Steam Contamination - Causes & Cures

Similar documents
Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

2. Sketch and describe a steam drum internal feedwater pipe. 3. Identify and describe a steam drum continuous blowdown line.

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

Volume 10 Summer Understanding Terminology Key to Treatment Program Success

CHAPTER 18 EVAPORATION AND FREEZING

BOILER SYSTEM CHEMICAL TREATMENT 101

SECTION Boiler Controls & Waste Heat Recovery

Protective Chemistry for Steam Boiler Wet Layup posted to DPS client area on:

Math & Physics. Complete combustion requires an Air-FuelRatio of 14.7 to 1 for combustion.

Boiler Basics. Design and operation

Steam Ancillary Equipment. Primary Steam System, Water Treatment and Auxiliary Steam System Equipment

BOILER 3CL LUNARIO 3CL MACARUBBO 3CL SAGAYO 3CL LUMIGUEN 3CL MIRADOR

3.1 Deaerator Systems

Steam and air don't mix. Chemical dosing of feedwater

Gas Plant Training Module 4 TEG Dehydration Systems

Condensate Recovery and Return System SDR A

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

CONTROLLING BOILER SWELL AND SHRINK

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

Commercial 1 Track. Unit #2: Boilers

5 Separation Processes

By: Prof K. M. Joshi,

Boiler Feed Manual. L-BF-SL (US)

S. P. THERMAL SYSTEMS INC.

Before digging into the 10 things you should know let s start with a brief explanation of the process.

Manual Centrifuges - Installation and Operation

POWERENERGY

REFERENCE SYLLABUS. For FOURTH CLASS POWER ENGINEER S. CERTIFICATE of COMPETENCY EXAMINATION. AB-54 Edition 1, Revision 1,

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM


Company History. The Deaerating Principle. Undeaerated Water Non-Condensibles (Vented) Steam Deaerated Water

CLEANING PRODUCT 10/22/2014 CLEANING PRODUCTS DEFINITION CLEANING, SORTING, AND GRADING

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

International Association of Certified Practicing Engineers

MIST ENTRAINMENT SEPARATION

Water Treatment Improves Your Bottom Line DAVE PICOU WATER CARE SERVICES DIVISION JOHN SCHULTZ TEXTILE CARE DIVISON

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

The HRSG User s Group is going back to Florida!

Conductivity Network Sensor

Feedwater Treatment Manual

MINI-CLASSIC II. Portable Distiller

Distillation Systems for Solvent Recycling

Refinery Vacuum Towers. State of the Art. (Extended Abstract)

Dissolved Oxygen Sensors

Optimizing Strategy for Boiler Drum Level Control

Quick Start Guide LIQ-QSG-Hx438, Rev A June Rosemount Hx438. Amperometric Steam Sterilizable Dissolved Oxygen Sensors

Armstrong Cool-Fog Systems

Boiler Feed Manual. Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel:

DEHYDRATION AND DESALTING

Evaporation is a special case of heat transfer to a boiling liquid.

WARE Boiler book on-line

Solution of I Mid Term Steam Engineering 6ME5A

By:- ASMA PARVEEN Department of Industrial Chemistry Brahmanand College, Kanpur

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

Spray Flow II cc/liter Atmospheric Deaerator. industrialsteam.com

A Newsletter published by. for Industrial Steam and Power Users

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

SCHNEIDER-KESSEL BERLIN

Suction unit disinfection and cleaning with Dürr Dental

1 of 7 12/22/2017, 3:28 PM. Composition

Water Purification 85

TYPE.005 DA-STP TYPE.005 DA-STP-2T. Spray Tray Deaerating Pressurized Boiler Feed Pumps. and. when separate surge tank is utilized

DISTILLATION. The Best Distillation Times Two! 4 FI-STREEM Tap/Pretreated 30 Liter Storage Reservoir WP54 50 Liter Storage Reservoir

APPLICATION GUIDELINES

Strategies in Optimizing Condensate Return

A FREAK INCIDENT OF A BED SUPERHEATER FAILURE

Changing mercerising waste water into money. Caustic recovery for mercerising lye

Silhouette. Feedwater Heater. Boiler Feedwater

Green Energy Engineering, Inc.

FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

Suction Accumulators. Introduction. Suction Accumulators

GESTRA Special Equipment and Vessels for Heat Recovery. For every application the optimally coordinated system

Dissolving Pulp From Cotton Linters BASIC INFORMATION. IPS Engineering

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

ZEROwaste HX PERC SYSTEM USER MANUAL. AIR QUALITY LABORATORIES Seattle, Washington

THE CONDENSATE STORY. Patrick Rogers Nalco Company Spokane, Washington

Preserving the value of your suction unit. Systematic hygiene from Dürr Dental

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

Boiler. Fire tube Boiler:

spiraxsarco.com/uk Condensate recovery in industrial steam systems

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

200Kg/h Frozen Potato Fries Process Machine List

Tel: Fax: Website:

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

Pneumatech: Your guarantee of highquality. air and gas

Deaerators for Industrial Applications

Washing systems/plants

10 HUGE Mistakes Facilities Make in Boiler Operation and How to Avoid Them

Is my water safe to drink? How do I determine the quality of my water? Common Questions about Discolored Water: Cloudy or milky water

IN THE PULP AND PAPER INDUSTRY

Power Boiler Design, Inspection, and Repair

LESSONS LEARNT FROM TROUBLESHOOTING

Spray Painting and Coating

Installation and Operating Service Manual

Water Purification. Quality distilled... the most reliable method of purifying water 81

PARTS CLEANING AND DEGREASING

Speciality Chemicals AGAS MPG PLUS SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES

9707 Key West Avenue, Suite 100 Rockville, MD Phone: Fax:

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

Table 1. Colorless to yellow liquid Flash Point (Pensky-Martens Closed Cup)

Transcription:

ImproChem Technobrief Steam Contamination - Causes & Cures A business of Water & Process

A basic objective in boiler operation is to keep the steam clean and dry. Contamination with boiler water impurities can cause a wide variety of problems including deposits in superheaters, turbines and engines; and process contamination. To produce pure steam, boiler water must be kept from carrying over. There must be good separation of water and steam inside the boiler. Mechanical separators in the boiler drum will do this effectively when the water boils smoothly. However, when the boiling water surges, splashes, foams or mists, the steam is apt to be contaminated. Boiler water composition is not the only factor influencing carryover; mechanical and operational conditions play a big role. Proper water treatment and chemical control, however, are important in keeping the steam clean and dry. Types of Carry-over Carryover into steam lines occurs when boiler water primes, mists or foams. Priming Priming is like the surge of charged water in a bottle that has just been uncapped. In priming, the water is mechanically lifted by the steam as it surges through the water surface. This may be caused by a number of conditions. Sudden steam load increases may siphon water out of the boiler. High water levels in the boiler drum can cause priming by decreasing the surface area for steam release. Falling away of slag from the boiler tubes causes sudden, localized increases in heat input and can disrupt water circulation. Broken or loose baffling causes priming when the hot gas flow is erratic and upsets the boiler water circulation. Sudden and severe contamination in the boiler water will also cause it to prime. Very often, a combination of several of these conditions contributes to priming. Misting Boiler water may also carry over in the form of a fog-like mist (like bubbles on champagne). This mist is difficult to separate from the steam. It is a sudden release in pressure under steam bubbles as they burst on the water surface. This phenomenon is called aquaglobejection, which describes how misting occurs. Misting is not caused by boiler water solids or chemical conditions. (It rarely occurs when there is foaming.) When misting is a problem, effective mechanical steam separating equipment is needed to keep the mist from going off with the steam. Foaming Boiler water foaming causes carryover by forming a stable froth (like foam on beer) that becomes entrained in steam. In addition, many tiny steam bubbles build up in the water itself, causing it to expand into the steam space. Foaming is related to the type and amount of impurities in the boiler water. These impurities affect the nature of the steam bubble film. With pure water, relatively large, tender steam bubbles form and break easily to release the steam. Water impurities make the bubble film tough; the bubbles are small and resist breaking. As these bubbles come through the water surface, the bubbles form froth. To prevent carryover from foaming, the type and amount of dissolved solids in the boiler water must be controlled. Chemical antifoams are very effective in preventing foaming.

Preventing Carry-over Mechanically Mechanical devices for preventing carryover fall into three categories: steam separators, steam washers and steam dryers (purifiers). Some steam separation equipment is always needed to prevent carryover. Steam separators are devices that radically change the steam flow, causing the heavier water and impurities to separate out. The equipment might consist of baffling, or might involve more elaborate centrifugal separation equipment. Steam washers operate on the principle of an open deaerating feedwater heater. Relatively pure Feedwater is sprayed into the steam space to dilute any entrained impurities. Washers are not always necessary and their use is dictated by the amount of space available in the steam drum and the steam purity requirements. Steam dryers operate like filters. Steam dryers slow down the steam velocity and provide maximum surface area over which the steam may pass before leaving the boiler. The various boiler manufacturers have developed several types and combinations of separators, washers and dryers. It is important to keep these devices in good condition. Preventing Carry-over Chemically Of the three types of carryover, foaming is most frequently caused by chemical conditions in the boiler water. Foaming may be prevented in two ways: By controlling the amount of dissolved and suspended matter in the boiler water and By the use of chemical antifoams The American Boiler Manufacturers Association (ABMA) has set certain limits for boiler water solids, above which they will not guarantee steam quality. These limits are shown in Table 1. Table 1 - ABMA boiler water solids limits Boiler Pressure Total Dissolved Solids Total Alkalinity Suspended Solids (bar) (ppm) (ppm) (ppm) 0-20 3500 700 300 20-30 3000 600 250 30-40 2500 500 150 40-50 2000 400 100 50-60 1500 300 60 60-70 1250 250 40 70-100 1000 200 20 The amount of dissolved and suspended matter in boiler water is controlled by blowdown. In preventing foaming, the average boiler water composition is not as important as the consistency of the composition. Radical or sudden changes in boiler water solids content, even if brief, can cause carryover due to foaming. One of the most significant advances made in feedwater treatment in past decades has been the development of temperature-stable chemical antifoams. Antifoams have two basic properties: 1. Insolubility in water and 2. Surface activity

When properly dispersed in boiler water, they are present in the steam bubble skin. Their presence there weakens the film, causing it to rupture easily. Figure 1 A,B & C shows the effect of antifoams on steam bubble formation. To be effective, antifoams must be well dispersed and distributed throughout the boiler water. For this reason, they are commonly incorporated in organic sludge conditioning treatments that act as antifoam carrier. Several modern polymer formulations exhibit antifoam properties and will in most cases cater for small deviations in boiler water solids content. Testing Steam Purity The major problem in testing steam for purity is getting a good sample. Special sampling procedures are needed, as outlined in the ASME Power Test Code (ASTM Method D 1066-66T) and ImproChem Technobrief (Boiler System Sampling: TB-2-1). Figure 1 A,B,C A. Distilled Water - No Antifoam B. Boiler Water - No Antifoam C. Boiler Water - With Antifoam

A business of Water & Process Head Office 1 Pinelands Hill Business Park Maxwell Drive Founders Hill Johannesburg P.O.Box 2954 Kempton Park 1620 South Africa Telephone: +27 11 971-0400 Facsimile: +27 11 394-3436 Email improchem@improchem.co.za Website www.improchem.co.za This information herein may be subject to change without notice and is provided for general guidance only. The dimensions and performance of systems, products and services may vary. Pictures are for example purposes and not to scale. All legal obligations are exclusively as set out in contractual documents. Nothing contained herein constitutes a representation, warranty or undertaking. 2018, ImproChem. All rights reserved. TB 7-2