Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382

Similar documents
Digital Thermometer with Ice Alert and Clock

Weather Day & Night Model: BAR339DP / BAR339DPA / BAR339DPU / BAA339DPH

Weather Light Model: BAR210 / BAR210U / BAR210A USER MANUAL. EU-Declaration of Conformity...7 FCC Statement...7 Declaration of Conformity...

+ECO Solar Clock Model: RMR331ES / RMR331ESU / RMR331ESA USER MANUAL CONTENTS

+ECO Solar Weather Clock Model: BAR332ES / BAR332ESA / BAR332ESU USER MANUAL CONTENTS

RF Projection Clock Model: RM939P POLERMO Projection Clock Model: RM939PA

'bregon SCIENTIFIC. Weather Day & Night Model: BAR339DP I BAR339DPA I BAR339DPU I BAA339DPH USER MANUAL

IN-OUT Thermometer with Cable Free Sensor and Clock

Digital Thermometer with Ice Alert and Radio-Controlled Clock Model: RMR682

Digital Thermometer with Ice Alert and Radio-Controlled Clock. Model: RMR382 USER MANUAL CONTENTS

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Wireless Rain Gauge with Indoor Temperature

Honeywell Temperature & Humidity Sensor with LCD

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

BBQ THERMOMETER DESCRIPTION OF PARTS. MODEL NO.: AW129/AWR129 Instruction Manual

4-Day Weather Forecaster Station Model: WMH601

Multi-Channel Indoor-Ooutdoor Thermohygrometer with Cable Free TM Sensor & ExactSet TM Clock

MULTI-CHANNEL IN-OUT CABLE FREE THERMO-HYGROMETER

Weather Forecast RF Wall Clock with Romote Thermometer Model: JMR818WF. User Manual

Cable Free Weather Station with Thermo-Hygrometer and Radio controlled clock

Weather Station with Remote Color Changing Light Box Model: BAR989HG / BAR989HGA USER MANUAL

Multi-Channel IN-OUT Thermo-Hygrometer with Cable Free Sensor and RF Clock

DIGITAL WEATHER FORECASTER WITH REMOTE THERMO-HYGRO SENSOR AND RADIO CONTROLLED CLOCK

Multi-Channel Indoor & Outdoor Thermometer with Cable Free Sensor & Radio Controlled Clock

Desktop Dual-band Radio Controlled Clock with Melody Alarm and Backlight Model: RM926 User Manual

Wake-up Vibration Alarm Model : VR101. User Manual

Wide-Screen Weather Forecast RF Clock with Thermometer Model: JM828WF / JM828WFU. User Manual

Professional Wireless Rain Guage with 4" LCD

Wireless In/Out Thermometer with Atomic Clock

Honeywell. Weather Forecaster with Dual Projection (PCR426W) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW. Error!

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

Wireless Weather Station Model: BAR826HG

EN Oregon Scientific Radio-Controlled Projection Clock (RM816P / RM816PU / RM816PUL) User Manual

Radio Controlled Kids Projection Clock with Nightlight

Weather Station Advanced Model: BAR628HG / BAR628HGU User Manual

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

ELECTRONIC THERMOMETER. Model NTS-912 User Manual CONTENTS

Wireless Weather Station. Table of Contents

INTRODUCTION CONTENTS

WIRELESS COLOR FORECAST STATION

Model: WS-8147U-IT Instruction Manual DC: ATOMIC DIGITAL CLOCK WITH MOON PHASE

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Honeywell Barometric Weather Forecaster (TE653ELW) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 STANDARD PACKAGE CONTENTS 3 BEFORE YOU BEGIN 4

Weather Station with Remote Control Model: BAR289

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Weather System Pro Model: BAR629HG / BAR629HGU User Manual

Projection Alarm Clock

High Resolution Display WIRELESS COLOR WEATHER STATION

FEATURES AND SPECIFICATIONS

Wireless Color Weather Station

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

WIRELESS COLOR WEATHER STATION

WIRELESS COLOR WEATHER STATION

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

ATOMIC DIGITAL CLOCK. Time and Alarm

Model: S88907 Instruction Manual DC: WIRELESS COLOR WEATHER STATION

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Rain Gauge model 00875

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

Reset system Safety and care Warnings Additional resources Troubleshooting Specifications... 16

WEATHER STATION WITH CABLE FREE IN-OUT THERMOMETER UV MEASUREMET AND IN-OUT HYGROMETER MOONPHASE AND RADIO CONTROLLED CLOCK (SWISS SIGNAL HBG )

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

WIRELESS WEATHER STATION

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

DIGITAL ATOMIC WALL CLOCK

COLOUR WEATHER STATION MODEL: AWS888N USER S MANUAL

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

WIRELESS COLOR FORECAST STATION

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

Model: C Instruction Manual DC: WIRELESS COLOR WEATHER STATION

Model: WS-9133U-IT Quick Setup Guide DC: WIRELESS FORECAST STATION

Ambient Weather RC-9362 Atomic Digital Wall Clock with Temperature User Manual

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

433 MHz RADIO CONTROLLED PROJECTION ALARM CLOCK Instruction manual

Atomic Digital Wall Clock

Color Forecast Station. Table of Contents

Atomic Projection Alarm Clock

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor Temperature User Manual

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

9000P Wireless Alarm Owner s Manual

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

WIRELESS WEATHER STATION WIRELESS WEATHER STATION. Please Note. We are unable to supply Additional Sensors for This Weather Station C-8105/C-8145

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

Model: M Instruction Manual DC: WIRELESS COLOR WEATHER STATION Mold Risk for Weather Station & Indoor Remote Sensor Location

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Ambient Weather RC-8461 ClearView Jumbo Atomic Digital Wall Clock with Temperature and Humidity User Manual

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

HSD-200Z Z-Wave Motion Sensor

Ambient Weather RC-8365 ClearView Radio Controlled Projection Clock with Indoor and Outdoor Temperature User Manual

WIRELESS FORECAST STATION

Mood Light and Nature Sound Alarm Clock

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Wireless Home Appliance Timer Remote Control Kit

Atomic Digital Clock with Temperature and Moon Phase

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL 1. INTRODUCTION 2 2. INSTALLATION 2

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

The Digital Door Viewer! User Manual. Motion Activated Sensor MAS 100

Transcription:

Wireless Rain Gauge with Rainfall Memory and Digital Clock MODEL: RGR382 EU-Declaration of conformity... 8 Fcc statement... 8 Declaration of Conformity... 9 USER MANUAL CONTTS Introduction... 2 Main unit overview... 2 Front view / LCD display... 2 Back view... 2 Rain gauge... 3 Overview... 3 Set up rain gauge... 4 Rainfall... 5 Rainfall history... 5 Total rainfall... 5 Rainfall alarm... 5 Signals... 6 Calendar clock... 6 Reset... 7 Precautions... 7 Specifications... 7 About Oregon Scientific... 8 1

INTRODUCTION Thank you for selecting the Wireless Rain Gauge RGR382. NOTE Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. MAIN UNIT OVERVIEW FRONT VIEW / LCD DISPLAY 1 2 3 4 5 6 S I N C E 7 8 9 10 11 12 13 1. Total rainfall indicator 2. Rain gauge RF reception status 3. Number of days of rainfall history 4. Rain alarm indicator 5. Clock alarm indicator 6. Clock AM / PM indicator 7. Rain collector battery low indicator 8. Total rainfall measurements indicator 9. Rainfall history 10. SINCE indicator 11. Main unit battery low indicator 12. Calendar clock / clock alarm / start date of total rainfall record 13. SINCE button: Toggles between starting date of total rainfall calculation and clock; Press and hold to reset the total rainfall counter to start again BACK VIEW 1 2 3 4 5 6 7 8 9 10 2

1. RAIN ALM button: Press to display rain alarm (default 30mm). Press again to return to the rainfall display 2. ALARM button: Turns daily alarm off 3. MODE button: Toggles display between clock with seconds, clock with weekday, calendar and alarm time 4. HIST / UP button: Displays rainfall history in normal mode; Increases a value in rainfall alarm / calendar clock setting mode 5. DOWN button: Decreases a value in rainfall alarm / calendar clock setting mode 6. RAIN ALM ON / OFF button: Enables or disables the rainfall alarm 7. SEARCH button: Search for the rain collector 8. RESET hole: Returns all settings to their default values 9. IN / MM button: Selects between inch and millimeter measurements 10. Battery compartment RAIN GAUGE OVERVIEW Base and funnel: 1. Rain gauge 2. Battery compartment 3. RESET button 3 1. Funnel 2. Indicator

SET UP RAIN GAUGE The rain gauge collects rain and takes readings of rainfall rate and the total rainfall over a period of time. The sensor can remotely transmit data to the base station. The base station and rain gauge should be positioned within an effective range: about 100 meters (328 feet) in an open area. The rain gauge should be mounted horizontally about 1 meter (3 feet) from the ground in an open area away from trees or other obstructions to allow rain to fall naturally for an accurate reading. To set up the Rain Gauge: 3. Remove the fibre tape. To ensure a level plane: Put a few drops of water on the cross at the base of the funnel to check the horizontal level. 3 1 2 1. Remove screws and slide the cover off in an upwards motion. 2. Insert the batteries (2 x UM-3 / AA), matching the polarities (+ / -). Press RESET after each battery change. Water will pool to the center of the cross when the rain gauge is level. 4 4 If water remains on 1-4, the gauge is not horizontal.

If necessary, adjust the level using the screw. To clear the current day s rainfall: Press and hold SINCE for two seconds. Note that this will also clear the total rainfall record. CAUTION Other sensors using the 433 MHz transmission frequency may influence the rainfall reading. Please avoid placing those sensors too close to the unit. NOTE For best results, ensure the base is horizontal to allow maximum drainage of any collected rain. RAINFALL Today s rainfall appears on the 1st line of the display and total rainfall is shown on the 2nd line. Press IN / MM to toggle between inches and millimeters. TOTAL RAINFALL The total rainfall is displayed on the 1st line of the LCD display. To display the commencing date of the total rainfall record, press SINCE. The date will appear on the bottom line of the display. To clear the existing commencing date and reset it to start again, press and hold SINCE. The total rainfall and today rainfall will be reset to zero and the unit will start again to collect the rainfall data. RAINFALL HISTORY The rainfall history is displayed on the second line of the LCD display. The main unit can record and store up to nine days of rainfall. To display the record for a particular day: Use HIST / UP to toggle between daily rainfall and rainfall history over the past nine days. The day of the record will be displayed with a minus (-) sign. Zero (0) means the record is for the current day. 5 RAINFALL ALARM The rain alarm value can be displayed at any time by pressing RAIN ALM. To set the rainfall alarm: 1. Press and hold RAIN ALM for two seconds. 2. Use HIST / UP or DOWN to set the desired value. 3. Press RAIN ALM to confirm. The alarm will be activated.

The rain alarm indicator will light up. The alarm will go off for one minute when the rainfall reaches the preset value and the rain alarm indicator will flash. A reminder beep will be emitted every minute. Once the rain alarm is on the indicator will not stop flashing unless RAIN ALM is pressed or the rain alarm value is changed. To stop the alarm and reminder beep, press any button or change the rainfall alarm value. To toggle the alarm ON / OFF, press RAIN ALM ON / OFF. SIGNALS If without obvious reason the main unit display goes blank, press and hold SEARCH for 2 seconds to enforce an immediate search of the rain collector. ICON DESCRIPTION No signal Searching for signal Signal connected If that fails, check: The remote rain collector is still in place. The batteries of the main unit and rain collector have not run out of power. Replace them if necessary. The transmission is within range and path is clear of obstacles and interference. Shorten the distance if necessary. Then press SEARCH again. 6 CALDAR CLOCK The calendar clock is displayed on the bottom line of the display. Use MODE to toggle between clock, calendar and daily alarm. To set the clock: 1. Press MODE to display the clock or calendar. 2. Press and hold MODE for two seconds and use HIST / UP or DOWN to set the desired clock or calendar value. 3. Press MODE and repeat from step 2 to complete all settings. 4. Press MODE to confirm. To set the daily alarm: 1. Press MODE to display the daily alarm. The daily alarm will be activated automatically. The daily alarm indicator will light up. 2. Press and hold MODE for two seconds and use HIST / UP or DOWN to set the desired value. Press and hold for faster increments. 3. Press MODE and repeat from step 2 to complete all settings. When active, the daily alarm will go off for one minute at the set time and the daily alarm indicator will flash. To stop the alarm: Press any button. The alarm is still active and will go off at the set time the following day.

To activate / deactivate the daily alarm: Press ALARM. NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice. RESET Press RESET to return the unit to the default settings. PRECAUTIONS This product is engineered to provide years of satisfactory service if you handle it carefully. Here are a few precautions: Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts. Do not tamper with the unit s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts. Only use fresh batteries as specified in the user manual. Do not mix new and old batteries. Due to printing limitations, the displays shown in this manual may differ from the actual display. The contents of this manual may not be reproduced without the permission of the manufacturer. Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. 7 NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer. SPECIFICATIONS TYPE MAIN UNIT Display rainfall range (total) Display rainfall range (history / daily) Rainfall resolution Measuring accuracy Display temperature range Operating temperature range Transmission range DESCRIPTION 0 to 25.4 m (0 to 999.99 in) 0 to 2.54 m (0 to 99.99 in) 1 mm (0.04 in) 0-15 mm per hour: +/- 10% Over 15 mm per hour: +/- 15% -5 C to 50 C (23 F to 122 F) -5 C to 50 C (23 F to 122 F) 100 m (328 ft) unobstructed ALARM CLOCK AND CALDAR Clock HH:MM 12 / 24 hour format Calendar Month / Day, Day / Month Alarm 1-min. daily alarm POWER

Main unit Remote rain gauge WEIGHT Main unit Remote rain gauge DIMSIONS Main Unit (L x W x H) Remote rain gauge (L x W x H) 2 UM-4 or AAA 1.5V alkaline batteries 2 UM-3 or AA 1.5V alkaline batteries 117 g (4.1 oz) without battery 241 g (8.5 oz) without battery 93 x 52 x 118 mm (3.7 x 2.0 x 4.6 in) 114 x 114 x 145 mm (4.5 x 4.5 x 5.7 in) (Model: RGR382) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. COUNTRIES RTTE APPROVAL COMPLIED All EU countries, Switzerland CH and Norway N NOTE It is recommended that you use alkaline batteries with this product for longer performance. ABOUT OREGON SCITIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you re in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support.asp For international inquiries, please visit: www2. oregonscientific.com/about/international.asp EU-DECLARATION OF CONFORMITY Hereby, Oregon Scientific, declares that this Wireless Rain Gauge with Rainfall Memory and Digital Clock 8 FCC STATEMT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance

with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio / TV technician for help. Rainfall Memory and Digital Clock Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please visit our website at www2. oregonscientific.com/service for all enquiries. We Name: Oregon Scientific, Inc. Address: 19861 SW 95th Ave., Tualatin, Oregon 97062 USA Telephone No.: 1-800-853-8883 declare that the product Product No.: RGR382 Product Name: Wireless Rain Gauge with 10-Day 9