Development of the Closed-Cycle Dilution Refrigerator for Space Applications

Similar documents
Development of Helium-3 Compressors and Integration Test of Closed-Cycle Dilution Refrigerator System

Pocket Dilution Cooler

Development of a Dilution Refrigerator for Low-Temperature Microgravity Experiments

Concept of a Powerful Cryogen-Free Dilution Refrigerator with Separate 1K Stage

A 2 K Active Magnetic Regenerative Refrigeration System for Remote Cooling

Remote Helium Cooling Loops for Laboratory Applications

10 K Airborne Cryocooler and

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Requirements for Repair of a Miniature Liquid Helium-3 Refrigerator

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

Thermal performances of a meter-scale cryogenic pulsating heat pipe.

Available online at ScienceDirect. Physics Procedia 67 (2015 )

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Properties of a two stage adiabatic demagnetization refrigerator

Design and Fabrication of a Cool Box for Passenger Car using Automotive Air-conditioning System

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Demonstration of a Two-Stage Turbo- Brayton Cryocooler for Space Applications

The dilution process. 4K flange. Still. Heat exchangers. Mixing chamber

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

A CRYOGENIC TEST STATION FOR SUBCOOLING HELIUM HEAT EXCHANGERS FOR LHC

Nova Movie: Absolute Zero

15. Heat Pipes in Electronics (1)

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

Development of a meter-scale U-shaped Oscillating Heat Pipe for GAPS

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

High-efficiency Turbo Chiller (NART Series)

An ultra-low vibration cryocooling kit based on a miniature Rotary Compressor

Adsorption refrigeration system using waste heat

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Design and Operation of a Cryogenic Nitrogen Pulsating Heat Pipe

Efficiency of Non-Azeotropic Refrigerant Cycle

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

High Performance Diesel Fueled Cabin Heater. Abstract

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Low Temperature Separation Systems. Separation Process

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

How Wicks and Orientation

(Refer Slide Time: 00:00:40 min)

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Experimental Study of Heat Transfer in a Container Filled with Water and Cooled by a Peltier Device

Performance Assessment of Water Cooled Condenser Refrigeration System

Performance of an Improved Household Refrigerator/Freezer

THE THERMOSIPHON COOLING SYSTEM OF THE ATLAS EXPERIMENT AT THE CERN LARGE HADRON COLLIDER

Modelling the Performance of a Diffusion Absorption Refrigeration System

Variable Thermal Conductance Link for Lunar Landers and Rovers

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Sub-Critical Operation of the CO2 Expander/ Compressor

Vibration Services. Centre Spatial de Liège. Advanced Technologies Space Instruments Test Services. Analysis. Test. Model Adaptation.

4th IIR International Conference on Thermophysical Properties and Transfer Processes of Refrigerants 2013

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

A Microcryostat for Refrigeration at 1.8 K

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Thermal Performance of a Loop Thermosyphon

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

IV SEMESTER DIPLOMA EXAMINATION, JANUARY-2013 THERMODYNAMICS

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

RIGID DC LIQUID CHILLER

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

COOPERATIVE PATENT CLASSIFICATION

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Air Liquide Advanced Technologies Division Sassenage, 38360, France

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Refrigeration Systems and Accessories

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Transcription:

447 Development of the Closed-Cycle Dilution Refrigerator for Space Applications S. Martin 1, A. Volpe 2, G. Vermeulen 2, P. Camus 2, S. Triqueneaux 2, J. Butterworth 1, S. D Escrivan 3, T. Tirolien 4 1 Air Liquide Advanced Technologies, 38360 Sassenage, France 2 Institut Néel/CNRS, 38042 Grenoble, France 3 CNES, 31401 Toulouse, France 4 ESA/ESTEC, 2201 AZ Noordwijk, Netherlands ABSTRACT We present the development of the closed-cycle dilution refrigerator (CCDR) derived from the open-cycle dilution refrigerator (OCDR) used in the Planck mission. Unlike the OCDR, the two isotopes 4 He and 3 He are circulated (with a fountain pump for the 4 He and with a compressor for 3 He) instead of rejecting to space in order to increase the lifetime of the system. Each individual block is working and the full system is under development. In this work, we discuss the development of the different parts of the CCDR and the next steps to be performed in order to achieve the cryogenic performance for a future mission (1μW at 50mK). We address more specifically the 3 He compressor options and the status of one solution identified as the Holweck compressor. Then, we propose a possible integration according to constraints of the future space missions. INTRODUCTION The gravity insensitive open cycle dilution fridge (OCDR) was developed for use in the Cosmic Microwave Background (CMB) of the Planck mission. The main breakthrough of this system consists of mixing 3 He and 4 He due to its capillaries forces and not to gravity as in a standard dilution refrigerator. In the OCDR, the two isotopes were injected from two separate reservoirs into the mixing chamber and then they were ejected into space. The OCDR provides 0.1μW at 100 mk for 2.5 years with a continuous flow of 5.4 μmol/s of 3 He and of 14.5 μmol/s of 4 He 1. The current mission projects (ATHENA+/X-IFU, COrE, Prism) need a greater cooling power (1 μw at 50 mk) for a longer time, typically 5 years. It is not realistic to use OCDR as a possible sub-kelvin cooler because of the quantity of isotopes needed for this mission. Hence, the cycle must be closed. In a promising development, a gravity insensitive Closed Cycle Dilution Refrigerator (CCDR) has already reached a performance of 1 μw at 51 mk 2,3. Cryocoolers 18, edited by S.D. Miller and R.G. Ross, Jr. International Cryocooler Conference, Inc., Boulder, CO, 2014 475

448 476 SUB-KELVIN, THERMOELECTRIC, Sub-Kelvin, Thermoelectric, AND NOVEL and Novel REFRIGERATORS Refrigerators 3 He pump Fountain pump (~2.1K) Phase separator (~1-1.1K) Counter flow heat exchanger (~7m) Heat intercepts between 1K 50mK Mixture 3 He 4 He Figure 1. Schematic view of the CCDR. THE CLOSED-CYCLE DILUTION REFRIGERATOR Figure 1 shows the CCDR. The key principle is to inject the two helium isotopes through two separate capillaries and mix them in a third one. The Y junction between the three capillaries is the equivalent to a mixture chamber in a standard dilution fridge. At temperature below 100 mk, the solubility of 3 He in the dilute is limited to 6.6%. If the quantity of 3 He exceeds this value, not all 3 He is diluted but some stays in concentrated phase to form droplets that fill the cross section of the capillaries where capillary forces play the role of gravity. The liquid mixture produced in the mixture chamber goes into the counter flow heat exchanger to pre cool the 3 He and the 4 He returning from the still. Then, it enters the still where the two isotopes are separated. The superfluid 4 He is extracted with a fountain pump which can only extract superfluid 4 He so it has to work below the lambda point of 4 He (2.17K). The 3 He is extracted by pumping the rich gaseous phase with a pump working at much higher temperature (15K or 300K). The almost pure 3 He (~95%) is then re-condensed into the CCDR. In order to work under zero gravity, the liquid vapor phase separation has to be realized into a porous materiel to confine the liquid. This porous material can be made of Procelit 160 that has a porosity of about 90% and has been used in 3 He sorption cooler for space application 4. The 3 He pressure in the still shall be in the range 5-10 mbar in order not to affect the cooling performance as shown in Figure 2. The cooling power is dominated by the 4 He flow rate rather than 3 He flow rate since all 4 He goes into the dilute phase while only a fraction of 3 He is diluted. The 3 He flow rate needed is 18.1 μmol/s, as compared to the 350 μmol/s for the 4 He. Along the counter flow heat exchanger from 1 K to 50 mk, a continuous cooling power can be provided to electrical wires, and the mechanical support without affecting the cold tip temperature. A heat sink at 1.7 K is needed to reduce the heat load on the still and to re-condense 3 He. In the situation described above, a cooling power of about 5 mw is needed at 1.7K.

CLOSED-CYCLE DILUTION REFRIGERATOR FOR SPACE 477 449 Figure 2. Temperature of a detector simulator versus the heat applied to the simulator for a still pressure of 0.3 (red), 5 (green), 10 (blue), and 15 mbar (cyan). 3 HE PUMP SOLUTIONS To achieve a cooling power of 1 μw at 50 mk, the 3 He flow rate needs to be around 20 μmol/s (corresponding to 0.7L/s at 300K) with an inlet pressure of 5 mbar and an outlet pressure of 200mbar. There is currently no space qualified compressor that satisfies those requirements. Three solutions are under investigation: - A system based on existing space linear compressors developed by JAXA-SHI for a 1Kclass JT cooler in the frame of the SPICA mission 5. - A cryogenic sorption compressor operating at 15 K developed by the University of Twente & Cooll SES. It is based on compressor cells and components developed for the DARWIN mission 6. - An optimized turbopump Holweck-type room temperature compressor developed by Institut Néel/CNRS and Air Liquide Advanced Technologies. The linear compressor from JAXA-SHI is the most mature solution. The sorption compressor from COOLL has the advantage to generate no micro-vibration and has quite low power consumption (<10 W). The Holweck compressor needs to be space qualified but it is an interesting alternative to the linear compressor in terms of micro-vibration (operate at 1,000 Hz instead of 50 Hz) and a small mass (~2.2 kg instead of 20 kg). HOLWECK COMPRESSOR The Holweck compressor is a molecular drag pump. It is often used as the last stage of a commercial turbo-molecular pump. It consists of helicoidal grooves that drag the fluids in the Knudsen regime. The high speed rotor transfers its energy to the particles of the gas along the grooves. Figure 3 shows a cross section of such groove with all the critical dimensions. The depth of the grooves is progressively increased in order to increase the pressure from 5 mbar to 200 mbar. This pump has been designed and manufactured according to the main requirements from the CCDR (see Table 1). The sizing of the pump has been done thanks to an analytical model developed by Institut Néel/CNRS 7. The model has been validated from an existing commercial Holweck-type pump from Adixen. This model provides the sizes of the grooves, the diameter of the shaft, the radial clearance between the rotor and the stator, the length and the helix angle.

450 478 SUB-KELVIN, THERMOELECTRIC, Sub-Kelvin, Thermoelectric, AND NOVEL and Novel REFRIGERATORS Refrigerators Figure 3. Geometry of the Holweck pump Table 1. - Requirements for the CCDR 3 He compressor Temperature Inlet pressure Outlet pressure Flow rate Working gas Electrical power 300 K 5 mbar 200 mbar 30 μmol/s 3 He <100 W The tests on the manufactured model are presented on Figure 4. It shows the pressure difference versus the inlet pressure for two different speed (700 Hz/42 krpm and 900 Hz/54 krpm) at zero flow. In the viscous regime, the pressure difference should scale with the shaft speed and is apparent above 10 mbar. However at lower inlet pressure, the viscous regime is left due to the rarefaction of the gas and the differential pressure decreases as the inlet pressure decreases. We see that for an inlet pressure of 5 mbar, the outlet pressure is 200 mbar as specified. Figure 4. Compression ratio versus the inlet pressure. It has been done for 2 different shaft speeds (42krpm and 54krpm) at zero flow. The points are the experimental points and the lines are the model.

CLOSED-CYCLE DILUTION REFRIGERATOR FOR SPACE 479 451 The prototype is mounted on balls bearings and we measure, for a total electrical power of 100 W, less than 50 W losses in the bearings. For space application, balls bearings are not suitable in terms of reliability. They will be replaced by gas bearings (MELFI heritage in Air Liquide Advanced Technologies) or by magnetic bearings already used in other space qualified turbo pump. From an analytical model validated by an existing pump it can be seen that a prototype of a Holweck-type pump that meets the requirements for the CCDR can be built. From this model, we could adjust the design of the pump to be integrated in other applications like the first stage of a turbo-molecular pump or the first stage of JT cooler in order to reduce the outlet pressure of the JT down to 10 mbar (current JT coolers have a downstream pressure of about 100mbar). INTEGRATION ON FUTURE SPACE MISSION In order to reach a cooling power of 1μW at 50 mk, the main requirements for the CCDR are the following: - A heat sink at 1.7 K with a cooling power available of about 5 mw. - A 3 He pump with a flow rate of 15-30μmol/s and an outlet pressure of at least 100mbar in order to re-condense 3 He at 1.7K. Compare to the OCDR, the CCDR provides important improvements for future space mission with a longer lifetime, a lower temperature with a higher cooling power. It has already been studied at a system level for space mission like SPICA 8, ATHENA/IXO 9 or COrE 10. Another way of reaching a sub-kelvin temperature is the use of an Adiabatic Demagnetization Refrigerator (ADR) 11 which is more mature than the CCDR. However, the CCDR has many advantages as compared to the ADR: - the counter flow heat exchanger provides several thermal anchor from 1K to 50mK for electrical wiring and support structure instead of a few discrete pre-cooling stages. - the CCDR does not generate any magnetic field that may affect the detectors strongly sensitive to residual magnetic field - the absence of magnets and magnetic shielding makes the system much lighter (3-10 kg for the ADR, as compared to 1kg). This is of great importance. The focal plane assembly (FPA) on a future mission will have a higher mass than on Planck (currently the FPA is around 6kg). - CCDR operation is intrinsically continuous which avoids thermal cycling and slow thermal relaxation. CONCLUSION The CCDR provides strong advantages compare to current system planned on future space mission and satisfy the current requirements of the missions. The main constraint for the cooling chain is to be able to provide a cooling power of about 5 mw at 1.7 K. A prototype with all the low temperature elements (mixing chamber, still, fountain pump and counter flow heat exchanger) in a single set up should be tested this year and a coupled test with space compatible 3 He compressor is planned this year too. Those tests should bring the CCDR to a Technology Readiness Level (TRL) compatible mission requirement of the Phase B studies. The Holweck-type pump as a 3 He circulator seems to be a good solution since it is a compact solution with a low mass and reasonable power consumption. We also show that this compressor can be applied to a variety of other applications like in 1K class JT cooler or turbo molecular pump. ACKNOWLEDGEMENTS This research was funded by the Centre National d Etudes Spatiales (CNES) and by the European Space Agency (ESA). The authors would like to thank the JAXA/SHI development

452 480 SUB-KELVIN, THERMOELECTRIC, Sub-Kelvin, Thermoelectric, AND NOVEL and Novel REFRIGERATORS Refrigerators team (S. Keisuke, H. Sugita, Y. Sato and K. Mitsuda), H.J.M. ter Brake (University of Twente), J.F. Burger (Cooll SES) and F. Durand (ALAT) for their useful information on the compressor technologies. REFERENCE 1. Triqueneaux, S., et al., Design and performances of the dilution cooler system for the Planck mission, Cryogenics, Vol. 46, Issue 4 (2006), pp. 288-297. 2. Martin, F., et al., A closed cycle 3 He- 4 He dilution refrigerator insensitive to gravity, Cryogenics, Vol. 50, Issue 9 (2010), pp. 623-627. 3. Chaudry, G., et al., A closed cycle dilution refrigerator for space applications, Cryogenics, Vol. 52, Issue 10 (2012), pp. 471-477. 4. Duband, L., et al., Herschel flight models sorption coolers, Cryogenics, Vol. 48, Issue 3-4 (2008), pp. 95-105. 5. Shinozaki, K., et al., Development of 1-4K class space mechanical coolers for new generation satellite missions in JAXA, Cryocoolers 16, ICC Press, Boulder, CO (2011). 6. Burger, J.F., et al., Long-life vibration-free 4.5K sorption cooler for space applications, Rev. Sci. Instr., Vol. 78, Issue 6 (2007), 065102. 7. Unpublished work, Institut Néel CNRS, France. 8 Holmes, W., et al., Sub-Kelvin cooler configuration study for the Background Limited Infrared Submillimiter Spectrometer BLISS on SPICA, Cryogenics, Vol. 50, Issue 9 (2010), pp. 516-521. 9. Triqueneaux, S., et al., Potential cooling chains for the NFI instruments of XEUS, Cryogenics, Vol. 48, Issue 5-6 (2008), pp. 174-180. 10. Bouchet, F.R., et al., COrE (Cosmic Origins Explorer) A white paper, arxiv preprint arxiv:1102.2181 (2011). 11. Luchier, N., et al., Performance of the 50 mk ADR/sorption cooler, Cryogenics, Vol. 50, Issue4-6 (2012), pp. 522-528.