ASCENDANT CONVENTIONAL COOLING, ACTIVE DESICCANT DEHUMIDIFICATION SYSTEM ASCENDANT LOW DEW POINT EFFICIENT & EFFECTIVE

Similar documents
HEALTHCARE SURGERY VENTILATION HUMIDITY CONTROL

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

CONTROLLED CHILLED BEAM PUMP MODULE

Benefits Offered by Passive Dehumidification Wheel Speed Control

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

CONTROLLED CHILLED BEAM PUMP MODULE

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Dehumidifying with Dedicated Outdoor Air

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

100% Outdoor Air Dehumidification Methods

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Trane CDQ Desiccant Dehumidification

THE ULTIMATE ROOFTOP SOLUTION

To Keep Docs Cool, Dry and Happy

Energy Recovery Ventilation

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

RT-OA TM Rooftop Outdoor-Air (DOAS)

Humidity Control & Psychrometrics

Active desiccant integration with packaged rooftop HVAC equipment

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AHRI 920 Performance Rating and Comparisons of DX-DOAS Unit Efficiency

APPLICATION GUIDE BEAMS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Trane Performance Climate Changer Air Handlers. An air handler for every need.

» WITH REGASORP ROTARY HEAT EXCHANGER

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Liquid desiccant dehumidification systems. Product guide

Field Test and Performance Verification: Integrated Active Desiccant Rooftop Hybrid System Installed in a School

Appendix 13. Categories of Cooling and Heating systems

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Energy Recovery with Cooling and Heating

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

DADANCO Technical Paper

Designing Energy Efficient Outdoor Air Systems

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

EU Air Handling Units with SEMCO EXCLU-SIEVE

Armstrong Cool-Fog Systems

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Adding More Fan Power Can Be a Good Thing

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

National Institutes of Health Building 37 Modernization Bethesda, Maryland MECHANICAL DEPTH EXISTING MECHANICAL SYSTEM

Pharmaceutical Facility Design

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

Energy Recovery Ventilators

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

Section 4 of 6 DOAS Core Technologies

ENGINEERING. Edition No. 13 October 2002

DES CHAMPS PRODUCTS 85% 4,400 CFM

2009 IECC Commercial Mechanical Requirements

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Energy Recovery with Cooling and Heating Model ERCH

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

Adsorption Chillers Energysmart Green Cooling

EarthWise System Seminar

Munters Heat Exchangers

HCU Systems for Industrial Applications. Rob Smith National Accounts Manager March 7, 2011

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Managing HVAC in High Performance Buildings

CHAPTER 4. HVAC DELIVERY SYSTEMS

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

Summary Comparison of Simulation Program Features

ALL PRODUCTS BROCHURE

HVAC 101. H V A C S y s t e m s

healthy comfort Indoor Air Quality Solutions

Daikin Blueprint: Delivering Hot Water with a Chiller

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

RoofPak Applied Rooftop Systems

Heat pump and energy recovery systems

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Field Test of Combined Desiccant-Evaporator Cycle Providing Lower Dew Points and Enhanced Dehumidification

COMcheck Software Version Mechanical Compliance Certificate

Transcription:

LOW DEW POINT EFFICIENT & EFFECTIVE ASCENDANT CONVENTIONAL COOLING, ACTIVE DESICCANT DEHUMIDIFICATION SYSTEM ASCENDANT

HVAC systems have a major impact on: Specialized solution for the high demands of healthcare applications HVAC systems for hospital and healthcare facilities have special requirements because of the susceptibility of patients to infection. Heating and ventilation systems play an important part in providing a clean, safe and comfortable environment for patient recovery. Infection control Hazard control Internal climate control Building energy consumption Ascendant solution includes: Active desiccant hybrid system High efficiency systems An improvement to the building s conventional HVAC System operation and energy consumption INDOOR AIR QUALITY Category 2

Specific Healthcare Demands Healthcare facilities need more than just heating and ventilation. FläktGroup Semco can deliver equipment and complete systems for control of infection, air movement, and odor, yet maintain temperature, humidity, air quality and noise at superior comfortable levels for patients and staff. Operating theaters specifically have unique HVAC design challenges: VENTILATION AND AIR MOVEMENT Minimum of 4 air changes of outdoor air with a total of 20 air changes (ASHRAE 170-2013 table) Regardless of the amount outdoor air used total energy recovery should be utilized in almost every region in the US. (ASHRAE 90.1-2013 Table 6.5.6.1-2) OPERATING ROOM HUMIDITY CONTROL Must be able to maintain space humidity less than 60% RH with a commonly requested temperature of 65 F. (AIA/ASHRAE Guidelines) Both low end temperature and humidity must be achievable simultaneously This corresponds to a space dew point of approximately 40 F (not achievable with conventional chilled water system). 3

THE ASCENDANT SERIES FROM FLÄKTGROUP SEMCO Ascendant is a conventional cooling active desiccant dehumidification system, performance optimized to deliver and control low dew point air while minimizing regeneration energy input in compliance with ASHRAE/ AIA guidelines. Ascendant easily allows a design consultant compliance with ALL ASHRAE/AIA guideline conditions while using far less energy than conventional approaches that do not achieve a hospital s required low space dew point requirements. OFFERING THE GREATEST DEHUMIDIFICATION CAPACITY Ascendant provides more than three times the dehumidification capacity/cfm compared to customized DX cooling systems, enabling supply of much lower dew points (see below). TIGHT HUMIDITY AND TEMPERATURE CONTROL Low space dew point conditions are easily achieved and tightly controlled by the customized control algorithms, factory installed sensors, and an on-board DDC controller. REDUCED COOLING TONS Fewer tons of mechanical cooling capacity are required to achieve a low supply air dew point - up to 60% less cooling capacity required compared to custom DX systems. Many hours exist where dehumidification is accommodated with only the active desiccant wheel and no cooling is required. 60 LIMIT OF 55 CONVENTIONAL SYSTEM 80 70 60 50 48 Dew Point 45 40 ASCENDANT 50 40 CAPABLE MOISTURE 35 SUPPRESSION 30 30 25 20 Dew Point 20 20 15 5-5 0-20 -15-0 -20-15 - -5 0 5 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 0 5 1 115 120 DRY BULB TEMPERATURE F 4 COMMON OPERATING ROOM DESIGN RANGE SUBSTANTIAL ENERGY SAVINGS Ascendant operates with 25% to 50% less energy cost than other conventional dehumidification systems as a result of improved cooling efficiency (higher suction temperatures) and by shifting much of the latent load from electrically driven vapor compression over to lower cost regeneration energy. ASCENDANT IS DESIGNED TO: Offer substantial energy and first cost savings Ensure hospitals are able to operate continuously around the clock Improve hygiene by ensuring that the ASHRAE required final filters remain dry NO RETURN AIR PATH NEEDED While total energy recovery is an important option when return air is available, it is not required to achieve efficient operation. TRUE 3Å WHEEL SEMCO s True 3Å wheel (optional) decreases outdoor air cooling tons by up to 60%. It limits contaminant carry-over to less than 0.045%, and has been used in hospital applications for decades. 65 HVAC SYSTEM SUPPLY DISCHARGE TO ACHIEVE OPERATING ROOM DESIGN RESULT Ascendant vs. Conventional Cooling Approach NON-SURGICAL HOSPITAL ROOM DESIGN RANGE 1 0 90 HUMIDITY RATIO (W)-GRAINS OF MOISTURE PER POUND OF DRY AIR 7000 GRAINS PER POUND

126ºF 189 gr Regen Out ASCENDANT FLOW SCHEMATIC Active Dehumidification Wheel 190ºF Regeneration Heater 90ºF 120 gr Regeneration Regen Fan,200 cfm 9,070 cfm 8,870 cfm Dehumidified Air Outdoor Air * 72ºF 54ºF 88ºF 61 gr 20 gr Bypass Air 62 gr 54ºF 1,130 cfm Cooling Coil 61 gr Bypass Damper Outdoor Air 4,879 cfm Supply Fan,000 cfm Supply Air 83.9ºF 25 gr * Based on optional Total Energy Recovery wheel to lower required cooling input HOW IT WORKS: The Ascendant system processes outdoor and/or return air streams to a moderate leaving coil temperature condition (when needed), thereby delivering saturated air to the active desiccant wheel which promotes highly efficient moisture adsorption, further depressing the supply air humidity content to very low dew points By employing moderate chilled water or refrigerant temperatures, the efficiency of the cooling system employed is high. (This is in sharp contrast to refrigeration based dehumidification systems which rely on low suction temperatures and very deep cooling coils to achieve lower dew points.) An integral modulating bypass damper allows the cool, moderately dry air leaving the cooling coil to be mixed with the appropriate quantity of warm, very dry air leaving the dehumidification wheel to deliver the required supply air dew point. If tight temperature control is also required, a small sensible only post cooling coil is employed. Regeneration of the desiccant wheel is also achieved with high energy efficiency. A typical regeneration airflow quantity is only 20% - 40% of the supply airflow volume. Only moderate regeneration temperatures (140 F to a maximum of 200 F) are required, allowing the use of hot water, steam, direct fired gas or waste heat (i.e. byproduct of a power generation (CHP)). For applications where an exhaust airstream is available (i.e. hospital operating theaters) preconditioning the outdoor air with FläktGroup Semco total energy recovery is highly recommended since it substantially increases overall system energy efficiency and substantially reduces pre-cooling input requirements. It also provides valuable winter season preheat and humidification. 5

Operating Theater Design Analysis: Conventional vs. Ascendant Example: Fifteen operating rooms designed in accordance with FGI/AIA/ASHRAE guidelines requiring 3,333 cfm each using 20% outdoor air Case 1: Total Energy preconditioning to Conventional AHU Operating theaters conditioned to achieve 65ºF and not more than 60% RH as required for Delivery Rooms by AIA/ ASHRAE guidelines Coldest possible chilled water used (40ºF at the chiller), and deepest cooling coil ( row) to achieve 48ºF air off of the coil Air reheated to 59ºF to accommodate sensible load in the space Total energy recovery is utilized to precondition the outdoor air portion as per ASHRAE 90.1 Preconditioned air (,000 cfm) is delivered to conventional AHUs supplying enough air to provide 3,333 cfm to each of the 15 operating rooms to achieve the required 25 air changes/hr. Conventional Approach: Requires 150 Tons, 600K BTU Reheat 0 65 90 Outdoor air Leaving 60 TE Wheel 80 (76 F, 72 grains) 70 55 Mixed air conditions entering AHU coil 60 Cooling coil 50 (68 F, 60 grains) supply condition 50 (48 F, 50 grains) OR space conditions 45 65 F at 60% RH 40 40 AHU supply 35 condition (59 F, 50 grains) 30 30 25 20 20 15 5 REHEAT ENERGY 0 600,000 BTU/HR 0 0 5 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 0 5 1 115 120 DRY BULB TEMPERATURE F 6 Cooling Capacity Required (150 tons) ENTHALPY (h) -BTU PER POUND OF DRY AIR 15 20 25 30 70 75 Outdoor air entering TE Wheel (95 F, 120 grains) 130 120 1 HUMIDITY RATIO (W)-GRAINS OF MOISTURE PER POUND OF DRY AIR 7000 GRAINS PER POUND

Case 2: Ascendant preconditioning to Conventional AHU Operating theaters operated in an attempt to achieve 65ºF and 60% RH as required for Delivery Rooms by AIA/ ASHRAE guidelines (Note: Colder room conditions often desired for surgeon comfort and lower space humidity can be easily achieved with Ascendant) Traditional chilled water used (45ºF at the chiller), thereby increasing chiller efficiency and sensible only cooling coil (4 row) in AHUs No reheat required to deliver the 59ºF to the space Total energy recovery is utilized to precondition the outdoor air portion as per ASHRAE 90.1 combined with integrated active desiccant to deliver very dry outdoor air to each AHU. All latent load handled by Ascendant so AHU coils are sensible only Ascendant Approach: Requires only 58 Tons, No Reheat 65 0 90 Outdoor air Leaving 60 TE Wheel (76 F, 72 grains) 80 55 OR space conditions 65 F at 60% RH 70 60 50 50 45 AHU supply 40 condition 40 (59 F, 50 grains) Outdoor air leaving 35 ASCENDANT (20 tons) 30 30 Mixed air conditions (78 F, 38 grains) entering AHU coil 25 20 20 (68 F, 50 grains) 15 5 0 NO REHEAT ENERGY NEEDED 0 0 5 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 0 5 1 115 120 DRY BULB TEMPERATURE F Cooling Capacity Required (38 tons) ENTHALPY (h) -BTU PER POUND OF DRY AIR 15 20 25 30 70 75 Outdoor air entering TE Wheel (95 F, 120 grains) 130 120 1 HUMIDITY RATIO (W)-GRAINS OF MOISTURE PER POUND OF DRY AIR 7000 GRAINS PER POUND 7

System Comparison: Conventional vs. Ascendant Outdoor Air Preconditioning Case 1: Conventional Case 2: Ascendant Preconditioning Airflow provided (for ten ORs),000 cfm,000 cfm Pretreatment used Total energy recovery Total recovery, pre-cooling, active dehumidification Cooling capacity required (at peak) None required 20 tons (1) Regeneration capacity required (at peak) None required 352,000 btu/hr Supply Air to Operating Rooms Airflow provided (for ten ORs) 50,000 cfm 50,000 cfm Outdoor air percentage 20% 20% Cooling capacity required 150 tons (2) 38 tons (1) Chilled water temperature required 40 F 45 F Reheat energy required 594,000 btu/hr None required Total System Summary Cooling capacity required 150 tons (2) 58 tons (1) Reheat/regeneration energy required 594,000 btu/hr 352,000 btu/hr (peak, less at part load) Total fan HP estimate 59 BHP 62 BHP Dehumidification season cooling electrical cost (3) ($.08/KWH) $32,312 $11,190 Dehumidification season heat ($ MMBTU) $21,408 $12,900 Total Operating Energy Cost Estimate (Dehumidification season) (1) Reflects higher chiller efficiency with 45 F water. (2) Reflects lower chiller efficiency with 40 F water. (3) Assumes Philadelphia weather data, 24 hour/day operation, $.08/KWH, $/MMBTU steam $53,720 $24,090 Results from Example Analyses Numerous important design advantages were recognized when the outdoor air delivered to the operating theaters was preconditioned by the Ascendant technology. When compared to the conventional approach, the Ascendant system achieved the desired space humidity conditions using 61% fewer tons of cooling capacity (58 vs 150), eliminated approximately 600,000 BTUs of reheat energy and cut the cost of operation by 55%. 8 The cooling efficiency is improved with Ascendant since the desired air temperature leaving the coil could be achieved using traditional 45 F chilled water while the conventional approach needed chilled water at 40 F or below. Chillers operated to deliver 40 F require substantially more energy input (KW/ton) then do chillers delivering water at 45 F. Many hospitals deliver these inefficient chilled water conditions to the entire facility simply because the need them for the operating theaters. Ascendant solves that problem.

Case 3: Ascendant Exceeds AIA guidelines at the Desired Space Temperatures Perhaps the greatest benefit offered by the Ascendant technology is the additional dehumidification capacity provided so that HVAC systems are able to meet the required space humidity conditions within the operating theaters even when space temperatures colder than 65 F are desired. The high lighting intensity and machinery common in today s operating theaters combined with protective clothing typically requires space temperatures at or below 62 F for surgeons comfort during strenuous procedures. Another key reason for providing additional dehumidification capacity is to accommodate latent loads infiltrating from higher humidity spaces adjacent to the OR when the automatic doors are opened before and during surgery. Experience has shown that these latent loads are often missed during the design process which is problematic since they are significantly greater than those associated with the occupants. As shown within the Case 3 psychrometric chart (below), Ascendant can easily maintain OR space conditions down to 62 F and below while achieving the desired 50% relative humidity level. This is possible due to the Ascendant system s ability to deliver air with a dew point as low as 20 F. Surprisingly, these conditions can be efficiently maintained without the need for substantially more cooling or regeneration energy input than required by Case 2 and substantially less than required by the conventional approach shown in Case 1. ENTHALPY (h) -BTU PER POUND OF DRY AIR 15 20 25 30 Cooling Capacity Required (50 tons) 65 60 Outdoor air 80 Leaving TE Wheel 55 (76 F, 72 grains) 70 60 50 OR space conditions 62 F at 45% RH 50 45 40 40 35 30 30 AHU supply condition 25 (55 F, 35 grains) 20 20 Mixed air conditions Outdoor air leaving 15 entering AHU coil ASCENDANT (25 tons) 5 (66 F, 35 grains) (85 F, 22 grains) 0 NO REHEAT ENERGY NEEDED 0 0 5 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 0 5 1 115 120 DRY BULB TEMPERATURE F 70 Outdoor air entering TE Wheel (95 F, 120 grains) 130 120 1 0 90 HUMIDITY RATIO (W)-GRAINS OF MOISTURE PER POUND OF DRY AIR 7000 GRAINS PER POUND 9

DEDICATED OUTSIDE AIR SYSTEM WITH OPTIONAL INTEGRATED TOTAL RECOVERY Pre-treats downstream air handling systems Optional benefit of total energy recovery for more energy efficient operation Provides preheat and humidification during the heating season 17 16 18 15 12 14 3 2 11 13 7 5 1 6 4 4 8 = Optional add-on TOTAL CONDITIONING SYSTEM Incorporates post cooling and final high efficiency filtration to allow for independent control of both temperature and humidity, providing total conditioning without supplemental air handlers to laboratories or large operating theaters. 7 14 15 12 11 13 5 1 2 Outdoor Air Damper Outdoor Air Filter Optional True 3Å Wheel Wheel Bypass Damper Heating Coil Pre & Post Cooling Coil 6 4 8 1 2 3 4 5 6 9 6 7 8 9 11 12 Active Desiccant Wheel Supply Air Fan Final Filtration Regen Inlet Damper Regen Air Filtration Regeneration Source 13 14 15 16 17 18 Recirculation Damper Regen Fan Optional Return Air Opening Return Air Filtration Exhaust Air Fan Exhaust Air Damper

STANDARDS AND OPTIONS STANDARD FEATURES Active Desiccant Wheel Fluted media composed of porous inorganic fiber impregnated with high quality adsorbent Driven using lube-free chain for longevity and ease of maintenance Active Desiccant System DX or chilled water pre-cooling coils Regeneration heat - hot water, steam, electric, or gas (indirect and direct) Wheel bypass damper lowering wheel pressure drop and providing greater control over supply temperature and humidity SEMCO PANL Solutions Double-wall panel construction (4 inches thick with 18-gauge outer skin) Double-wall removable panels provided for large internal components Gasketed double-wall access doors for all compartments Supply and Regeneration Air Fans Direct drive plenum supply and SWSI regeneration fans Variable frequency drives Filter Sections 30 percent efficient filters are provided for supply and regeneration air streams OPTIONAL FEATURES Recirculation damper to allow regeneration heat source to be used for supply air during winter operation Post-cooling coil if cooler supply air is required Process Heating MERV 11-14, HEPA, and ULPA high efficiency final filters on supply side Return fan for partial outdoor air systems Total energy recovery wheel when exhaust air is available to reduce required cooling input Custom options and configurations are supported to meet your unique requirements DDC CONTROLS Advanced integrated DDC controls are utilized to optimize the performance of Ascendant to achieve the desired supply air humidity and temperature conditions while minimizing energy consumption. Five standard parameters that are controlled: 1. The fraction of the supply airflow that is processed by the active dehumidification wheel and the integral modulating bypass damper 2. The temperature of the air leaving the pre-cooling coil 3. The regeneration energy used (temperature) 4. The supply airflow delivered 5. The regeneration airflow utilized UNIT SIZES AND DIMENSIONS Unit Size Airflow CFM Range Unit Height Unit Width Make up Air Unit Length Dedicated Outside Air System with True 3Å Wheel Unit Length Total Conditioner Unit Length 005 2,720-5,500 62 2.25 259 364.5 351 009 3,740-8,500 74 114.25 259 380.5 358.75 013 6,130 -,500 88 114.25 263 402.25 360.75 018 7,600-15,000 0 138.25 274.25 420 368.75 024 9,600-20,000 112 150.25 297.75 462.5 387.5 11

ASCENDANT APPLICATIONS Ascendant 5 APPLICATION REFERENCES Odessa Medical Center...Health Care...Ascendant 13...DOAS...Lubbock, TX Laughlin Memorial...Health Care...Ascendant 5...Total Conditioning...Knoxville, TN Zeledyne...Industrial Mfg...Ascendant 9...DOAS...Nashville, TN Carlex...Industrial Mfg...Ascendant 9...DOAS...Nashville, TN Red Star Yeast...Food Processing...Ascendant 9...DOAS...Clive, IA Hilmar Cheese...Food Processing...Ascendant 9...Total Conditioning...Lubbock, TX Since Ascendant can produce substantially drier air the dehumidification capacity offered at a given airflow is many times greater. As a result it can typically be operated with only one third to one forth the airflow required by more conventional systems. The Carnegie Mellon Intelligent Workplace employs an Ascendant to dehumidify ventilation air to solve serious condensation issues on their passive chilled beams experienced with a prior, more conventional system. 12

DELIVERING AIR DEHUMIDIFIED OVER A WIDE RANGE TO HANDLE FLUCTUATIONS IN LATENT LOADS. A VARIETY OF APPLICATIONS Ascendant is ideal for hospital operating rooms and much more! Delivering extremely dry outdoor air to manage the heavy infiltration load in hot/humid locations, Ascendant improves comfort while extending the life of furnishings and greatly reducing the risk of mold and mildew. Dry air storage: Warehouse, Cave Storage To preserve products, avoid rust and prevent condensation, the need for cooling and heating of dry air storage spaces can be avoided if effective active dehumidification is employed. Relative humidity is a function of both moisture and temperature. Unheated warehouses and cave storage result in high RH conditions and potential condensation. Warm, very dry air delivered by Ascendant can substantially reduce your operation costs. Tight Humidity Control: Archives, Museums, Libraries Archives, museums and libraries exist to preserve documents and artifacts avoiding any preventable, premature damage. Ascendant can significantly extend the life of the items you are trying to preserve by consistently maintaining the RH at approximately 50% avoiding swings over time. Humidity spikes can accelerate damaging chemical reactions and biological attack. Ascendant systems with post cooling can carefully track space conditions and precisely control them to consistent levels due to the high dehumidification capacity and advanced DDC controls. Drying Ventilation Air: Hotels/Condominiums There is a very high latent load associated with ventilation air and infiltration in hotels and condominiums located in humid climates. Ascendant can effectively deliver outdoor air at very low dew points allowing the ventilation air alone to control space humidity regardless of the internal sensible load. By deep drying the ventilation air, the packaged cooling units can be downsized, reducing the size of ductwork, noise produced, and energy consumption. Since the ventilation airflow is provided continuously, Ascendant provides substantial dehumidification even on cloudy, humid days when the call for space cooling is minimal. Low Dew Point Spaces: Food Processing, Manufacturing To minimize moisture and condensation in production areas, Ascendant provides an efficient solution. Unwanted moisture can make equipment under-perform, create hygiene concerns, and violate USDA codes, costing you money. Ascendant will give you peace of mind that your product will be protected in every step of its journey from production to storage, improving product quality and reducing waste. Condensate Avoidance: Chilled Beam Installations Active or passive chilled beam designs are most energy efficient when system fans are sized to deliver only outdoor ventilation air. Handling the latent load associated with people and infiltration with the outdoor air volume alone often requires dew points lower than what is achievable with conventional systems. Space humidity needs to be controlled well below the dew point of the water temperature delivered to the beams to avoid condensation. Ascendant can process three times the latent load of a custom refrigeration based DOAS allowing it to prohibit beam condensation using the minimum possible outdoor air quantity. 13

FLÄKTGROUP SEMCO PRODUCTS TO COMPLEMENT THE ASCENDANT TRUE 3Å ENERGY RECOVERY WHEEL Industry s highest recovery performance (AHRI Certified) and Recovery Efficiency Ratios (RER) Contaminant carry-over to less than.045% Anti-corrosion, anti-microbial antistick face coatings standard Extruded aluminum structural hub, spokes and rim system Available singly, in self-contained conditioning units, or as retrofits of existing wheels. NEUTON CONTROLLED CHILLED BEAM PUMP MODULE Zone level water control for chilled beams Proactive condensation control Provides load matching with only necessary amount of cooling/ heating that the space requires Variable speed pump maximizes energy savings Allows the beam coil to be dual temperature, maximizing the amount of both cooling and heating a beam can provide IQHC ACTIVE CHILLED BEAM Industry best capacity to energy consumption ratio Utilizes the lowest air and water pressure to enhance the overall energy benefit of chilled beams Universal duct and water connections for easy to installation Superior indoor air quality and energy efficiency. Working Together for Maximum Efficiency: Ascendant, NEUTON, & Chilled Beams Outdoor Air to Beams 68 F, 42 grains FAN COIL UNIT BEAM LOOP (multiple beams) BEAM LOOP (multiple beams) BEAM LOOP (multiple beams) 42 F 62 F 58 F 62 F 58 F 62 F 58 F 50 F SEMCO NEUTON (one of three) 42 F ASCENDANT DOAS PRIMARY PUMP 62 F 55 F 42 F BOILER CHILLER 14 * Component not supplied by FläktGroup Semco.

EXCELLENCE IN SOLUTIONS PRODUCTS FROM FLÄKTGROUP SEMCO EP/EPD SERIES Provides ultimate level of performance in the transfer of energy Preconditions air for a conventional air handler or can perform as an independent, integrated system with a variety of heating and cooling options Indoor or outdoor installation Airflow capacities range from 2,000 to 70,000 CFM PINNACLE PRIMARY VENTILATION SYSTEM Manages 0% of a building s ventilation, humidity, and temperature, while simultaneously reducing energy loads Dual wheel dedicated outside air system designed to ventilate and deliver air direct to space Ideal primary air system utilized to decouple latent load of the building with the least amount of air Supports ductwork reduction and central plant energy reduction FV SERIES High recovery efficiency with low pressure loss Designed for rooftop installation in but can easily be installed indoors and still provide a very quiet, continuous supply of fresh air Provides a healthy, comfortable indoor atmosphere in a cost efficient package Airflow capacities range from 600 to,000 CFM ECONET Reliable and efficient Air Handling Unit Heat recovery, heating and cooling air are integrated to form a common circuit resulting in a more compact ventilation unit. Hydronic recovery pump package perfect for when True 3Å is not specified Recovers and uses energy that is unusable in traditional systems. Econet influences the entire energy chain to greatly reduce the energy requirement. 15

Ascendant Health Care Sales Brochure - FlaktGroup Semco 2018-08 WWW.SEMCOHVAC.COM ASCENDANT / 20180815 FläktGroup SEMCO delivers smart and energy efficient Indoor Air and Critical Air solutions to support every application area. We offer our customers innovative technologies, high quality and outstanding performance supported by more than fifty years of accumulated industry experience. The widest product range in the market, and strong market presence in 65 countries worldwide, guarantee that we are always by your side, ready to deliver Excellence in Solutions. FläktGroup SEMCO Corporate Headquarters 1800 East Pointe Drive Columbia, Missouri 65201 USA 573.443.1481 sales.semco@flaktgroup.com To learn more about FläktGroup SEMCO offerings and to contact your nearest representative please visit www.semcohvac.com Copyright 2018 SEMCO LLC. All Rights Reserved. SEMCO embraces a policy of continuous development and improvement, the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied upon request on receipt of order. Pinnacle and SEMCO are a registered Trademarks of SEMCO LLC. Other trademarks and logos in this publication may be property of SEMCO, LLC, its subsidiaries or any of its related companies and/or other organizations or individuals. U.S. patented technology.