Full Extension Soft-Close Undermount Drawer Slide

Similar documents
569F/569A Installation Instructions

569F/569A installation instructions

Installation & Operation Manual

INSTRUCTION MANUAL HS-229G


- User Brochure tekmarnet 4 Setpoint Control 161

60In. Ceiling Fan. Owner s Manual

TrueClean ToteCleaner

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

CD6102 / CD6102 OC / CD6102-2

Sound Cover [ , , , ]

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

Patent Pending invent for New Construction

INSTALLATION AND OPERATING MANUAL

PIR Sensor. User s Guide

ion Genesis Pump Controller

MaxLite LED Vapor Tight Linear Fixture

COMBUSTION AIR SYSTEM

Installation Instructions PP-AS20 Anti-Scale System

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

TrueClean ToteCleaner

GRAND EFFECTS Fire-Water Bowls Model 100

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

THE BOARD 100IB / 200IB HOME IRONING BOARD INSTRUCTION MANUAL

Flat Line Spray Systems Kits

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Camarillo 52 Ceiling Fan

- User Brochure Programmable Thermostat 510

Torrena 42 Ceiling Fan

WATCHMAN AREA VOLTAGE DETECTOR

EQUIPMENT Operation Manual

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

USER S OPERATING AND INSTRUCTION MANUAL

USER MANUAL Table of Contents

Service Parts, Kits and Accessories

A2Z Ozone, Inc. PRODUCT MANUAL

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Next Generation Corona Discharge Auto Voltage Sensing Installation Manual

Duct Mount. Installation Instructions

Desiccant Air Drying System

BIG BOOT COMBUSTION AIR KIT Model: CAS-2BB, CAS-2CB, CAS-2B375

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Active Thermal Management. SEC-1 Installation Instructions

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

AIR OZONE GENERATOR MANUAL MODEL AIR /240V 50/60HZ

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

MaxLite LED MICRO-T PANEL

TANDEM TANDEM. Premium concealed runners for wood drawers.

TECHNICAL INSTRUCTIONS

120 VAC SYSTEM CONTROL KIT

Installation Instructions / Warranty

Installation and Maintenance Instructions

Waving Lighted Snowman Yard Art

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

SYSTEM CONTROL KIT Model: CK-41P

Fire-Water Bowls Model 100

AUTOMATIC SWINGING DOOR

THE CAPRI III CEILING FAN INSTALLATION INSTRUCTIONS

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

View the expanded manual: GEN5

Light Construction Equipment Consumer Warranty Policy

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

PROFESSIONAL CURLING IRON with adjustable temperature settings and Auto Shut Off after 60 minutes

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual & Operating Instructions

GETZ MANUFACTURING PART # CYLINDER DRYER

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

Clean Steam Generators

Door/Window Sensor Installation Instructions

Heater Installation Kit

HEAT PRESS USER S GUIDE

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Retrofit Instructions for Tower Dryer Moisture Sampler Blower Kit

Corrosion Resistant Fluid and Air Handling Systems.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

THE GEORGIA PATIO CEILING FAN INSTALLATION INSTRUCTIONS

Home Theater Interface Plate INSTALLATION INSTRUCTION

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

IRON/TONES TM REQUIRED 2T1A TOOLS AND 1 MATERIALS T01-A INSTALLATION INSTRUCTIONS / SELF-RIMMING OR UNDERCOUNTER KITCHEN SINK K-6625

F114 and F115 Ceiling Surface Mounted Media Air Cleaners

Electric Duct Heaters

V-WATCH PERSONAL VOLTAGE DETECTOR

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

Operation & Installation Guide

Transcription:

Full Extension Soft-Close Undermount Drawer Number: Mounting: Height: 1-7/8" Load Rating: Finish: Travel: SPECIFICATIONS Full Extension Soft-Close Undermount Drawer Side, for Frame or Frameless Construction 120-Pound Class Zinc Full Extension Sizes: 18", 20", 21", 22", 24", 27", 30" Packaged: Release Lever: Fasteners: Install Jig: Bulk (B): 4 Pairs per Carton MUV1D-RL: Up/Down Height Adjustment. 60 pairs per carton MUV2D-RL: Up/Down Height, Side-to-Side Adjustment. 24 pairs per carton MUV3D-RL: Up/Down Height, Side-to-Side, In/Out Adjustment. 12 pairs per carton MUVRL INSET: Inset Adjuster (MUV2D-RL Add On). 12 pairs per carton MUV-122: #7 x 5/8" Flat Head Screw MUV-123: #6 x 1/2" Truss Head Screw Front Release Levers and Rear Bracket MUV-124 Material For use with the following material thicknesses: 5/8" [16mm] 9/16" [14mm] 1/2" [13mm] DRAWER ASSEMBLY Maximum Operating Conditions Maximum Drawer Width: 42" Maximum Load Rating: 120 lb. Maximum Drawer Material : 5/8" Note: Frame Applications must be blocked out. DRAWER HARDWARE INSTALLATION 15/16" [24mm] 1-1/4" [32mm] Release Lever Adjustment (1/8") (Vertical Adjustment) 1/4" [6.3mm] Variable Drawer Bottom Drawer Bottom Pre-drill front holes at 15º angle. 1

Full Extension Soft-Close Undermount Drawer RELEASE LEVERS HEIGHT ADJUSTMENT HEIGHT & SIDE-TO-SIDE ADJUSTMENT MUV-1D MUV-2D Height Height Side-to-side HEIGHT & SIDE-TO-SIDE & IN/OUT ADJUSTMENT MUV-3D IN/OUT ADJUSTMENT MVRL Inset (add onto MUV-2D) Height In/Out Side-to-side Part Number Height Side-to-Side In/Out BOTTOM HOLE PATTERN MUV1D-RL + 1/8" [3mm] MUV2D-RL + 1/8" [3mm] ± 1/16" [1.5mm] MUV3D-RL + 1/8" [3mm] ± 1/16" [1.5mm] + 3/32" [2.5mm] B 3/4" [19mm] A 15/32" [12mm] C 2-33/64" [64mm] Cabinet Depth Min. Drawer A B C MUVHDAB 30 30" [762mm] 30-3/4" [781mm] 30-7/16" [773mm] 30" [762mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] MUVHDAB 27 27" [610mm] 27-3/4" [705mm] 27-7/16" [697mm] 27" [610mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] MUVHDAB 24 24" [610mm] 24-3/4" [629mm] 24-7/16" [621mm] 24" [610mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] MUVHDAB 22 22" [533mm] 22-3/4" [578mm] 22-7/16" [570mm] 22" [533mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] MUVHDAB 21 21 [533mm] 21-3/4" [553mm] 2 [545mm] 21" [533mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] MUVHDAB 20 20" [457mm] 20-3/4" [527mm] 20-7/16" [520mm] 20" [457mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] MUVHDAB 18 18" [457mm] 18-3/4" [479mm] 18-7/16" [469mm] 18" [457mm] 15/32" [12mm] 3/4" [19mm] 12-1/2" [317mm] 2

Full Extension Soft-Close Undermount Drawer FRAMELESS APPLICATIONS [WITH DECORATIVE FRONT] Cabinet Depth [see chart at bottom of page] A B C [see chart at bottom of page] [see chart at bottom of page] Setback 1/8" [3mm] Mount Position Drawer Min. Top Gap 1/4" [6mm] Max. Drawer Height= Opening minus 13/16" [20mm] Bottom Recess 1/2" [12.7mm] Bottom Clearance 9/16" [14mm] Drawer Gap 1/32" [1mm] REAR SLIDE DETAIL SLIDE FRONT DETAIL 1-1/4" [32mm] 1- [34mm] TYP TYP. 9/32" [7mm] TYP. TYP. 1-15/32" [37.5mm] Cabinet Depth Min. Drawer A B C Max. Material MUVHDAB 30 30" [762mm] 30-3/4" [781mm] 30-7/16" [773mm] 30" [762mm] 5-3/64" [128mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 27 27" [610mm] 27-3/4" [705mm] 27-7/16" [697mm] 27" [610mm] 5-3/64" [128mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 24 24" [610mm] 24-3/4" [629mm] 24-7/16" [621mm] 24" [610mm] 5-3/64" [128mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 22 22" [533mm] 22-3/4" [578mm] 22-7/16" [570mm] 22" [533mm] 10-5/64" [256mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 21 21 [533mm] 21-3/4" [553mm] 2 [545mm] 21 [533mm] 10-5/64" [256mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 20 20" [457mm] 20-3/4" [527mm] 20-7/16" [520mm] 20" [457mm] 7-9/16" [192mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 18 18" [457mm] 18-3/4" [479mm] 18-7/16" [469mm] 18" [457mm] 7-9/16" [192mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] Setback 3

Full Extension Soft-Close Undermount Drawer FACE-FRAME APPLICATIONS [WITH DECORATIVE FRONT] Cabinet Depth [see chart at bottom of page] C A [see chart at bottom of page] B [see chart at bottom of page] Setback 1/8" [3mm] Mount Position 3/8" [10mm] Drawer Min. Top Gap 1/4" [6mm] Bottom Recess 1/2" max. [12.7mm] Max. Drawer Height= Opening minus 13/16" [20mm] Bottom Clearance 9/16" [14mm] NOTE: FRAME APPLICATIONS MUST BE BLOCKED OUT Drawer Gap 1/32" [1mm] REAR SLIDE DETAIL SLIDE FRONT DETAIL 1-1/4" [32mm] 1- [34mm] TYP TYP. 9/32" [7mm] TYP. TYP. 1-15/32" [37.5mm] Cabinet Depth Min. Drawer A B C Max. Material MUVHDAB 30 30" [762mm] 30-3/4" [781mm] 30-7/16" [773mm] 30" [762mm]** 5-3/64" [128mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 27 27" [610mm] 27-3/4" [705mm] 27-7/16" [697mm] 27" [610mm]** 5-3/64" [128mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 24 24" [610mm] 24-3/4" [629mm] 24-7/16" [621mm] 24" [610mm]** 5-3/64" [128mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 22 22" [533mm] 22-3/4" [578mm] 22-7/16" [570mm] 22" [533mm]** 10-5/64" [256mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 21 21 [533mm] 21-3/4" [553mm] 2 [545mm] 21 [533mm]** 10-5/64" [256mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 20 20" [457mm] 20-3/4" [527mm] 20-7/16" [520mm] 20" [457mm]** 7-9/16" [192mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] MUVHDAB 18 18" [457mm] 18-3/4" [479mm] 18-7/16" [469mm] 18" [457mm]** 7-9/16" [192mm] 8-13/16" [224mm] 1-1/16" [27mm] 5/8" [16mm] 1/8" [3mm] Setback 4

Full Extension Soft-Close Undermount Drawer INSET APPLICATION FACE-FRAME Min. Min. = + Setback + 1/4" [6mm] NOTE: FRAME APPLICATIONS MUST BE BLOCKED OUT FRAMELESS Variable Setback Min. Min. = + Setback + 1/4" [6mm] RUNNER SETBACK INSET APPLICATIONS Drawer Sub-Front 1D & 2D Release Lever KV Part #: MUV1D-RL & MUV2D-RL Charted setbacks set the face of the drawer front flush with face of cabinet Setback 1/2" [13mm] 11/16" [17.5mm] 13/16" [21mm] 15/16" [24mm] 5/8" [16mm] 13/16" [21mm] 15/16" [24mm] 1-1/16" [27mm] 3/4" [19mm] 15/16" [24mm] 1-1/16" [27mm] 1-3/16" [30mm] 5/8" [16mm] 3/4" [19mm] 7/8" [22mm] Drawer Front Calculation: Drawer Sub-Front + Drawer Front - 7/16" [11mm] Drawer Sub-Front 3D Release Lever KV Part #: MUV3D-RL Charted setbacks set the face of the drawer front flush with face of cabinet Setback 1/2" [13mm] 23/32" [18.5mm] 27/32" [22mm] 5/8" [16mm] 27/32" [22mm] 1-3/32" [28mm] 3/4" [19mm] 1-3/32" [28mm] 1-7/32" [31mm] 5/8" [16mm] 3/4" [19mm] 7/8" [22mm] Drawer Front Calculation: Drawer Sub-Front + Drawer Front - 13/32" [10mm] 5

Full Extension Soft-Close Undermount Drawer DRAWER DIMENSIONS FOR FACE-FRAME AND FRAMELESS APPLICATIONS Cabinet Opening Width Min. Top Opening Clearance: 6.3mm (1/4") Drawer Width Calculation Drawer Deduct from Opening Width 5/8" [16mm] 3/8" [10mm] 9/16" [14mm] 9/16" [14mm] 1/2" [13mm] 5/8" [16mm] If material is less than 1/2", use formula.* CRITICAL* Inside Drawer Width CRITICAL Max. Drawer Bottom Recess: 12.7mm (1/2") Min. Bottom Opening Clearance: 14mm (9/16") *Cabinet Opening Width Minus 42mm (1-5/8") = Inside Drawer Width MuV+ HD Maximum Drawer Side Material : 16mm (5/8") Use Muv+34 HD for Drawer Material from 16mm (5/8") to 19mm (3/4") DRAWER NOTCH & BORE 9/32" [7mm] 7/16" [11mm] 1/4" x 3/8" DEEP [6mm x 10mm DEEP] 1/2" Max. [12.7mm] 1-3/8" Min. [35mm] KNAPE & VOGT LIMITED LIFETIME WARRANTY FOR COMMERCIAL PRODUCTS This warranty is given to the initial purchaser of new commercial products purchased from Knape & Vogt and its subsidiaries. The warranty covers defects in materials and workmanship. The warranty does not apply to defects resulting from misuse, damage or abuse, normal wear and tear, accident, modification, improper installation or maintenance, third party materials or damage during shipping. The warranty is not transferable and does not cover any subsequent purchasers of the products. During the Limited Lifetime Warranty period, Knape & Vogt, will, at its option, repair or replace any defective product with a comparable product or component. This Limited Warranty is for repair or replacement of defective products only and does not cover any other costs such as removal, installation, or other related expenses. For warranty service, please contact Knape & Vogt, 2700 Oak Industrial Drive, Grand Rapids, MI 49505, Attention: Customer Service. Information regarding the claimed defect and date of purchase of the product must be provided. Any defective product must be returned postage or freight prepaid to Knape & Vogt. THIS LIMITED WARRANTY CONSTITUTES THE ONLY WARRANTY FOR THE PRODUCTS AND ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXPRESSLY DISCLAIMED. THIS LIMITED WARRANTY CONSTITUTES THE SOLE REMEDY AVAILABLE WITH REGARD TO ANY DEFECTIVE PRODUCTS. KNAPE & VOGT SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSS OF TIME, INCONVENIENCE, OR LOST REVENUES OR PROFITS. 2700 Oak Industrial Drive NE Grand Rapids, MI 49505 800.253.1561 616.459.3311 fax 616.459.3290 www.kv.com Copyright 2017 Knape & Vogt, all rights reserved. Standard KV Commercial Warranty Manufacturer reserves the right to change specifications without notice and without incurring responsibility for existing units. US Patent 8,430,567 6 310482/0117