Actionair. Hot/Shield PTC. BROCHURE UPDATED* High Operating Temperature Smoke Management and Fire Dampers

Similar documents
Actionpac LNS3 Intelligent Damper Control and Monitoring System

Actionpac 60/120 (LNS Standard)

V3 Intelligent Damper Control and Monitoring System

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

October 2013 Bespoke Intelligent Damper Control and Monitoring System

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Able to respond to smoke alarms for the protection of escape routes and areas with sleeping risk (ADB)

Fire dampers. For diverse applications

FSD-TD Series. Fire and Smoke Dampers B RITAI N. LPCB certificated fire dampers (LPS 1162)

TransShield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper

Installation Datasheet

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Actionair Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

SECTION AIR DUCT ACCESSORIES

CLN 3 ATTRACTIVE JOINABLE LINEAR PROFILE UP TO 8 SLOT TRACKS AVAILABLE HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Intumescent Fire Dampers

DUCTGARD. Duct Mounting Smoke and Fire Control Dampers

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

SMOKE DAMPERS AIRFOIL STAINLESS STEEL

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Compact. Efficient. TROX.

Chilled Water DOAS Fan Powered Terminal Units

Life Safety Dampers Selection and Application Manual

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

SINGLE DUCT TERMINAL UNITS

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Loss Prevention Standards

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

Panther Fan Coil Unit

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Building Services Brochure

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Units for suspended cei lings

SMOKE DAMPERS SMOKE DAMPERS

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

THE HOME OF REACTIVE PROTECTION SYSTEMS

Aegean Range. A new range of fan coils for heating and cooling commercial applications

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

XB-EFA-8L-BK & XB-EFA-8R-BK

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Construction Electrical

Exhaust Duct Design Page 1 of (C)

Ceiling diffusers. Type DLQL

FUME EXTRACT STRATEGY STATEMENT

SECTION DUCTWORK

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

D2E Duct Smoke Detector

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Cassette units Model Comfort Circle. - heating - cooling - ventilation

Units for suspended ceilings

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

CASSETTE UNIT. Comfort Circle

Lonworks Damper Interface Catalogue

Technical Data Ducted Three Phase Split System Air Conditioner

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

TUNNEL FANS STANDARD AND HOT SMOKE

CP+ Gas & Oil Cabinet Heater Range

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

Outside Air Requirements... SOLVED!

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

CONTROL THE PERIMETER EFFECTIVELY HORIZONTAL/VERTICAL FLOW PATTERN ONBOARD/REMOTE SENSING EXCELLENT THROW & FLOW HEATING AND COOLING CHANGEOVER

Efficient Cooling and Heating. Flexibility Is The Key

ROOFMASTER STEF-HT ROOF FAN

SECTION AIR COILS

EASY VOLUME ADJUSTMENT INCLUDED FLEX CLAMP EXCELLENT THROW & FLOW HEATING AND COOLING TERMINAL REHEAT AVAILABLE

Ceiling air diffuser INDULTHERM INDULTHERM-e

AIR HANDLING UNITS MANDÍK

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

SIMPLICITY FULL MODULARITY?

Direct Fired Heater Model AD Specification

Title: Fire resistance test utilising the general principles of BS 476: Part 20: 1987 on four specimens of Uninsulated Air Valves.

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Direct Gas-Fired Make-Up Air

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Transcription:

March 004 BROCHURE UPDATED* NOV 005 PAGES 1,,3,4,5,7, and 8 Actionair Hot/Shield PTC High Operating Temperature Smoke Management and Fire Dampers Features and Design Guide Smoke Management and Fire Dampers operational up to 300 C for a period of 1 or hours (two versions available). Thermally insulated electric Control Modes. Pneumatic option available C for one hour. Halogen free low smoke and fume cabling supplied as a standard feature. Low closed blade leakage. Dampers when closed are compliant to BS 476 Part 0 Fire Damper Test Standard. Actionpac Damper Control System compatibility. Hot/Shield Vent PTC reverse action dampers for High Operating Temperature Smoke Control and Extract applications. Dampers Designed and Built in Britain

High Operating Temperature Smoke Management and Fire Dampers Introduction Actionair have developed a new technically advanced thermal enclosure that actually has the ability to absorb heat energy when subjected to a high temperature environment. The performance criteria involves continuous operation of the complete damper and actuator assembly at elevated temperatures. This new enclosure is made from a phenolic composite resin with excellent endothermic properties. A chemical reaction occurs within the insulating material when it is heated. This reaction has the effect of lowering the temperature inside the enclosure, thus prolonging the duration of the actuator s operation at elevated temperatures. Smoke and other products of combustion kill at least 80% of recorded fire victims, smoke is debilitating and can render people unconscious minimising their chances of survival. Many more die weeks or months later from the lingering effects and toxic effects of smoke inhalation. Smoke and toxic gases the Silent Application High Operating Temperature Smoke Management and Fire Dampers are designed for installation in high temperature ductwork systems with mechanical smoke extraction. As these ductwork systems regularly serve more than one fire zone or floor when smoke extraction is conducted from one area, it is essential to fully fire protect adjoining fire zones from ductwork penetrations that are connected to the smoke extract duct. For this purpose dampers, when closed are a fire rated damper to BS 476 part 0 for up to hours, thus providing the fire isolation required. Closure of the Damper is achieved by removal/loss of the electrical supply.when used for smoke extraction, under authorised control, the damper will remain open under electrical power for a period of 1 or hours at temperatures of up to 300 C thus allowing the safe extraction of Killers have to be managed and controlled quickly and effectively to avoid confusion and panic from the threat posed to life safety and the extraction and control of these deadly gases is of paramount importance for the safe evacuation of the buildings occupants. The importance of the subsequent smoke damage that can occur to adjacent property and fittings is also recognised, as this can have disastrous effects on homes and businesses as recognised in the Loss Prevention Council Design Guide for Fire Protection in Buildings. Actionair have developed the Hot/Shield PTC High Temperature Smoke Management and Fire Dampers along with the Hot/Shield Vent PTC Smoke Control and Extract Dampers to enable the concepts of fire engineering to be employed in ducted smoke ventilation systems. These dampers designed, tested and approved to deliver high temperature operation at up to 300 C for 1 and hours, provide the designer with the capability of extracting hot smoke and combustion gases through a common smoke extraction duct linked to adjacent fire zones and floors. As smoke can spread rapidly and efficiently through a building ductwork system, damper operation needs to be initiated by a smoke detection system, as thermal sensing can often be too late. and Hot/Shield Vent PTC dampers are designed to be interfaced with a smoke detection/fire alarm system. smoke and hot gases of combustion through the extended fire compartment created by the fire rated ductwork. Smoke Management Fire Dampers may also be used for controlled supply of make up air as a function of the fire engineering process. Hot/Shield Vent PTC High Operating Temperature Smoke Control and Extract Dampers provide flexible smoke management where other fire compartments are not interconnected to a common fire rated ductwork system. Designed to spring to the open position by stored energy and remain closed when powered. Hot/Shield Vent PTC dampers allow controlled smoke extraction to take place with a dedicated smoke control system if required, but retaining low leak closure of the smoke extract duct penetrations into the protected space during normal conditions. Casings Features With double skin spigotted galvanised steel (to BS EN 1014) casing the Hot/Shield PTC dampers comply to Class A and B of Eurovent Document / and Test Procedures for Classes A, B and C of HVCA Ductwork Specification DW144. Damper casings are manufactured with fully welded spigotted connections suitable for Square, Rectangular, Circular and Flat Oval duct connections. As an extra cost option, casings can be manufactured in Type 1.4016 (430) Ferritic or Type 1.4401 (316) Austenitic Stainless Steel. Proportional Torque Control A new generation High Operating Temperature Smoke Management and Fire Damper, thermally Insulated Control Mode assembly, with a unique and dedicated Proportional Torque Control for optimised Damper/Control Mode torque performance. The unique snaplock drive interface ensures user friendly, easy and secure connection of the Control Mode to the Damper. The drive interface, which is totally independent of the ductwork, and provides ease of connection to square, rectangular, circular and flat oval ductwork, including Fire Rated Ductwork. Blade Features The Damper blades are aerodynamic,double skin (Type 1.4016 to BS EN 10088- Ferritic Stainless Steel) which are 75mm deep and interlock to form a positive smoke and fire resisting shield. Incorporated within the blade profile is a silicone seal to ensure low closed blade leakage at temperatures up to 300 C for 1 or hours. Stainless Steel blade end bearings and peripheral gasketting maintain the low closed blade leakage allowing for expansion under full fire conditions. Optional Blade construction Type 1.4401 (316) Austenitic Stainless Steel. Parameters and Hot/Shield Vent PTC Dampers to maximum width and height dimensions (see page 6) can be used where the operating total system pressure is up to 10 Pascals and duct velocities to 15m/second. As with any life safety damper product, a suitable planned inspection programme should be implemented. For specialist and/or aggressive applications, please refer to Actionair Sales Office.

High Operating Temperature Smoke Management and Fire Dampers Control Options A choice of a 4V or 30V Control Modes located outside the ductwork and (protected by its own thermally insulated enclosure) and Halogen Free Low Smoke and Fume cables, allows Damper control up to 300 C for a period of 1 or hours. The Control Mode upon receipt of the relevant supply voltage will motor the Damper to the open position. Closure of the Damper is achieved by removal/loss of the electrical supply. The Damper when closed will provide protection in accordance with BS 476 Part 0. Control Modes have two separate volt free contacts for the provision of external damper status indication. (No thermal links available). Hot/Shield Vent PTC Dampers and associated Control Modes are reverse action with spring opening. Hot/Shield and Hot/Vent/Shield HM5 PTC 4V 7W (10VA), end switches SPDT V 6(3)A XNNN0081 Hot/Shield Power Off Fail-safe Close HM6 PTC 30V 8W (1.5VA), end switches SPDT V 6(3)A XNNN008 Hot/Shield Power Off Fail-safe Close HM5 PTC Vent 4V 7W (10VA), end switches SPDT V 6(3)A XNNN0083 Hot/Vent/Shield Power Off Fail-safe Open HM6 PTC Vent 30V 8W (1.5VA), end switches SPDT V 6(3)A XNNN0084 Hot/Vent/Shield Power Off Fail-safe Open HM5-H PTC 4V 7W (10VA), end switches SPDT V 6(3)A XNNN0085 Hot/Shield Power Off Fail-safe Close HM6-H PTC 30V 8W (1.5VA), end switches SPDT V 6(3)A XNNN0086 Hot/Shield Power Off Fail-safe Close HM5-H PTC Vent 4V 7W (10VA), end switches SPDT V 6(3)A XNNN0087 Hot/Vent/Shield Power Off Fail-safe Open HM6-H PTC Vent 30V 8W (1.5VA), end switches SPDT V 6(3)A XNNN0088 Hot/Vent/Shield Power Off Fail-safe Open See wiring detail below. Hot/Shield and Hot/Vent/Shield Control Modes HM5 PTC and HM6 PTC (operational for 1 hour @ 300 C) and HM5 H PTC and HM6 H PTC (operational for hours @ 300 C) are NOT supplied with the Electrical Thermal Release (ETR). They Fail-safe when the power is off/interrupted). Hot/Shield and Hot/Vent/Shield HM5-3P PTC 4V 7W (10VA) end switches SPDT V 6(3)A XNNN0094 Hot/Shield Power Off Fail-safe Close -10V Set position HM5-3P PTC Vent 4V 7W (10VA) end switches SPDT V 6(3)A XNNN0095 Hot/Vent/Shield Power Off Fail-safe Open -10V Set position Hot/Shield and Hot/Vent/Shield Control Modes HM5 3P PTC (operational for 1 hour @ 300 C) are NOT supplied with Electrical Thermal Release (ETR) and Fail-safe when the power is off/interrupted. NOTE: 1 hour version only available. Hot/Shield and Hot/Vent/Shield Position Drive Open / Drive Closed HM5-P PTC 4V 7W (10VA), end switches SPDT V 6(3)A XNNN0098 HM6-P PTC 30V 8W (1.5VA), end switches SPDT V 6(3)A XNNN0099 HM5-P and HM6-P are NOT supplied with ETR and remain in the desired emergency position when power is interrupted. Application and Wiring HM9 PTC Pneumatic Air Off Fail-safe Close XNNN00301 HM9 PTC Vent Pneumatic Air Off Fail-safe Open XNNN00304 Pneumatic version rated at C for 1 hour. Mode HM5 (4V System) and HM5 H Power On Damper motors open. Power Off Spring closure. Cable specification: Si HF Low Smoke and Fume, Halogen Free, to IEC 754-1. Conforming to 73/3/EEC directive. Release Time secs. Reset Time 60 secs. (Connect 4V via a safety isolating transformer.) A.C./D.C.4V / 60 Hz 10 V A 7/ W 30...+ C CONTINUOUS A.C. V 6(3)A M 1 1 3 4 + SUPPLY 4V A.C. or D.C. VOLT FREE CONTACT CLOSED WHEN DAMPER RELEASED VOLT FREE CONTACT CLOSED WHEN DAMPER RESET Mode HM6 (30V System) and HM6 H Power On Damper motors open. Power Off Spring closure. Cable specification: Si HF Low Smoke and Fume, Halogen Free, to IEC 754-1. Conforming to 73/3/EEC directive. Release Time secs. Reset Time 60 secs. (To isolate from main power supply, the system must incorporate a device which disconnects the phase conductors, with a least 3mm contact gap.) A.C. 30V / 60 Hz 1.5 V A 8 / 3 W 30...+ C CONTINUOUS A.C. V 6(3)A M BLUE BROWN 1 3 4 N L1 SUPPLY 30V A.C /60 Hz VOLT FREE CONTACT CLOSED WHEN DAMPER RELEASED VOLT FREE CONTACT CLOSED WHEN DAMPER RESET Hot/Shield Vent wiring as above. 3

High Operating Temperature Smoke Management and Fire Dampers Multiple Assemblies Square and rectangular casings are available in multiple module arrangements, supplied complete with blanking strips for site assembly by others. Additional support as well as provision for thermal expansion (4mm/metre) should be allowed for on multiple assemblies. Multiple assemblies require installation approval by the relevant local authority. Installation Frame (Accessory) (as required by HVC 6/5/83) Approximate Weights (Kg) Square or Circular Duct Size (mm) Series 1 Square Series 1 Square + Installation Frame Series 601 Circular Series 601 Circular + Installation Frame Installation frames are delivered to site as a complete assembly with the Hot/Shield PTC Damper fitted therein. The frame shall be installed centrally in the thickness of a brickwork or concrete surrounding wall or floor, or in the case of thick walls or floors, so that the centre line of the frame is at least mm away from the nearest face of the wall or floor in which the assembly is mounted. The four tabs (building tie) forming each fixing point shall provide a positive fixing into the structure. Multiple assembly dampers up to 10 x 10 or 000 x 1000 can be fitted into fully assembled installation frames and delivered as one piece. Dampers in excess of this size will be supplied in sections with the installation frame supplied in kit-form, AAF Drg.8057. A drawing and method statement will be supplied for the assembly to be fitted on site. The maximum size of kit-form installation frames will be to accommodate a four section assembly. a. In brickwork or blockwork walls the tabs shall be bent out and solidly built into the mortar joints between the brickwork or blockwork. b. In the case of reinforced concrete walls and floors, the tabs shall be bent out and tied with wire to the reinforcing bars which will be deliberately left protruding into the opening. The gap between the installation frame and builders work shall be backfilled with mortar or concrete on both sides of the flanges. Adjacent frame assemblies must be separated by builders work of a minimum thickness of 5mm (between installation frame upstand flanges) unless approval has been previously obtained from the appropriate Authority. In no case shall the HEVAC/HVCA frame and damper assembly be held in position merely by the adjacent ductwork, and it should be noted that the reinforced concrete structures (especially floors), it will not be sufficient to only backfill between the damper installation frame and the surrounding opening with mortar or fine aggregate concrete mix without provision for tying in the frame to the surrounding reinforced concrete structure. All Fire Damper Installations require relevant local authority approval. 100 3.4 6. 5.3 8.5 1 3.4 6. 5.3 8.5 00 3.4 6. 5.3 8.5 4. 7.4 6.1 10.0 300 4.8 8.7 7. 11.9 3 5.6 10.3 8.4 13.7 400 6.5 11.9 9.6 15.4 4 7.4 13. 11. 17.1 0 8.6 14.6 1.6 19. 5 9.6 16.3 14.0 1.8 600 10.8 18.5 15.9 4.0 6 1.4 0.5 17.5 6.0 700 13.6.1 19.1 8. 7 14.9 4.0 0.7 30.4 800 16. 5.9.5 3.8 8 17.7 8.1 4.3 35.3 0 19. 30.3 6. 37.8 9 0.8 3.4 9.3 40.3 1000 3.5 34.5 3.1 43.1 Control Modes 5 & 6 7.6 Kg (including drive interface) Stud Partition Dry Wall Fixing For preferred tested method, please refer to report number 1065 and/or contact our sales office. 4

High Operating Temperature Smoke Management and Fire Dampers Dimensional Data Series 1 and 31 (square/rectangular) Duct widths and/or heights between 100mm 175mm, will have nominal damper size of 00mm. Duct widths and/or heights between 176mm 00mm. Please refer to the Actionair Technical Sales Office. Dampers with duct widths and/or heights of between 00mm 1000mm are supplied as nominal damper sizes and without transformation sections. Series 1 TRANSFORMATION SECTION SQUARE OR RECTANGULAR 38 38 78 38 38 Series 31 Hot/Shield Vent PTC SQUARE OR RECTANGULAR 5 * DUCT HEIGHT 100-1000 5 DUCT WIDTH 5 100-1000 8 83 * DUCT HEIGHT 57 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 116MM DAMPER SPIGOTS 5MM UNDER DUCT SIZE Dampers with Installation Frames Series 601 and 3601 (circular) Transformation sections are always included. Dampers with duct diameters between 100mm diameter 1mm diameter, will have nominal damper size of 00mm diameter. Dampers with duct diameters between 151mm diameter 98mm diameter, will have nominal damper size +mm. Dampers with a nominal damper size between 983mm diameter 1000mm diameter, please refer to the Actionair Technical Sales Office. Series 601 5 5 CIRCULAR 65 38 78 Series 3601 Hot/Shield Vent PTC 38 65 CIRCULAR 75 DUCT DIAMETER 100-1000 DUCT DIAMETER 5 100-1000 5 8 108 8 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT DIA + 166MM DAMPER CIRCULAR SPIGOTS 3MM UNDER DUCT SIZE Dampers with Installation Frames Series 701 and 3701 (flat oval) refer to Actionair Sales Office. General All dampers are suitable for both horizontal and vertical application, for airflow in either direction. This information is for guide purposes only, the Actionair Technical Sales Office will provide full dimensional data on request. All dampers are life safety products and should be treated with care during installation. 5

High Operating Temperature Smoke Management and Fire Dampers Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of Hot/Shield PTC High Operating Temperature Smoke Management and Fire Dampers. A programme of extensive tests was carried out in the Reverberation Chamber and North Transmission Chamber of Sound research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos. 4196, 4773, 4856, 4857 and 4954. This independent test facility is approved under the NAMAS Scheme. From the selection of a duct velocity within the operational parameters of the damper a resultant pressure drop from Table 1 can be determined and the sum of these two components applied to the Velocity x Pressure Drop Vs Sound Power Level Graph. (Table ) The graph is the result of a full range of acoustic tests on Hot/Shield PTC High Operating Temperature Smoke Management and Fire Dampers with the blades set in then fully open position. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) is obtained. Example: Duct with a design velocity of 8 m/sec. Damper Series 1 fully open. Pressure Drop = Pa (Table 1). Multiply Velocity x Pressure Drop 8 x = 176. From Sound Power Graph (Table ) plot 176 on horizontal Velocity/Pressure axis against 1 outlet (induct) graph to obtain 47 dbw on Vertical Sound Power Level Axis. Add or subtract corrections to the 47 dbw to provide full spectrum analysis. Pressure Drop Vs Velocity PRESSURE DROP (Pa) 100 80 70 60 40 30 0 10 98 7 6 5 4 3 Table 1 EXAMPLE LINE TYPE 1 TYPE 601 1 1 3 4 5 6 7 8 9 10 15 VELOCITY (m/s) Damper Leakage and Hot/Shield Vent PTC closed blade leakage as tested on a damper 1000mm wide x 1000mm high. Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dbw) Leakage data at Ambient temperature (Cold Smoke). 10 SOUND POWER LEVEL (dbw) 80 70 60 40 30 0 EXAMPLE LINE 1 BREAKOUT 601 BREAKOUT 601 OUTLET (INDUCT) 1 OUTLET (INDUCT) PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) 1000 0 800 700 600 0 400 300 00 100 80 70 60 40 30 10 0 0 Table 10 0 30 40 60 70 80 100 Outlet (Induct) Spectrum Corrections Octave Band63 15 0 1k k 4k 8k Series 1 +5 +4 +5 +5 +3 +1-3 -5 Series 601 +9 +4 +4 +5 +3 +1-3 -6 00 300 400 0 600 700 800 0 1000 VELOCITY X PRESSURE DROP (m/s Pa) 000 3000 4000 00 6000 7000 8000 00 10000 Breakout Spectrum Corrections 63 15 0 1k k 4k 8k Hz +8 +11 +9 +6-3 -6-14 -17 db +6 +10 +8 +4-3 -3-11 -14 db 10 5 6 7 8 9 10 0 30 40 60 80 100 70 Table 3 LEAKAGE (I/s) The leakage as detailed in Table 3 was achieved after a total immersion test at 300 C for 1 hour (as witnessed by the Loss Prevention Council). 6

High Operating Temperature Smoke Management and Fire Dampers Damper Installation and Control Mode Fitting Dimensional Data 161 411 DAMPER DRIVE SHROUD 191 TRANSIT PLATE 7 snaplock RETAINING PIN LOCATION HOLE Series 1 41 Install the Damper (complete with factory fitted damper shroud and transit plate) into the structure, connect and fit ductwork to damper spigots. Remove transit plate and discard. Slide the snaplock drive interface into the damper drive shroud, snaplock into position. (Care must be taken when back filling to ensure that the snaplock retaining pin location hole and the entry slot of the damper drive shroud is clear of builders work debris). The above dimensional data is for guide/general arrangement purposes. Specification High Operating Temperature Smoke Management and Fire Dampers comprising of 75mm stainless steel aerodynamic interlocking blades incorporating synthetic seal, with stainless steel blade end bearings and peripheral gasketing. Housed in a galvanised fully welded, spigotted casing suitable for square, rectangular, circular or flat oval connections. The totally enclosed precise movement opposed blade drive shall be positioned out of the airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplock drive interface mechanism, which is totally independent of the ductwork. High Operating Temperature Smoke Management and Fire Dampers in association with their appropriate insulated control modes shall be arranged for motor open and spring closed operation interfaced with a smoke detection/fire alarm system. Hot/Shield PTC Damper and selected thermally insulated Control Modes (HM5, HM5 H, HM6 and HM6 H) as supplied by Actionair. Hot/Shield Vent PTC High Operating Temperature Smoke Control and Extract Dampers comprising of 75mm stainless steel aerodynamic blades incorporating synthetic seal, with stainless steel blade end bearings and peripheral gasketing. Housed in a galvanised fully welded, spigotted casing suitable for square, rectangular, circular or flat oval connections. The totally enclosed precise movement opposed blade drive shall be positioned out of the airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplock drive interface mechanism, which is totally independent of the ductwork. Hot/Shield Vent PTC High Operating Temperature Smoke Control and Extract Dampers in association with their appropriate insulated control modes shall be arranged for motor close and spring open operation interfaced with a smoke detection/fire alarm system. Hot/Shield Vent PTC Damper and selected thermally insulated Control Modes (HVM5. HM5 H, HM6 and HVM6 H) as supplied by Actionair Approvals Heat Degradation test witnessed by the Loss Prevention Council. Complies with the latest DW 144 casing leakage specification. dampers, when closed, are compliant to BS 476 Part 0 Fire Damper Test Standards. The insulated Control Modes satisfy the requirements of EN 081-1 and EN 08-1 electro magnetic compatibility. Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. The information contained herein is subject to change without notice due to continuing research and development. 7

Standard Ordering Procedure Please specify Series HS1/PTC HS601/PTC HS701/PTC Accessories Duct Size Control Modes HM5 PTC HM6 PTC HM5 PTC Vent HM6 PTC Vent HM5-H PTC HM6-H PTC Example Square or Rectangular (Motor Open/Spring Closure). Circular (Motor Open/Spring Closure). Flat Oval (Motor Open/Spring Closure). HM5-H PTC Vent HM6-H PTC Vent HM5-3P PTC HM5-3P PTC Vent HM5-P PTC HM6-P PTC For full descriptive list of Control Modes see page 3. no compromise... HSV31/PTC Hot/Shield Vent PTC Square or Rectangular (Motor Close/Spring Opening). HSV3601/PTC Hot/Shield Vent PTC Circular (Motor Close/Spring Opening). HSV3701/PTC Hot/Shield Vent PTC Flat Oval (Motor Close/Spring Opening). IF Installation Frame Nominal Damper Spigot Size 5 / HS1 / IF / 600(W) x 400(H) / HM6 H I I I I I Quantity Series Accessories Duct Size Control Options Quality System Certificate No 017 Assessed to ISO 01 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (017) 76100 Fax: (017) 646 International Code: +4417 Email: sales@actionair.co.uk Website: Part of Ruskin Air Management Limited HM9 PTC Pneumatic HM9 PTC Vent Pneumatic Product Range Smoke/Shield PTC Automatic Smoke and Fire Dampers Vent/Shield PTC Automatic Smoke Release Dampers High Operating Temperature Automatic Smoke and Fire Dampers Hot/Shield Vent PTC High Operating Temperature Automatic Smoke Release Dampers Actionpac LNS Addressable Smoke and Fire Damper Control Systems Actionpac EMS and EMB Electro Mechanical Smoke and Fire Damper Control Systems Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Trans/Shield Air Transfer Smoke and Fire Dampers Air/Shield System Air Balancing and Shut-off Dampers Energy/Shield Heavy Duty Air Control and Shut-off Dampers Flame/Shield Adjustable Coated Baffle Grease Filters Access/Shield Removable Hinged Insulated Access Doors Hydropac PHW 30 Horizontal Waterside Control Fan Coil Units Aeropac PHA 30 Horizontal Airside Control Fan Coil Units Hydropac PHW 170 Horizontal Slimline Waterside Control Fan Coil Units Hydropac PVW 30 Vertical Waterside Control Fan Coil Units PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.com LNNN001-3/04