FLAT FLAME AND EXCESS AIR BURNERS

Similar documents
EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

PACKAGED METALLIC BURNERS

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

Burners. Long flame burners Nozzle Mix NM - (E3501 rev /05/2015)

Burners. Monoblock free flame burners EPB (E3007 rev /07/2016)

Burners. Monoblock free flame burners EPB (E3007 rev /11/2017)

Burners. Self-recuperative burners high speed free flame REKO-SIK-NxT-FF (E3901FN rev /02/2018)

Burners. Self-recuperative burners high speed free flame REKO-SIK-FF (E3901F rev /08/2015)

SELF - RECUPERATIVE BURNERS HIGH SPEED FREE FLAME REKO-SIK-FF. E3901FF rev /05/2009.

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

INDITHERM. Low temperature gas burners

NMC Nozzle Mix Gas/Oil Combination Burners

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

INDITHERM. Low temperature gas burners

"HC" AIRFLO. In-duct firing line burner

ESA Pyronics International R&D test center

MULTIPLEX SELF RECUPERATIVE gas burner

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

DELTA-TE III. Nozzle-mix line burner

NMG NOZZLE MIX GAS BURNERS

OPERATING AND MAINTENANCE MANUAL

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

INDUSTRIAL MICRODIFFUSION OIL BURNERS

Self-recuperative burner for gas

SULPHUR RECOVERY UNIT

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Eclipse RatioMatic Burners

1 - High-velocity gas burners

Design Guide /12/2008. Eclipse RatioAir Burners RA Series Version 1

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Specifications of MULTIFIRE burners

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

ECLIPSE INFORMATION GUIDE

LINDOFLAMM thermal engineering.

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Electronics. Microprocessor operated burner control device ESA ESTRO (E7014 rev /11/2009)

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

Specifications of V-Line burners

"NP" & "RG" AIRFLO. In-duct firing line burner

Design Guide No /01. RatioMatic Burners. RM Series Version 3.10

Electronics. Burner control and flame detector for permanent and not-permanent operation ESA REFLAM-H (E7802 rev /04/2017)

26 Mesh Belt Brazing Annealing Furnace. Continuous Mesh Belt Brazing Furnace

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Burners Flares Incinerators Vapor Combustion

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Control valve S11T. Pilot burner ZT. Control valve S11T

EQUIPMENT GLASS LEVEL MEASURING SYSTEMS STIRRERS BOOSTER BURNERS THROAT BOOSTER BUBBLERS

Type CG Series Forced Draft Gas Burner

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

PBG PACKAGED GAS BURNER

Eclipse AirHeat Burners

MICROPROCESSOR OPERATED BURNER CONTROL DEVICE ESA ESTRO SERIE

Indirect gas-fired air heater

F900 SERIES GAS CHARGRILL G9440, G9460, G9490, G User, installation and servicing instructions T Read these instructions before use

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

INFRA-RED BURNERS DESCRIPTION USES MODEL: 3207

CEMENT KILN GAS/OIL BURNER

Steam Fundamentals. (in heating & processing applications)

Distributed By: M&M Control Service, INC

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

BG2000S PRE-MIX GAS BURNER

Eclipse AirHeat Burner

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

Series LV AIRFLO. In-duct firing line burner

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

SHP High Pressure Radiant Gas Brooder Series

Waste/Multi Oil Boilers from Flexiheat

GP COMBUSTION EQUIPMENT INC 100 Sheldon Dr., Units 16/17 Cambridge, Ontario N1R 7S7. Model C Forced Draft Burners. Natural Gas or Propane MODEL C10

High Performance Diesel Fueled Cabin Heater. Abstract

MONOBLOCK NG SERIES GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

15 20 kw kw kw

QRA10... QRA53... QRA55...

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

Eclipse Self-Check UV Scanner

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Model 601CRD Oil Burner

FIREYE FLAME SCANNERS

INSTALLATION AND OPERATION MANUAL FOR 2 STAGE RIELLO BURNER ADDENDUM TO ( Mo 437 manual )

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Document code: 1 (10) Issuing date: Status:

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Installation Instructions

Single stage operation oil burner

WHU WATER HEATING UNITS. GENERAL MANUAL MODEL KEY. June 2007 WHU WATER HEATING UNITS

V-Line. Nozzle-mix line burner

OWNER S MANUAL FOR BARBECUE GAS GRILL

P23 MELT CONFINED SPACE LOG

RETROFIT APPLICATIONS ONLY

Transcription:

FLAT FLAME AND EXCESS AIR BURNERS SIDEWINDER - SW SERIES FEATURES Bulletin E303 rev04 31/01/00 Mixer body: cast iron G2 Plate: cast iron G2 Gas tube: AISI304 Pre-heated air: up to 40 Suitable for different types of gas: CH4 /L.P./propane/etc. Standard refractory block, max. temp.: 170 C Capacity range: to 100 kw Excellent flame stability: excess air excess fuel on ratio firing Low NO X level. Wall mounting flanges to fasten the block holder to the furnace shell are threaded to allow for positioning of accessories: pilot burner, flame detectors (electrodes or UV scanners), peepsight. Separated air and gas inlets, mixing at discharge point, no flashback. F303I01 Cap annealing furnaces. Reverberatory furnaces. Aluminium melting furnaces. Zinc melting furnaces. Cone and pit furnaces. Billets reheating furnaces. APPLICATIONS F303I02 Headquarters Esa S.r.l. Via E. Fermi 40 I-2403 Curno (BG) - Italy Tel. +39.03.6227411 - Fax +39.03.6227499 esa@esacombustion.it - www.esapyronics.com International Sales Pyronics International S.A./N.V. Zoning Ind., 4ème rue B-6040 Jumet - Belgium Tel +32.71.26970 - Fax +32.71.26979 marketing@pyronics.be

Bulletin E303 rev04 31/01/00 DESCRIPTION Sidewinder gas burners are nozzle-mixing units with a high velocity, spinning, air flow. The swirling air stream produces an anticlockwise vortex inside the refractory block. Gas enters the vortex, mixing rapidly, producing intense combustion. The inverted parabolic shape of the burner block port works with the vortex to pull flames flat to the furnace wall at firing rates and mixtures. Maximum furnace temperatures are obtained at high-fire with stoichiometric air and gas flows. Excess air operation allows for obtaining quite cold flame temperatures without changing the volumes of the fuel gas. INSTALLATION Sidewinder gas burners may be installed to operate in any position. Wall mounting flanges are available to fasten the block holder to the furnace shell. Lifting eye-bolt hangers are available for furnace roof suspension installations. The inside flared face of the refractory block must be flush with the interior furnace wall. The furnace refractory should be set to leave 12. mm on all sides of the block. This space should be packed with flexible, refractory, ceramic fibre protected by 20 mm of refractory concrete on all sides to allow for expansion of the walls. Flexible connectors are recommended for air and gas connections at the burner to allow slight movement or misalignment of piping and are required when pre-heated air is involved. Air and gas connections are Pyronics standard threaded, or welding flanged type. They may rotate by 90. IGNITION AND FLAME DETECTION Sidewinder gas burners must be ignited at low fire. They can be ignited with a blast pilot, P86PBST, or electrode DSE. The pilot burner should be cut off after the ignition of the main burner therefore flame detection must be carried out by UV-scanners placed in an anticlockwise position as compared to the pilot burner. Flame detection systems are required on all burners operating at furnace temperatures below 70 C. Catalog No. SW- Pilot burner ignition Electrode ignition Ignition Detection Ignition Detection P86PBST P86PBST P86PBST / 6EN-10 * / 6EN-10 * / 6EN-10 * / 6EN-10 * / 6EN-300 * / 6EN-300 * / 6EN-300 * / 6EN-300 * DSE-6 DSE-7 DSE-7 DSE-7 DSE-8 DSE-8 (not available) (not available) (not available) (not available) (*) In most cases, we suggest you to make flame detection through UV- scanner. In some particular cases, it is possible to use continue pilot burner with detection electrode. 2/8

Bulletin E303 rev04 31/01/00 CAPACITY TABLE SW- 100 0 Air pressure at the burner (mbar) 10 1 1 10 0 100 00 1000 000 10000 Capacity (kw) G303I01 CAPACITY TABLE Catalog no. 0.7 kw with different burner air inlet pressure (mbar) * 17.6 3.2 2.8 70.4 Recommended pipe runs for each burner Air Gas 4 18 26 32 37 1.1/2 3/4 7 34 47 9 67 1.1/2 3/4 9 47 66 82 94 2 1 19 92 130 3 18 2.1/2 1" SW- 29 147 207 2 293 3 1.1/2 37 18 261 32 369 4 1.1/2 73 366 64 733 6 2.1/2 147 733 1031 1289 146 8 3 Ratio :1 Ratio 7:1 Ratio 8.:1 Ratio 10:1 Turndown capability from various air pressures at burner * Burner ratings achieved with: 26 mbar gas pressure to ratio regulator (BZR); bleed loader set at 1 mbar (2TDL-B); balanced combustion chamber pressure; natural gas or L.P. 3/8

Bulletin E303 rev04 31/01/00 FLOW CHART (on ratio operation) Pos. Model identification 1 2 3 4 6 7 8 9 10 11 12 13 14 1 Gas ball valve Balanced zero regulator Impulse line Motorized air butterfly valve Electric control Gas ball valve at each burner Main burner safety solenoid gas valve Orifice flow meter for P gas Orifice flow meter for P air Manual air butterfly valve Flat flame burner Pilot burner Pilot burner safety solenoid gas valve Ignition transformer Flame detection UV-scanner D303I01 4/8

Bulletin E303 rev04 31/01/00 FLOW CHART (excess air) Pos. 1 2 3 4 6 7 8 9 10 11 12 13 14 Model identification Gas ball valve Motorized butterfly air valve Electric control Gas ball valve at each burner Main burner safety solenoid gas valve Orifice flow meter for P gas Orifice flow meter for P air Manual air butterfly valve Flat flame burner Pilot burner Pilot burner safety solenoid gas valve Ignition transformer Flame detection UV-scanner D303I02 /8

DIMENSIONS D303E03 Bulletin E303 rev04 31/01/00 6/8 Catalog no. SW-.1/2 Pilot UV-EN Peepsight A G-2 DN6 DN80 DN100 DN10 DN10 B G-2.1/2 G-3 G-3 C mm 222 394 394 394 464 464 464 464 64 D mm 24 430 430 430 08 08 08 08 610 E mm 286 286 286 36 36 36 36 406 F mm 178 343 343 343 419 419 419 419 33 G mm 14 H mm 210 238 238 238 308 308 308 J mm 184 213 213 213 283 283 283 K mm L mm 9 M mm 83 83 83 83 111 111 140 N mm 121 149 149 19 17 17 191 203 203

Bulletin E303 rev04 31/01/00 BURNER SELECTION TABLE Catalog no. Maximum pilot mix. pressure with max main air to burner (mbar) Max % excess air - 70 mbar with pilot without pilot Approx. flame diameter on ratio at maximum rating (mm) 7% aeration with maximum air at burner Minimum burner spacing (on ratio) between burners (mm) burner to load - min. (mm) SW- 2, 6,3 6,3 7, 8,7 1 1 1200 100 600 900 700 40 700 400 300 400 600 60 70 900 100 1800 600 800 920 1200 1400 2300-610 910 1000 110 1400 1800 2100 300 300 300 610 NOTE Flame lenght are approximate, referred to burner feeded with natural gas, free air, working at stoichiometric ratio and at nominal capacity. when two different sizes of burners are mounted adjacent to each other, minimum spacing for larger burner must be used. 7/8

Bulletin E303 rev04 31/01/00 ORDERING CODES - BURNER SW - - - MODEL 1 2... (see capacity table)... MOUNTING PLATE WITH PLATE WMF WITHOUT PLATE WMF (please write in detail) GAS AJUSTER With Gas Adjuster Without Gas Adjuster GA F ORDERING CODES - REFRACTORY BLOCK ONLY SW - - BH - MODEL 1 2... (see capacity table)... MOUNTING PLATE WITH PLATE WMF WITHOUT PLATE WMF (please write in detail) NOTE: Based on the company s policy aimed at a continuous improvement on product quality, ESA-PYRONICS reserves the right to bring changes to the technical characteristics of this device without previous notice. Our catalog updated to the latest version is available on our web site www.esapyronics.com and it is possible to download modified documents WARNING: When operating, this combustion system can be dangerous and cause harm to persons or damage to equipment. Every burner must be provided with a protection device that monitors the combustion. The installation, adjustment and maintenance operations should only be performed by trained and qualified personnel. 8/8