EUROFLAT SERIES TYPES C... S... M...

Similar documents
EUROBOX SERIES TYPES CM... SM... MM...

EUROBOX SERIES TYPES CM...N SM...N MM...N

MICROFLAT SERIES TYPES C.../U T X

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

C Note! LGI16... Burner Controls. Building Technologies

LAE10 LFE10. Use. Series 02

Forced draught gas burner

UV Flame Supervision System

Flame Safeguards LFE10. Building Technologies HVAC Products

LGA... Gas Burner Controls. Building Technologies Division

Flame Safeguards LFE10. Building Technologies HVAC Products

Forced draught gas burner

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

24 VAC Intermittent Pilot Gas Ignition Control

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

CATALOGUE PRODUITS - CSA - CSI - CSM - CSS - CSS2 - P16 - P19 - P20 - P25 - UV DETECTOR

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Oil Burner Controls LOA3... Building Technologies HVAC Products

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

LFL Series Burner Flame Safeguard Control

MMI (40-34) Gas burner safty control

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

24 VAC Direct Spark Gas Ignition

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Operator: Save these instructions for future use!

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

Old documentation - Only for your information! Product is not available anymore!

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Eclipse 90 UV Scanner Model A Version 1

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Gas burner automatic safety control MMI / 811.1

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

MMG Gas burner safety control

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

Oil Burner Controls LMO24... LMO44...

Light oil - kerosene burner

Old documentation - Only for your information! Product is not available anymore!

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Operator: Save these instructions for future use!

SET-2000 Hi Level/Oil

Interrupted Ignition Series Oil Primary Control

LC3000 Level Controller Installation and Maintenance Instructions

Operator: Save these instructions for future use!

OilSET-1000 (12 VDC)

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

Eclipse Self-Check UV Scanner

Use. The burner controls are certified to EN 230 and EN 298.

Oil Burner Controls LMO24... LMO44...

Operator: Save these instructions for future use!

RE-PR3-E-27 3-Phase Panel Mount 27kW

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Infrared Flame Detectors

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

BGH Series Hot Surface Ignition Control

INSTALLATION AND MANINTENANCE INSTRUCTIONS

CUSTOMER SPECIFICATION

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

DATASHEET. Burner control unit FDA 601x

Pilot Burner and Direct Spark Ignition (DSI) Applications with Flame Rectification Sensing

Series 65 Product Guide MAN 3036

DOMESTIC HOT WATER Follow operational sequence

400GL PX (PF) Servicing Instructions. For use in GB and IE PLEASE READ THESE INSTRUCTIONS BEFORE SERVICING THIS APPLIANCE

50A Integrated Furnace Control

IRIS IP65 IRIS UNISCAN APPLICATION MANUAL

New Power Vented Rheem FVIR Tanks

Quickheat 30 weather compensated boiler control

Figure 10 or Figure 6

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Oil Burner Controls LOA3... Building Technologies Division

Burner control unit BCU 370

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

SET Installation and Operating Instructions. Level switch for one sensor

Heating Equipment. gas boilers RX GB. installation and servicing instructions

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

INSTALLATION AND OPERATION MANUAL

Brivis Service Manual

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Transcription:

EUROFLAT SERIES TYPES C... S... M... AUTOMATIC CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN APPLICATION The electronic systems of this range are suitable to control gas atmospheric burners with or without fan in the combustion circuit for non-permanent operation.. The controllers of this series can be provided with nonvolatile or volatile lockout; in the first version restarting the controller from a safety lockout condition can be accomplished only by a manual reset of the system. In the electric restart versions restarting the controller from a safety lockout condition can be achieved only by the interruption of the power supply and its subsequent restoration. This series of controllers can be mounted in: - combi boilers - heating boilers - warm air generators - radiant tube heaters - water heaters Due to the models technical and constructive features and to their variety they can be used also for the automation of ovens, cookers, stoves and generally in gas firing installations with atmospheric burner. FEATURES Table 1 shows the main features of this series Other important features are: EC certification type (CE PIN 0694BR1154) in accordance with Gas Appliance Directive 90/396 and the following amendment of Directive 93/68; In accordance with EN 298 (European standard for programming and flame control automatic systems of gas burners); Flame monitoring based on the rectification property of the flame (ionization); two independent safety contacts in series on the gas valve output (manual reset models); electrical service life at max. declared loading > 250.000 operations; inbuilt ignition device completely of solid state design and high efficiency; auxiliary contact for low power ignition or main gas valve control for intermittent pilot systems (this contact is not isolated from the main supply voltage by reinforced isolation, therefore the relay contact is not suitable to control SELV circuits Safety Extra Low Voltage, e.g. 24V). 3993_r02 1/7

TABLE 1 Manual reset Electric reset BURNER Single flame Dual flame Atmospheric without fan Atmospheric with fan OPTION Auxiliary contact(1) Single electrode EN298:1993 compliant EN298:2003 (2) compliant Classification code according to EN 298 (3) CM11 * * * * * AMCLXN CM31 * * * * * FMCLXN CM32 * * * * * * FMCLXN SM11 * * * * * * AMCLXN MM51 * * * * * * * AMCLXN MM32 * * * * * * * FMCLXN CE11 * * * * AMCVXN CE31 * * * * FMCVXN CE32 * * * * * FMCVXN SE11 * * * * * AMCVXN ME51 * * * * * * AMCVXN ME32 * * * * * * FMCVXN NOTE (1): the auxiliary contact is not a SELV type (Safety Extra Low Voltage, e.g. 24V), therefore it is not suitable to control SELV circuits. (2): the controller is in accordance if EN 298:2003 compliant is written on its label and the option is marked with # (3): flame failure during TS causes spark restoration.. TECHNICAL DATA: Power supply: 230 V 50/60 Hz Upon request: 110-120 V 50/60 Hz Operating temperature range: -20 C +60 C Humidity : max. 95 % at 40 C Protection degree: IP00 Times: - waiting or pre-purge time (TW): 1,5 60 s - start-up safety time (TS): 1,5 60 s - response time in case of flame failure: 1 s The times given on the controller label correspond to the guaranteed values. The actual values can differ slightly from the declared ones, pre-purge and waiting times can be longer and safety time shorter than their nominal values. Internal fuse (versions opt. #): 5 A time-delay External fuse: 3.15 A fast-blow Flame control: The flame detection device makes use of the flame rectification property (ionization); this device is not supplied with protective impedance, therefore the detection electrode is not safe to touch. - Minimum ionization current: 1.2 µa Upon request: 0.5 µa -Recommended ionization current: 3 5 times the minimum ionization current - Cable maximum length : 1 m - Minimum insulation resistance of cable and detection electrode to earth: 50 MΩ - Max. parasitic capacitance of electrode: 1nF - Max. short circuit current: < 200 µa AC - Max. ionization current (230 V 50 Hz): 8µA DC Ignition: - Ignition voltage: 20 kv at 30 pf loading - Spark repetition rate : 25 Hz - Max. cable length: 2 m - Recommended discharge distance : 2-4 mm - Consumption: 2.5 VA - Spark energy: 15 mj Weight: 200 g Controllers for special applications: Upon request it is possible to meet special requirements concerning times, spark repetition rate, minimum ionization current and operating cycle. CONSTRUCTION The plastic container protects the controller against mechanical damage caused by crash, tempering, dust and dirt of external ambient. The PCB dimensions have been reduced by means of a module with surface mounted electronic components. A varistor protects the controller from voltage transients on the mains supply. An inbuilt fuse protects the controller internal relays in case of short circuit on the outputs (valves, fan and lockout signal); this fuse is not accessible, therefore the controller must be protected externally by a fast-blow fuse suitable to the connected load and never exceeding 3,15A OVERALL DIMENSIONS The controllers of the EUROFLAT series can be supplied with different executions but with the same container. The following figure (Fig. 1) shows the overall dimensions of the controllers. Start-up power consumption: - versions without fan 10 VA - versions with fan 12 VA Operating power consumption - versions without fan 7 VA - versions with fan 9 VA Max. contact ratings: Imax M4 SCREW SLOT - Thermostat: 4 A cos ϕ = 0.4 - VG1: 0.5 A cos ϕ = 0.4 - VG2: 0.5 A cos ϕ = 0.4 - Fan: 1 A cos ϕ = 0.4 - Lockout signal: 0.5 A cos ϕ = 1 Fig.1 - Auxiliary contact: 0.5 A cos ϕ = 0.4 Maximum length of external components cables 1 m Internal fuse: 4 A time-delay 2/7 3993_r02

ACCESSORIES The controllers can be supplied with connectors and/or reset push-button (the push-button is to be fitted to the manual reset versions). Do not fit terminals and female connectors of different marks. The following accessories (Fig. 2) can be supplied upon request. RESET BUTTON FEMALE CONNECTOR RESET LOCK-OUT SIG. DRILLING PLAN TERMINALS NEUTRAL Fig.2 CONNECTION Using non reversible connectors with different number of poles makes the connection easy and reliable. One way fast-on connectors of different sizes for ignition and detection electrodes permit their easy installation and replacement. The dual output ignition device allows spark generation on one point (a), two points (b) or between two electrodes isolated from the metal frame of the burner (c), see Fig.3. Fig.3 Regarding the controllers connection, strain reliefs and a sufficient number of earth and neutral terminals should be present in the appliance or in external connection boxes. INSTALLATION DIRECTIONS The controllers are safety devices; guarantee and responsibility of the manufacturer will be debarred if the controllers are tempered with by the user. A regulation lockout must occur every 24 hours in order to allow the controller to check its efficiency (nonpermanent operation systems) The controller must be connected and disconnected without power supply. The controller can be mounted in any position. Avoid exposure to dripping water. A ventilated installation ambient and a quite low temperature ensure the longest life of the controller. Before installing or replacing the controller make sure that its type, code and times are those required. The gas appliance in which the controller is installed must provide adequate protection against the risk of electric shock (at least IP20) ELECTRICAL INSTALLATION The applicable national regulation and European standards (Ex. EN 60335-1/ EN 50165) regarding electrical safety must be respected. Live and neutral should be connected correctly, a mistake could cause dangerous condition, i.e. internal and external protection and safety devices could be inefficient in case thermostats and valves connection cables lose the insulation. Besides, if live-neutral polarity is not respected the controller goes to lockout at the end of safety time. Check cables carefully before starting the system; wrong connections can damage the controller and compromise safety. The earth terminal of the controller, the metal frame of the burner and the earth on the mains supply must be well connected. Take great care while connecting lockout signal and reset button: inverted connections can damage the controller. Avoid putting the detection cable close to power or ignition cables. Use a heat resistant detection electrode well insulated to ground and protected from possible moisture (or water in general). Use an ignition cable as short and straight as possible and keep it far from other conductors to reduce the emission of electromagnetic interference (max. length < 2m and insulation voltage >25 kv). In case of live-neutral networks with unearthed neutral or live-live network (with centre of the star not earthed) the controller can operate correctly by means of a built-in resistor; however, with such networks we recommend to use our step-up transformer type AR1. In the event of bad insulation between phase(s) and earth the voltage on the detection electrode is reduced until it causes the lockout of the controller. CHECKING AT START-UP Always check the controller before the first star-up and also after every overhaul and long period of non operation. Before any ignition attempt make sure that the combustion chamber is free from gas, then make sure that: : If the start-up attempt occurs without gas supply the controller goes to lockout at the end of safety time; When gas flow is interrupted (while the controller is in running state) power supply to gas valve/s is interrupted within 1 second and the controller proceeds to lockout after a recycle; Operating times and cycle are in compliance with the ones declared for the type of the used controller; The level of the flame signal is sufficient, see Fig. 4 for the measuring test; The ignition electrodes are adjusted in the most stable way for a 2-4 mm air spark gap; The intervention of regulators, limiters or safety devices causes a shut down of the controller according to the application type. 3993_r02 3/7

When the flame fails during safety time, the ignition device is activated within one second. The following diagrams are useful to understand how each controller operates. Fig.4 OPERATION At every start the controller proceeds to a self-checking of its own components. During the pre-purge or waiting time (TW) the internal circuit makes a test of the flame signal amplifier. A parasitic flame signal or fault in the amplifier prevents the controller from starting. In the types with fan control, before pre-purge time starts, the controller checks that the air pressure switch contact is in the "no air flow" state. Only if the test is positive the fan is energized and, with the air pressure switch in "air flow" state, pre-purge time begins. At the end of the waiting or pre-purge time the gas valve is power supplied and the ignition device is energized and thus the safety time (TS) begins. If a flame is detected during the safety time the ignition device is inhibited and, in the models where it is provided, the independent auxiliary contact (or the main valve control) will switch from off to flame detected condition. If no flame is detected within safety time, the controller proceeds to lock-out at the end of TS and so the gas valve and the ignition device are switched off while the lock-out signal output is power supplied. CONTROLLER RESET In the manual reset versions when a controller has gone to lockout, a 10 seconds interval should be allowed before attempting to reset; if this time is not observed then it s not possible to reset the system. In general, the reset button must be in sight and in the near vicinity of the appliance. Resetting can occur by means of a conscious manual action and not by means of automatic devices like thermostats or timers. It is allowed to combine the reset button together with the main switch on the appliance. In this case a light alarm will have to be installed. In the electric reset versions, the controller reset is accomplished by interrupting and then restoring the power supply. The independent manual reset function is not included in these models; therefore they must be used only in the appliances where resetting through shut off is allowed by the European standards. Type Options (1) (2) (3) (4) OPT. (5) (6) (7) (8) (9) Type CONTROLLERS DENOMINATION (1) - C: Separate ignition and detection electrodes. S: Separate ignition and detection electrodes and auxiliary contact control. M: One electrode for ignition and flame detection. (2) - M: Manual reset by means of RESET button. E: Electric reset (operation restoring by interrupting power supply). (3) - 1: Version without fan (for open combustion chamber applications). 3: Version with fan (for closed combustion chamber applications). 5: Version with one electrode for ignition and flame detection, without fan and auxiliary contact control. (4) - 1: Version with control of only one valve or valve plus auxiliary contact. 2: Version with 2 valves control. Options (5) - #: Versions in compliance with EN298:2003 (only for XMXX versions). (6) - *: Special versions. Apply to our commercial offices for special requirements. (7) - P: Protection against connection inversion of air pressure switch (only for XX3X versions). (8) - A: Versions with increased output voltage of the ignition device. (9) - 0: Versions with container made of self-extinguishable material class UL-V0. (10) - S: Versions with reduced discharge frequency of the ignition device. Example: CM32 opt. # C Separate ignition and flame detection electrodes M Manual reset by means of RESET button 3 Version with fan (for closed combustion chamber applications ) 2 Version with 2 valves control # Version in compliance with EN298:2003. 4/7 3993_r02

WIRING DIAGRAMS MANUAL RESET VERSIONS TYPE CM11 TYPE CM31 TYPE SM11 TYPE CM32 TYPE MM51 TYPE MM32 THERMOSTAT FAN AIR PRESSURE SWITCH FUSE BURNER LOCK OUT SIGNAL FIRST GAS VALVE SECOND GAS VALVE NOTE: Limit thermostat must be connected in series to the live. 3993_r02 5/7

ELECTRIC RESET VERSIONS TYPE CE11 TYPE CE31 TYPE SE11 TYPE CE32 TYPE ME51 TYPE ME32 THERMOSTAT FAN AIR PRESSURE FUSE SWITCH BURNER LOCK OUT FIRST GAS SECOND GAS SIGNAL VALVE VALVE NOTA: Limit thermostat must be connected in series to the live. 6/7 3993_r02

CYCLE DIAGRAMS MANUAL RESET VERSION TYPE CM11 TYPE CM31 TYPE SM11 MM51 TYPE CM32 MM32 ELECTRIC RESET VERSION TYPE CE11 TYPE CE31 TYPE SE11 ME51 TYPE CE32 ME32 THERMOSTAT FAN AIR PRESSURE SWITCH IGNITION FLAME LOCK OUT FIRST GAS SECOND GAS SIGNAL SIGNAL VALVE VALVE CompATTENTION -> Company Brahma S.p.A. declines any responsibility for any damage resulting from the Customer's interfering with the device. BRAHMA SpA Via del Pontiere,31 37045 Legnago (Vr) Tel. +39 0442 635211 Telefax +39 0442 25683 http:// www.brahma.it E mail: brahma @ brahma.it 07/07/02 Subject to amendments without notice 3993_r02 7/7