INSTALLATION INSTRUCTION

Similar documents
Installation Instructions

6-10 Ton Pack age Unit Low Leak Mod u lat ing Economizer w/ W7220A JADE Con trol In stal la tion In struc tions

Installation Instructions

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

INSTALLATION INSTRUCTIONS MODELS (-)XRD-01RGHAM3 HORIZONTAL AIRFLOW ECONOMIZERS

IN STAL LA TION IN STRUC TION

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MODELS RXRD-01MDDAM3 VERTICAL AIRFLOW ECONOMIZERS

IN STAL LA TION IN STRUC TION

Unitized Energy Recovery Ventilators for use with Carrier Air Conditioning

Wiring Diagrams DIAGRAM INDEX

INSTALLATION INSTRUCTIONS MODELS (-)XRD-01RECAM3, (-)XRD-01RECBM3, (-)XRD-01RCCAM3, & (-)XRD-01RCCBM3 CONVERTIBLE AIRFLOW ECONOMIZERS

Your safety and the safety of others are very important.

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Installation Instructions

Installation Instructions

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

INSTALLATION INSTRUCTIONS

FOSSILFUELKITAXWR02FFA1

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

INSTALLATION, OPERATION & MAINTENANCE IN STRUC TIONS OIL-FIRED WATER HEATERS 72E 361E 541E

VTC / VTH PRODUCT SPECIFICATIONS. ¾ Ton through 2 Tons VERTICAL TERMINAL AIR CONDITIONER AND HEAT PUMP

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Installation Instructions

INSTALLATION INSTRUCTIONS

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

FIRE PROTECTION SYSTEMS

B SERIES ELECTRIC FURNACE

OIL-FIRED WATER HEATERS 72E 361E 541E

Installation Instructions

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

TECHNICAL SUPPORT MANUAL Fan Coils FVM4X B Series

BUILD ING DE SIGN FOR COM MER CIAL BUILD INGS

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

LGB. Control Supplement. Gas fired boiler. Universal Control System. Series 2 Propane gas. Contents

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

The information presented in this manual applies to the 27" negative pressure dryer, both electric and gas models.

Typical Mount Height. Combustion Chamber

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

G21/GSR21 SERIES UNITS LENNOXOEMPARTS.COM

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION IN STRUC TION

USER'S MANUAL/INSTALLATION INSTRUCTIONS

SOLVING PARAFFIN DEPOSITION PROBLEM IN TUBING BY HEATING CABLE APPLICATION

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

ACCESSORY KIT INSTALLATION INSTRUCTION 2PH0852* SERIES ELECTRIC HEAT ACCESSORIES SPECIFICATIONS

INSTALLATION INSTRUCTIONS

Fast Track Troubleshooting

INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH

Schneider Electric Erie T155 Series

Installation Instructions

SUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS. INSTALLATION INSTRUCTION Supersedes: Nothing N3Y (394) MODELS D*SC360 & 480 INSPECTION

United States Patent (19) Dean

AG Series Electric Heaters

INSTALLATION INSTRUCTIONS

SM Field Installed Electric Heat Kit

LGB Gas fired boiler

Slow drying Thermostat What is temperature set at on control. Check for adequate makeup air (1.5 sq. Ft.)

LOW VOLTAGE CONTROL CIRCUIT WIRING

INSTALLATION, OPERATION & QUICK START GUIDE

USER'S MANUAL PGE Single Package Rooftop

DryAire DRYING CABINET

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

FAN POWERED VAV TERMINALS

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

Electronic Air Cleaner


INSTALLATION INSTRUCTIONS MASTER CONTROLLERS MC91AE MC92AE MC93AE MC94AE MC94AEH MC96AEH MC97AE-1

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Installation Instructions

GREEN REFRIGERANT R-410A

Installation Instructions

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Supersedes: N2Y (498) N2Y (799) MODELS B1HH018 THRU THRU 5 TON (12 SEER)

Installation Instructions

Transcription:

INSTALLATION INSTRUCTION I - Ship ping and Pack ing List Pack age 1 of 1 con tains: INSTALLATION INSTRUCTIONS FOR ECONOMIZER USED WITH (B4,B5)SM 090/120 SERIES AIR HANDLER OUTDOOR FRESH AIR FORM # 572D-1210 1 - Economizer As sem bly 1 - Con trols and Wir ing Har ness As sem bly 3 - Wire Nuts 14 - #10 x ½ Check contents for shipping damage. Contact the last carrier immediately if any shipping damage is found. II - Ap pli ca tion Economizers are used with Nordyne (B4,B5)SM Series Air Handlers for automatic sensor-controlled introduction of outdoor air into the system through an electro-mechanically controlled damper. Outdoor air is mixed with the buildings return air to economically improve indoor air quality and aide in reducing energy costs. Economizers can be utilized in either Horizontal or Vertical air handler applications and are easily mounted over the air handler return air and filter frame assembly, The C-7150 Mixed Air Sensor is shipped inside the economizer and must be relocated downstream of the air handler refrigerant coil in accordance with these instructions. Economizer Sup ply / Re turn Duct Con nec tions: INDOOR RETURN AIR INLET ENTHALPY SENSOR 39.75" Wide x 15.63" High (Outside Flange Dimensions) Warning: This kit is to be installed by a qualified service technician in accordance with these instructions and all codes having jurisdiction. Failure to follow these instructions could result in serious injury, property damage, or death. These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this appliance. Some local codes require licensed installation/service personnel for this type of equipment. III - In stal la tion 1. DISCONNECT ALL POWER TO THE UNIT. 2. Install and secure the economizer as shown with the air handler in the Horizontal position (Figure 1) or in the Vertical position (Figure 2) using screws (12) provided in the kit. NOTE: Economizers must be properly supported when installed with this air handler. Support for the economizer is field supplied and the responsibility of the installer to use methods approved by State or Local mechanical building codes having jurisdiction. For Vertical installations, Nordyne Adjustable Support Leg Kit, SKU # 560258 may be used. 3. Connect ductwork to the economizer using flanges provided. DRIVE MOTOR W7212 LOGIC MODULE ELECTRICAL KNOCKOUTS Fig ure 1 - (B4,B5)SM Horizontal Application 1

INSTALLATION INSTRUCTION 4 Remove the economizer control access panel, the air handler motor access panel, and the air handler control panel cover. 5 Remove the electrical knockout on the economizer next to the damper motor and the plastic plug on the air handler panel above the control panel, This will allow routing of the economizer control wiring through a length of 1" conduit, or other equivalent means of wire protection based on State or Local codes which covers 24V Class 2 wiring. 6 Cut and discard wire tie securing control wiring bundle inside the economizer. Remove the two red wires from the C-7150 Mixed Air Sensor and mount the sensor to the divider plate located left of the blower motor assembly as shown in Figure 3 using two screws provided. Important - DO NOT cut other wires. Inspect bundle for damaged connections or loose wires. 7. Route the nine economizer control wires from the economizer quick connect plug through the conduit and into the air handler compartment. Route all wires except for the two red Mixed Air Sensor wires into the control panel through the Low Voltage bushing. 8. Connect the two red wires to the Mixed Air Sensor and secure wires away from the blower and motor components. 9. Nordyne air handlers are designed to work with either A/C or Heat Pump outdoor units. Select the proper wiring diagram for this application on Page 5 and 6 to connect the remaining seven economizer control wires to the air handler. Replace air handler control panel cover and motor access panel. IV - Op er a tion Note: These instructions are written for the economizer to operate with a standard single stage Heat/Cool or Heat Pump thermostat. If 2nd stage mechanical (compressor) cooling is desired a 2 Stage Cool / 1 Stage Heat thermostat is required. A. Cooling Mode, Sequence of Operation (Standard) 1. On a call for cooling, with ambient temperature and humidity above enthalpy control setpoint, the refrigerant system will operate normally, and damper will open to minimum vent position. See Section VI for proper set up and adjustments. 2. On a call for cooling, with outdoor ambient temperature and humidity suitable for cooling, enthalpy control will shift stage one cooling control to outside air. The economizer damper will modulate, mixing outside air with return air, to control supply air temperature to approximately 55 F (13 C). If additional cooling is required, the compressor can be energized through second stage of an optional two stage Cooling thermostat. Refer to wiring diagrams for proper connections. INSTALLATION INSTRUCTIONS FOR ECONOMIZER USED WITH (B4,B5)SM 090/120 SERIES AIR HANDLER ELECTRICAL KNOCKOUTS MOTOR ACCESS PANEL Fig ure 2 - (B4,B5)SM Vertical Application* CONTROL PANEL MIXED AIR SENSOR Fig ure 3 - Mixed Air Sensor Location * Air handler shipped from factory for horizontal application. See air handler installation instructions for conversion from horizontal to vertical application. 2

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTIONS FOR ECONOMIZER USED WITH (B4,B5)SM 090/120 SERIES AIR HANDLER Figure 4 B. Cool ing Mode, Sin gle Enthalpy Con trol (Factory Standard) The C7400A enthalpy control senses both temperature and humidity or the heat content of the outside air. It controls the amount of outdoor air brought into the system. When the heat content of the outside air is below control setpoint, the control modulates outdoor dampers to meet cooling needs of the building. When the heat content rises above control setpoint, the control closes outdoor dampers to minimum position. The recommended setpoint is A. If Economizer is allowing air which is too warm or too humid to enter the system, control may be changed to a lower setpoint (B, C, or D). Refer to Figure 4 and Figure 5. C. Heat ing Mode (Heat Pump Ap pli ca tion ONLY) 1. On a call for heat the fresh air damper will open to the minimum vent position. V - Economizer Set Up Pro ce dures Notice to Installer: Proper operation of this economizer when used with an outdoor HEAT PUMP system is dependent on the type thermostat installed with the unit. Identify which type thermostat is connected to unit before making any wiring changes if needed. Fig ure 5 (B4,B5)SM air handler economizers come equipped with Honeywell W7212 logic modules which offer additional connections for Demand Control Ventilation (DCV) and Power Exhaust. Contact your local Honeywell or Tradeline representative for additional information on these controls and their specific applications 3

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTIONS FOR ECONOMIZER USED WITH (B4,B5)SM 090/120 SERIES AIR HANDLER Heat Pump Ther mo stat Sin gle "O/B" ter mi nal for se lec tion of Re vers ing Valve Con trol. (B4,B5)SM Series economizers are pre-wired to work in conjunction with single stage Heat Pump thermostats that utilize the "O" terminal to energize the reversing valve when the thermostat "System Switch" is set in the "Cool" mode. Refer to these installation instructions and wiring diagrams for proper connection and operation of the economizer. When the system switch is in the OFF, HEAT, or EMERGENCY HEAT mode setting the economizer is automatically locked out during heating operation. It holds the outdoor fresh air damper at the minimum position setting only when the air handler is operating. Refer to Section VI Minimum Damper Position for proper set up and operation. VI - SYS TEM CHECK AND START UP PROCEDURES Minimum Damper Position Adjustment. Damper min i mum po si tion keeps the out door air damper from clos ing com pletely dur ing sys tem op er a tion for ven ti la tion of build ing con tam i nants and peo ple oc cu pancy. Con sult your State or lo cal codes as required. 1. Disconnect main power to outdoor unit and air handler. 2. Set thermostat "SYSTEM" switch to "OFF" position and "FAN" switch to "AUTO". 3. Install jumper wire across air handler low voltage terminal board "R" and "G" terminal. 4. Disconnect mixed air sensor from the W7212 terminals T and T1 and short terminals T and T1. See Figure 5. 5. Ensure the factory installed jumper is in place across terminals P and P1. 6. Calculate the appropriate mixed air temperature per the following equation: * (Return Air Temp. x % of Return Air) + (Outside Air Temp. x % of Outside Air) = Mixed Air Temperature Example: Assume local code requires 10% outdoor air during occupied conditions, (200 CFM of total unit CFM = 2,000) outdoor air is 60 o F, and return air is 75 o F. Under these conditions, what is the mixed air temperature? (0.1 x 60 o F) + (0.9 x 75 o F) = 6.0 o F + 67.5 o F = 73.5 o F 7. Restore power to the outdoor section and air handler. 8. Carefully adjust the MIN POS potentiometer on the W7212 control module with a small screwdriver until the mixed air temperature reaches the calculated value. 9. Once minimum position adjustments are completed, turn off power to the outdoor unit and air handler. Damper will move to fully close. 10. Remove jumper wire across "R" and "G" on the low voltage terminal board and T and T1 on the W7212 control module. 11. Reconnect the mixed air sensor. 12. Restore power to outdoor unit and air handler. VII - MAIN TE NANCE 1. Damper motor is prelubricated and does not require further lubrication. 2. Make visual inspection of dampers and linkage assemblies during routine maintenance. 3. Filters should be checked periodically and cleaned when necessary. 4. The washable filters supplied with the economizer can be cleaned with water and a mild detergent. 5. Take note of Air Flow Direction marking on filter frame when reinstalling. 6. If filter must be replaced, filter of like kind and size must be used. DO NOT replace permanent filters with throwaway type filters. 4

HARNESS DETAIL COMPONENT CODE WIRE COLOR CODE Revision Change Date E# = WIRE END DESIGNATION E2 STUD #6 18 Ga. Wire E3 Female ¼ Quick Disc. E4 Male ¼ Quick Disc. Insul E6 Wire Nut Size 73B Economizer C7400A Fresh Air Enthalpy Sensor C7150 Mixed Air Sensor MS7510A Damper Actuator 24v W7212A Logic Module TB-11 Terminal Block BLK Black BLU Blue BRN Brown GRN Green GRY Gray ORN Orange RED Red VIO Violet YEL Yellow WHT White 1. C & W2 to be connected to optional electric heat. 2. Remove BLACK wire from air handler low voltage terminal board Y terminal and connect to YELLOW wire from economizer. 3. Second Stage refrigerant cooling with optional economizer installed. A 2 stage thermostat is required for simultaneous operation of the economizer and refrigerant system. Connect Y2 from 2 stage thermostat to BLUE wire from economizer. 4. Heat Pump Economizer Relay. For heat pump applications only. Required for proper operation of an economizer (optional) in the heat pump Heating mode. CONNECT TO "R" FOR AC ONLY APPLICATIONS. Modulating Economizer (B4,B5)SM 090/120 Series Air Handler Date: February 4, 2011 Supersedes: Drawn by: Unit #: 47-374-01 Diagram#: 4737401w Approved by:

HARNESS DETAIL COMPONENT CODE WIRE COLOR CODE Revision Change Date E# = WIRE END DESIGNATION E2 STUD #6 18 Ga. Wire E3 Female ¼ Quick Disc. E4 Male ¼ Quick Disc. Insul E6 Wire Nut Size 73B Economizer C7400A Fresh Air Enthalpy Sensor C7150 Mixed Air Sensor MS7510A Damper Actuator 24v W7212A Logic Module TB-11 Terminal Block BLK Black BLU Blue BRN Brown GRN Green ORN Orange RED Red VIO Violet YEL Yellow WHT White 1. Jumper be tween W2 and E is re quired. 2. C & W2 to be con nected to elec tric heat. 3. Re move BLACK wire from air han dler low volt age ter mi nal board Y ter mi nal and con nect to YEL LOW wire from economizer. 4. Sec ond Stage re frig er ant cool ing with op tional economizer in stalled. A 2 stage ther mo stat is re quired for si mul ta neous op er a tion of the economizer and re frig er ant sys tem. Con nect Y2 from 2 stage ther mo stat to BLUE wire from economizer. 5. Heat Pump Economizer Re lay. Re quired for proper op er a tion of an economizer (optional) in the heat pump Heating mode. Refer to economizer installation instruction for proper connection to thermostat. Modulating Economizer (B4,B5)SM 090/120 Series Air Handler Date: February 4, 2011 Supersedes: Drawn by: Unit #: 47-374-01 Diagram#: 4737402w Approved by:

7

FEBRUARY 4, 2011 NEIMB01 8