Apartment Fire & Safety Inspection. City of Guadalupe

Similar documents
Business Fire Inspection. City of Guadalupe

8004 S El Dorado St., French Camp February 11, 2010 Posted Substandard/404B

Rental Housing Inspection Guide

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

Rental Registration & Safety Inspection Program: Inspection Checklist

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

General Room Standards. Room Electrical Requirements

Denver Fire Department Fire Prevention Division

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Osceola County Department of Fire Rescue and Emergency Medical Services

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Lighthouse. Prepare for your LHA inspection. Inspection Guide

Residential-based Care Facility R-4 Guideline

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

Clackamas Fire District #1 Self Inspection Program. Oregon Fire Code (OFC)

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

Residential Based Care Facility Guidelines

C i t y o f G r o v e r B e a c h ADMINISTRATIVE SERVICES DEPARTMENT

Business License Pre-inspection Checklist

School Fire Safety Checklist

Building Self-Inspection Program

For additional information regarding R-3.1 residential care facilities please contact (951)

THE TOWNSHIP OF CRANBURY

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Certificate of Inspection CHECKLIST

Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA

Large Family Daycare Guideline

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Family Foster Home Fire Safety Evaluation Checklist Instructions

Fire Safety Education in Multi- Unit Residential Buildings

Building and Grounds Self-Inspection Program

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

* Not all chapters have significant changes covered in this handout.

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Fire and Life Safety Review Form

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

El 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST

BUILDING DIVISION. Multi-family Rental Inspection Program SELF-CERTIFICATION APPLICATION

Short-Term & Accessory Short-Term Rental Safety Certification

Habitability Guidelines

Housing and Fire Safety Tips for Your Home & Property. Micki Jones, SFFD Rosemary Bosque, DBI May 6, 2015, SF Main Library

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Tarrant County Community Development Division

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

SECTION 915 CARBON MONOXIDE DETECTION

FIRE PREVENTION STANDARDS

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

South Davis Metro Fire Agency

Educational Occupancies

MOVE-IN / MOVE-OUT CONDITION

Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification

Agency for Health Care Administration

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

Operations Maintenance and Evaluations

RENTAL INSPECTION CHECKLIST

Montgomery County Land Bank PRE SALE INSPECTION REPORT

APPLICATION FOR Large Family Day Care Permit

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST

APPLICATION CERTIFICATE OF OCCUPANCY $50.00 FEE (non-refundable)

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

HOME REHABILITATION LOAN PROGRAM MINIMUM PROPERTY STANDARDS

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

City of Madison Heights Landlord Licensing Program 300 W. Thirteen Mile Road Madison Heights, MI (248)

Outdoor Festival and Special Event Guidelines

Agency for Health Care Administration

From Your Building Inspector

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

OCFEC Fire Marshal Summary Report

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

GENERAL GROUNDS. Inspector Name: Inspector Signature:

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

CHAPTER 7 ALTERATIONS LEVEL

REQUIREMENTS & GUIDELINES

Level I Chapter 1 Worksheet

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Maintaining Your Rental Property Part 2. An Overview of the Local Laws that Apply to Rental Properties. Please Sign In

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

DISASTER PREVENTION & SAFETY CHECKLIST

Informational Bulletin

Washoe County Department of Social Services

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Prevention. Education

Fire/General Safety Review Program Key Performance Indicators Environmental Health and Safety

Transcription:

Apartment Fire & Safety Inspection City of Guadalupe

Intent Provide information and the most common violation. It is NOT the intent to Identify all hazards a building may experience. It is NOT intended to limit the scope of the Fire Department. This Is Intended as General Information Only

Owner/occupant responsibility (CFC 109.2) Correction and abatement of violations of this code shall be the responsibility of the owner or the owner s authorized agent. Exception: Where an occupant creates, or allows to be created, hazardous conditions in violation of this code, the occupant shall be held responsible for the abatement of such hazardous conditions.

Access and Premises CFC 506.1, GMC 15.08.020 (506.1) Knox Box Accessible, visible, and operable. Access keys current. Electric perimeter vehicle access gates equipped with working Knox box switches. Manual (non-electric) perimeter vehicle access gates equipped with Knox padlock.

Access and Premises GMC 15.08.020, CFC 509.1.1, CFC 605.3.1, CFC 504.2 Address of Buildings Clearly visible and legible from street or road fronting property. Rear Door Address Numbers. Labeling (Electrical room, Fire Riser, Etc) Rooms, suites, and units properly identified and clearly marked. 4713 A 4713 B 4713 C 4713 D

Access and Premises CFC 509 Hydrants, Fire Dept. Connection, Post Indicator Valve. Visible, accessible, and operable. 3 ft. clearance required around all hydrants. FDC (Fire Dept. Sprinkler Connection) and PIV (Post Indicator Valve) labeled to the building which they are connected.

Flammable Liquids Storage CFC 5704 Flammable Liquid Storage Flammable and combustible liquid shall be stored in an approved flammable liquids containers and cabinets. Must not exceed 5 Gallons inside building or 10 Gallons outside

Fire Protection System CFC 315, CFC 901-905 Automatic Fire Sprinkler System Proof and documentation of yearly maintenance and 5 Year Service Certification. Serviced and maintained in operating condition. (e.g. annually) Water controls valves are locked in the open position and unobstructed.

Fire Protection System CFC Chapter 9 Fire Alarm System Proof and documentation of annual inspection, testing, and maintenance service of fire alarm system by qualified fire alarm testing company per NFPA 72.

Exits CFC 315, CFC 1017.5, CFC 1009, CFC 1008, CFC 1029 Storage under stairwell Not allowed Storage obstructing Aisle, Exits, and Corridors Not allowed. Exit path width 36 inch minimum.

Exits CFC 1029, CFC 1008 Repair broken doors Sleeping Area window bars permitted if in compliance CFC (operable from inside without special knowleded or key)

Exits CFC 1011 Emergency Lighting and Exit Signage Illuminated sign with Back up power supply. Maintained and operable. *For units with a common exit hallway*

Portable Fire Extinguishers CFC 906 Portable Fire Extinguisher Accessible and unobstructed. Visible with appropriate signage. Minimal Size P.F.E. All fire extinguishers must have a rating of at LEAST 2A:10BC. Travel Distance to an Extinguisher Maximum travel distance from anywhere must be NO more than 75 ft.

Portable Fire Extinguishers (Cont.) CFC 906 Mounting Exterior and hallway location Shall be installed so that the top of extinguisher is less than 5 ft. above the floor. Mandated by code Multi-family dwelling *Only Recommended for Single family dwellings*

Portable Fire Extinguishers (Cont.) CFC 906 Service and Tag The Extinguisher must have a tag which certifies that the extinguisher was last inspected and serviced within the past year. Fire extinguishers must be serviced on an annual basis.

Electrical CFC 605 Extension Cords Shall not be used as substitute for permanent wiring. No daisy chaining. Extension cords shall not be affixed to structures; extend through walls, ceilings, floors, under doors or floor coverings; or be subject to environmental or physical damage.

Electrical CFC 605 Surge Suppressor / Power Strips Approved UL listed surge suppressor with over-current protection may be used. Shall be directly connected to permanently installed receptacle. No daisy chaining. NOT ALLOWED

Electrical CFC 605 Multi-plug Adapters NOT ALLOWED Have additional electrical outlets installed by a certified licensed electrician if required to energize permanent appliances.

Electrical CFC 605 Electrical Panels and Electrical Rooms 30 inches of clearance from electrical panels. NO YES

Electrical CFC 605 Electrical Outlets, Switches, and Junction Boxes Ensure equipped with proper cover. Missing or damaged covers must be replaced. Open circuit breaker slots must be filled with approved filler plates.

Storage and Housekeeping CFC 315, CFC 901 Required Minimum Clearance from Storage to Ceiling 18 inches between deflector and top of storage in sprinklered buildings.

Storage and Housekeeping CFC 315, CFC 605, CPC 507 Trash Removal Remove rubbish and waste materials from building on daily basis. Storage Not Permitted Storage of Combustible materials shall be at least 30 Inches away Water heaters Heat producing appliances (heater, furnaces, Etc)

Fire Resistive Construction CFC 316, CFC 703 Holes in Ceiling and Walls of Fire Resistive Construction Holes in walls may be caused accidentally by individuals. Repair these holes immediately to restore the fire resistive properties of the wall.

Smoke Detectors HSC 13113.7 Placement Every floor level Every Bedroom Outside of every sleeping area. If a smoke barrier/curtain exists Smoke alarm must be added in the common area.

Smoke Detectors HSC 13113.7 Installation / Mounting Ceiling mount 4 below top of Ceiling 4 away from all walls 3 feet away from ceiling fans or Air/heating registers Walls mount No lower that 12 below ceiling. No closer that 4 from Ceiling. 3 feet away from Air/heating registers, Windows, or draft areas.

Smoke Detectors SB 745 Requirements Starting July 1, 2014. any smoke alarm installed that is solely battery powered MUST contain a non-removable battery that is rated to last 10 years. As of January 1, 2014 landlords cannot make the tenant responsible for testing or maintaining the smoke alarms. It is the landlords responsibility. On July 1, 2015 (10 year or older) ALL old smoke detectors that are solely powered by batteries must be replaced with those that contain a sealed battery that is rated to last 10 years.

Carbon Monoxide Detectors HSC 13263, HSC 17926 Placement Every floor level Outside Every Bedroom Outside of every sleeping area. Installation / Mounting 5 feet away from CO sources. (Furnace, Water heater, Fireplace, kitchen stove, Etc) 5 At least feet of the ground (Recommended)

Carbon Monoxide Detectors HSC 17926 An owner of a dwelling unit intended for human occupancy shall install and maintain carbon monoxide devices. The carbon monoxide device shall be operable at the time that the tenant takes possession. The owner or owner s agent shall correct any reported deficiencies or inoperabilities.

Substandard Buildings HSC 13263, HSC 17926 Any building or portion thereof including any dwelling unit shall be deemed and hereby is declared to be a substandard building: Inadequate sanitation shall include, but not be limited to, the following: Lack of, or improper water closet, lavatory, or bathtub or shower in a dwelling unit. Lack of, or improper kitchen sink. Lack of hot and cold running water to plumbing fixtures Lack of adequate heating. Lack of, or improper operation of required ventilating equipment. Room and space dimensions less than required by this code. Lack of required electrical lighting.

Substandard Buildings (Cont.) HSC 17920 Inadequate sanitation shall include, but not be limited to, the following: Dampness of habitable rooms. Infestation of insects, vermin, or rodents. Visible mold growth General dilapidation or improper maintenance. Lack of connection to required sewage disposal system. Lack of adequate garbage and rubbish storage and removal facilities.

Substandard Buildings (Cont.) HSC 17920 Structural hazards shall include, but not be limited to, the following: Deteriorated or inadequate foundations. Defective or deteriorated flooring or floor supports. Members of walls, partitions, or other vertical supports that split, lean, list, or buckle due to defective material or deterioration. Members of ceilings, roofs, ceiling and roof supports, or other horizontal members which sag, split, or buckle due to defective material or deterioration. Fireplaces or chimneys which list, bulge, or settle due to defective material or deterioration.

Substandard Buildings (Cont.) HSC 17920 Faulty weather protection, which shall include, but not be limited to, the following: Deteriorated, crumbling, or loose plaster. Deteriorated or ineffective waterproofing of exterior walls, roofs, foundations, or floors, including broken windows or doors. Defective or lack of weather protection for exterior wall coverings, including lack of paint or other approved protective covering. Broken, rotted, split, or buckled exterior wall coverings or roof coverings.

Substandard Buildings (Cont.) HSC 17920 Premises on which conditions constitute fire, health, or safety hazards. Any building or portion thereof that is determined to be an unsafe based on the latest edition of the Building Code. All buildings or portions thereof not provided with adequate exit facilities as required by code. All buildings or portions thereof occupied for living, sleeping, cooking, or dining purposes that were not designed or intended for that purpose.

Uninhabitable Structures Amy building or structure deemed Substandard by health and safety codes shall be deemed as Uninhabitable and unsafe for human occupation.