Flame Safeguard Fault Code Diagnostics

Similar documents
LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Model 60200FR Gas Primary Control Data Sheet

Indirect gas-fired air heater

New Power Vented Rheem FVIR Tanks

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

XIII Troubleshooting

7800 SERIES Relay Modules

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

OPERATING AND MAINTENANCE MANUAL

Figure 10 or Figure 6

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

R7910A SOLA (Hydronic Control) and R7911 SOLA (Steam Control) Systems

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

RM7897A,C 7800 SERIES Relay Modules

R7120M 7800 SERIES Relay Modules

Eclipse 90 UV Scanner Model A Version 1

Model Universal Oil Primary Control

5.0 ALARMS & TROUBLESHOOTING

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

24 VAC Intermittent Pilot Gas Ignition Control

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

Technical

PE MODEL WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

BGH Series Hot Surface Ignition Control

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

EGH Series 5. Control Supplement. EGH-105 to EGH-125 Natural gas CSD-1 control system

MULTIPLEX SELF RECUPERATIVE gas burner

Eclipse Self-Check UV Scanner

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

RM7838A 7800 SERIES Relay Modules

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

7800 SERIES: EC7895A,C; RM7895A,B,C,D; RM7896A,B,C,D RM7897A,C and RM7898A Relay Modules

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

YP7899C SERIES Burner Management Panel

Cleaver-Brooks CB780/CB784 Operation and Maintenance Manual

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

7800 SERIES EC7810A, EC7820A Relay Module

USER S INFORMATION MANUAL

EG & PEG Series 5 EGH Series 5

RM7890D; RM7895E,F 7800 SERIES Relay Modules

24 VAC Direct Spark Gas Ignition

Electronic Ignition Water Heater

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

INSTALLATION & MAINTENANCE MANUAL GAS FIRED DOOR HEATER Series 79, DH22 AND DH24

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Power Flame Incorporated

RM7895A,B,C,D/EC7895A,C; RM7896A,C,D 7800 SERIES

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Field Start-Up Sheet Direct Fired Gas Equipment

ECLIPSE INFORMATION GUIDE

RM7890; RM Vac 7800 SERIES Relay Modules

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

Manual Revision F Publication Date: 6/9/2014 SPECIFICATIONS. Flame Safety:

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Control manual and troubleshooting guide

TERRACE AND PATIO HEATER HLB-2400/ 2650 SERIES

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

Interrupted Ignition Series Oil Primary Control

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

FIREYE FLAME SCANNERS

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

24 VAC SYSTEM CONTROL KIT

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

Instruction Manual 826 7/22/2009. Eclipse Bi-Flame Dual Burner Monitoring System Model 6500 Version 1

CEI Jacketed Firebox Heater Operation, Service & Parts Manual

QHT Manual for: SU-2A Gas Burner

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

7800 SERIES RM7824A Relay Module

DYNATRAIL INSTALLATION, OPERATING, AND SERVICE INSTRUCTIONS. For Model NT-45M. 45,000 BTU Gas Furnace 12 Volt AC

Triton Series High Efficiency Boiler

7800 SERIES RM7840E,G,L,M Relay Module

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Model No: Little Devil II (inc ss)

PrecisionTemp Shower-Mate

Hot Surface Ignition (HSI) System Booklet

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

Forced draught gas burner

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

Burn Easy Installation Instructions LP or Natural Gas Fired Units. Cremator Setup:

EUROBOX SERIES TYPES CM...N SM...N MM...N

24 VAC SYSTEM CONTROL KIT

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

FIREYE C9707A ALL FUEL SCANNER

Transcription:

Vino s Vine Tech Tips Series 02/2013 Flame Safeguard Fault Code Diagnostics As manager of Tech Services, it probably comes as no surprise I spend some time discussing fault codes and corresponding corrective actions. If there is only one thing you ever do, because I recommended you to do so, is this GET A HONEYWELL KEYBOARD DISPLAY MODULE it pinpoints the issue and saves hours of time. For example, a blinking 22 fault code on the flame safeguard corresponds to flame signal absent. Well Joyce, what does this mean? It could be the pilot, main flame, or a fault during ignition - which obviously leads to more questions and required trouble-shooting. However with the Display Module, a direct read-out identifies the fault and when it occurs. Blinking Code We know right where to go, trust me this little device will save you hours and pay for itself in one call. I have compiled a list of faults I see and what to do to correct them (see below). As always, feel free to call in. Joyce Vino Attachments: Honeywell Trouble Shooting for TS boilers - Blinking Codes Honeywell Trouble Shooting for TS boilers Keyboard Display Module

Trouble Shooting Full Modulation Evolution Boilers BLINKING CODES Fault Code 1-1, Low Line voltage Check incoming line pressure at back of boiler in junction box. Fault Code 2-1, Flame sensed when not expected Make sure there is no flame present in combustion chamber Remove the amplifier and check connections Remove the UV scanner from pilot still wired up and see if it is strobing. If it is, it is bad. Replace it. Fault Code 2-2, Main flame failure during RUN Check the main gas valves for proper operation Check the gas supply for proper pressure Confirm all manual gas shut-off valves are open (inside and outside boiler jacket) Confirm flame is bright orange when firing on high and low fire If not, adjust combustion to obtain O2 readings between 5% and 6% Check flame signal on high fire and also low fire If flame signal is unsteady at low fire check the following: Remove pilot assembly and make sure insulation above the burner is not in way of UV scanner If so, use large screwdriver to push insulation back (be careful not to damage burner) UV scanner could be getting hot Check heat block below UV scanner for cracks Make sure heat block is in place and UV scanner connection is tight Install a new air cooled pilot assembly Fault Code 2-2, Main flame failure during IGNITION Confirm all manual gas shut-off valves are open (inside and outside boiler jacket) Check the main gas valves for proper operation Check the gas supply for proper pressure Check for proper gas line sizing (if main gas line is too small pilot could be extinguished when main gas valves open observe pilot when main gas valves open, confirm it remains burning) If fan was replaced, be sure air orifice between fan and mixer was re-installed

Fault Code 2-2, Pilot flame failure Check flame signal during 1 st 5 seconds of pilot ignition (PFEP is 10 seconds) If it is 0vdc, no spark is present Check ignition transformer and ignition cable Check ignition electrode for cracked ceramic insulator Remove pilot assembly and check for carbon build-up or carbon thread between electrode and pilot assembly (clean and replace) Check and tighten pilot assembly ground wire Fault Code 2-2, Pilot flame failure (continued) If it is 5vdc for 5 seconds then drops to 0vdc for 6 thru 10 seconds, spark is present, but not gas Boiler has early spark termination, ignition transformer shuts off after 5 seconds Confirm pilot manual gas cock is open (rear of boiler) Check and measure pilot gas pressure adjust as needed to assure blue pilot flame Check operation of pilot solenoid valve Remove gas tubing going to pilot assembly and check gas orifice in brass elbow fitting Remove and clean gas orifice (set screw with hole drilled in it) if needed, then replace orifice Fault Code 3-1, Running interlock during prepurge (air switch circuit ) Check to make sure fan is starting on a call for heat If so, air switch must make with-in 10 seconds or lock-out will occur Check for a blockage in the air inlet ducting Check air tubing going to air switch for blockage or loose connections Check for cracks in air switch housing Check proper operation of air switch, (air switch closes at 0.5 W.C. air pressure) Check to see if fan coming up to speed quickly (look at vfd display) If not, check acceleration time in programming of vfd (see vfd manual and vfd parameter list) If fan is starting, but then slowing down before making air switch Check to see if CRA1 relay coil is losing 120vac signal from Flame safeguard Check the CRA1 relay for tight connections Remove relay from socket and firmly replace Wiggle relay while fan is starting, does display on vfd flash erratically? Install new My2 relay and new relay socket If fan is not starting, check all of the above and then the following Is vfd in a fault condition (see vfd manual to check faults) Check the connections between the vfd and the fan motor Check the fan motor for electrical failure

Fault Code 3-1, Running interlock (air switch circuit during RUN) Put the boiler in manual mode (press and hold the exit button on RWF40 for 5 seconds) Run the boiler on low fire and check the air pressure going to the air switch If it is 0.5 W.C. or less, increase the low fire Hz setting of the vfd (see vfd manual) If it is above 0.5 W.C., replace air switch (air switch closes at 0.5 W.C. air pressure) Check for loose air tubing connections between fan and air switch Check for cracks in air switch housing Is fan slowing down below low fire Hz setting Check to see if CRA1 relay coil is losing 120vac signal from Flame safeguard Check the CRA1 relay for tight connections Remove relay from socket and firmly replace Wiggle relay while fan is running, does display on vfd flash erratically? Install new MY2 relay and new relay socket Is vfd in a fault condition (see vfd manual to check faults) Check the connections between the vfd and the fan motor Check the fan motor for electrical failure Fault Code 3-2, Running ILK On Airflow switch is closed when it should be open. Airflow switch could be faulty or if you were troubleshooting with jumpers you may have left the jumper on the airflow switch. You can not start the boiler with a jumper on the switch. remove it. Fault Code 4-1, No Purge Card The purge card is missing. Replace it. When you get a new Honeywell flame safeguard as a replacement part, it does not come with the purge card or amplifier card. You must move them to the new control from the old one. Code 4-4, Jumper Wrong Jumper configuration was changed after the 200 hr. burn it time. The control has to be replaced. You cannot cut the jumpers after 200 hrs.of operation. Fault Code 5-1, Preignition ILK Occurs with IRI POC if the POC switches are not working or making in time. Check POC on valves to determine which one is bad. Replace actuator. You cannot repair the switches.

Fault Code 5-2, high fire sw., low fire switch on If you have a low proven start option on the boiler, make sure the gap on the spark plug is 1/8. If it is not a low proven start boiler and you replaced the Honeywell Flame Safeguard base, make sure there is a jumper from 18 to 19.

Trouble Shooting Full Modulation Evolution Boilers WITH A KEYBOARD DISPLAY MODULE Fault Code 1, No Purge Card The purge card is missing. Replace it. When you get a new Honeywell flame safeguard as a replacement part, it does not come with the purge card or amplifier card. You must move them to the new control from the old one. Fault Code 10 or 33, Pre-Ignition ILK Occurs with IRI POC if the POC switches are not working or making in time. Check POC On valves to determine which one is bad. Replace actuator. You can not repair the switches. Fault Code 11 or 12, Running ILK On Airflow switch is closed when it should be open. Airflow switch could be faulty or if you were troubleshooting with jumpers you may have left the jumper on the airflow switch. You can not start the boiler with a jumper on the switch. remove it. Fault Code 14, 20, 31, or 45, High Fire Switch, Low Fire Switch On If you have a low proven start option on the boiler, make sure the gap on the spark plug is 1/8. If it is not a low proven start boiler and you replaced the Honeywell Flame Safeguard base, make sure there is a jumper from 18 to 19. Fault Code 9, 15, or 18, Flame sensed when not expected Make sure there is no flame present in combustion chamber Remove the amplifier and check connections Remove the UV scanner and look into the lens. If it is strobing, it is defective. Replace it. Fault Code 17, Main flame failure during RUN Check the main gas valves for proper operation Check the gas supply for proper pressure Confirm all manual gas shut-off valves are open (inside and outside boiler jacket) Confirm flame is bright orange when firing on high and low fire If not, adjust combustion to obtain O2 readings between 5% and 6% Check flame signal on high fire and also low fire If flame signal is unsteady at low fire check the following: Remove pilot assembly and make sure insulation above the burner is not in way of UV scanner

If so, use large screwdriver to push insulation back (be careful not to damage burner) UV scanner could be getting hot Check heat block below UV scanner for cracks Make sure heat block is in place and UV scanner connection is tight Install a new air cooled pilot assembly Fault Code 19, Main flame failure during IGNITION Confirm all manual gas shut-off valves are open (inside and outside boiler jacket) Check the main gas valves for proper operation Check the gas supply for proper pressure Check for proper gas line sizing (if main gas line is too small pilot could be extinguished when main gas valves open observe pilot when main gas valves open, confirm it remains burning) If fan was replaced, be sure air orifice between fan and mixer was re-installed If you notice a hard light off or a woofing at ignition, you need to add more gas. If you do not Have more gas available on the jobsite, call the factory to see what we can turn the purge down to for a smoother light off. You must have 4 air changes. We can give you the allowable min setting for purge. Fault Code 28, Pilot flame failure Check flame signal during 1 st 5 seconds of pilot ignition (PFEP is 10 seconds) If it is 0vdc, no spark is present Check ignition transformer and ignition cable Check ignition electrode for cracked ceramic insulator Remove pilot assembly and check for carbon build-up or carbon thread between electrode and pilot assembly (clean and replace) Check and tighten pilot assembly ground wire Fault Code 28, Pilot flame failure (continued) If it is 5vdc for 5 seconds then drops to 0vdc for 6 thru 10 seconds, spark is present, but not gas Boiler has early spark termination, ignition transformer shuts off after 5 seconds Confirm pilot manual gas cock is open (rear of boiler) Check and measure pilot gas pressure adjust as needed to assure blue pilot flame Check operation of pilot solenoid valve Remove gas tubing going to pilot assembly and check gas orifice in brass elbow fitting Remove and clean gas orifice (set screw with hole drilled in it) if needed, then replace orifice Fault Code 29, Lockout interlock (air switch circuit ) Check to make sure fan is starting on a call for heat If so, air switch must make with-in 10 seconds or lock-out will occur Check for a blockage in the air inlet ducting Check air tubing going to air switch for blockage or loose connections

Check for cracks in air switch housing Check proper operation of air switch, (air switch closes at 0.5 W.C. air pressure) Check to see if fan coming up to speed quickly (look at vfd display) If not, check acceleration time in programming of vfd (see vfd manual and vfd parameter list) If fan is starting, but then slowing down before making air switch Check to see if CRA1 relay coil is losing 120vac signal from Flame safeguard Check the CRA1 relay for tight connections Remove relay from socket and firmly replace Wiggle relay while fan is starting, does display on vfd flash erratically? Install new My2 relay and new relay socket If fan is not starting, check all of the above and then the following Is vfd in a fault condition (see vfd manual to check faults) Check the connections between the vfd and the fan motor Check the fan motor for electrical failure Fault Code 30, Running interlock (air switch circuit during RUN) Put the boiler in manual mode (press and hold the exit button on RWF40 for 5 seconds) Run the boiler on low fire and check the air pressure going to the air switch If it is 0.5 W.C. or less, increase the low fire Hz setting of the vfd (see vfd manual) If it is above 0.5 W.C., replace air switch (air switch closes at 0.5 W.C. air pressure) Check for loose air tubing connections between fan and air switch Check for cracks in air switch housing Is fan slowing down below low fire Hz setting Check to see if CRA1 relay coil is losing 120vac signal from Flame safeguard Check the CRA1 relay for tight connections Remove relay from socket and firmly replace Wiggle relay while fan is running, does display on vfd flash erratically? Install new MY2 relay and new relay socket Is vfd in a fault condition (see vfd manual to check faults) Check the connections between the vfd and the fan motor Check the fan motor for electrical failure Fault Code 50, Jumper Wrong Jumper configuration was changed after the 200 hr. burn it time. The control has to be replaced. You can not cut the jumpers after 200 hrs.of operation.