LAARS MIGHTY THERM High Efficiency Boilers and Volume Water Heaters The Ideal Replacement Boiler % Thermal Efficiency Straight Forward, Easy to Use Controls - 000 MBH s Industry Leading Low NOx, ppm Indoor/Outdoor Construction
MIGHTY THERM Mighty Therm Features: Applications for hydronic heating or domestic hot water % Thermal efficiency Industry leading low NOx, less than ppm -Stage firing Immune to thermal shock down to F Operates in altitudes up to,000 feet Ambient temperatures from -40 F to +0 F Tolerant of glycol systems Waterways able to operate in a maximum water hardness of gpg Hydronic models supply temps from 1 F to 0 F Volume water heater models supply temps from 1 F to 00 F Gas supply right or left side (field convertible) Maintains efficiency and low NOx levels at low and high fire Optional factory-mounted pump sized for heat exchanger, feet of pipe and 3 elbows total pressure drop Fan-assisted combustion system 0vac, 60 Hz single phase power External staging control connections May be ordered with left or right-hand piping connection Extremely durable construction Modular construction: burner trays, gas train, blower assembly Glass-lined cast iron or bronze headers Heat exchanger uses efficient finnedtube design Lightweight insulation Compliant end-walls to accommodate thermal expansion Non-ferrous waterways to meet standards for volume water heaters Backed by LAARS warranty and superior customer service Extremely flexible venting Category III (horizontal) venting, up to 50 feet with 3 elbows, without additional fans Fan-assisted category I venting with standard B-vent Combustion air can be taken from room, or ducted to the unit from the outside Extremely easy maintenance Heat exchanger is removable from top, back or front Washable air filter Wiring terminal strip makes electrical troubleshooting easy Easy access to ignitor via special service panel Easy-to-service burner assembly
Mighty Therm Hydronic Boilers or Volume Water Heaters Extremely easy to use For 60 years, the LAARS brand has stood for quality, reliability, and innovation in heating system design. Mighty Therm builds on that tradition with an outstanding line of commercial boilers/heaters designed for today s most demanding indoor and outdoor environments. The line of fan-assisted, modular boilers and water heaters from LAARS ranks among the industry s most versatile and environmentally friendly commercial systems for hydronic and hot water applications. Available in 7 sizes from to 000 MBTU/h, Mighty Therm boilers and water heaters run reliably on natural or LP gas and deliver efficiency levels up to %. The systems are also among the greenest in the industry with NOx emissions below ppm. The Mighty Therm has been specifically designed to meet the needs of the replacement market by offering simple and straightforward controls with -stage firing. Mighty Therm boilers and water heaters feature convenient, modular construction that separates the burner trays, gas train, and blower assembly. All models use lightweight insulation, glass-lined cast iron or bronze headers, and non-ferrous waterways. The tube heat exchanger design uses finned tubing for the quickest and most efficient heat transfer and the water heater meets the ASHRAE.1 standard for efficiency for use with storage tanks. Units are available with copper or cupronickel heat exchanger tubing for use in various water and flow rate conditions, and may include optional factory-mounted pumps sized for the heat exchanger and feet of piping. With superior overall construction and high-efficiency combustion, Mighty Therm can cut fuel costs significantly compared to conventional water heating systems, and the savings can amount to thousands of dollars over the life of the equipment. Extremely versatile Water connections may be ordered to accommodate left or right side piping. Gas can be piped to either the left or right side of the unit. The sealed combustion system is fan-assisted and uses either ambient room air, or air from the outside ducted directly to the unit. This allows the Mighty Therm to be vented as a Category I or Category III appliance. Category I fan-assisted appliances allow for smaller diameter vents than natural draft units, but can still be vented with standard B-vent. When Mighty Therm is vented horizontally, as a Category III appliance, it uses AL-4C stainless steel. It may be vented horizontally up to 50 feet with three elbows without the addition of external vent fans and every unit has a long-lasting, washable air filter to keep the burners clean, ensuring long life. Extremely easy to maintain Mighty Therm features modular burner trays to ensure perfect alignment of orifices and burners, gas manifolds mount on the burner flange, and the burner flanges seal to the air box. In addition, the entire gas train can be easily removed and the heat exchanger lifts out from the top, front, or back of the unit. The air filter is a breeze to clean...just wash it with soap and water. Extremely rugged All Mighty Therm water heater/boilers are built to operate effectively at up to,000 feet, in harsh environments from -40 to +0 F. The boilers can be used with up to a 50:50 glycol to water mix and waterways can operate in water with a hardness up to gpg. All units feature compliant end walls to accommodate thermal expansion and the heat exchanger is designed to withstand thermal shock down to F. The Mighty Therm is the easy choice. With high efficiency, operating costs are minimized. Mighty Therm s performance and low maintenance delivers the savings!
Mighty Therm Sizing Data Indoor Model Input MBH Input kw Output MBH Output kw Boiler (MTH) Combustion Efficiency (%) Boiler (MTH) Thermal Efficiency (%) Water Heater (MTV) Thermal Efficiency (%) Gas Connection inches Water Connection inches Approx. Shipping Weight* lbs. kg 00 10 1 50 000 1,0 1, 1, 1, 7 0 3 366 440 513 56 4 63 4 1,064 1,77 1,4 1,701 1 17 3 371 436 4.0.0.0.1.1.1.1.0.0.0.... 1 1 /4 1 1 /4 1 1 / 1 / 1 / 1 / 1 / 1 / 4 505 615 675 760 55 13 7 6 345 375 434 NOTE: 1. Input and output must be derated 4% per 00 feet above sea level when installed above 000 feet altitude.. Dimensions are nominal. 3. For other boiler ratings: Boiler Horsepower: HP = Output Radiation Surface: EDR sq. ft. = Output 33,475 150 *Add approximately 55 lbs. ( kg) for pump-mounted units. MTH (Boiler) Temperature Rises in Degrees 00 10 1 50 000 0 F 43 1.7 64 3.3 5.0 6.1.0 11 C 161 31 40 43 0.5 1.0 1.5.5 F 34 51 11 136.3 3.6 6.1 7..5.5 C 13 3 36 451 515 0.3 1.. 3. 3. F 43 57 71 113 0. 1.7 3.1 4.7 5.5.4.4 C 7 161 3 375 4 0.3 0.5 0. 1.4 1.7.6 3. 35 F 36 4 61 73 7. 3.4 4. 5..3 1 C 13 76 3 3 0. 0.4 1.0 1.3 1..5 MTV (Water Heater) 00 10 1 50 000 GPM 0 Feet 3.5 6.0 6.1 6.3 6.5 6.7.0 HARD WATER NORMAL WATER SOFT WATER Rise F 1 33 lpm 4 m 1. 1. 1..0.0 Rise C 5 13 16 1 GPM 1 NOTE: Headloss () shown is for the Mighty Therm heat exchanger only. Feet.3 3.6 3. 3. 4.0.0 Rise F 13 1 31 3 44 lpm 4 m 0. Rise C 7 1 GPM 45 45 45 1 Feet 1..1.3 3. 3. 4.0.0 Rise F 1 3 31 3 44 lpm 0 0 0 4 m 0.5 0.6 Rise C 16 1 1 Recovery Data Temperature Rises in Degrees 00 10 1 50 000 40 F 76 115 4 31 37 4464 50 C 41 73 63 054 464 5 174 50 F 0 153 03 51 61 3571 407 C 37 57 7705 643 11571 13 1541 60 F 0 77 16 6 51 76 33 33 C 3 4 641 036 643 110 0 70 F 7 4 56 1 17 51 3 C 755 4136 5504 65 643 1 0 F 63 57 74 154 113 3 50 44 C 11 361 416 607 73 43 637 F 567 1 113 01 66 50 C 3 3 41 5357 64 7 66 0 F 5 766 1 76 1531 6 040 56 C 1 5 33 41 576 6 77 0 F 4 63 4 63 76 00 67 C 1607 13 311 401 41 56 64 0 F 364 547 7 11 3 76 57 7 C 137 0 75 3444 4133 41 5507 NOTE: = gallons per hour, = Liters per hour. Electrical Data Model Boiler/Heater Pump Delay Connection Rating Blower(s) MTH, MTV Volts Phase Amps Volts Phase Amps -700 00-000 0 Single 15 0 0 Single 15A/1hp Included in boiler circuit
MIGHTY THERM Dimensions A B C D E Air Conn. W Vent Conn. V 00 10 1 50 000 33 3 /4 45 3 /4 57 3 /4 1 /4 7 3 /4 1 /4 3 /4 116 7 3 00 7 3 16 3 /4 3 /4 3 /4 34 3 1 / 44 3 /4 4 3 /4 43 53 73 7 0 113 7 6 1 / 6 1 / 6 1 / 1 /4 1 /4 1 /4 1 /4 6 6 6 6 1 / 1 / 0 3 3 3 3 6 15 0 0 0 36 36 NOTE: Dimensions shown in inches cm.
Litho in U.S.A. 0 Industrial Way, Rochester, NH 0367 603.335.60 FAX 603.335.3355 (Headquarters) 1355 Kuehner Drive, Simi Valley, CA 63 00.0.76 FAX 00.55.153 (Sales, Service) 16 Sismet Road, Mississauga, Ontario, Canada L4W 1W 5.3.00 FAX 5.366.01 www.laars.com Laars Heating Systems Co. 1605 Document 13A