Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

Similar documents
Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report of Surface Burning Characteristics Test on Acoustical Panel

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Acoustical Surfaces, Inc.

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

We Identify and S.T.O.P. Your Noise Problems

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

SIGMADEK, LTD. FIRE TEST REPORT

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

Public Comment No. 2-NFPA [ Section No ]

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

FUNDERMAX GMBH FIRE TEST REPORT

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Report on Public Input June 2014 NFPA 101

File E Project 97SC January 21, 1998 REPORT

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Materials Testing by Gregory Havel

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

File Ex643 Project 95NK34821 Project 96NK19119 Project 97NK2995 Project 98NK20794 Project 99NK21353 *Project 03NK33

Public Comment No. 1-NFPA [ Section No ]

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

SOUTHWEST RESEARCH INSTITUTE

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

F, T, L and W Ratings - What are the Code & Testing Requirements?

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

First Revision No. 6-NFPA [ Section No. 2.2 ]

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

CERTIFICATE OF COMPLIANCE

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

Standards Update Notice (SUN) Issued: February 2, 2017

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

Fire and Life Safety Requirements San Mateo City Special Events

NF X : Parts 1, 2, 3, 4 & 5

BCTC CARPET TECHNICAL CENTRE

J-PRO TM Cable Support System

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

GUARDIAN FIRE TESTING LABORATORIES, INC.

UL 94 Flammability Ratings: Introduction

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Architectural 3-Part Specifications

PART 1 GENERAL 1.01 SUMMARY

June 20, 2011 PARTIES INTERESTED IN FIXED CONDENSED AEROSOL FIRE-EXTINGUISHING SYSTEMS

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

BS EN : 2001 & IEC :2000

Title: Indicative fire test. WF Report No: /A. Prepared for: Hoody Speaker Hoods Ltd

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

Issued: January 13, 2006 Revised: April 21, 2009 REPORT. Automatic Sprinklers. The Viking Corporation Hastings, MI

ISO/TS TECHNICAL SPECIFICATION. Fire detection and alarm systems Part 9: Test fires for fire detectors

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

CERTIFICATION BULLETIN

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

Second Revision No. 3-NFPA [ Section No. 2.3 ]

PART 1 GENERAL 1.01 SUMMARY


PART 1 GENERAL 1.01 SUMMARY

Transcription:

November 29, 2010 Revised: January 10, 2013 Revised: January 18, 2013 Mr. Herbert Wheeler Railtech Ltd. 325 Ave Lee, Baie-D Urf QC H9X 3S3 Canada Our Reference: Subject: R26549/09CA56627 Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd Dear Mr. Wheeler: This is a Report summarizing the results of a test conducted under a preliminary investigation identified as Assignment No. 09CA56627. GENERAL: Preliminary investigations are initiated to obtain information with respect to a product or products prior to submittal to UL LLC (UL) for Investigation, Classification and Follow-Up Service. This Report does not constitute evidence of such a submittal to UL. The results relate only to items tested. METHOD: Each test was conducted in accordance with Standard ANSI/UL723, Tenth Edition, dated September 13, 2010, "Test for Surface Burning Characteristics of Building Materials", (ASTM E84-11). The test determines the Surface Burning Characteristics of the material, specifically the flame spread and smoke developed indices when exposed to fire.

The maximum distance the flame travels along the length of the sample from the end of the igniting flame is determined by observation. The Flame Spread Index of the material is derived by plotting the progression of the flame front on a time-distance basis, ignoring any flame front recession, and using the equations described below: A. CFS = 0.515 A T when A T is less than or equal to 97.5 minute-foot. B. CFS = 4900/(195-A T ) when A T is greater than 97.5 minute-foot. Where A T = total area under the time distance curve expressed in minute-foot. The Smoke Developed Index (SDI) is determined by rounding the Calculated Smoke Developed (CSD) as described in UL 723. The CSD is determined by the output of photoelectric equipment operating across the furnace flue pipe. A curve is developed by plotting the values of light absorption (decrease in cell output) against time. The CSD is derived by expressing the net area under the curve for the material tested as a percentage of the area under the curve for untreated red oak. The CSD is expressed as: CSD = (A m /A ro ) x 100 Where: CSD = Calculated Smoke Developed A m = the area under the curve for the test material. A ro = the area under the curve for untreated red oak. SAMPLES: The samples utilized in this investigation were neither prepared nor selected by a Laboratories' representative such that no verification of composition can be provided. Sample Description Test No. System 1 Skyfold panels no finish Due to the rigidity of the test samples, supplementary means of support was not required.

RESULTS: The results are tabulated below are considered applicable only to the specific samples tested. Data sheets and graphical plots of flame travel versus time and smoke developed versus time are also enclosed. Table 1: Test Summary Test No. Test Code Sample Description 1 11241008 CFS Calculated Flame Spread FSI Flame Spread Index CSD Calculated Smoke Developed SDI Smoke Developed Index Skyfold panels no finish 0 0 0.0 0

The Classification Marking of UL on the product is the only method provided by UL to identify products which have been produced under its Classification and Follow-Up Service. No use of a Classification Marking has been authorized as a result of this investigation. Since the anticipated work has been completed, we have instructed our Accounting Department to terminate the investigation and invoice you for the charges incurred to date. Should you have any questions, please contact the undersigned. Very truly yours Reviewed by: Jamila Shawon (ext. 42607) James Smith (ext. 42666) Senior Project Engineer Staff Engineering Associate Fire Protection Division Fire Protection Division

Project: 09CA56627 File: R26549 TestCode: 11241008 Tested by: SCOTT KNIGHTON Engineer: JAMILA SHAWON Date: 2010-11-24 TEST METHOD: The test was conducted in accordance with UL 723, Tenth Edition. Client Name: RAILTECH LTD Test Duration 10 minutes Test No.: 1 Hot Test: No Mounting: Self Test Type: Developmental Burn-Out Required: No Test Sample: Skyfold panels no finish FLAME SPREAD RESULTS Flame Spread Data Distance (Feet) Time (Sec) Calculated Flame Spread (CFS): 0.00 Flame Spread Index (FSI): 0 Time to Ignition (sec): None Maximum Flame Spread (ft): 0.0 Area Under the Flame Spread Curve (ft.-min): 0.0 SMOKE RESULTS Calculated Smoke Developed (CSD): 0.0 Smoke Developed Index (SDI): 0 Area Under the Smoke Curve (Obs-min.): 0.00 Area Under Red Oak Curve (Obs-min.): 73.87 Post-Test Observations Discoloration (Feet From Burner): 8 ULS-00723-BIKT-DataSheet-2001 Form Issued: 2004-01-28 Form Page 5 Form Revised: 2007-15-10 Form Copyright 2007 Underwriters Laboratories Inc. Only those products bearing the UL mark should be considered as being covered by UL

Obscuration (%) Flame Spread (feet) Flame Spread / Smoke Results RAILTECH LTD Skyfold panels no finish 100 90 80 70 60 50 40 30 20 10 0 % Obscuration Flame Spread 0 2 4 6 8 10 Time (Minutes) 20 18 16 14 12 10 8 6 4 2 0 Test Num.: 1 Flame Spread Index: 0 R26549 / 09CA56627 Smoke Developed Index: 0 11241008 Max. Flame Spread (ft.): 0.0