Enhance Alarm Management

Similar documents
DynAMo Alarm & Operations Management

Alarm Management Standards Are You Taking Them Seriously?

Alarm Management for Pipelines

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

Next Generation Alarm Management With DynAMo Alarm and Operations Management

DYNAMO ALARM MANAGEMENT

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

excellence in Dependable Automation ALARM MANAGEMENT

Stavros Chrysanthou Madrid DynAMo Alarm Management Secrets to unlocking complete Operational Integrity

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

2012 Honeywell Users Group EMEA Tyron Vardy A Guide to Effective Alarm Management

2012 Honeywell Pacific Users Group. Sus tain.ability.

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

Exaquantum/ARA Alarm Reporting and Analysis

Alarm Management. Version Prepared by: Michael Davis- Hannibal. Softcon Software Control Services (Pty) Ltd.

Connected Plant. SMARTLINE TRANSMITTERS So Smart, They Make Life Easy

Effective Alarm Management for Dynamic and Vessel Control Systems

Economic and Effective Alarm Management

DON T JUST REPORT ON ALARMS, TAKE

White Paper: CCPS Process Safety Metrics Review Considerations from an ASM Perspective

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

SAFETY ON A BROADER SCALE Safety and security for people, processes, plants, communities and environment

Product introduction Layers of Protection Layer 3: Safety System Instrumented & Mechanical. Layer 2: Alarms Manual action needed

Session Number: 3 Making the Most of Alarms as a Layer of Protection

Alarm Management Reflections

Protect your people, assets and environment while ensuring operational performance.

Thermal Solutions SLATE TM. Dual Burner Applications: Tech Features

Field Products. Apeldoorn Flexible Packaging BV, Netherlands Uses Honeywell s HC900, Experion HS and MXProLine to Improve Stretch Foil Quality

Alarm Management for Pipelines Part 2 What does this mean to me?

Kevin Brown and Chris Stearns

Alarm Management Strategies. Executive Overview Definitions and Current Reality... 4

Alarm Management for SCADA control rooms

Process Solutions. Solution Note. HC900 and OneWireless. Background. Applications. Key issues. Tanks in explosion-proof areas.

Field Products. Solutions for Improved Thermal Process Performance

SCADA ALARM MANAGEMENT. Tim Okely. GWMWater

Critical Condition Management on a Corporate Scale. Lyondell Is a Major Global Chemical Company

Alarm Rationalization

Improving the Performance of Power Plants Worldwide

Alarm Management Optimization (AMO) at Saudi Aramco

Alarm Management Services

Keeping the peace (and quiet)

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

Solutions for Optimizing Oil & Gas Operations. Alarm Management Systems

Diagnostics with fieldbus

02 21st Century Trends Resources 8/24/2017. Trends in Human Machine Interface (HMI) Old School Trends. The Future of HMI

BRIDGING THE SAFE AUTOMATION GAP PART 1

Field Products. Experion LX. Proven DCS for a wide range of industrial applications

Options for Developing a Compliant PLC-based BMS

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

Experion LX Direct Station Specification

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Alarm Management: EPRI Survey on the State of Technology

Meeting PHMSA Alarm Management Requirements: How TiPS Can Help

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

Unifying Alarms and Operating Envelopes for the Achievement of KPI s and Business Objectives

Alarm Management. Alarm Management. DeltaV Whitepaper. February 2011 Page 1

PERFORMANCE HUMAN NEXT-GENERATION SCADA HIGH. MACHINE INTERFACES Configuring HMIs to Display Operator-centric Information

Applying Buncefield Recommendations and IEC61508 and IEC Standards to Fuel Storage Sites

How to Improve Production Efficiency and Safety with Digital Intelligence

ABB Ability System 800xA Alarm Management

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Beyond Compliance Auditing: Drill til you find the pain points and release the pressure!

Your Global Partner for Integrated Skids & Pre-packaged Stations

Tom Miesner Principal Pipeline Knowledge & Development

Benchmarking Industry Practices for the Use of Alarms as Safeguards and Layers of Protection

Intelligent Alarming Leverages Industrial Internet of Things to Reduce Risks and Costs

The Top 10 Worst Performing Alarm Systems in Industry

Emerson Strategies for Abnormal Situation Avoidance & Alarm Management. Executive Overview... 3

2015 Honeywell Users Group Europe, Middle East and Africa

Product Brief for Alarm Analytics V9.2 April 2010

Alarm Management Plan

excellence in Dependable Automation The Alarm Shelving ebook

The Abnormal Situation Management Consortium: Past and Future of Abnormal Situation Management

New requirements for IEC best practice compliance

Alarm System Performance Metrics

Updated May 15, OASyS DNA and Control Room Management Compliance Statement

Improvements in Transmission Control Center Alarm Management Practices

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

2015 Honeywell Users Group Europe, Middle East and Africa. Incident Response at your Fingertips Adrian Fielding, Honeywell

Too Many Alarms: Where Do I Begin?

I Connected IndustriaI. ELSTER Q.Sonic plus. Ultrasonic Flow Meter for Natural Gas Custody Transfer Measurement

Closing the Holes in the Swiss Cheese Model Maximizing the Reliability of Operator Response to Alarms

Pushing Process Limits Without Compromising Safety

Chemical Industry Process Safety trends and developments from EPSC members. Richard Gowland Technical Director EPSC

Understanding the New IEC Alarm Management Standard A PAS White Paper

Product Brief for Alarm Analytics V9.3 October 2013

900 ControlEdge Remote Termination Panel (RTP) For Relay Outputs

Alarms play a significant role in maintaining plant

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

Leak Detection Program Management (RP 1175) April 24-26, 2018 St. Louis, Missouri

Alarm Management & Graphics Projects. Ian Nimmo User Centered Design Services LLC

LOPA. DR. AA Process Control and Safety Group

Chemical Solutions. Automation Solutions for Chemical Producers

EXPORTING ALARM SETPOINTS IN SIEMENS PCS7

WW HMI SCADA-02 Discover the new Alarm improvements delivered in Wonderware System Platform 2014

STT850 and STT750 SmartLine Temperature Transmitter HART Communications Options Safety Manual 34-TT Revision 4 September 2017

Transcription:

White Paper Enhance Alarm Management Executive Summary A properly design alarm management system will minimize production losses, safety incidents and environmental excursions. To do this effectively, the alarms need to be designed for the process and managed for continuous improvement. It is important to evaluate the alarms based on process upsets and verify the functionality of the alarms as they relate to the operation. It is the operator s job to react to the alarm but the alarms need to be monitored and managed.

Enhance Alarm Management 2 Table of Contents Executive Summary... 1 Document Terminology... 3 Evolution of the Control Room... 4 The Value of a Properly Designed Alarm Management System... 4 Components of an Alarm Management System... 4 The Effect on Alarm Management... 5 Getting the Right Alarm at the Right Time... 6 Realizing the Benefits: Operate More Intelligently... 6 References... 7 Table of Figures Figure 1: Components of an Alarm Management System... 4 Figure 2: Setting the benchmark with EEMUA 191 and ISA 18.2... 5 Figure 3: Honeywell's alarm management software DynAMo Metrics & Reporting dashboard pictured... 6

Enhance Alarm Management 3 Document Terminology Name Definition EEMUA Engineering Equipment Material Users Association LOPA Layers of Protection Analysis ISA 18.2 ANSI/ISA-18.2-2009 DCS Distribute Control System ASM Abnormal Situation Management KPI Key Performance Indicator ISA International Society of Automation API 1167 American Petroleum Institute Recommended Practice 1167

Enhance Alarm Management 4 Evolution of the Control Room The dynamics inside a typical control room have undergone a distinctive evolution over the last 25 years, and although the importance and function has not diminished, the way control rooms operate has changed significantly. Twenty-five years ago, the control room used annunciator panels to display alarms and was local to the operational area with a limited and well-defined focus. By design, the number of alarms was limited due to instrumentation, cost and had action plans with procedural expectations for handling these engineered alarms. Today s control room is entirely different. Typically, a central control room oversees multiple areas that contain significantly more instrumentation along with advanced controls. The alarms are no longer engineered and have increased in numbers due to HAZOP or LOPAs processes, incident investigations and the ease of configuring alarms in a distributed control system (DCS). The increased number of alarms with a significant number of them incorrectly configured has created an environment for an operator to miss critical alarms because there are too many, or there is an attitude of complacency when dealing with alarms. This evolution has created a need for the operator to use an integrated system to visualize what is happening across the different parts of the plant. Operators leverage technology to connect all of their systems for a more complete and comprehensive view of operations, but by doing so, it becomes difficult to determine which areas have the highest priority or require immediate attention. The Value of a Properly Designed Alarm Management System A properly designed alarm management system, if implemented correctly, can provide immediate value. By finding correlations between recurring conditions that trigger a destructive event such as a shutdown, equipment failure, or perpetuate an unsafe situation, a properly designed alarm system can provide operators with advance warning so that they can avoid the situation altogether. The benefits include: Reduced maintenance costs by avoiding unplanned maintenance Increased production by minimizing downtime Increased profitability by improving productivity. Components of an Alarm Management System Console DCS Data Processing Reports End Users Figure 1: Components of an Alarm Management System

Enhance Alarm Management 5 Data Collection. Data is automatically retrieved from the computer control system without user intervention Data Cleansing and Pre-Processing. Filters and data cleansing rules are applied to the data to ensure data integrity, eliminate false positives and identify the data set to be analyzed Calculation and Data Analysis. Apply any number of calculations or analyses to the defined data set. For example, alarm rate per operator per hour Report. All results are stored for automated reporting and future data analysis exercises. For example, Key Performance Indicator (KPI) reports can automatically be generated and displayed using a web based reporting application. The Effect on Alarm Management An effective alarm management system offers many benefits to a site, including: Improved facility safety Ability to prioritize the issues that are affecting productivity Being an integral component of early event detection systems. Recently, there has been heavy emphasis placed on the number of alarms that operators see on a daily basis, and how this hinders their ability to be effective. The argument is that there is a limit to the number of alarms an operator can handle at any given time, so we must reduce the total number of alarms that an operator has to deal with to a manageable level. The table below is based on Honeywell s findings of typical alarm scenarios across various process industries, as compared to the acceptable level of alarms as defined by the Engineering Equipment & Materials Users Association (EEMUA) and the International Society of Automation (ISA). Figure 2: Setting the benchmark with EEMUA 191 and ISA 18.2

Enhance Alarm Management 6 While these benchmarks provide a good understanding of how many alarms operators can handle, the basic purpose of alarms needs to be kept in mind. Alarms are meant to alert operators when there is an abnormal situation on the plant floor that is preventing optimal performance, whether that is from a safety or productivity perspective. A key alarm management priority is to ensure that alarms are being created in such a way that an operator receives the right alarm at the right time. Getting the Right Alarm at the Right Time Given the propensity for developing alarms for any type of abnormal situation, thought must be given to finding ways of not only reducing the number of alarms, but also ensuring that operators are getting the right alarms with enough time to react to them and prevent a potential incident. Establishing an alarm philosophy can reduce the number of alarms an operator faces by bringing focus to your alarm management strategy. An alarm philosophy will help you create and adhere to rules for improving and managing the effectiveness of your alarm systems. An alarm philosophy can help ensure that you engineer your alarms to follow industry best practices, standards and guidelines such as EEMUA 191, YA711, NUREG 0700, API 1167 and ISA 18.2. An alarm rationalization will decrease duplicate or redundant alarms and improve the documentation for the designed alarms. It is a good practice to rationalize all alarms for new equipment and to include the rationalization process in HAZOPs, LOPAs and incident investigations. An alarm rationalization cannot only reduce your total number of alarms, but it can also improve the behavior of any troublesome alarms and prioritize your alarms so that you can concentrate on those that have the biggest impact on the safety and performance of your plant. Realizing the Benefits: Operate More Intelligently An effective alarm management system allows you to operate more efficiently and more intelligently. By using information systems to collect data from your equipment and processes, you are able to leverage the power of collaboration to find the connections between events across your plant. This information can help you to detect and automatically correct abnormal situations before they become problems, keeping your plant online and producing. Alarm systems can now focus on alerting operators to events that are new, unique and detrimental to the process and allowing operators to spend the right amount of time addressing those situations. Figure 3: Honeywell's alarm management software DynAMo Metrics & Reporting dashboard pictured

Enhance Alarm Management 7 References ANSI/ISA 18.2 2009 Management of Alarm Systems for the Process Industries EEMUA No.191 Alarm Systems A Guide to Design, Management and Procurement For More Information Learn more about how Honeywell s alarm management solution can improve safety and reliability at your plant, visit our website www.honeywellprocess.com/software or contact your Honeywell account manager. Honeywell Process Solutions Honeywell 1250 West Sam Houston Parkway South Houston, TX 77042 Honeywell House, Arlington Business Park Bracknell, Berkshire, England RG12 1EB Shanghai City Centre, 100 Junyi Road Shanghai, China 20051 www.honeywellprocess.com WP-14-05-ENG January 2014 2014 Honeywell International Inc.