Do not touch hot parts (chimney pipe, firebox and hatch). Carefully read through the manual for the heater.

Similar documents
WARNING VILPRA WOOD WOOD HEATER MANUAL. Marketing: SpaDealers. Korsnäs FINLAND +358 (0)

K-Star International Group Inc. K-Star Electronic Appliance Inc. Toll Free:(800)

CHAPTER 8 CHIMNEYS AND VENTS

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications

Troubleshooting and Maintenance: Wood Stoves

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

CHAPTER 8 CHIMNEYS AND VENTS

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Operating and Installation Instructions for CRAMER COE Gas Cooker

Importance of a Draught Regulator

Website:

9. Cooling Water System

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

Vivatubs The Original Slovenian Hot Tub Company

RSHT Volko Supply USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

Weninger GmbH & Co KG Hag 7 A-6410 Telfs

CHIMNEYS AND VENTS CHAPTER 8

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

Installation Manual EF5000 NZ

SAFIRE 1600D, 1800D and 2100D Diesel / fuel oil heaters USAGE, INSTALLATION AND MAINTENANCE

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES PGF 300, 600, 800, 1200

installation and operating instructions OG63XA Cooktop

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

REV.01 /

Installation and Operating Instructions

Electrical Mini Tank Water Heater anual, and Warranty nformation

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Sauna Heater. Installation and Manual

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

Operation instructions

FANERGY Far more than just a fan.

T-29. Heating Systems HOT WATER 2017 PRODUCT CATALOG CENTRAL HEATING SYSTEM WITH SOLID FUEL. Depth (mm) Width (mm) Height (mm)

BVM Corporation SERIES G ELEVATOR 100, 150,175, 250, 350 & 500 Tons

Automatic Water System Pump SERIES

Installation and Operating Instructions

ELECTRIC ASH CAN Model: CVACASH500 Part No:

WARNING: FOR OUTDOOR USE ONLY

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

CHIMNEY INSTALLATION. Technical Bulletin #1

A message from the Holyrood Fire Department. Chimney Fire Safety

Instruction Manual: Le Jurassien Ref 3701

Micro Interior Brushes

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

104 MK II WOOD-BURNING STOVE

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

RS chimney fan for gas and oil applications

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Operating and installation instructions for Fire Lotus H586

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

Instructions On Use A Gas Fireplace Start Wood Burning

INDOOR/OUTDOOR GAS FIREPLACES

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Owner s Manual. A flame to light up your palate! Table of Contents. Warranty card inside

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE

Pump WaterVISE, FloVISE

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Troubleshooting Guide

Fig. 1. Bottle Height---Top of bottle MUST be at this height or slightly higher.

IntrCooll. Cool large buildings at 80% lower running costs

Why our flame is so natural... Our Technology & Engineering Excellence. Efficiency. Safety & Reliability. Fully Remote Controlled

Use, Care, and Installation Guide

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Installation and use of Strong Central Vacuum Cleaning System

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

Installation instruction

THERMALUX SOLID FUEL SLOW COMBUSTION COOKERS AND BOILERS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Technical Specifications Panoramic FX1

INSTALLATION AND SERVICE MANUAL

WOOD STOVE SERVICE MANUAL

Installation Instructions for. OmniFount

2012 INTERNATIONAL FUEL GAS CODE VENTS

INSTALLATION, USER AND MAINTENANCE MANUAL

Evolve 951 & Product specification pages

Cooker Hood User Manual

tççç= ÜÉ~íáåÖ çéíáçåë

RS Chimney Fan for Gas & Oil Applications

Transcription:

PIONEER 25 kw WOOD HEATER MANUAL Marketing: SpaDealers Korsnäs - FINLAND +358-(0)10-239 5600 info@spadealers.eu www.spadealers.eu WARNING Do not touch hot parts (chimney pipe, firebox and hatch). Carefully read through the manual for the heater. Ignition and usage: Heater must be under supervision when it is in use. Keep children away from heater. Place dry paper such as newspaper on the bottom. Use dry wood, 40 43cm long and split to about 4x4cm thickness. Don t burn plastic or items containing sulphur or salt. Do not lean against the part where the warm water enters the tub Read the technical descriptions before installing the heater Read the manual before starting the heater Improper use of the heater can be dangerous The heaters chimney pipes and fire door can become very hot during use. Never use damp wood as it drastically reduces efficiency. Do not drain the hot tub and heater before all the wood has burned out and the embers have faded. Follow product instructions when using chemicals.

USE DRY WOOD! The stove is optimized to provide a good energy yield when dry wood is used as fuel. It will also decrease fuel consumption. For the heater to work efficiently, the wood must be dry. This is also mentioned in the manual. Wood containing high levels of moisture causes poor draft and combustion. Moisture can also begin to leak out from the stove s front edge. Even a single session with such wood can result in a coating on the inner surface which extends heating time. Unless the surface is cleaned, the coating will increase and further reduce the heaters efficiency and prolong the heating time significantly. The pictures show what it can start to look like. It can easily extend the heating time by half or even longer. The images show a different stove model, but the result is the same. Pioneer Wood (HWPPE120) Pioneer Wood is fired with wood and connected to a hot tub on the outside. For the heater chimney pipes and chimney top for effective removal of sparks can be bought separately. Need varies based on location. Wood burning water heater This is a precision built water heater, especially designed for hot tubs. The water is self circulating through the "thermosiphon principle" (hot water rises and creates low pressure, which sucks water from below). It eliminates the need for a circulating pump and electricity, making it possible to heat the water in a hot tub with the heater placed externally. A big advantage is that there will be more space in the tub, which in turn means a smaller model can be selected. The material is aluminum AL5052 which has very good corrosion resistance, especially in marine conditions. It also has excellent thermal conductivity. Rust (3) and gaps (2.6) is made of stainless steel. This ensures years of trouble free use. The stove must be emptied of water after each use. The heat from the fire is efficiently transferred to the water through a unique and sophisticated design that makes the whole firebox a heat transferring surface. The nominal heat output is approx. 25 kw.

INSTALLATION Pioneer Wood is connected to a hot tub using a connection kit (included in complete hot tub packages). The kit is not supplied with the purchase of only the stove but can be ordered separately. Install according to instructions below if the connection pipe is of SpaDelers manufacture. The stove is placed on a surface made from wood, brick or cement. Let it stand a little higher at the rear to prevent air pocket formation that can disrupt the circulation and cause damage to the stove. 1. For the upper connection pipe (outlet), drill a 60mm hole in the side of the hot tub, approx. 6 cm higher than the upper outlet of the stove. In the bottom of the opposite side of the hot tub, make a similar hole for the inlet water to the stove. (NOTE: For an assembled hot tub kit this step and step 2 are already made) 2. The skewed bushing is then screwed into the side. The curved bushing is screwed into the bottom. 3. The rubber pipes are attached between the stove and pipes from the hot tub. If the tubes are lubricated (for instance, cooking oil), it is easier to assemble. Fasten with the included clamps. 4. In order to obtain good water circulation the top pipe should slope upwards approx. 15. WINTER USAGE If there is a risk of freezing damage then the heater must be drained of water after use. Self circulation will cease when the wood has burnt out and the small amount of water remaining in the heater can easily freeze and cause damage to the heater. To keep the water in the hot tub there is a rubber plug complete with accessories. See images below. If electricity is available then a freezing guard can be installed in the heaters firebox to avoid freezing damages when it s not in use. Upper and lower connection pipes must then be insulated. Function Pioneer Wood functions as a conventional wood stove. The firebox is 43cm long and 3 cm in diameter. Maximum effect is achieved by using dry wood (less than 15% moisture), 40 42cm long and split into smaller parts. A load burns for approx. 20 30 minutes. Never use acidic wood as it reduces the effectiveness considerably and may cause heavy deposits on the stove's heat transfer surface. Also avoid alder wood. Controlling the draft and heating effect is done by regulating the lower draft door. For fast heating, open about 10cm and keep it closed to maintain temperature once the water is hot.

Construction The stove is designed to sit on a firm and level surface. Never place it in sand or on soft ground as it causes air pockets that prevent circulation and damage to the stove will result. If the stove is installed with a pump (eg pool), the connection must be equipped with an adjustable tap on the "suction side" that makes it possible to regulate the water flow and pressure. High flow and pressure can damage the stove. Set the regulator so that the hot water from the stove is between 60 70 degrees celcius. Properties Weatherproof design Stove in aluminum Al5052 Grates and hatches in stainless steel Large effect Large firebox 1. Aluminum 2. Ashtray 3. Grate 4. Hatch Specifications Dimensions: 60 cm (height) x 58 cm (length) x 37 cm (width) Weight: 24 kg Firebox: 42 x 27 x 28 cm Heating surface: 1 m² Heating The heating effect varies depending on the quality of the fire wood and how often the heater is refilled. The nominal output of Pioneer Wood is 25 kw. Model Water amount Starting temperature Approximate heating time to 35 C HT150 1200 L 5 C About 3 hours TIP! The heater has a large exterior surface that's in direct contact with the air, therefore it could be good to insulate the outside or place it in an insulated box. The heating time in the winter can then be significantly reduced.

1 2 3 1. Chimney top 2. Chimney pipe 3. Pioneer 25kw