RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Similar documents
RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

SIGMADEK, LTD. FIRE TEST REPORT

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

FUNDERMAX GMBH FIRE TEST REPORT

We Identify and S.T.O.P. Your Noise Problems

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

ENGINEERING EVALUATION

Fire Performance of Translucent Systems

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Test Report No. AJFS FF Date: OCT.17, 2018 Page 1 of 6

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

CAN/ULC-S102 Surface Burning Characteristics of "Digitally Printed Aluminum Siding" Coated Aluminum

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Refrigerating Appliance DOE Test Report

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

Report of Surface Burning Characteristics Test on Acoustical Panel

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Report of Surface Burning Characteristics Tests on Samples As Submitted By Jotun UAE Ltd (LLC)

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Railtech Ltd.

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

Report of Surface Burning Characteristics Tests on Skyfold Panel Samples As Submitted By Railtech Ltd

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Textures 3D

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Tile-diy LLC

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Report Of Surface Burning Characteristics Tests On PVC Sheeting As Submitted By Jain (Americas) Inc.

Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

PERFORMANCE TEST REPORT. Rendered to: Metal Building Manufacturers Association Cleveland, Ohio

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

TEST REPORT. Contact No: SAMPLE NOT DRAWN BY OUR LABORATORY. THE RESULTS RELATE ONLY TO THE ITEMS TESTED

Abrasion Resistance of Fluoropolymer and polyester Coatings

GUARDIAN FIRE TESTING LABORATORIES, INC.

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

Declaration of Conformity

Materials Testing by Gregory Havel

1.0 INTRODUCTION 2.0 CLASSIFICATION CRITERIA

Acoustical Surfaces, Inc.

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Refrigerating Appliance ErP Test Report

BS EN : 2001 & IEC :2000

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Classification of Fire Performance of Wall and Ceiling Lining Materials

Public Comment No. 2-NFPA [ Section No ]

NF X : Parts 1, 2, 3, 4 & 5

BCTC CARPET TECHNICAL CENTRE

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Fire Risk and CODE Compliance For Fabric Wrapped Acoustic Panels

Guidance Note. 3. Fire Propagation and flame Flame Spread in in Powder Coatings. Abrasion Resistance of Fluoropolymer and polyester Coatings

Review Fire Test Report

FLASHLIGHT ANSI STANDARDS

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly


ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Food Service Technology Center

PERFORMANCE EVALUATION TEST REPORT. Rendered to: GREENFIELD MANUFACTURING COMPANY. PRODUCT: Hanger Screws

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

for Walmart suppliers. About Bureauu Veritas laboratories in building and Phase 1: Pre- Assessment until the factory Phase 2: Initial Assessment

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

This document is a preview generated by EVS

Test Report. Appliance EMF Testing

Transcription:

REPORT NUMBER: 3189147COQ-002 ORIGINAL ISSUE DATE: September 30, 2009 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5 PRODUCT EVALUATED: Broadway Acoustical Tile EVALUATION PROPERTY: Surface Burning Characteristics Report of testing Broadway Acoustical Tile for compliance with the applicable requirements of the following criteria: ASTM E84-09, Standard Test Method for Surface Burning Characteristics of Materials. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 1

Report No. 3189147COQ-002 Page 2 of 14 1 Table of Contents PAGE 1 Table of Contents...2 2 Introduction...3 3 Test Samples...3 3.1 SAMPLE SELECTION...3 3.2 SAMPLE AND ASSEMBLY DESCRIPTION...3 4 Testing and Evaluation Methods...4 4.1 TEST STANDARD...4 5 Testing and Evaluation Results...5 5.1 RESULTS AND OBSERVATIONS...5 6 Conclusion...6 APPENDIX A Data Sheets...6 Pages REVISION SUMMARY

Report No. 3189147COQ-002 Page 3 of 14 2 Introduction Intertek Testing Services NA Ltd. (Intertek) has conducted testing for Radial Engineering Ltd., to evaluate the surface burning characteristics of Broadway Acoustical Tile. Testing was conducted in accordance with the standard methods of ASTM E84-09, Standard Test Method for Surface Burning Characteristics of Materials. This evaluation began September 21, 2009 and was completed September 30, 2009. 3 Test Samples 3.1. SAMPLE SELECTION Samples were submitted to Intertek directly from the client and were not independently selected for testing. The sample materials were received at the Evaluation Center on September 2, 2009 and September 29, 2009. 3.2. SAMPLE AND ASSEMBLY DESCRIPTION The sample products were described by the client as Broadway Acoustical Tile panels. The samples consisted of a formed inorganic semi-rigid fiberglass panel wrapped with polyester fabric. Three fabric colours were submitted for testing beige, grey, and black. Each panel measured 22 inches wide by 4 feet long by 2 inches thick. For each trial run, six 4 ft. panels of the same colour were placed on the upper ledge of the flame spread tunnel with the fabric side oriented towards the flame and butted together to form the required 24 ft. sample length. A layer of 6 mm reinforced cement board was placed over top of the samples, the tunnel lid was lowered into place, and the samples were then tested in accordance with ASTM E84-09.

Report No. 3189147COQ-002 Page 4 of 14 4 Testing and Evaluation Methods 4.1. TEST STANDARD The results of the tests are expressed by indexes, which compare the characteristics of the sample under tests relative to that of select grade red oak flooring and asbestos-cement board. (A) Flame Spread Classification: This index relates to the rate of progression of a flame along a sample in the 25 foot tunnel. A natural gas flame is applied to the front of the sample at the start of the test and drawn along the sample by a draft kept constant for the duration of the test. An observer notes the progression of the flame front relative to time. This information is plotted on a graph (flame spread curve). The test apparatus is calibrated such that the flame front for red oak flooring passes out the end of the tunnel in five minutes, thirty seconds (plus or minus 15 seconds). Calculations: ASTM E84-09 4900 According to the test standard, the flame spread classification is equal to 195 A T when A t is the total area beneath the flame spread curve, if this area exceeds 97.5 minute feet. If the area beneath the curve is less than or equal to 97.5 minute feet the classification becomes 0.515 x A t. (B) Smoke Developed: A photocell is used to measure the amount of light, which is obscured by the smoke passing down the tunnel duct. When the smoke from a burning sample obscures the light beam, the output from the photocell decreases. This decrease with time is recorded and compared to the results obtained for red oak, which is defined to be 100. Calculations: 10,000 SmokeIntegration Unrounded Smoke Developed Index = x100 650

Report No. 3189147COQ-002 Page 5 of 14 5 Testing and Evaluation Results 5.1. RESULTS AND OBSERVATIONS (A) Flame Spread The resultant flame spread classifications are as follows: (classification rounded to nearest 5) Broadway Acoustical Tile Flame Spread Flame Spread Classification Run 1 Beige Tile 9 10 Run 2 Grey Tile 19 20 Run 3 Black Tile 21 20 (B) Smoke Developed The areas beneath the smoke developed curve and the related classifications are as follows: (For smoke developed indexes 200 or more, classification is rounded to the nearest 50. For smoke developed indexes less than 200, classification is rounded to nearest 5) Broadway Acoustical Tile Smoke Developed Smoked Developed Classification Run 1 Beige Tile 145 145 Run 2 Grey Tile 145 145 Run 3 Black Tile 214 200 (C) Observations After ignition the polyester fabric quickly caught fire and melted onto the tunnel floor. The flame spread traveled to its respective point and then receded to its original flame front position. This was the case for all three test runs.

Report No. 3189147COQ-002 Page 6 of 14 6 Conclusion The samples of Broadway Acoustical Tile, submitted by Radial engineering Ltd., exhibited the following flame spread characteristics when tested in accordance with ASTM E84-09, Standard Test Method for Surface Burning Characteristics of Materials. Sample Material Flame Spread Classification Smoke Developed Classification Run 1 Beige Tile 10 145 Run 2 Grey Tile 20 145 Run 3 Black Tile 20 200 The conclusions of this test report may not be used as part of the requirements for Intertek product certification. Authority to Mark must be issued for a product to become certified. INTERTEK TESTING SERVICES NA LTD. Tested and Reported by: Gerry Loverro Technician Construction Products Testing Reviewed by: Greg Philp Reviewer, Fire Testing GL G:\Building\Fire Testing\Flamespread ltrs & rpts\2009\radial Engineering Ltd. 3189147 Sept 09 S102.doc

Report No. 3189147COQ-002 Page 7 of 14 APPENDIX A DATA SHEETS

Report No. 3189147COQ-002 Page 8 of 14 ASTM E84-09 DATA SHEETS Run 1

Report No. 3189147COQ-002 Page 9 of 14 ASTM E84-09 DATA SHEETS Run 1

Report No. 3189147COQ-002 Page 10 of 14 ASTM E84-09 DATA SHEETS Run 2

Report No. 3189147COQ-002 Page 11 of 14 ASTM E84-09 DATA SHEETS Run 2

Report No. 3189147COQ-002 Page 12 of 14 ASTM E84-09 DATA SHEETS Run 3

Report No. 3189147COQ-002 Page 13 of 14 ASTM E84-09 DATA SHEETS Run 3

Report No. 3189147COQ-002 Page 14 of 14 REVISION SUMMARY DATE PAGE SUMMARY September 30, 2009 all Original Issue Date