Equipment Interface Module Training

Similar documents
ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

THX9321 Prestige 2.0 and. THX9421 Prestige IAQ with EIM APPLICATION FEATURES PRODUCT DATA

RedLINK Connects RedLINK Wireless Comfort Systems

THX9321R5030/U Prestige 2.0 HD High-definition Color Touchscreen Thermostat, RedLINK enabled

Solve Complex Comfort Challenges.

VisionPRO 8000 with Wi-Fi

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Honeywell Steam Humidifier Operates independently to maintain optimal humidity

DDAC-1 deluxe digital atmosphere controller

RedLINK Wireless Comfort Systems. RedLINK Connects.

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

C-Stat 17-ZW User Instructions

PRO Installation. Touch Wi-Fi Thermostat

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

VisionPRO 8000 with RedLINK

PRO Installation. Thermostat Wi-Fi

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

PRO Installation. Touch Wi-Fi Thermostat

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

I/O ZONE 560/583 AND OPERATION MANUAL

WARNING IMPORTANT. iharmony Zoning System CONTROLS KITS AND ACCESSORIES. Installation Instructions for the iharmony Zoning System (10C16)

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Daikin ENVi Thermostat installation overview

Model Number(s): WiFi Thermostats: 8840, 8830, 8820, 8810 Models Tested: 8820 rev 1.04

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

Zone Perfect Plus. Zoning Systems USER S INFORMATION MANUAL. NOTE TO INSTALLER: This manual must be left with the equipment user.

Part Number Color Cool Current Dimensions -H x W x D (Inch) Voltage Description THM5320R1000 Gray 1.0 A running 8-1/8 x 8 x 1-7/8 18 to 30 Vac

EL-TSTAT-8820 Safety & Installation Instructions

SmartZone TM System Manual

Safety & Installation Instructions

Owner's Manual TABLE OF CONTENTS

AirCycler g2-k Installation & User s Guide

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

Model 1750A/ 1770A Dehumidifier Installation Instructions

Water Tank Level Monitor

1 DEALER DELIVERED SEE YOUR SAVINGS DEALER INSTALLED 2 CONVENIENT ACCESS

Installation and Operation Manual

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

F150E Media Air Cleaner

Installation, Start-Up, and Operating Instructions

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

TCI-W-U Series Wall Mounted Controller Installation and Operation Manual IOM-525

Thermostats Zoning Systems

RCS Residential Control Systems Inc.

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

READ AND SAVE THESE INSTRUCTIONS

B SERIES ELECTRIC FURNACE

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

T6 Pro Z-Wave. User Guide. Welcome. Need help? Get in touch. Programmable Thermostat

Guardian II Pipeline Washer B Instruction Supplement

Home WHOLE-HOME COMFORT SOLUTIONS. Bringing balance. Creating comfort.

Safety & Installation Instructions

Psychrologix Controller W/ DHC

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Wave Series. Installation and User Guide. PE950 Hand-Held Remote Transceiver PE650 Panel-Mounted Transceiver

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

tcu.z Commercial Programmable Thermostat Installation Instructions

Communicating Controls. Launch Training

OPERATING INSTRUCTIONS

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

Service Manual Models: Series 100 & 101

Installation Instructions Read and become familiar with these instructions before beginning installation.

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

CS027 User Instructions

Homeowner s Guide / 1

Installation, Operation and Service Manual

READ AND SAVE THESE INSTRUCTIONS

2017 Catalog Update. Contents

Lyric T6 & T6R Smart Thermostat

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Product Details. The following table shows the product information to help you set up Nest products in your system. BATTERIES INCLUDED?

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Wireless Solutions. Application Selection Guide

Safety & Installation Instructions

5.5. Other configuration parameters EXCEPTION CODES AUTO DIAGNOSTICS Zoning box control board

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

COMcheck Software Version Mechanical Compliance Certificate

prestige Control Application Supplement - TriMax

Installation Instructions

Thermostat TP42H01 User Manual

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

Your safety and the safety of others are very important.

VisionPRO Series with RedLINK. User Guide

Safety & Installation Instructions

Installation Instructions. SPANISH Installation Instructions. FRENCH Installation Instructions

Install Guide Customer Support: or Visit our website

Installation Instructions

O PE R AT I ON HO851G REVOLVING TRAY OVEN. MODEL HO851G GAS ML Pan ML Pan ML Pan ML Pan

Installation Instructions

System Installation Guide

Fisher LCP100 Local Control Panel

Zoning System Design Manual

Transcription:

Equipment Interface Module Training

EIM Module Basics Reasons to use EIM Modules: 1.)Not enough wires to thermostat or want to use wireless thermostat. 2.)Want to monitor system through honeywell 3.)Installing a humidifier, ventilator, dehumidifier 4.)Use of dry contacts for alarms, alerts, unit protection.

EIM Module Mounting Locations 1.)Mounting EIM Module on horizontal applications can be accomplished by mounting to supply or return air plenums. 2.)Mounting EIM Module on vertical applications can be accomplished by mounting to supply ductwork or walls in closet. 3.)Mounting EIM Module on package units can be accomplished by installing anywhere inside unit where water can not enter. Examples: mount on splitter inside, interior wall, heat strip compartment.

EIM Module Wiring 1.) If wiring 24 volts to thermostat Red and Common to be connected at R and C at the (TO THERMOSTAT) terminals on EIM Module. 2.)Wiring to equipment is standard connections: example Y to Y, G to G on EIM Module terminals. 3.) Wiring of discharge sensor to go to S2 terminals on EIM Module, note does not matter which wire goes to which.

EIM Module Wiring Cont 4.) Wiring of return air sensor to be connected to S1 terminals on EIM Module, note does not matter what wire goes to which terminal. 5.)Wiring of condensate safety switch must be connected to the S3 terminals, again does not matter which wires. 6.)Wiring of drain pan sensor (optional) must be connected to S4 terminals for normally closed circuit, and 24 volts to Red and Common

Programming Redlink for EIM Module 1.)Follow instructions that come up on screen when new thermostat is first installed or reset to factory default settings then follow instructions. 2.)Go through thermostat until thermostat reads:t-stat Controls an Equip Module:NO switch using arrow keys to yes. Next hit yes then next says to press connect at EIM Module. Press connect and wait to see green LED start flashing then go to thermostat and hit next. Should say connecting, once connected thermostat will say connected, hit next and you have now linked thermostat to Module.

Programming Continued 3.)Next screen on thermostat says connect redlink devices, this is where you connect all wireless devices. 4.)Continue through set up until thermostat says:wired Sensor on S terminals:no. Switch to yes using arrow keys and hit next. 5.)Next screen asks if wired remote indoor sensor:no leave at no these are not remote indoor sensors.

Programming Continued 6.)Next screen says:wired Return Sensor:no switch to yes and hit next. 7.)Next screen says:return Sensor eim terminal S1. Verify that you return sensor is wired to the S1 terminals on EIM Module. 8.)Next screen: Return Sensor type:10k, all wired sensors from honeywell are 10k just hit next.

Programming Continued 9.)Next screen:wired Discharge Sensor:no switch to yes with arrow keys and hit next, the next screen asks if Discharge sensor wired to S2 terminals, verify wired correctly and hit next. It will then ask if 10k sensor hit next again. 10.)Next screen says: A-Coil low temp cutoff:off switch to 35degree with arrow keys and hit next.

Programming Continued 11.)Next screen: Dry Contact Device On S terminals: no switch to yes and hit next. 12.)Go through installers set-up until you get to screen that says Water Leak Dry Contact alert: no switch to yes and hit next. 13.)Next screen: Water Leak alert eim Terminal S3 switch to S4 and hit next. Next : Water leak alert is normally open switch to normally closed hit next.

Programming Continued 14.)Next screen on install setup is: Sys Shutdown Dry Contact Alert:no switch to yes and hit next. Next says :Shutdown alert eim terminal S3 hit next. Finally asks shutdown alert is normally open switch to normally closed. 15.)Verify Dealer information is already installed, if not install information manually.

EIM Module Overview 1.)Wiring from thermostat to EIM Module is Red and common to thermostat terminals on EIM Module. 2.)Low voltage wiring to equipment is standard to equipment and standard connections on EIM Module terminals. 3.)Return air sensor to be connected EIM Module S1 terminals and is a 10k sensor.

EIM Module Overview Cont 4.)Discharge air sensor to be connected at S2 terminals on EIM Module, is 10k sensor, and set shut off at 35 degrees. 5.)Condensate safety switch to be wired to S3 terminals on EIM Module, needs to be set as shutdown device. 6.)Optional drain pan sensor to be wired to S4 terminals on EIM Module, needs to be set as leak detected.

EIM Module Overview Cont 7.)Verify dealer information is correctly installed in thermostat, if not input manually to thermostat. IMPORTANT: Must verify safety devices work and that the condensate safety switch shuts down Equipment.