Problems with Testing Peat for Stability Analysis

Similar documents
EAT 212 SOIL MECHANICS

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

Shear Strength of Soils

This document downloaded from vulcanhammer.net vulcanhammer.info Chet Aero Marine

Laboratory Tests to Determine Shear Strength of Soils

Undrained shear strength in the assessment of slope stability of water defenses

Global Journal of Engineering Science and Research Management

COMPARISON OF SHEAR STRENGTH PARAMETERS OF BLACK COTTON SOIL WITH EFFECT OF RELATIVE COMPACTION

Soil-Structure Interaction of a Piled Raft Foundation in Clay a 3D Numerical Study

APPENDIX D. Slope Stability Analysis Results for Soil and Overburden Storage Mounds

An Experimental Study on Variation of Shear Strength for Layered Soils

Darcy's law 16 Deformation 23-32, 53, 98-99, ; elastic 19-20, 148-

Unsaturated Shear Strength Behavior under Unconsolidated Undrained Tests

Bearing Capacity Theory. Bearing Capacity

Stress-Strain and Strength Behavior of Undrained Organic Soil in Kupondol, Kathmandu

Slope stability assessment

[Gupta* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

CHAPTER 8 SLOPE STABILITY ANALYSIS

Advanced Foundation Engineering. Introduction

Full Scale Model Test of Soil Reinforcement on Soft Soil Deposition with Inclined Timber Pile

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

Compressibility and One Dimensional Consolidation of Soil

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

Consolidation Stress Effect On Strength Of Lime Stabilized Soil

Soil Strength and Slope Stability

Finite Element Methods against Limit Equilibrium Approaches for Slope Stability Analysis

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

ScienceDirect. The Undrained Shear Strength of Overconsolidated Clays

Identification of key parameters on Soil Water Characteristic Curve

Fine Coal Refuse 25 Years of Field and Laboratory Testing Data and Correlations

The University of Iowa Department of Civil & Environmental Engineering SOIL MECHANICS 53:030 Final Examination 2 Hours, 200 points

Reinforcement with Geosynthetics

Lessons Learned From the Failure of a GCL/Geomembrane Barrier on a Side Slope Landfill Cover

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

Soil-atmosphere interaction in unsaturated cut slopes

PILE FOUNDATIONS CONTENTS: 1.0 Introduction. 1.1 Choice of pile type Driven (displacement) piles Bored (replacement) piles. 2.

PULLOUT CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN CLAYEY SOILS

RESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT

Mechanical Behavior of Soil Geotextile Composites: Effect of Soil Type

ISO/TS TECHNICAL SPECIFICATION

Design of Unpaved Roads A Geotechnical Perspective

Effect of pile sleeve opening and length below seabed on the bearing capacity of offshore jacket mudmats

ISO/TS TECHNICAL SPECIFICATION. Geotechnical investigation and testing Laboratory testing of soil Part 10: Direct shear tests

CHAPTER 4 EXPERIMENTAL WORK 4.1 GENERAL

Dam Construction by Stages

Compaction. Compaction purposes and processes. Compaction as a construction process

Backfill Stress and Strain Information within a Centrifuge Geosynthetic-Reinforced Slope Model under Working Stress and Large Soil Strain Conditions

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL

2.2 Soils 3 DIRECT SHEAR TEST

Stability of Inclined Strip Anchors in Purely Cohesive Soil

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

Woven Polyester High. ACETex the proven choice for: n Embankment Support over piles. n Support over voids

Evaluation of undrained shear strength of soft New Orleans clay using piezocone

Experimental investigation and theoretical modelling of soft soils from mining deposits

Development of Bearing Capacity Factor in Clay Soil with Normalized Undrained Shear Strength Behavior using The Finite Element Method

Effect of Placement of Footing on Stability of Slope

Lightweight aggregates in Civil Engineering applications. Arnstein Watn Senior Scientist, SINTEF

SOIL SLOPE STABILITY ANALYSIS. Analyses of slopes can be divided into two categories: 6,Chapter 13 J. MICHAEL DUNCAN

Behaviour of a Strip Footing on Compacted Pond Ash Reinforced with Coir Geotextiles

FINAL COVER VENEER STABILITY ANALYSES FOR SCA DESIGN

IMPACT OF WET-DRY CYCLE ON MECHANICAL PROPERTIES OF EXPANSIVE CLAY UNDER LOW OVERBURDEN STRESS MD ASHRAFUZZAMAN KHAN

Analysis of Embankments with Different Fill Materials using Plaxis-2D

Transition of soil strength during suction pile retrieval

SOIL DATA: Avondale. in Allen, TX. This information was taken from NRCS web soil survey of Collin County, Texas.

CiSTUP Indian Institute of Science Bangalore

Swelling Treatment By Using Sand for Tamia Swelling Soil

SOIL FOUNDATION IMPROVEMENT WITH TIRE-USED TO REDUCE SETTLEMENT OF SHALLOW FOUNDATION EMBEDDED ON SATURATED DEPOK CLAY

SOIL STABILIZATION USING NATURAL FIBER COIR

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

TECHNICAL. Design Guide. Retaining walls made easy with this beautiful solution EARTH RETAINING WALLS

Effect of characteristics of unsaturated soils on the stability of slopes subject to rainfall

Shear strength features of unsaturated clayey sand by lab test

THE ULTIMATE SKIN RESISTANCE OF CONCRETE PILE IN PARTIALLY SATURATED COHESIVE SOIL BY MODIFIED Β METHOD

1 SITE AND PROJECT DESCRIPTION

Paper ID: GE-007. Shear Strength Characteristics of Fiber Reinforced Clay Soil. M. R. Islam 1*, M.A. Hossen 2, M. A.Alam 2, and M. K.

GEOTEXTILE REINFORCED TWO LAYER SOIL SYSTEM WITH KUTTANAD CLAY OVERLAIN BY LATERITE SOIL

Soil characteristics that influence nitrogen and water management

LARGE-SCALE SHEAR TESTS ON INTERFACE SHEAR PERFORMANCE OF LANDFILL LINER SYSTEMS

Slope Stability Analysis

4 Slope Stabilization Using EPS Geofoam at Route 23A

Base resistance of individual piles in pile group

Memo. To Bianca Hardeman (Rijkswaterstaat Waterdienst) Date 18 March Reference GEO Number of pages 20

EFFECT OF THE ROOTS DENSITIES ON THE SHEAR STRENGTH OF ROOT-REINFORCED SOIL

A comparison of numerical algorithms in the analysis of pile reinforced slopes

A numerical study of the effect of soil-atmosphere interaction on the. stability and serviceability of cut slopes in London clay

Undrained shear strength determination and correlations on Søvind Marl Grønbech, Gitte Lyng; Nielsen, Benjaminn Nordahl

EXPERIMENTAL STUDY ON PULL-OUT CAPACITY OF HELICAL PILE IN CLAYEY SOIL

Comprehensive Material Characterizations for a Pavement Embankment Installed with Wicking Fabric

Identifying Residual Soil Parameters for Numerical Analysis of Soil. Nailed Walls

Biotechnical engineering on alluvial riverbanks of southeastern Australia:

Effect of Geosynthetic Reinforcement Inclusion on the Strength Parameters and Bearing Ratio of a Fine Soil

O M E Taha. Keywords: nanoparticles, shrinkage strain, expansive strain, nano-copper, nano-alumina ABSTRACT

COHESIONLESS SOIL PROPERTIES IMPROVEMENT USING BENTONITE

Study on Effect of Water on Stability or Instability of the Earth Slopes

Strength Parameter Selection in Stability Analysis of Residual Soil Nailed Walls

Assessment of Geotextile Reinforced Embankment on Soft Clay Soil

Texas Transportation Institute The Texas A&M University System College Station, Texas

SETTLEMENT MEASUREMENTS OPTIMISING CONSTRUCTION OF A BREAKWATER ON SOFT SOIL

TECHNICAL REPORT STANDARD PAGE 2. Government Accession No. 3. Recipient's Catalog No.

Transcription:

Problems with Testing Peat for Stability Analysis Dick Gosling & Peter Keeton

Scottish Executive Document Published December 2006 Includes requirement for slope stability analysis using infinite slope equation (Skempton & DeLory, 1957)

Peat Is an organic soil It may be defined as: consisting of the remains of dead vegetation in various stages of decomposition which accumulates in a mire It is characterised by: High water content, often several hundred or even thousand percent (geotechnical definition, ie weight of water/weight of solids) Correspondingly high Liquid and Plastic Limits Low bulk density, typically around 1.1 Mg/m 3

Infinite Slope Equation Nothing wrong with equation itself, regularly used for inorganic soils However, its use pre-supposes that the effective stress parameters, c and Φ, are appropriate for peat Furthermore, by implication, that these parameters can be obtained from standard laboratory testing

Overburden pressure The term in the equation is the effective pressure, which is alternatively given the symbol p 0 It will be very low due to peat overburden eg at base of 2 m thick layer with water level at ground level p 0 only about 2 kpa Compare this to an inorganic soil where the same layer thickness and water level would impose a p 0 of 20 kpa, ie some 10 times greater

Effective stress shear strength Muskeg Engineering Handbook (1969) states that: recent research has shown conclusively that it [peat] is essentially a frictional material and that it behaves closely in accordance with the principles of effective stress It goes on to note that an extensive body of test data indicates Φ values are exceptionally high compared with inorganic soils citing Adams (1961) as measuring Φ values as high as 50 degrees Results from consolidated undrained triaxial test with measurement of pore water pressure but this was not today s standard test; it lasted 3 months and required over 50% axial strain to reach failure However standard tests carried out recently can be interpreted to give similarly high Φ values

Effective stress shear strength Hobbs (1986) in his major treatise on peat, does not concur with Muskeg Handbook He specifically excluded any discussion on shear strength Stated that: it is clear that the strength depends not only on effective stress but also on time as the void ratio continuously decreases under maintained load

Laboratory tests SE list of tests that may be of value With classification tests, (i) to (vi), some variations to standard procedures (for inorganic soils) are appropriate for peat No such qualifications are noted for the strength tests, (vii) and (viii) Potential for confusion: undrained/drained not necessarily synonymous with total/effective stress

Laboratory strength tests SE document states that all shear strength tests should be performed on undisturbed samples taken from intact block samples In practice Some clients are supplying block samples and scheduling drained direct shear tests Others have been supplying tube samples and scheduling effective stress triaxial tests, either consolidated drained or consolidated undrained with measurement of pore water pressure

Laboratory Test Problems There are major problems when either direct shear or triaxial tests are performed on peat The following slides, show that peat behaves radically different from an inorganic soil

Consolidation T 100 gives Cv gives Time to failure Conventional δs δv Peat Root Time

Shear box test Normal stress Shear stress Volume lost in consolidation

Direct shear test stress/strain conventional Shear stress Peat Horizontal displacement

Deviatoric Stress v Axial Strain conventional Deviatoric stress Peat - undrained Peat - drained Axial strain

Pore pressure v Axial strain Typical pore pressure curves Initial ó3 Peat pore pressure Conventional - N/C u 0 Conventional - O/C Axial strain Volume change in drained tests behaves as pore pressure in undrained

Undrained Test - Stress Ratio v Axial Strain Peat stress ratio ó 1 ' / ó 3 ' Conventional - N/C Conventional - O/C 1 Axial strain Stress ratio at failure, normally in single figures, for peat between 10 and 100.

Triaxial Tests - Mode of Failure Conventional Test After consolidation After Plastic failure After shear failure Test on Peat After consolidation After undrained compression After drained compression

Stability Analysis Case Histories Rarely undertaken for peat in past but two references given (Carling, 1986 & Warburton et al, 2004) Total of 6 slides back analysed peat typically 1 to 2 m thick slopes around 10 degrees Strength parameters assigned to peat c = 5 to 9 kpa Φ = 21.5 to 23 (or possibly 13.5) degrees Back analyses (with water level at ground level) generally gave F between 2 & 6, ie do not explain failure Several of the slides appear to have occurred in the clay substrate rather than in peat itself Need to invoke residual parameters in substrate or excess pore water pressure and/or water filled tension cracks to reduce F to unity

Stability Analysis Parametric Studies Given the very low effective overburden pressure F is much more sensitive to c than Φ See next two slides, both start from the parameters for Landgon Head quoted by Carling (c = 6.52 kpa, Φ = 14.45 o )

Langdon Head Peat depth 1.13 m Peat density 10.24 kn/m 3 Water level at ground level Gradient 7.8 degrees Φ 14.45 20 30 50 F 4.27 4.30 4.37 4.56

Langdon Head Peat depth 1.13 m Peat density 10.24 kn/m 3 Water level at ground level Gradient 7.8 degrees c 6.52 5 2.5 0 F 4.27 3.29 1.60 0.08

Stability Analysis Parametric Studies Given that c is established by projecting the Mohr-Coulomb envelope back to axis, it is thus intimately dependent on the interpretation of Φ In the light of uncertainties in testing as discussed in this presentation the reliability of calculated F is open to very serious question

The Future Questions raised about whether conventional strength parameters are appropriate to peat and even if they are our ability to measure them reliably Current research into mechanical behaviour of peat (direct simple shear / axial shear device see Ground engineering Dec 2007) may help What do we do in the meantime? Can we really continue to ignore tensile strength?