HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Similar documents
HS Dryer. Smart Solutions for Drying Compressed Air. Single Tower Heat Reactivated Desiccant Air Dryer. Engineered Air Products

Single Tower Heat Reactivated Desiccant Air Dryer

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Dual Tower Heat Reactivated Desiccant Air Dryer

Heatless Air Dryers AIRTEK PREMIUM PRODUCTS FOR INDUSTRY. TW Series

TWP & TWB Series Externally Heated and Blower Purge Desiccant Air Dryers

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

DGH Series Global Air Treatment

HEATLESS DESICCANT AIR DRYERS

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

Externally Heated Desiccant Air Dryer RP Series

CDT Series MCGUIRE AIR COMPRESSORS INC MCGUIRE AIR COMPRESSORS INC Heatless Desiccant Air Dryers 40 5,400 SCfm

Regenerative Desiccant Dryers. KAD, KED, KBD and Hybritec Series

Overview of HL series heatless regenerative dryers.

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

CLEAN, DRY COMPRESSED AIR

Refrigerated & Desiccant Compressed Air Dryer Product Selector

Quality Components as a basis for Quality Equipment

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

CDH Series Heatless Desiccant Dryers CFM

Heat Les Desiccant Compressed Air Dryers. DSE Series DSS Series DHD Series

Pressure Swing Desiccant Dryers

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Laboratory Enclosed Rotary Screw Air Compressor System with Air Treatment Center Package

DTA Series Heatless Adsorption Dryers ENGINEERING YOUR SUCCESS.

Externally Heated Exhaust Purge Regenerative Compressed Air Dryer

Blower Purge Desiccant Compressed Air Dryers IBP SERIES 500-4,300 SCFM

Hybrid Refrigerated/Desiccant Compressed Air Dryers

Unique, Energy-Saving Models HC & SP World Leader in Regenerative Dryer Technology

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

HEATLESS REGENERATIVE DRYERS

EXTERNALLY HEATED DESICCANT AIR DRYERS. DHP Series

White paper Compressed air drying

Heatless Desiccant Air Dryers. HHS SERIES, HHL SERIES AND HHE SERIES 40 to 5400 scfm (68 to 9175 nm 3 /h)

SULLAIR DESICCANT DRYERS

DESICCANT AIR DRYERS. BD + CD + CD series

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

clean, dry compressed air

Blower Purge Desiccant Compressed Air Dryer. HBP SERIES 500-4,300 SCFM ( nm 3 /h)

Heated purge desiccant compressed air dryers. hpd Series

Equipment Designed for Industrial Applications

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

DHW Series INSTRUCTION MANUAL. Pressure Swing Desiccant Compressed Air Dryer Models 7 through 50 scfm

Heatless Regenerative Air Dryers

DESICCANT AIR DRYERS. BD + CD + CD series

DHA Series Externally Heated & DBA Series Blower Purge Adsorption Dryers

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

MR Series Heatless Mini Regenerative Desiccant Dryer. Operator s Manual

Desiccant Air Dryers. Heatless, Heated and Heated Blower


CAMAIR THE LEADER IN DRY AIR TECHNOLOGY

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

industry revolves around VDWM Wall Mount Desiccant Dryer 7 50 SCFM

Blower Purge Desiccant Dryers. CAB SERIES 1,238-12,915 scfm

Benefits of Desiccant Dryer Dew Point & Purge Control

H & HC Heat-Of-Compression Air Dryers

Regenerative Desiccant Dryers. KAD, KED, KBD, and Hybritec Series. kaeser.com

TURBO DryPak Centrifugal Compressor and Heat-of-Compression Dryer

Desiccant Regenerative Dryers 3-10,000 scfm

HEATLESS REGENERATIVE COMPRESSED AIR DRYER models THL-200 through THL- 5000

CDWM Series Wall Mount Desiccant Dryer 7 50 SCFM

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls Rev. 06/27/14

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

REFRIGERATED AIR DRYERS

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

Laboratory Open Scroll Air Compressor System with Premium NFPA Controls

Compressed Air Dryers

A Primer for Air Dryer Selection

EXTERNALLY HEATED BLOWER PURGE DESICCANT AIR DRYERS. GBPD Series

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

NGV Fueling Station Dryers. FSD-A, FSD-T, FSD-M and MRS Series Catalog

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

Adsorption Compressed Air Dryer Heatless or heater regeneration

EXTERNALLY HEATED DESICCANT AIR DRYERS. GEHD Series

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Meeting Your Compressed Air Treatment Needs

TWP & TWB Series. Heat Reactivated Desiccant Dryers

ECLIPSE DESICCANT DRYERS ZHA HEATED PURGE MODELS

HEAT OF COMPRESSION DESICCANT AIR DRYERS. DHC Series

CHC Series High Capacity Refrigerated Dryer 2,000 20,000 SCFM

20 21,250 SCFM GLOBAL AIR TREATMENT. FIL Series

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

SECTION AIR COMPRESSORS AND ACCESSORIES

Refrigerated Air Dryers

Product Catalogue Edition 1

EN Installation and Operation Manual

Installation, Operation, and Maintenance Instructions. Heatless Regenerative Air Dryers and HLD-PAK Dryer/Filter Packages HLD-25 through HLD-6250

Industrial Oxygen Generation Plant

CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

PET Drying Technology

Heated Purge Desiccant Compressed Air Dryers. HPD Series

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Transcription:

Smart Solutions for Drying Compressed Air Single Tower Heat Reactivated Desiccant Air Dryer TM HS Dryer 800.943.794 www.engineeredairproducts.com Engineered Air Products

Understanding Compressed Air Moisture in compressed air is damaging. Using untreated air results in water and contaminants in your air lines, costly shut-downs and poor quality product. Until now, the solution was simple: take a risk and implement refrigeration technology, and live with poor air quality and high maintenance, but preserve the bottom line; or pay for high quality air from a desiccant adsorption drying system, and and watch the bottom line grow. HS Turbo Dryer is a desiccant air drying system specifically designed for - shift operations and provides air quality consistent with adsorption technology, yet costs less to operate than a refrigerated dryer. With only two moving parts and rugged construction, Turbo s simplicity will impress, and perform beyond your expectations. Turbo lets you focus on your process, not the utility that drives it... HS Turbo Heat Reactivated Dryer EAP Turbo heat reactivated desiccant air dryers use the adsorption method to remove moisture from compressed air. Pressure dew points as low as -40 0 F/C are achieved by directing the flow of saturated compressed air over a bed of desiccant. The most commonly used desiccant is activated alumina, a spherically shaped, hygroscopic material, selected for its consistent size, shape and extreme surface to mass ratio. This physically tough and chemically inert material is contained in an ASME (00 SCFM & larger) pressure vessel. As the saturated compressed air flows through the adsorbtion tower, its moisture content adheres to the surface of the desiccant. The dry compressed air is then discharged from the vessel into the distribution system. A master controller puts the unit into the regeneration mode once a day at the users selected time. Regeneration, sometimes referred to as purging, is the process of stripping the accumulated moisture from the desiccant bed. EAP Turbo heat reactivated dryers combine heat with forced ambient air to affect regeneration. Regeneration requires no compressed air or heat of compression and is self contained. As heated, low pressure, purge air flows gently through the regenerating bed, it desorbs the moisture that had accumulated on the surface of the desiccant during the drying cycle and exhausts it to the atmosphere.

Drying Mode During operations, Turbo has no moving parts and chances of shutdown are eliminated. 3 Compressed air enters the dryer through a pre-coalescing filter where 99.9% of liquid oil, moisture and particles are removed. Next the compressed air flows over the desiccant where water vapor is separated resulting in dew points as low as -40 0 F/C. A final filter polishes the air and removes any desiccant and particle fines before delivering clean, dry air. Regeneration Mode Turbo regenerates during off peak hours when energy costs are lowest. 3 The HS Turbo exclusive digital controller will automatically start the regeneration cycle at the selected time. The 3-way positioning valve slowly opens to depressurize the desiccant tank allowing regeneration air to escape through and exhaust muffler. The heater and blower provide a steady stream of heated, low pressure air that gently desorbs the accumulated moisture from the desiccant material. Upon completion, the system is cooled and repressurized, returning to the drying position.

All Turbo Dryers are equipped with Allen Bradley Digital Programmable Controls that provide simple, reliable, and intelligent capabilities. HS Turbo Logic Pro Controller Four line interactive backlit display Cycle time adjustments and real time clock Cycle stepping, cycle reset and manual regeneration function keys Energy saving exhaust temperature control system reduces KW usage Last regeneration duration readout monitor Permanent back up memory Digital Indication of: Inlet Air Temperature Regeneration Exhaust Temperature Heater Core Temperature Over-Temperature Alarm cetlus Listed Control Panel UL Listed Components, CSA Compliant Purge Saver Energy Management System The Purge Saver Energy Management System automatically adjusts energy use to the actual moisture load. Moisture loading is affected by inlet temperature, pressure, relative humidity and flow. These conditions vary throughout the day and rarely combine in such a manner as to produce maximum moisture loads. An inlet temperature reduction of just 0 0 F will reduce the moisture load by almost 50%. EAP Desiccant dryers are sized for worst case operation with the regeneration cycle fixed to accommodate maximum moisture loads. Because the fixed cycle does not compensate for fluctuating loads, the Purge Saver Energy Management System will eliminate the over use of energy by checking the exhaust temperature as the dryer regenerates. When the exhaust temperature reaches the optimum temperature the heater shuts off and the dryer goes into its cool down phase. The Energy Management System can save you hundreds or even thousands of dollars per year in power costs and thousands of dollars per year over competitive refrigerated dryers.

HS Turbo s High Quality Components 3 way Ball Valve The non-lubricated electronically actuated 3 way ball valve is rated for up to cycles per day, yet only moves twice a day. Given the HS Dryer operation, the 3 way ball valve will cycle 365 times per year making the life expectancy of the valve over 30 years. Low Watt Density Heater This industrial duty low watt density heater is rated for over 36,000 hours of operation. Given the HS Dryer operation, the heater will operate an average of 4 hours a day or,460 hours per year, making the life expectancy of the heater over 4 years. Industrial Duty Blower This industrial duty blower is rated for over 50,000 hours of operation. Given The HS Dryer operation the blower will operate on an average of 4 / hours a day or,64 hours per year making the life expectancy of the blower over 7 years. Packaged Filters System Coalescing pre-filter removes oils, hydrocarbons and particle matter prior to entering the air drying column. All pre-filters are provided with a zero loss drain with isolation valve. Particulate after-filters remove solids with 99+% efficiency to micron. Pre-packaging of filters simplifies installation and ensures system integrity Stainless Steel Bezel Pressure Gauge These quality pressure gauges feature a stainless steel case, built-in snubber, acrylic lens, and excellent.5% of full range accuracy.

HS Turbo Dryers vs Refrigerated Dryers HS Turbo Dryer Performance Refrigerated 0 to -40 0 F 99.9% @ 0.3-0.6 Micron 99.9% @ Micron Simple only moving parts. No Certified Technician Required No Refrigerants / Desiccant is inert Dew Point Oil Removal Particle Remover Service Environmental Impact +40 0 to 60 0 F 0% 0% Complex over 50 Moving Parts Certified HVAC Technician is required to Troubleshoot and Fix the Unit Contains Refrigerants and synthetic oils Power Cost Comparison Advantage Turbo 60-3000 SCFM Capacity (SCFM) Non- Cycling Cycling HS Single Tower Heatless Twin Tower Heated Blower Purge 60 $587 $456 $456 $,47 $87 00 $876 $56 $505 $,36 $,05 $,39 $759 $576 $3,544 $,6 $,577 $,6 $659 $4,75 $,389 50 $,577 $,343 $738 $5,906 $,897 300 $,0 $,635 $903 $7,087 $3,404 400 $3,54 $,97 $,70 $9,450 $4,778 500 $3,4 $,90 $,467 $,8 $5,794 650 $4,030 $,90 $,807 $4,74 $6,809 800 $5,68 $3,93 $08 $8,899 $9,96 000 $6,48 $5,98 $,697 $3,64 $3,74 $8,3 $6,3 $3, $9,530 $6,79 600 $9,899 $7,650 $3,64 $37,798 $,67 00 $,089 $7,884 $4,58 $49,60 $6,703 600 $4,788 $9,7 $6,743 $6,4 $33,574 3000 $6,890 $0,868 $7,80 $70,87 $37,634 Note: The HS Turbo Dryer power cost is based on full load conditions and reflects NO power savings from the Purge Saver Energy Management System which comes standard on every unit. Typical Annual Operating Costs based on two shift operation and $0.0/KW The HS Turbo Dryer uses the operating KW only when it is in regeneration mode, and regenerates only once a day. Depending on the moisture load the Turbo can be in the regeneration mode anywhere from to 7 hours. Power Cost Analysis Consult Engineered Air Products to obtain a free power cost analysis comparing dryer types, specific to your application.

HS Turbo Specifications Model SCFM @ 00 PSIG Line Size (Inches) Electrics Dimensions W x D x H (Inches) Unit Shipping Weight (lbs) Maximum Pressure (PSIG) HS60 HS00 HS HS HS50 HS300 HS400 HS500 HS650 HS800 HS000 HS HS600 HS00 HS600 HS3000 60 00 50 300 400 500 650 800,000,,600,00,600 3,000 ½ ½ ½ 3FL 3FL 3FL 4FL 4FL 6/4FL 0V/ 0V/ 0V/ 08-30V/ 08-30V/ 3 x 3 x 76 3 x 3 x 73 3 x 3 x 76 46 x 30 x 78 46 x 30 x 78 46 x 30 x 78 50 x 36 x 84 50 x 36 x 84 50 x 36 x 84 56 x 40 x 87 56 x 40 x 87 56 x 40 x 87 6 x 46 x 94 68 x 5 x 94 68 x 5 x 95 7 x 60 x 95 70 475 560 590 60 940,070,90,5,70,385,50,75,55,575 3,433 Specifications are subject to change without notice. All systems are provided with Engineered Air Tuned Regeneration along with the Purge Saver Energy Management System resulting in maximum KW savings based on air usage. Standard Equipment Purge Saver Energy Management System - Shuts Off Regeneration Cycle when Limit Temperatures are Reached EAP Exclusive Logic Pro Information Center cetlus Listed Control Panel System Inlet and Regeneration Temperature Readouts Mounted Pre and After-Filters Filter Drains Filter Differential Pressure Indication Premium Electronic Switching Valve Tuned Regeneration System (Patented) Industrial Duty Blower Low-Watt density Heater Heater Over-Temperature Protection with Alarm Tower Moisture Indicator Tower Stainless Steel Bezel Pressure Gauges ASME/CRN Pressure Vessel (HS00 and Larger) Purge Exhaust Muffler Full Charge of Desiccant Optional Equipment Three (3) Valve System Bypass Dual Filter Packages High Pressure (to 800 PSIG) Tower Insulation Outdoor Insulation 575V/3 Backed by our 8 Month Bumper to Bumper Warranty TM

Engineered Air Products ph 800.943.794 fax 76.39.885 www.engineeredairproducts.com TM Patents Pending Made in 08 Engineered Air Products, Lancaster, NY 4086 HS-4 56-