C1210ES Tankless Water Heater

Similar documents
C1050ES Tankless Water Heater

940ES Tankless Water Heater

940ES Tankless Water Heater

C1210ESC Tankless Water Heater

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

940ESO Tankless Water Heater

Commercial Tankless Rack System

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Commercial Tankless Rack System

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Residential/Commercial Gas Condensing Tankless Models

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Concentric Vent / Air Intake Kit Stainless Steel

GB Condensing Gas Boiler

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Tankless Condensing High Efficiency Water Heaters

Residential Gas Tankless Water Heater

Commercial Tankless Rack System

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

GB Condensing Gas Boiler

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

GB Condensing Gas Boiler

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

iq251, Gen II Submittal Data

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

The WCGH High Efficiency Commercial Water Heater with Storage Tank

10 : 1 Turndown Ratio

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

Suggested Specifications Prestige Excellence 110

iq1001, Gen II Submittal Data

C 950 / 1050 ES C 950 / 1050 ES - Natural Gas / C 950 / 1050 ES - Liquefied Petroleum (LP) Gas

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

C 1050 ES - Natural Gas C 1050 ES - Liquefied Petroleum (LP) Gas

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

Tankless Water Heaters

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Date: Project #: Engineer: Prepared By: Bid Date:

C 1210 ES/ESC - Natural Gas C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Bosch Greentherm Series

RTG 199 HE INDOOR MODEL. RTG 199 HEN - Natural Gas RTG 199 HEX - Propane (LP Gas) Installation and Operation instructions

TL-Pro 175C/199C INDOOR MODEL. TL-Pro 175/199 C - Natural Gas TL-Pro 175/199 C- Propane (LP Gas) Installation and Operation instructions

G515/7 Cast Iron Boiler

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

G615/11 Cast Iron Boiler

Installation and Operation Instructions Manual

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

On-Demand Water Heater Installation Manual and Owner s Guide

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

Commercial Gas Water Heaters

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION

DIVISION FINNED WATER-TUBE BOILERS

Automatic Circulating Water Heaters

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

Residential & Commercial

Utica Boilers MAC Submittal

advanced : technology

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

DIVISION FINNED WATER-TUBE WATER HEATERS

i200, Gen II i250, Gen II Submittal Data

Commercial Gas Water Heaters

WATER-TUBE POOL HEATERS

Installation and Operation Instructions Manual

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

DIVISION FINNED WATER-TUBE BOILERS

MECHANICAL VENTING VERSATILITY

AFUE 95% Heating Input 50,000 to 200,000 Btuh

HIGH OUTPUT. Skin design RANGE

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

MODEL GWH 2400 ES NG and GWH 2400 ES LP - INDOOR MODEL

WATER-TUBE POOL HEATERS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Greentherm 9800 SE 160/199 SEC 199

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

CAUTION. Requests to Installers In order to use the water heater safely, read this installation manual carefully, and follow the installation

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION. Requests to Installers

Revitalize Building Mechanical Systems (4619)

MODEL GWH 2700 ES NG and GWH 2700 ES LP - INDOOR MODEL

FINNED WATER-TUBE POOL HEATERS

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Commercial Gas Water Heaters

TABLE OF CONTENTS BRADFORD WHITE BOILERS

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

C 1210 ES/ESC C 1210 ES/ESC - Natural Gas / C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

Commercial Applications

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Transcription:

Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E Hot water outlet Cold water inlet F H J C I K G Front view Side view Bottom view Gas supply connection Bottom view Condensate drain Dimensions Unit A B C D E F G H I J K Value Inches 30½ 17⅞ 5¼ 11¼ 2¾ 6⁵ ₁₆ 2⁵ ₁₆ 6½ 2¹ ₁₆ 4¹ ₁₆ 6⅝ Engineering Specifications Water heater shall be a Model Therm C 1210 ES. Plant shall consist of Model Therm C 1210 ES NG/LP tankless water heaters as manufactured by Bosch Thermotechnology Corp. Heater shall be CSA/ANSI Z21.10.3 listed. Heater shall have an input of 225 MBH with a gross output of 211 MBH when fired with natural gas. Unit shall operate with a minimum of 94% ANSI Z-21 efficiency. Tankless water heater shall have a recovery of 329 gallons per hour at a 77 F temperature rise. Tankless water heater shall have Low NOx emissions and is 2012 SCAQMD NOx certified to rule 1146.2. CONSTRUCTION Water heater shall be of gas fired, condensing tankless design with a modulating power burner and negative pressure gas valve. Burner shall be capable of 9:1 turndown of firing, without loss of combustion efficiency. Primary heat exchanger/ combustion chamber shall incorporate a multi pass copper tube and fin design with internal turbulators. Secondary condensing heat exchanger shall incorporate a multi-pass aluminum heat exchanger of fin tube design with copper water path to prevent 1 of 6 galvanic corrosion. Heat exchangers shall be rated for working pressure not less than 145 psig. Exhaust outlet connector shall be of corrosion resistant metal, with a 3 diameter flue connection. The water heater control system shall be a single printed circuit board in water-resistant plastic enclosure. The entire system shall be Underwriters Laboratories approved. The control system shall contain: embedded control board incorporating LCD display to read temperature, and tactile buttons for output power, temperature, and programming control; CPU board which houses all control functions; power transformer; ignition spark module; and unique connections for each sensor or component. The control board shall be field replaceable. The combustion safeguard/flame monitoring system shall utilize spark ignition and a rectification type flame sensor. The control panel hardware shall support wireless remote communications if the wireless module is installed.

Engineering Specifications The controls shall include extensive self-diagnostic capabilities that incorporate a minimum of 18 separate fault codes and 8 programmable system categories. The water heater comes equipped with power cord and shall operate on 120V/1/60Hz electrical service. INSTALLATION All aspects of installation of Water Heater Plant shall be in strict accordance with manufacturer s instructions. Materials shall conform to all manufacturer s recommendations including a manufacturer listed vent system. Water heater plant piping shall be field constructed of materials as specified. Water heater shall be installed with individually isolating shutoff valves for service and maintenance, and a hot water hose connection for field testing. Unit shall have an ASME approved temperature/pressure relief valve with a setting of 150 psig. Water heater shall require a minimum gas pressure of 3.5 W.C. (Natural Gas) at 1,000 scfh (full load rated capacity). MODE OF OPERATION Heater shall include integral factory wired operating controls to control all operation and energy input. Control of discharge water temperature shall be set through an internal setpoint with a field adjustment of 100 F to 140 F. Heater shall be capable of maintaining the outlet temperature within an accuracy of ±3 F. This shall be accomplished by modulation of firing rate from 100% to 11% of rated input. Unit shall operate with an Inverse Efficiency Curve, with maximum efficiency achieved at minimum firing input. CONTROLS INTEROPERABILITY The control board may be linked to other Bosch tankless water heaters through the use of a cascading kit. This accessory shall cause the unit to perform as described above while activating or deactivating other units in the system. Additional Bosch tankless water heaters shall be plumbed in parallel and located near the main unit. WARRANTY The heat exchangers shall carry a 15-year warranty against leakage due to defects in materials or workmanship or corrosion in a residential, non-direct recirculation system, subject to the manufacturer s water quality requirements. All other parts and components shall carry a 5 year warranty against defects in materials or workmanship. OR The heat exchangers shall carry a 5-year warranty against leakage due to defects in materials or workmanship or corrosion in a commercial installation, subject to the manufacturer s water quality requirements. All other parts and components shall carry a 5 year warranty against defects in materials or workmanship. Performance Data Unit Value Maximum gas input BTU 225,000 Minimum input BTU 25,000 Maximum output BTU 210,000 Minimum output BTU 23,000 Thermal efficiency % 94 2 of 6

Operational Data Unit Value C 1210 ES NG / Natural Gas - part number 7703311073 C 1210 ES LP / Liquid Propane - part number 7703411071 Weight LBS 88 Electrical voltage mains VAC / Hz 120 / 60 Power consumption max load A 2.5 Power consumption idle ma 40 Min. Inlet gas pressure NG / LP Inch W.C. 3.5 / 8 Max. Inlet gas pressure NG / LP Inch W.C. 10.5 / 13 C1210ES Maximum Output Temperature F 140 Max. Working pressure PSI 145 Min. Working pressure PSI 30 Min. Activation rate GPM 0.5 Relief valve pressure rating PSI 150 Venting category IV Approved vent or combustion air pipe material - United States Approved vent or combustion air pipe material - Canada PVC schedule 40, PVC-DWV, CPVC schedule 40, ABS-DWV sched. 40 CSA or ULC certified only (ULCS636) Clearances W1 W5 W3 W1 W1 W2 W4 Description Unit Minimum clearance Top View * 24 inches recommended for servicing. Front View Side clearance W1 Inch 1 Front clearance W2* Inch 1 Top clearance W3 Inch 12 Floor clearance W4 Inch 12 Rear clearance W5 Inch 0 3 of 6

Required direct vent terminal clearances (twin pipe / concentric penetration) Clearance Data Item Description Value Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony Inch 12 12 B Clearance to window or door that may be opened Inch 36 12 C Clearance to permanently closed window Inch * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Inch * * E Clearance to unventilated soffit Inch * * F Clearance to outside corner Inch * * G Clearance to inside corner Inch * * H Clearance to each side of center line extended above meter/ regulator assembly 36 in. within a height 15 feet above meter/ regulator assembly * I Clearance to service regulator vent outlet Inch 36 * J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other application Inch 36 * K Clearance to mechanical air supply inlet Inch 72 36 in. above if within 10 feet horizontally L Clearance above paved sidewalk or paved driveway located on public property Inch 84 ³ ) * M Clearance under veranda, porch deck or balcony Inch 12 ⁴ ) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 4 of 6

Required other than direct vent terminal clearances (single pipe penetration) 6720608836-23.1Av Clearance Data Item Description Value Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony Inch 12 12 B Clearance to window or door that may be opened Inch 36 4 feet below or to side of opening; 1 foot above opening C Clearance to permanently closed window Inch * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Inch * * E Clearance to unventilated soffit Inch * * F Clearance to outside corner Inch * * G Clearance to inside corner Inch * * H Clearance to each side of center line extended above meter/ regulator assembly 36 in. within a height 15 feet above meter/ regulator assembly I Clearance to service regulator vent outlet Inch 36 * J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other application Inch 36 * 4 feet below or to side of opening; 1 foot above opening K Clearance to mechanical air supply inlet Inch 72 36 in. above if within 10 feet horizontally L Clearance above paved sidewalk or paved driveway located on public property Inch 84 ³ ) 84 M Clearance under veranda, porch deck or balcony Inch 12 ⁴ ) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 5 of 6

Water Heating Capacity Curve 13 12 11 10 9 8 Flow 7 Rate (GPM) 6 5 4 3 2 1 0 10 20 30 40 50 60 70 80 90 Temperature rise ( F) 100 110 * 35 F capacity is based on installation with a mixing valve to overcome typical pressure loss through the water heater and system. Water Heating Capacity Data Temperature Rise ( F) Flow Rate (GPM) 35 12.1 45 9.4 55 7.7 65 6.5 75 5.6 90 4.7 100 4.2 Tankless Components 1 10 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 Components Legend 1 Exhaust temperature sensor 2 Condensing heat exchanger 3 Heat exchanger 4 Ionization sensor 5 Primary fan (Mixer) 6 LCD display 7 On/Off button 8 Reset button 9 Program button 10 Flue gas limiter 11 Heat exchanger overheat sensor (ECO) 12 Ignition electrodes 13 Observation window 14 Backflow temperature sensor 15 Secondary air fan 16 Gas valve 17 Condensate trap 18 Control unit 19 Up button 20 Down button 21 LED 6 of 6