Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Similar documents
Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

UP 258E11 OPTISENS OFFICE

Product and Applications Description

Product and functional description

Product and Applications Description

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Devices for Special Applications

Movement controller comfort, Flush-mounted (Up) xx, xx

Presence detector Komfort attachment Installation Instructions

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Connections, displays and operating elements E F. 20s 3min

DOCUMENTATION IPS640

DOCUMENTATION IPS640

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Use of the application program

System 2000 System 2000 automatic control switch Safety instructions. 2 Device components

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Description of the application programme for KNX occupancy detectors version 3.1

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Motion detector

1 Safety instructions. 2 Device components. Observer 220. Art.-No.: W 220 WW. Operationsmanual

Unpack, connect, done - no further work required

for relative humidity and temperature with calibration certificates

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

360º Surface Mount Ceiling PIR Light Controller

OPERATING INSTRUCTIONS

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

2. Safety. 4. Function

KNX/EIB - Product database - Application description

0701 CO Light, HVAC, Monitoring, Brightness

18/2 General. 18/4 Dimensional Drawings N. 18/7 Switches and Pushbuttons. 18/14 Socket Outlets. 18/16 Dimmers. 18/31 Motion Detectors

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Operating instructions

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

LPCMPIRM65 & LPCMPIRDSI65

Connections, displays and operating elements C D E G H. Installing the control unit

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Tebis application software

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

EBMHS (standard & slim-line PSU)

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

Installation Guide. Ceiling PIR Detector (311) Features and Connections

Sensors SR Programming manual

Synco-GAMMA Application Guide. Hotel buildings. Answers for infrastructure.

Detector switch - Dual Tech SCS

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

FR-A180 FR-A360. Occupancy detector. Use

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Tebis application software

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Synco-Gamma Application Guide. Retirement and nursing homes.

UV Flame Supervision System

Passive infrared ceiling sensor

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

, ,

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

1125 PIR Motion Detector

ARGUS movement detectors

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

LPC3BSP65 & LPC3BDP65

Automatic switch attachment Standard Installation Instructions

Viewguard Motion detctors PIR and DUAL detectors

Gira Sensotec / Gira Sensotec LED Motion detector, orientation light and contactless switch in one

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

Standard automatic switch 1.1 m, Standard automatic switch 2.2 m

System 3000 Motion detector top unit 1.10 m Standard, Motion detector top unit 2.20 m Standard

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

1. Basic safety information 3 2. Proper use 3

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

EBDSPIR-PRM-LV Product Guide

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Transcription:

Product DELTA i-system DELTA profil titanium white 5WG1 258-2HB11 pearl grey 5WG1 255-2AB01 carbon metallic 5WG1 258-2HB21 titanium white 5WG1 255-2AB11 aluminum metallic 5WG1 258-2H1 anthracite 5WG1 255-2AB21 silver 5WG1 255-2AB71 Frames titanium white 5WG1 258-2HB12 pearl grey 5WG1 255-2AB02 carbon metallic 5WG1 258-2HB22 titanium white 5WG1 255-2AB12 aluminum metallic 5WG1 258-2H2 anthracite 5WG1 255-2AB22 silver 5WG1 255-2AB72 ordered separately from the DELTA ranges --- cut out frames Bus coupling unit UP 110; UP 114 Product DELTA style DELTA ambiente titanium white 5WG1 257-2AB13 arctic white 5WG1 256-2AB01 basalt black 5WG1 257-2AB21 platinum metallic 5WG1 257-2A1 titanium white 5WG1 257-2AB14 arctic white 5WG1 256-2AB02 basalt black 5WG1 257-2AB22 platinum metallic 5WG1 257-2A2 Frames ordered separately from the DELTA ranges Intermediate frame 5TG1 368 basalt black Bus coupling unit UP 110; UP 114 2.13.1.2/1

B1 B2 B5 B1 Bus coupling unit UP B2 Frame *) Detachable masking plate *) B5 Intermediate frame (only for DELTA style basalt black) *) Lieferumfang Diagram 1: Installing the motion detector Product and Applications Description The motion detector UP 255 / UP 256 / UP 257 / UP 258 is a proximity sensor which reacts to movements of people, animals or other moving objects. If a motion is detected the corresponding telegrams are sent on the bus. It is used for example to detect people moving in its monitoring area. Using an appropriate application program, it gives switching commands via the flush-mounted bus coupling unit to actuators such as binary outputs to switch groups of luminaries or to signalling units. The motion detector can be operated in stand-alone mode, as a master or extension unit. Note: The device is not fitted to be used in connection with alarm systems. It is placed on the flush-mounted bus coupling unit, together with the relevant frame and is only operational when used together with the bus coupling unit and the corresponding application program i.e. the motion detector UP 255 / UP 256 / UP 257 / UP 258 (with flushmounted bus coupling unit] consists of the device (hardware) and the application program (software). The flush-mounted bus coupling unit and the relevant frame are not included with delivery and must be ordered separately. When using DELTA style a tier frame must be employed. Using the detachable masking plate supplied (), it is possible to reduce the detection range on the left or right. 1 2 Diagram 2: Reducing the detection range 1 Detection range 2 Screened range Detachable masking plate Using the ETS software, it is possible to select the application programs and assign the specific parameters and addresses. Technical Manual UP 25x, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2008 Electrical Installation Technology 2.13.1.2/2

Application Programs 12 S1 Mot.detect. standalone 211D01 Brightness level can be set Cyclical sending is possible Overshoot time, dead time and blocking function 12 S1 Mot.detect. central 211E01 Can be configured as a master unit in the case of multiple operation Brightness level can be set Cyclical sending is possible Dead time and blocking function can be assigned 12 S1 Mot.detect. branch 211F01 Can be configured as an extension input in the case of multiple operation Brightness level can be set Overshoot time, dead time and blocking function Installation Instructions The device can be used for permanent interior installations, in dry rooms and for insertion in flush-type boxes. V DANGER The device may only be installed and commissioned by an authorized electrician. The device may not be inserted in the same box as 230 V devices. The device may be used in switch sockets, if VDE approved devices have been used. The prevailing safety and accident regulations must be observed. The device may not be opened. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Technical data Power supply via the flush-mounted bus coupling unit Operating elements Potentiometer for step less adjustment of the range between 100% and 20% Properties Light sensor: adjustable in steps from approx. 1... 1000 lx (daylight mode to night mode) Horizontal detection angle: 180 degrees on two levels (can be reduced to 90 on the left or right using a detachable masking plate) Range for mounting height of 1.10 m: approx. 10 m Range for mounting height of 2.20 m: approx. 10 m Lateral range: 2 x approx. 6 m each side Optical system: Fresnel lens (2 levels with 18 segments) Connections 10-pole plug connector (PEI): for connection to the flush-mounted bus coupling unit Physical specifications Housing: plastic Dimensions (L x W x D): 68 x 68 x 23 mm / 65 x 65 x 23 mm / 55 x 55 x 23 mm Weight: approx. 45 g Fire load: approx. 750 kj ± 10 % Mounting: clipped onto the flush-mounted bus coupling unit Mounting height: 1.10 m / 2.20 m Electrical safety Degree of pollution (according to IEC 60664-1): 2 Type of protection (according to EN 60529): IP 20 Protection class (according to IEC 61140): III Overvoltage category (according to IEC 60664-1): III Bus: safety extra-low voltage SELV DC 24 V Device complies with EN 50 090-2-2 and EN 60669-2-1 EMC requirements complies with EN 50090-2-2 Environmental conditions Climatic withstand capability: EN 50090-2-2 Ambient temperature during operation: - 5... + 45 C Storage temperature: - 25... + 70 C Relative humidity (not condensing): 5 % to 93 % Markings KNX / EIB 2.13.1.2/3

CE mark in accordance with the EMC guideline (residential and functional buildings) and the low voltage guideline Location and function of the operating and display elements A3 A1 A3 A1 A2 Potentiometer for setting the range (left limit stop 20%, right limit stop 100%) A3 Mounting springs A4 10-pole plug connector (PEI) A4 A2 Diagram 3: rear view: Location of the display and operating elements Representation of the detection ranges Mounting height type Spatial view Top view Side view 1,10m 12 m 12 m 10 m 2,20m 12 m 12 m 4,5 mm 10 10 mm 12 m 4,3 m Type 2,20 Mounting height 1,10 2,5 2 mm 105 6 mm 12 m 6 m 6 m 2,2 m Diagram 4: Representation of the detection ranges Technical Manual UP 25x, 6 pages Siemens AG Update: http://www.siemens.de/gamma Siemens AG 2008 Electrical Installation Technology 2.13.1.2/4

March 2008 Mounting Note: The installation site and type of installation should be carefully selected according to the area that is to be monitored while considering any possible interference. The mounting wall should not be exposed to vibration or motion, as any movement of the motion detector has the same effect as thermal movement in the detection area. In order to prevent unwanted switching operations, the motion detector should if possible be installed so that it is not exposed to direct sunlight. Air turbulence caused by heaters, vents from air-conditioning units, dropping leaves of flowers etc. can also trigger switching operations in the monitoring area of the motion detector. Since infrared radiation is largely absorbed or reflected by glass, plastic, brickwork, metal and cardboard, it is not picked up by the motion detector. Depending on the lamp type, fluorescent lamps and incandescent lamps may not be placed less than 1-3 m away from the motion detector in the detection area. Otherwise, the motion detector may be switched on again due to the thermal variation in the sensor range generated when the lamp is switched off. The optimum range is achieved if the sensor is mounted sideways to the direction of movement. There could otherwise be a reduction in the range. Sources of interference (lamps, heating systems etc.) should be excluded from the detection area (e.g. using the detachable masking plate). Sensors should not be aligned towards the sun. The high level of thermal energy can destroy the sensors. In the event of voltage recovery and after each programming process, it is necessary to wait for an immunity period of approx. 80 seconds before the motion detector is ready for operation again. No telegrams are sent by the motion detector during this time. Mounting sequence - The flush-mounted bus coupling unit is connected and fixed in position in the flush-type box (see installation instructions for the flush-mounted bus coupling unit). - If required, the uninstalled detachable masking plate () is inserted on the left or right of the motion detector and induced to click into place by a strong pressure onto the 4 mounting clamps. - It must not be forgotten to adjust the potentiometer for setting the range (A2) of diagram 2. - Place the motion detector () with the relevant frame (B2) on the flush-mounted bus coupler (B1). - The brightness limit is set in the application program. - It is possible to check the function of the detector or the detection area after programming by carrying out a walk test (according to detection area in Diagram 4). Before this the setting maximum has to be selected for the brightness and the setting minimum has to be selected for the switching interval in the parameter list. B1 B2 B5 General description The motion detector is placed on the flush-mounted bus coupling unit together with the relevant frame (DELTA profil cut-out, DELTA ambiente or DELTA style with the relevant tier frame). B1 B2 B5 Diagram 4: Installing the motion detector Flush-mounted bus coupling unit Frame Detachable masking plate Intermediate frame (only for DELTA style basalt black) 2.13.1.2/5

Dismantling The motion detector () together with the frame is manually removed from the flush-mounted bus coupling unit (B1). If a modification of the viewing area is required, the detachable masking plate can be removed careful. DELTA profil DELTA ambiente DELTA style (basalt black) Dimensions in mm 65 Dimensions Diagram 65 DELTA i-system Dimensions in mm 55 23 55 DELTA style (titanium white, platinum metallic) Dimensions in mm 68 30 68 30 General Notes The operating instructions must be handed over to the client. Any faulty device should be returned to the local Siemens office. If you have further questions concerning the product please contact our technical support:! +49 (180) 5050-222! +49 (180) 5050-223 " www.siemens.com/automation/support-request 2.13.1.2/6