Table 1. Air Flow Testing Conditions... 4 Table 2. Standard Rating Conditions for Unit Ventilators... 5 FIGURES Figure 1. Standard Ventilation Rate Test Set-up... 3 APPENDICES Appendix A. References - Normative... 7 Appendix B. References - Informative... 8

PERFORMANCE RATING OF UNIT VENTILATORS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for Unit Ventilators: definitions; classifications; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data; and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, engineers, installers, contractors, and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to Unit Ventilators, defined in Section 3.6. 2.2 Exclusions. This standard does not apply to equipment as defined in the following standards: 2.2.1 This standard does not apply to room air-conditioners, which are covered in AHAM Standard RAC-1 and/or ANSI Standard Z234.1. 2.2.2 This standard does not apply to central-station air-handling units, which are covered in ANSI/AHRI Standard 430 (I-P). 2.2.3 This standard does not apply to variable refrigerant flow multi-split air conditioners and multi-split heat pumps, which are covered in ANSI/AHRI Standard 1230. Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Terminology website (https://www.ashrae.org/resources--publications/free-resources/ashrae-terminology) and in ANSI/AHRI Standard 210/240, ANSI/AHRI Standard 440, ANSI/AHRI/CSA Standard 310/380, ANSI/AHRI Standard 390, and ANSI/AHRI/ASHRAE/ISO Standard 13256-1. 3.1 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. As used herein, the term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated rating conditions. 3.1.1 Application Rating. A rating based on tests performed at application rating conditions (other than Standard Rating Conditions.) 3.1.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.2 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.2.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.2.2 Application Rating Conditions. Rating conditions that are not the standard rating conditions. 1

3.3 "Shall" or "Should". "Shall" or "should" shall be interpreted as follows: 3.3.1 Shall. Where "shall" or "shall not" is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.3.2 Should. "Should" is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.4 Standard Air. Air weighing 0.075 lb/ft 3 which approximates dry air at 70 F at a barometric pressure of 29.92 in Hg. 3.5 Standard Ventilation Rate. The outdoor airflow to be provided in the breathing zone to dilute contaminates generated by space occupants and contents of the building contaminates, cfm. 3.6 Unit Ventilator. A factory-made assembly, equipped with outside air ventilation and return air dampers capable of introducing ventilation air of at least 80% of rated air flow of Standard Air, while also having the capability to provide any combination of the following functions: humidity control, heating, cooling, and filtering of air. The source of humidity control, heating or cooling supplementary to that from ventilation air, may be remote or an integral part of the unit itself. This equipment is designed for free delivery of air into a room, but may be applied with minimal ductwork having a static resistance not exceeding 0.50 in H 2O. This equipment can be either vertical floor standing or horizontally mounted, in or adjacent to the space it serves. This equipment is provided with air capacities of 3000 cfm or less. 3.6.1 DX Fan-coil Unit Ventilators. Any equipment as defined in ANSI/AHRI Standard 210/240 with ventilation capabilities as defined in Section 3.6. 3.6.2 Hydronic Fan-coil Unit Ventilators. Any equipment as defined in ANSI/AHRI Standard 440 with ventilation capabilities as defined in Section 3.6. 3.6.3 Self-contained Unit Ventilators. Any equipment as defined in ANSI/AHRI/CSA Standard 310/380 with ventilation capabilities as defined in Section 3.6. 3.6.4 Single Package Vertical Unit Ventilators. Any equipment as defined in ANSI/AHRI Standard 390 with ventilation capabilities as defined in Section 3.6. 3.6.5 Water-source Self-contained Unit Ventilators. Any equipment as defined in ANSI/AHRI/ASHRAE/ISO Standard 13256-1 with ventilation capabilities as defined in Section 3.6. Section 4. Classifications 4.1 Methods of Classification. Unit ventilators shall be classified according to the following: 4.1.1 By Unit Type. 4.1.1 DX Fan-coil Unit Ventilators. 4.1.2 Hydronic Fan-coil Unit Ventilators. 4.1.3 Self-contained Unit Ventilators. 4.1.4 Single Package Vertical Unit Ventilators. 4.1.5 Water-source Self-contained Unit Ventilators. 2

Section 5. Test Requirements 5.1 Testing Requirements. All ratings shall be verified by tests conducted in accordance with ANSI/ASHRAE Standard 79. 5.1.1 Room Air Test. The room air test shall be conducted with the ventilation air inlet opening sealed so that no airflow enters the unit except from the room side. The airflow rate shall be the value measured from flowmeter 1 as depicted in Figure 1 and as indicated in Table 1. 5.1.2 Ventilation Air Test. The ventilation air test shall be conducted with an airflow rate measuring apparatus connected to the ventilation air opening. The airflow rate shall be the value measured from flowmeter 2 as depicted in Figure 1. Flowmeter 1 and any associated ductwork shall be removed for this test. Units shall be tested without any outside air intakes, louvers, wall boxes, etc. in place. The unit shall be tested with an external static of negative 0.05 in H 2O measured at the ventilation air inlet to simulate the pressure drop of a typical device and as indicated in Table 1. Figure 1. Standard Ventilation Rate Test Set-up 6.1 Standard Ratings. Section 6. Rating Requirements 6.1.1 Standard Performance Ratings. All applicable cooling capacity, heating capacity, power input, efficiency, standard airflow rate, fluid flow rate, and pressure drop ratings shall be verified by tests conducted at the Standard Rating Conditions, in accordance with the applicable standard(s) referenced in Sections 3.6.1, 3.6.2, 3.6.3, 3.6.4 and 3.6.5. 6.1.2 Standard Ventilation Rate. The Standard Ventilation Rate, expressed in percent, shall be determined in accordance with ANSI/ASHRAE Standard 79 by conducting two separate tests at the conditions specified in Table 1. References may also be made to ANSI/ASHRAE Standard 79 for a typical duct connection arrangement. 6.2 Electrical Conditions. All Standard Rating tests shall be performed at the nameplate rated voltage and frequency. For units with dual nameplate voltage ratings, standard rating tests shall be performed at both voltages, or at the lower of the two voltages, if only a single standard rating is to be published. 3

6.3 Equipment. Filters, any air-mixers, air-inlets, grilles, deflecting vanes, and any other regularly-furnished equipment shall be in place during all tests. Table 1. Air Flow Testing Conditions Room Air Test Ventilation Air Test Inlet Air Temperature 70 F to 80 F dry bulb 70 F to 80 F dry bulb Heating or cooling means Not in operation Not in operation Static Pressure difference between room air inlet and outlet 0.0 in H 2O Free discharge Static Pressure at ventilation air inlet Fan Speed Setting Inside /Outside Damper Position Face/Bypass Damper Position (if equipped) ANSI/ASHRAE Standard 41.2 Test Arrangements N/A Same as for standard cooling rating condition Adjusted for full room air (no ventilation air) Adjusted for full face, 0% bypass See Figure 14 of ANSI/ASHRAE Standard 41.2 Negative 0.05 in H 2O Same as for standard cooling rating condition Adjusted for full ventilation air (no room air) Adjusted for full face, 0% bypass See Figure 13 of ANSI/ASHRAE Standard 41.2 6.4 The Standard Ventilation Rate shall be the ratio of air flow rate measured in accordance with Section 5.4.2 divided by the air flow rate measured in accordance with Section 5.4.1 expressed as a percent. 6.5 Application Ratings. Ratings at conditions other than the Standard Rating Conditions may be published as application ratings, and shall be based on data determined by the methods of testing prescribed in the applicable standards referenced in Sections 3.6.1, 3.6.2, 3.6.3, 3.6.4 and 3.6.5. 6.6 Tolerances. To comply with this standard, published or reported cooling capacity, heating capacity, power input, efficiency, standard air flow rate, fluid flow rate, and pressure drop shall be based on data obtained in accordance with the provisions of this section, and shall be such that any production unit selected at random and tested in accordance with the standard shall achieve 100% of rated or published value, less the allowable tolerance specified in the applicable standard(s) referenced in 3 Sections 3.6.1, 3.6.2, 3.6.3, 3.6.4 and 3.6.5. The tested Standard Ventilation Rate shall be no less than 95% of the rated value and no less than 80% of the airflow rate measured in Section 6.4. Section 7. Minimum Data Requirements for Published Ratings 7.1 Published Ratings. Wherever application ratings are published or printed, they shall include or be accomplished by the Standard Rating clearly designated as such, including a statement of the conditions at which the ratings apply. All Published Ratings shall include the Standard Ventilation Rate, as well as the information required per product type as shown in Table 2. 4

Published Ratings Self-Contained Unit Ventilators Cooling Capacity Table 2. Standard Rating Conditions for Unit Ventilators Single Package Hydronic Fancoil Vertical Unit Unit Ventilator Ventilators Full load at Full load at standard standard Full load at standard DX Fan-coil Unit Ventilators Full load at high Water-source Self-contained Unit Ventilators Full load at standard and part load at low Cooling Efficiency Part load IPLV Part load IPLV N/A N/A N/A Heating Capacity Full load at standard N/A Full load at high Full load at standard Full load at standard and part load at low Heating Efficiency Full load COP Full load COP N/A Full load and part load HSPF Full load and part load COP Sensible Cooling N/A N/A Applicable N/A N/A Capacity Standard Applicable Applicable Applicable Applicable Applicable Ventilation Rate Power Input N/A N/A Applicable N/A N/A 7.1.1 Cooling Capacity, Btu/h 7.1.2 Heating Capacity, if applicable, Btu/h 7.1.3 Heating Coefficient of Performance (COP), if applicable 7.1.4 Part Load Rating (IPLV), kw 7.1.5 Region IV Heating Seasonal Performance Factor, HSPF, Minimum Design Heating Requirement, if applicable 7.1.6 Power Input, W 7.1.7 Standard Ventilation Rate, cfm Section 8. Operating Requirements 8.1 Performance Requirements. To comply with this standard, unit ventilators shall be designed and produced so as to perform in accordance with the provisions of this section, in such a manner that any production unit will meet the requirements detailed herein. 8.1.1 Self-contained Unit Ventilators. All performance tests for Self-contained Unit Ventilators shall be tested in accordance with the provisions of ANSI/AHRI/CSA Standard 310/380. 8.1.2 Single Package Vertical Unit Ventilator. All performance tests for Single Package Vertical Unit Ventilator shall be tested in accordance with the provisions of ANSI/AHRI Standard 390. 8.1.3 Water-source Self-contained Unit Ventilators. All performance tests for Water-source Self-contained Unit Ventilators shall be tested in accordance with the provisions of ANSI/AHRI/ASHRAE/ISO Standard 13256-1. 8.1.4 Hydronic Fan-coil Unit Ventilators. All performance tests for Hydronic Fan-coil Unit Ventilators shall be tested in accordance with the provisions of ANSI/AHRI Standard 440. 5

8.1.5 DX Fan-coil Unit Ventilators. All performance tests for DX Fan-coil Unit Ventilators shall be tested in accordance with the provisions of ANSI/AHRI Standards 210/240. Section 9. Marking and Nameplate Data 9.1 Marking and Nameplate Data. The unit nameplate shall display, as a minimum: 9.1.1 The name of the manufacturer and/or the supplier responsible for the performance ratings. 9.1.2 The model number of the equipment. 9.2 If the nameplate shows electrical characteristics, then nameplate voltages for 60 Hz systems shall include one or more of the equipment nameplate voltage ratings shown in Table 1 of ANSI/AHRI Standard 110. Nameplate voltages for 50 Hz systems shall include one or more of the utilization voltages shown in Table 1 of IEC Standard 60038. Section 10. Conformance Conditions 10.1 Conformance. While conformance with this standard is voluntary, conformance shall not be claimed or implied for products or equipment within the standard's Purpose (Section 1) and Scope (Section 2) unless such product claims meet all of the requirements of the standard and all of the testing and rating requirements are measured and reported in complete compliance with the standard. Any product that has not met all the requirements of the standard cannot reference, state, or acknowledge conformance to the standard in any written, oral, or electronic communication. 6 APPENDIX A. REFERENCES - NORMATIVE

A1 Listed here are all standards, handbooks and other publications essential to the formation and implementation of the standards. All references in this appendix are considered as part of the standard. A1.1 AHAM RAC-1, Room Air Conditioners, 2014, Association of Home Appliance Manufacturers, 1111 19th Street, NW, Suite 402 Washington, DC 20036, U.S.A. A1.2 ANSI Standard Z234.1, Room Air Conditioners, 1972, American National Standards Institute, 11 West 42nd Street, New York, NY 10036 U.S.A. A1.3 ANSI/AHRI Standard 110-2012, Air Conditioning, Heating, and Refrigerating Equipment Nameplate Voltages, 2012, American National Standards Institute/Air-Conditioning, Heating, and Refrigeration Institute, 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A. A1.4 ANSI/AHRI Standard 210/240-2008 with Addenda 1 and 2, Unitary Air-Conditioning and Air-Source Heat Pump Equipment, 2012, American National Standards Institute/Air-Conditioning, Heating, and Refrigeration Institute, 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A. A1.5 ANSI/AHRI Standard 390, Performance Rating of Single Package Vertical Air-Conditioners and Heat Pumps, 2003, American National Standards Institute/Air-Conditioning, Heating and Refrigeration Institute, / 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A./178 Rexdale Boulevard, Etobicoke, Ontario, M9W 1R3, Canada. A1.6 ANSI/AHRI Standard 430 (I-P)-2014, Performance Rating of Central Station Air-handling Unit Supply Fans, 2014, American National Standards Institute /Air-Conditioning, Heating, and Refrigeration Institute, 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A. A1.7 ANSI/AHRI Standard 440-2008 with Addendum 1, Performance Rating of Room Fan-coils, 2008, American National Standards Institute /Air-Conditioning, Heating, and Refrigeration Institute, 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A. A1.8 ANSI/AHRI Standard 1230-2010 with Addendum 2, Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment, 2010, American National Standards Institute /Air- Conditioning, Heating, and Refrigeration Institute, 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A. A1.9 ANSI/AHRI/ASHRAE/ISO Standard 13256-1-2012, Water-to-Air and Brine-to-Air Heat Pumps Testing and Rating for Performance, 2012, International Organization for Standardization, Case postale 56, CH-1211 Geneva 21, Switzerland. A1.10 ANSI/AHRI/CSA Standard 310/380/CSA-C744-14 Packaged Terminal Air-Conditioners and Heat Pumps, 2014, American National Standards Institute/Air-Conditioning, Heating and Refrigeration Institute, /Canadian Standards Association, 11 West 42nd Street, New York, NY 10036 U.S.A./2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A./178 Rexdale Boulevard, Etobicoke, Ontario, M9W 1R3, Canada. A1.11 ANSI/ASHRAE 41.2-1992, Standard Methods for Laboratory Airflow Measurement,1992, American National Standards Institute/American Society of Heating, Refrigeration, and Air-Conditioning Engineers, Inc., 11 West 42nd Street, New York, NY 10036 U.S.A./1791 Tullie Circle, N.E., Atlanta, Georgia, 30329, U.S.A. A1.12 ANSI/ASHRAE 79-2015, Methods for Rating Room Fan-coil Air Conditioners, 2015, American National Standards Institute/American Society of Heating, Refrigeration, and Air-Conditioning Engineers, Inc., 11 West 42nd Street, New York, NY 10036 U.S.A./1791 Tullie Circle, N.E., Atlanta, Georgia, 30329, U.S.A. A1.13 ASHRAE Terminology website (https://www.ashrae.org/resources--publications/free-resources/ashraeterminology), 2015, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc., 1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.14 IEC Standard 60038, IEC Standard Voltages, 2002, International Electrotechnical Commission, 3, rue de 7

Varembe, P.O. Box 131, 1211 Geneva 20, Switzerland. APPENDIX B. REFERENCES INFORMATIVE B1 Listed here are standards, handbooks and other publications which may provide useful information and background but are not considered essential. References in this appendix are not considered part of the standard. None. 8