LAARS MIGHTY THERM 2. High Efficiency Boilers and Volume Water Heaters

Similar documents
LAARS PENNANT. Economical efficiency for greater savings

Boiler & Water Heater

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Get The Edge Over The Competition with The Summit

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

MASCOT Quick Setup Guide

DOM-5. Domestic Hot Water Heaters & Boilers

FXLF-9. High Efficiency Water Heaters and Boilers

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Date: Project #: Engineer: Prepared By: Bid Date:

Boilers Variable Fire Boilers

Raypak Residential Products

High Efficiency Commercial Gas Water Heaters

Domestic Hot Water Heaters and Boilers FTIIIC-6

CONDENSING HIGH EFFICIENCY BOILERS

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

G315/6 Cast Iron Boiler

Now Available with PVC & Polypropylene Vent Configurations

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

FXLF-4. High Efficiency Water Heaters and Boilers

Residential/Commercial Gas Condensing Tankless Models

G315/5 Cast Iron Boiler

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

G515/7 Cast Iron Boiler

G615/11 Cast Iron Boiler

Heaters & Heat Pumps. Heaters and Heat Pumps. Heaters and Heat Pumps for Swimming Pools and Spas

Residential Gas Tankless Water Heater

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

HEATERS AND HEAT PUMPS HEATERS & HEAT PUMPS HEATERS AND HEAT PUMPS FOR SWIMMING POOLS AND SPAS

Hydronic Air Handler Powered by Tankless Technology

Proudly assembled in U.S.A

Proudly assembled in U.S.A

Product Data BW9 WATER BOILER SERIES B

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Peerless Boilers. Series MI. Residential Gas Boilers

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

FINNED WATER-TUBE POOL HEATERS

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

RG7D 1-Stage Heat Series

Commercial Gas Water Heaters

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Tankless Condensing High Efficiency Water Heaters

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

TECHNICAL SPECIFICATIONS

DIVISION FINNED WATER-TUBE BOILERS

Hydronic Air Handler Powered by Tankless Technology

Mighty Venter Power Vent System

Proudly assembled in U.S.A

Industrial Applications

NO ONE PUTS MORE INTO THEIR POOL HEATERS

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

iq251, Gen II Submittal Data

iq1001, Gen II Submittal Data

DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

The Brute MagnaTech. A Perfect Balance of Size, Form, and Function. Commercial, High Efficiency Condensing Boiler and Volume Water Heater

Commercial Boilers and Domestic Water Heaters APG-5

Section 12 - REPLACEMENT PARTS Use only genuine LAARS replacement parts.

Advanced Heating and Hot Water Systems

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

Less Than.25% Lead Proudly Assembled in the U.S.A

Concrete Applications

Commercial Tankless Rack System

G215 G315 Cast Iron Residential Boilers

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

The WCGH High Efficiency Commercial Water Heater with Storage Tank

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

Commercial Tankless Rack System

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

TECHNICAL SPECIFICATIONS

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Less Than.25% Lead Proudly Assembled in the U.S.A

Transcription:

LAARS MIGHTY THERM High Efficiency Boilers and Volume Water Heaters The Ideal Replacement Boiler % Thermal Efficiency Straight Forward, Easy to Use Controls - 000 MBH s Industry Leading Low NOx, ppm Indoor/Outdoor Construction

MIGHTY THERM Mighty Therm Features: Applications for hydronic heating or domestic hot water % Thermal efficiency Industry leading low NOx, less than ppm -Stage firing Immune to thermal shock down to F Operates in altitudes up to,000 feet Ambient temperatures from -40 F to +0 F Tolerant of glycol systems Waterways able to operate in a maximum water hardness of gpg Hydronic models supply temps from 1 F to 0 F Volume water heater models supply temps from 1 F to 00 F Gas supply right or left side (field convertible) Maintains efficiency and low NOx levels at low and high fire Optional factory-mounted pump sized for heat exchanger, feet of pipe and 3 elbows total pressure drop Fan-assisted combustion system 0vac, 60 Hz single phase power External staging control connections May be ordered with left or right-hand piping connection Extremely durable construction Modular construction: burner trays, gas train, blower assembly Glass-lined cast iron or bronze headers Heat exchanger uses efficient finnedtube design Lightweight insulation Compliant end-walls to accommodate thermal expansion Non-ferrous waterways to meet standards for volume water heaters Backed by LAARS warranty and superior customer service Extremely flexible venting Category III (horizontal) venting, up to 50 feet with 3 elbows, without additional fans Fan-assisted category I venting with standard B-vent Combustion air can be taken from room, or ducted to the unit from the outside Extremely easy maintenance Heat exchanger is removable from top, back or front Washable air filter Wiring terminal strip makes electrical troubleshooting easy Easy access to ignitor via special service panel Easy-to-service burner assembly

Mighty Therm Hydronic Boilers or Volume Water Heaters Extremely easy to use For 60 years, the LAARS brand has stood for quality, reliability, and innovation in heating system design. Mighty Therm builds on that tradition with an outstanding line of commercial boilers/heaters designed for today s most demanding indoor and outdoor environments. The line of fan-assisted, modular boilers and water heaters from LAARS ranks among the industry s most versatile and environmentally friendly commercial systems for hydronic and hot water applications. Available in 7 sizes from to 000 MBTU/h, Mighty Therm boilers and water heaters run reliably on natural or LP gas and deliver efficiency levels up to %. The systems are also among the greenest in the industry with NOx emissions below ppm. The Mighty Therm has been specifically designed to meet the needs of the replacement market by offering simple and straightforward controls with -stage firing. Mighty Therm boilers and water heaters feature convenient, modular construction that separates the burner trays, gas train, and blower assembly. All models use lightweight insulation, glass-lined cast iron or bronze headers, and non-ferrous waterways. The tube heat exchanger design uses finned tubing for the quickest and most efficient heat transfer and the water heater meets the ASHRAE.1 standard for efficiency for use with storage tanks. Units are available with copper or cupronickel heat exchanger tubing for use in various water and flow rate conditions, and may include optional factory-mounted pumps sized for the heat exchanger and feet of piping. With superior overall construction and high-efficiency combustion, Mighty Therm can cut fuel costs significantly compared to conventional water heating systems, and the savings can amount to thousands of dollars over the life of the equipment. Extremely versatile Water connections may be ordered to accommodate left or right side piping. Gas can be piped to either the left or right side of the unit. The sealed combustion system is fan-assisted and uses either ambient room air, or air from the outside ducted directly to the unit. This allows the Mighty Therm to be vented as a Category I or Category III appliance. Category I fan-assisted appliances allow for smaller diameter vents than natural draft units, but can still be vented with standard B-vent. When Mighty Therm is vented horizontally, as a Category III appliance, it uses AL-4C stainless steel. It may be vented horizontally up to 50 feet with three elbows without the addition of external vent fans and every unit has a long-lasting, washable air filter to keep the burners clean, ensuring long life. Extremely easy to maintain Mighty Therm features modular burner trays to ensure perfect alignment of orifices and burners, gas manifolds mount on the burner flange, and the burner flanges seal to the air box. In addition, the entire gas train can be easily removed and the heat exchanger lifts out from the top, front, or back of the unit. The air filter is a breeze to clean...just wash it with soap and water. Extremely rugged All Mighty Therm water heater/boilers are built to operate effectively at up to,000 feet, in harsh environments from -40 to +0 F. The boilers can be used with up to a 50:50 glycol to water mix and waterways can operate in water with a hardness up to gpg. All units feature compliant end walls to accommodate thermal expansion and the heat exchanger is designed to withstand thermal shock down to F. The Mighty Therm is the easy choice. With high efficiency, operating costs are minimized. Mighty Therm s performance and low maintenance delivers the savings!

Mighty Therm Sizing Data Indoor Model Input MBH Input kw Output MBH Output kw Boiler (MTH) Combustion Efficiency (%) Boiler (MTH) Thermal Efficiency (%) Water Heater (MTV) Thermal Efficiency (%) Gas Connection inches Water Connection inches Approx. Shipping Weight* lbs. kg 00 10 1 50 000 1,0 1, 1, 1, 7 0 3 366 440 513 56 4 63 4 1,064 1,77 1,4 1,701 1 17 3 371 436 4.0.0.0.1.1.1.1.0.0.0.... 1 1 /4 1 1 /4 1 1 / 1 / 1 / 1 / 1 / 1 / 4 505 615 675 760 55 13 7 6 345 375 434 NOTE: 1. Input and output must be derated 4% per 00 feet above sea level when installed above 000 feet altitude.. Dimensions are nominal. 3. For other boiler ratings: Boiler Horsepower: HP = Output Radiation Surface: EDR sq. ft. = Output 33,475 150 *Add approximately 55 lbs. ( kg) for pump-mounted units. MTH (Boiler) Temperature Rises in Degrees 00 10 1 50 000 0 F 43 1.7 64 3.3 5.0 6.1.0 11 C 161 31 40 43 0.5 1.0 1.5.5 F 34 51 11 136.3 3.6 6.1 7..5.5 C 13 3 36 451 515 0.3 1.. 3. 3. F 43 57 71 113 0. 1.7 3.1 4.7 5.5.4.4 C 7 161 3 375 4 0.3 0.5 0. 1.4 1.7.6 3. 35 F 36 4 61 73 7. 3.4 4. 5..3 1 C 13 76 3 3 0. 0.4 1.0 1.3 1..5 MTV (Water Heater) 00 10 1 50 000 GPM 0 Feet 3.5 6.0 6.1 6.3 6.5 6.7.0 HARD WATER NORMAL WATER SOFT WATER Rise F 1 33 lpm 4 m 1. 1. 1..0.0 Rise C 5 13 16 1 GPM 1 NOTE: Headloss () shown is for the Mighty Therm heat exchanger only. Feet.3 3.6 3. 3. 4.0.0 Rise F 13 1 31 3 44 lpm 4 m 0. Rise C 7 1 GPM 45 45 45 1 Feet 1..1.3 3. 3. 4.0.0 Rise F 1 3 31 3 44 lpm 0 0 0 4 m 0.5 0.6 Rise C 16 1 1 Recovery Data Temperature Rises in Degrees 00 10 1 50 000 40 F 76 115 4 31 37 4464 50 C 41 73 63 054 464 5 174 50 F 0 153 03 51 61 3571 407 C 37 57 7705 643 11571 13 1541 60 F 0 77 16 6 51 76 33 33 C 3 4 641 036 643 110 0 70 F 7 4 56 1 17 51 3 C 755 4136 5504 65 643 1 0 F 63 57 74 154 113 3 50 44 C 11 361 416 607 73 43 637 F 567 1 113 01 66 50 C 3 3 41 5357 64 7 66 0 F 5 766 1 76 1531 6 040 56 C 1 5 33 41 576 6 77 0 F 4 63 4 63 76 00 67 C 1607 13 311 401 41 56 64 0 F 364 547 7 11 3 76 57 7 C 137 0 75 3444 4133 41 5507 NOTE: = gallons per hour, = Liters per hour. Electrical Data Model Boiler/Heater Pump Delay Connection Rating Blower(s) MTH, MTV Volts Phase Amps Volts Phase Amps -700 00-000 0 Single 15 0 0 Single 15A/1hp Included in boiler circuit

MIGHTY THERM Dimensions A B C D E Air Conn. W Vent Conn. V 00 10 1 50 000 33 3 /4 45 3 /4 57 3 /4 1 /4 7 3 /4 1 /4 3 /4 116 7 3 00 7 3 16 3 /4 3 /4 3 /4 34 3 1 / 44 3 /4 4 3 /4 43 53 73 7 0 113 7 6 1 / 6 1 / 6 1 / 1 /4 1 /4 1 /4 1 /4 6 6 6 6 1 / 1 / 0 3 3 3 3 6 15 0 0 0 36 36 NOTE: Dimensions shown in inches cm.

Litho in U.S.A. 0 Industrial Way, Rochester, NH 0367 603.335.60 FAX 603.335.3355 (Headquarters) 1355 Kuehner Drive, Simi Valley, CA 63 00.0.76 FAX 00.55.153 (Sales, Service) 16 Sismet Road, Mississauga, Ontario, Canada L4W 1W 5.3.00 FAX 5.366.01 www.laars.com Laars Heating Systems Co. 1605 Document 13A