ENGLISH REMOTE CONTROL MANUAL

Similar documents
REMOTE CONTROL MANUAL

Using the Remote Control Unit

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

RC3-LCD remote control

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS

XHS1271 XHS1872. This air conditioner uses the new refrigerant R410A. COOL/DRY/HEAT Model

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

KMHS1872 KMHS2472 INSTRUCTION MANUAL MODE D EMPLOI. COOL/DRY/HEAT Model. Save These Instructions! Conserver ce mode d emploi

Owner s Manual TABLE OF CONTENTS

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

CONTENTS SAFETY PRECAUTIONS DANGER! CAUTION!

Hi Wall Split Air Conditioners

2. Pictographs 2.1 Basic Operation

Remote Controller. <Open the front cover> <ARC452A4>

MANUAL DE INSTRUÇÕES MANUAL DE FUNCIONAMIENTO OPERATING MANUAL

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Features. Simple One-touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation.

BTU Units WORKING PROGRAM MANUAL

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

AIR CONDITIONER SPLIT WALL MOUNTED

Owner s Manual TABLE OF CONTENTS

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

AIR CONDITIONER SPLIT WALL MOUNTED CONDITIONNEUR D 'AIR MONTE SUR PAROI EN DEUX UNITES

CASSETTE TYPE

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

REMOTE CONTROL PROGRAMMING AND OPERATING MANUAL ENGLISH

High Wall Split Air Conditioners 53QHCT KHCT

53 KNL / 53 QNL OWNER S MANUAL

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-15QPB RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB

English AIR CONDITIONER OPERATING MANUAL. Compact Cassette Type Keep this manual for future reference P/N

WORKING PROGRAM. Heating dehumidifying cooling T 27

Owner s Manual TABLE OF CONTENTS

REMOTE CONTROL MANUAL

FUJITSU GENERAL LIMITED AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P/N

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

CONTENTS SAFETY PRECAUTIONS. En-2 DANGER! WARNING! CAUTION! DANGER! CAUTION!

OPERATING MANUAL UTY-RNNYM P/N English

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

INDOOR UNIT/OUTDOOR UNIT

XS1271 XS1872 INSTRUCTION MANUAL MODE D EMPLOI This air conditioner uses the new refrigerant R410A.

OPERATING MANUAL R410A FUJITSU GENERAL LIMITED REFRIGERANT. AIR CONDITIONER Compact Cassette Type HEAT & COOL MODEL (REVERSE CYCLE) P/N

User manual AG-WT10. Indoor unit air/air heat pump UHB GB LEK

AF-Q100VX AF-Q120VX AF-Q100VX, AF-Q120VX) 15%

Wireless Remote Controller Kit

Owner s Manual TABLE OF CONTENTS

Buttons on remote controller

HEAT & COOL MODEL (REVERSE CYCLE)

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

SC-305/9H. SPLIT TYPE AIR CONDITIONER Instruction manual

Slim Line Ceiling Concealed Ducted Split Systems

OPERATION MANUAL. Wireless Remote Controller Kit

HEAT & COOL MODEL (REVERSE CYCLE)

DVC/DVH 09/12/18/24 Series

Reverse Cycle Split System Air Conditioner

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

Compact Cassette Type

MANUAL MODE D EMPLOI MW09Y3H MW12Y3H MR09Y3H MR12Y3H CONSERVEZ CE MODE D'EMPLOI POUR RÉFÉRENCE ULTÉRIEUR

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

HEAT & COOL MODEL (REVERSE CYCLE)

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST24LBAJ AST30LBAJ. Outdoor Unit AOT24LMADL AOT30LMADL

OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO

INDOOR UNIT/OUTDOOR UNIT

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

R410A ROOM AIR CONDITIONER WALL MOUNTED TYPE OPERATING MANUAL P/N REFRIGERANT KEEP THIS MANUAL FOR FUTURE REFERENCE.

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

English AIR CONDITIONER OPERATING MANUAL. Cassette Type Keep this manual for future reference. PART NO

SPLIT-TYPE ROOM AIR CONDITIONER

OWNER S MANUAL ENGLISH REMOTE CONTROLLER R05 YDS-R

SPLIT TYPE. Instruction manual

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

SPLIT TYPE

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

CR193-RG70E2(2)BGEU

42XQ 42XQA. 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)

This air conditioner uses the new refrigerant R410A.

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

ETN1000/MIGA - Operating manual

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST20AG. Outdoor Unit AOT20AN P/N

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE MSZ-FH50VE MSZ-FH25VE2 MSZ-FH35VE2 MSZ-FH50VE2 INDOOR UNIT. No. OBH623. Models

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM. Quick-Start Guide ON/OFF TEMP MODE SILENCE FP FAN SPEED SWING TIMER ON SWING TIMER OFF SLEEP

Programmable Towel Radiator Manual

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner.

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST24PBA AST30PBA. Outdoor Unit AOT24PMAL AOT30PMAL

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST18AB AST18RB AST24AB AST24RB AST30AB AST30RB

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

SERVICE MANUAL MSZ-GE22VA - E1 MSZ-GE25VA - E1 MSZ-GE35VA - E1 MSZ-GE42VA - E1 MSZ-GE50VA - E1 MSZ-GE60VA - E1 MSZ-GE71VA - E1 INDOOR UNIT. No.

Room Air Conditioner OWNER S MANUAL. Models : LG-BKE 7500 D - LG-BKE 7600 D LG-BKE 7650 D - LG-BKE 7700 D LG-BKE 7800 D

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display

Transcription:

ENGLISH REMOTE CONTROL MANUAL CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read this operating instruction carefully and keep it for future reference. 468040325/01

PRECAUTIONS DISPLAY Information are displayed when the remote control unit is switched on. Operation Mode Automatic Heating Cooling Fan only Dehumidification (dry) Displayed when data trasmitted Or remote control unit lock Clock (hours and minutes) Displayed when the timer on is set and activated Displayed when the timer off is set and activated Indicate that the air conditioner is operating in Clean mode Displayed in Sleep Mode Operation Display in ionizer & E.S.F mode operation Indicate that the air conditioner is operating in Economy mode Set temperature or room temperature Displayed when the temperature is the room temperature Indicate that the air conditioner is operating in I FEEL mode Automatic horizontal air flow oscillation switched on Automatic supply air flap oscillation switched on Description of Low battery detection The low-battery indicator on the remote control will continue to blink when the batteries are low, it may reduce the transmission distance of the remote control and the display becomes blurred. Replace with new batteries immediately. The low-battery indicator will disappear after the batteries are replaced. Fan speed indication Silent speed Low speed Medium speed High speed Strong speed Automatic fan speed ON/OFF OPERATION BUTTON This button turns the air conditioner ON and OFF. MODE SELECTOR BUTTON Press this button to modify the air conditioner mode. (automatic) When this setting is selected, the air conditioner calculates the difference between the thermostat setting and the room temperature and automatically switches to the "cool" or "heat" mode. (heating) The air conditioner makes the room warmer. dehumidification (dry) The air conditioner reduces the humidity in the room. (cooling) The air conditioner makes the room cooler. (fan) The air conditioner circulate the air. COOL / DRY / HEAT / FAN Models 1 SLEEP/ECO BUTTON This button has 2 functions: Sleep function (short press press it less than 3 seconds). When you short press this button, the mark will appear on the display. Economy function (long press press it over 3 seconds). When you long press this button, the mark will appear on the display. For detail see SLEEP MODE and ECONOMY FUNCTION OPERATION.

TRANSMITTER When you press the buttons of the remote control unit, the mark appears on the display to transmit the setting changes to the receiver in the air conditioner. I FEEL TEMPERATURE SENSING AND ROOM TEMPERATURE DISPLAY BUTTON Push this button to activate the temperature control in the remote control unit and show the actual room temperature around the remote control. SENSOR A temperature sensor inside the remote control unit detects the room temperature. TEMPERATURE SETTING BUTTONS - (cooler) Press this button to decrease the set temperature. + (warmer) Press this button to increase the set temperature. FAN SPEED SELECTOR BUTTON Fan speed is automatically selected by the microcomputer Silent speed. Low speed. Medium speed. High speed. Strong speed. SET BUTTON Push this button to select the functions: set the present time set the ON-OFF timer For detail see "HOW TO SET THE PRESENT TIME" and "SETTING THE TIMER". TIMER AND PRESENT TIME SETTING BUTTONS Pushing + or - buttons the setting of the time and timer can be activated. For detail see "HOW TO SET THE PRESENT TIME"and "SETTING THE TIMER". TIMER BUTTON (timer setting) Push thetimer on the display starts the timer ON and OFF setting procedure. For detail see "SETTING THE TIMER". LOCKING THE REMOTE CONTROL Pushing this button freezes the last operation setting.when is activated the remote control will not be able to control the air conditioner.to release the lock status push again. HORIZONTAL SWING/VERTICAL MANUAL SWING BUTTON Press this button, the remote control will run one of the following functions: Horizontal auto swing. If the air-condition has horizontal swing motor, push the button will activate the horizontal air flow to auto swing. Vertical manual swing. If the air-condition only has vertical swing motor, push the button will change the position of vertical air flap by manual. For detail see ADJUST THE AIR FLOW DIRECTION. VERTICAL SWING BUTTON Push button to activate the supply air flap to auto swing. TIMER RESET Push the CLEAR button to cancel all timer setting. ION(OPTIONAL)/CLEAN BUTTON This button has 2 functions: Ionizer function (short press press and release it within 3 seconds). When you short press this button, the mark will appear on the display. Clean function (long press press it over 3 seconds). When you long press this button, the mark will disappear after flash five seconds. For detail see IONIZER FUNCTION OPERATION (OPTIONAL) and CLEAN FUNCTION OPERATION. 2

USING THE REMOTE CONTROL UNIT HOW TO INSTALL BATTERIES Remove the lid in the rear part of the remote control unit. Insert two AAA alkaline batteries of 1,5 V-DC. Make sure to insert the batteries according to the polarity(+/-) marked in the battery compartment. Push the lid back on. HOW TO REMOVE BATTERIES Remove the lid in the rear part. Press the battery toward the negative end and lift it out by its positive end as shown. Remove the other battery in the same way. After batteries change: Press the +, -, SET and CLEAR buttons together. ( After batteries change the remote control needs to be reset to ensure proper functioning. By pressing above mentioned buttons, remote control programs are reset.) The button +,- refered to above is the buttons for setting the hour not temperature. General Note: Replace the batteries when the remote control unit lamp fails to light, or when the air conditioner does not receive the remote control unit signals. Remove the batteries if you do not use the remote control unit for more than one month. The batteries last about six months, depending on how much you use the remote control unit. The batteries of the remote control contain polluted substances exhausted batteries must be disposed according to the laws in force. TEMPERATURE SENSOR SELECTOR Under normal conditions the room temperature is detected and checked by the temperature sensor placed in the air conditioner. Press the remote control I FEEL button to activate the temperature sensor placed in the remote control. This function is designed to provide a personalised environment by transmitting the temperature control command from the location next to you. Therefore, in using this function, the remote control should always be aimed, without obstruction, at the air conditioner. OPERATION WITH THE REMOTE CONTROL UNIT Check that the circuit breaker on the power panel is turned ON and the STANDBY lamp is light up. When using the remote control unit, always point the unit transmitter head directly at the air conditioner receiver. HOW TO TURN ON THE AIR CONDITIONER Press the ON/OFF button to turn the air conditioner on. The indicator OPERATION will light up, indicating the unit is in operation. The remote control unit sends the temperature signal to the air-condition per four minutes, If the remote control unit stops for more than five minutes due to some troubles, the air conditioner will switch to the temperature sensor which is built into the indoor unit and controls the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected in the air conditioner position. REMOTE CONTROL UNIT DISPLAY 3

HOW TO SET THE PRESENT TIME 1. Press the SET button for three seconds. The time indication alone flashes. 2. Press the + or - buttons until the present time is displayed. 3. Press the SET button to stop the indication flashing. COOLING Verify that the unit is connected to the main power and the STANDBY lamp is light up. 1. Set the MODE selector to COOL. 2. P r e s s t h e O N / O F F button and switch the airconditioner ON. 3. Press the TEMP buttons to set the desired temperature (the temperature range is between 30 C (or 26 C) max. and 16 C (or 12 C) min.). Note: The temperature range has 2 options: 16 C -30 C or 12 C -26 C. THE DISPLAY SHOWS THE SELECTED TEMPERATURE. 4. Press the FAN SPEED button to select the fan speed. 5. Press button and button can adjust the air flow direction. For detail see ADJUST THE AIR FLOW DIRECTION. HEATING 1. Set the MODE selector to HEAT. 2. Press the ON/OFF button and switch the air condioner ON. 3. Press the TEMP buttons to set the desired temperature (the temperature range is between 30 C (or 26 C) max. and 16 C (or 12 C) min.). Note: The temperature range has 2 options: 16 C -30 C or 12 C -26 C. 4. Press the FAN SPEED button to select the fan speed. 5. Press button and button can adjust the air flow direction. For detail see ADJUST THE AIR FLOW DIRECTION. For several minutes after the start of heating operation, the indoor fan will not run until the indoor heat exchanger coil has warmed up sufficiently. This is because the COLD DRAFT PREVENTION SYSTEM is operating. DEFROSTING OF HEAT EXCHANGE OUT DOOR UNIT STANDBY When the outdoor temperature is low, frost or ice may appear on the heat exchanger coil, reducing the heating performance. When this happens, a microcomputer defrosting system operates. At the same time, the fan in the indoor unit stops and the OPERATION lamp is flashing until defrosting is completed. Heating operation restarts after several minutes. (This interval will vary slightly depending on the room and outdoor temperature). HEATING PERFORMANCE A heat pump conditioner heats a room by taking heat from outside air. The heating efficiency will fall off when the outdoor temperature is very low. If enough heat is not obtained with this air conditioner, use another heating appliance in conjunction with it. THE DISPLAY SHOWS THE SELECTED TEMPERATURE. 4

AUTOMATIC OPERATION 1. Set the MODE selector to AUTO. 2. Press the ON/OFF button and switch the air condioner ON. 3. Press the TEMP. buttons to set the desired temperature (The temperature range is between 30 (or 26 ) max. and 16 (or 12 ) Note: the temperature range has 2 options: 16-30 or 12-26 DEHUMIDIFYING (DRY) 1. Set the MODE selector switch to DRY. 2. Press the ON/OFF button and switch the air condioner ON. 3. Press the TEMP. buttons to set the desired temperature (The temperature range is between 30 (or 26 ) max. and 16 (or 12 ) Note: the temperature range has 2 options: 16-30 or 12-26 THE DISPLAY SHOWS THE SELECTED TEMPERATURE. When this setting is selected, the air conditioner calculates the difference between the thermostat setting and the room temperature and automatically switches to the COOL or HEAT mode as appropriate. 4. Switch the FAN SPEED selector button to the setting you want. Example of operation diagram in the (Auto) mode with the set room temperature at 23 C. THE DISPLAY SHOWS THE SELECTED TEMPERATURE. Use DRY operation when you want to reduce the humidity in the room. Once the room temperature reaches the set level, the unit repeats the cycle of turning on and off automatically. During DRY operation, the fan speed is automatically set to low or stops to prevent overcooling. Dry operation is not possible if the indoor temperature is 15 C or less. FAN ONLY If you want to make air circulate without any temperature control, follow these steps: The air conditioner changes the operation mode (from cool to heat), if one of the following conditions occurs: - ZONE A: changes if the difference between the room temperature and the temperature set on the remote control unit is at least 3 C.. - ZONE B: changes if the difference between the room temperature and the temperature set on the remote control unit is at least 1 C, one hour after the compressor stop. - ZONE C: never changes if the difference between the room temperature and the temperature set on the remote control unit is no more than 1 C. 1. Set the MODE selector switch to FAN. 2. Press the ON/OFF button and switch the air conditioner ON. 5

ADJUSTING THE FAN SPEED AUTOMATIC Simply set the FAN SPEED selector to the position. A microcomputer automatically controls the fan speed when the AUTO mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to the most suitable level. In FAN Only mode the fan speed is adjusted automatically as in cooling mode. WHEN DIFFERENCE BETWEEN ROOM TEMPERATURE AND SET TEMPERATURE IS Cooling and dehumidifying modes: Heating mode: FAN SPEED 2 C and over High Between 2 and 1 C Medium Below 1 C Low 2 C and over High Below 2 C Medium The above mentioned data make reference to the conditioner operating when the sensor on the remote control unit is ON. If the sensor on the indoor unit is being used then actual operation will slightly differ from that described in the above tables. MANUAL If you want to manually adjust speed just set the FAN SPEED selector as desired. Each time the button is pressed, the fan speed is changed in sequence: SLEEP MODE The SLEEP mode enables you to save energy. 1. Set the MODE selector to cool, dry or heat. 2. Short press the SLEEP/ECO button (release it within three seconds). 3. The mark appears on the display. Short press the SLEEP/ECO button again to release the SLEEP function. What does the SLEEP mode mean? In this mode, the air conditioner will cool or heat the room to the set temperature, and then the thermostat will make the unit pause. After about 1 hour, the air conditioner will automatically reset the set temperature as follows (also refer to graphs). OPERATING MODE SET TEMPERATURE CHANGE Heating Lowered by 1 C Cooling and Dehumidifying Raised by 1 C When the room temperature reaches the new set value, the thermostat will cause the unit to pause. After about 1 hour the temperature will be raised by 1 C in cooling, or lowered by 1 C in heating. This enables you to save energy without sacrificing your comfort. COOLING AND DEHUMIDIFYING Setting temperature Room temperature 1 hour 1 hour TIME (Silent) (Low) (Medium) HEATING Setting temperature Room temperature (High) (Strong) (Auto) 1) Strong fan will only operation cooling & heating mode. 2) Silent fan and Strong fan are both optional, and they depends on the air-condition type. 1 hour 1 hour TIME 6

IONIZER FUNCTION OPERATION (OPTIONAL) Short press ION/CLEAN button (release it within three seconds), the mark appears on the display. Short press the button again to release the IONIZER function (E.S.F works together with Ionizer). I FEEL/ROOM TEMP FUNCTION OPERATION Press button I FEEL/ROOM to activate the I FEEL function. Thermometer sign will appear on the LCD operation display. Select suitable temperature setting. Make sure that the remote control unit is aimed at the air conditioner, with the I FEEL sensor in front. Prevent the I FEEL sensor from being affected by heat sources such as lamps, heaters, direct sun, etc. or from being directly affected by the air conditioner air flow. These may cause the sensor to transmit the wrong temperature data, thereby disturbing the performance of the I FEEL function. By pressing on ROOM temperature, the measured room temperature sign will be displayed. To cancel the ROOM Temperature display press on one of the following: Press again on ROOM Temperature button. Change of MODE button. Room temperature range is between 0 and 50 in 1 increments. Display should show "HI" or "LO" to represent temperature that is above 50 or below 0. SETTING THE TIMER There are two daily timers that can be selected on the remote control. Each timer can be selected by pressing TIMER button. The daily timers T1 and T2 can be set for ON and OFF separately for two different time periods. Timer setting will not change until new setting is input. A) HOW TO SET THE ON TIME 1. Press the TIMER button to select the desired timer. 2. Press the SET button till the ON sign blinks. 3. Press the + or - (HOUR) button until the desired value is displayed. 4. Press the SET button to activate the timer. B) HOW TO SET THE OFF TIME 1. Press the TIMER button to select the desired timer. 2. Press the SET buttons till the OFF sign blinks. LOCK FUNCTION By pressing LOCK button, the remote control will lock the last operation program. All the function buttons will be inoperative, including START/STOP button. By pressing LOCK button again the remote control will be released from its locked position. When lock mode is functioning, the transmission sign will be on. 7

3. Press the + or - (HOUR) button until the desired value is displayed. 4. Press the SET button to activate the timer. C) HOW TO SET A PROGRAM FOR DAILY ON/ OFF OPERATION 1. Press the TIMER button to select the desired timer. 2. Press the SET button till the ON sign blinks. 3. Press the + or - (HOUR) button until the desired value is displayed. 4. Press the SET button again, the OFF sign blinks. 5. Press the + or - (HOUR) button until the desired value is displayed. 6. Press the SET button to activate the timer. Set vertical vanes to the front position during COOLING/DRY operation if humidity is high. If the vertical vanes are set to the left-most or right-most position, condensation will form around the air outlet and drip off. Do not move the flap with your hands when the air conditioner is running. D) HOW TO CLEAR THE TIMER 1. Press the TIMER button to select the timer. 2. Press the CLEAR button if you want that every timer operation will be cleared. S The flap automatically closes when the unit is off. During the heating operation, the fan speed will be very low and the flap will be in the horizontal position until the air being blown out of the unit begins to warm. Once the air warms up, the flap position and fan speed change to the settings specified with the remote control. If the procedure to set the timer is not completed, by pushing the SET button, within 15 seconds the timer operation will be cancelled and the last set-up is restored. ADJUSTING THE AIR FLOW DIRECTION Press button to activate the supply air flap to auto swing. If you push again the flap stops immediately. Press button has two options: If the indoor unit has a horizontal motor, press the button to activate the horizontal air flow auto swing, and press it again, the flap stops immediately. If the indoor unit has not horizontal motor, press the button to stop the vertical air flow auto swing, and the position of vertical air flap will be changed by manual. 8 Use the FLAP button on the remote control to adjust the position of the flap. If you move the flap by hand, the factual flap position and the flap position on the remote control may no longer match. If this should happen, shut off the unit, wait for the flap to close, and then turn on the unit again; the flap position will now be normal again. Do not have the flap pointed down during cooling operation. Condensation may begin to form around the air vent and drip down.

CLEAN FUNCTION OPERATION The CLEAN function comes to dry the indoor coil as well as mould prevention. Long press the ION/CLEAN button (release it after three seconds), the mark will disappear after flash five seconds and notice the indoor unit execute CLEAN function. ECONOMY FUNCTION OPERATION The function comes to reduce energy of the unit operation by limiting the maximum allowed power input 1. Long press the SLEEP/ECO button (release it after three seconds). 2. The mark appears on the display. Long press the SLEEP/ECO button again, to release the ECONOMY function. S Some functions of remote controller will not be available when the unit does not support them! 9