QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

Similar documents
QDV5V - 1 Door Standard (Gemtron)

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

INSTALLATION & OPERATION MANUAL

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

IMPORTANT KEEP IN STORE FOR FUTURE USE

QM5, QM5G Multi-Deck Meat Display Case. Part Number: 31E03028 Date: 08/13/2007

Installation & Operation Manual

Product Specifications Sheets

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

LOW PROFILE UNIT COOLER

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Center Mount Unit Coolers

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

TECHNICAL SPECIFICATIONS

RMN with INNOVATOR Doors Technical Data Sheet

Installation, Operation, and Maintenance Information

Installation and Operation Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

TECHNICAL SPECIFICATIONS

Introductions General Information. Receiving/Shipping Damage/Lost Items

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

Introductions General Information. Receiving/Shipping Damage/Lost Items

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. Reach-In Display Case. KW-IOM-2149 July 2016 Part No. 31E02149

Installation & Service Manual

TECHNICAL SPECIFICATIONS B6VMMX

RVZC30 (and BB/T/TBB/WA), RVZP30 (and BB/T/TBB/WA), RVC24

Reach In Refrigerators Bottom Mount

Installation & Operation Manual

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

Installation & Service Manual

Installation & Service Manual

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

AP- Series AeroPak Thru-The-Wall (Modular) Package Units Electric Cooling / Electric Heat Electric Cooling / Gas Heat Heat Pump / Electric Heat

Glass Doors, Hinged Bottom Mounts

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...

slm series Refrigerant: R404a Refrigeration Range: -0 /-13 F Climate Range: +77 F/+95 F Forced Air Ventilation Automatic Hot Gas Defrosting

PPL Electric Utilities Energy Efficiency and Conservation Program

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Low Flow Unit Coolers

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

Specifications and Performance

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

INSTALLATION & OPERATION MANUAL

Jr. Tech (JT-1, 2, 3) Knowledge Areas

HIGH EFFICIENCY AIR HANDLER

Installation & Operation Manual. Reach-In Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

RLT with INNOVATOR Doors

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

TECHNICAL SPECIFICATIONS

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Cabinet & Merchandiser Price List

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Direct Install Program Eligible Measures Listing:

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

TECHNICAL SPECIFICATIONS

KRYO FORTRESS MOTOR/FAN PACKS A HIGH-EFFICIENCY ECM MOTOR WITH A DUST-TIGHT, WATER-TIGHT IP66 RATING

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Versatile new products for multiple applications and specialty conditions. New Products Catalog

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Transcription:

CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat 2.43 3.43 4.35 5.40 PSC Fan 0.52 0.78 1.04 1.30 STD Fan 1.04 1.56 2.08 2.60 ECM Fan 0.50 0.75 1.00 1.25 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED Light (Gelcore) 0.48 0.73 0.98 1.20 Drain Pan Heater 0.39 0.65 0.91 1.17 Defrost Heater (Electric 230V) All electrical data based on 115V. Add 0.97 amps per heated glass end panel. QLV5V-A - Glass Door Eliminator - QIV5V-A - Glass Door Eliminator - Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Doors Facing Area Cubic Volume 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² 121.4 ft³ 5 60 ft² 151.8 ft³ Air Velocity Air -17 F 300 FPM -11 F -10 F 300 FPM -5 F units. ADD 8% to BTU LOAD. The above case model has case lengths that are UL and NSF approved. (-17 F) STD Fan 1286 PSC Fan 1238 ECM Fan 1180 (-10 F) STD Fan 1200 PSC Fan 1153 ECM Fan 1095

CASE DATA - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat Amps 3.63 5.25 7.02 8.61 PSC Fan Amps 0.52 0.78 1.04 1.30 STD Fan Amps 1.04 1.56 2.08 2.60 ECM Fan Amps 0.50 0.75 1.00 1.25 LED Light Amps (Gelcore) 0.48 0.73 0.98 1.20 T8 Lights 1.39 1.80 2.32 2.79 Drain Heater Amps 0.39 0.65 0.91 1.17 Defrost Load Amps (optional 230V) All electrical data based on 115V. Add 0.97A for each end panel with heated glass. Electric 1 45 min 65 F Hot Gas 1 25 min 47 F Assorted Shelving Options Available QLV5VT-A - Tall Glass Door - Standard ( ) QIV5VT-A - Tall Glass Door - Standard ( ) Application: Specification Sheet that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual -Jet and Air Defrost are registered trademarks of. STD Fan 1492 1417 PSC Fan 1445 1370 ECM Fan 1386 1311 units, add 8% to BTU load. *For lighted shelves, please add 19 BTUH.* Add 30 BTUH/Door for STD motors. The above case model has case lengths that are UL and NSF approved. Door 2 3 4 5 Facing Area (ft²) 25.1 37.3 49.8 62.2 Cubic Capacity (ft³) 60.7 91.0 121.4 151.8 Air Velocity Air -18 F 300 FPM -12 F -11 F 300 FPM -5 F Issue: 3.4.2010

CASE DATA - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat Amps 2.43 3.32 4.40 5.44 PSC Fan Amps 0.52 0.78 1.04 1.30 STD Fan Amps 1.04 1.56 2.08 2.60 ECM Fan Amps 0.50 0.75 1.00 1.25 LED Light Amps (Gelcore) 0.48 0.73 0.98 1.20 T8 Lights 1.39 1.80 2.32 2.79 Drain Heater Amps 0.39 0.65 0.91 1.17 Defrost Load Amps (optional 230V) All electrical data based on 115V. Add 0.97A for each end panel with heated glass. Electric 1 45 min 65 F Hot Gas 1 25 min 47 F Assorted Shelving Options Available QLV5VT-A - Tall Glass Door - Eliminator ( ) QIV5VT-A - Tall Glass Door - Eliminator ( ) Application: Specification Sheet that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual -Jet and Air Defrost are registered trademarks of. STD Fan 1345 1270 PSC Fan 1298 1223 ECM Fan 1239 1164 units, add 8% to BTU load. *For lighted shelves, please add 19 BTUH.* Add 30 BTUH/ Door for STD motors. The above case model has case lengths that are UL and NSF approved. Door 2 3 4 5 Facing Area (ft²) 25.1 37.3 49.8 62.2 Cubic Capacity (ft³) 60.7 91.0 121.4 151.8 Air Velocity Air -17 F 300 FPM -12 F -10 F 300 FPM -5 F Issue: 3.4.2010

CASE DATA AMPS 1 Door Anti-Sweat 1.90 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 1.00 LED Lights 0.24 Drain Heater 0.25 Electric Defrost (Electric - 230V) 3.36 All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION 22 7 42 29 17/32 4 1/2? REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) QLV5V - 1 Door Standard - (Anthony) QIV5V - 1 Door Standard - (Anthony) that conditions do not exceed 75 F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Air Velocity Air -18 F 225 FPM -12 F -11 F 200 FPM -5 F unit, add 8% to BTUH load. Case BTUH - 1 Door (-18 F) PSC Fan 1424 ECM Fan 1346 (-11 F) PSC Fan 1348 ECM Fan 1270

CASE DATA AMPS 1 Door Anti-Sweat 1.79 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 0.98 LED Lights 0.26 Drain Heater 0.25 Electric Defrost (Electric - 230V) 3.36 All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION 22 7 42? 29 17/32 4 1/2 REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) QLV5V - 1 Door - (Gemtron) QIV5V - 1 Door - (Gemtron) that conditions do not exceed 75 F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Air Velocity Air -18 F 225 FPM -12 F -11 F 200 FPM -5 F unit, add 8% to BTUH load. Case BTUH - 1 Door (-18 F) PSC Fan 1424 ECM Fan 1346 (-11 F) PSC Fan 1348 ECM Fan 1270

CASE DATA AMPS 1 Door Anti-Sweat 1.35 PSC Fan / # Fans 0.37/1 ECM Fan / # Fans 0.30/1 T8 Lights 1.00 LED Lights 0.24 Drain Heater 0.25 Electric Defrost (Electric - 230V) 3.36 All electrical data based on 115V and unlighted shelves. Add 0.97 amps per heated glass end panel. 44 40 1/2 8 1/8 18 3/4 1 5/8 (END) ELECTRICAL 2 4 3/4 Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at anytime, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. 34 1/8 WITH ENDS 30 7/8 16 1/8 C L KICKPLATE LOCATION 22 7 42 29 17/32 4 1/2? REFRIGERATION DRAIN CONNECTION (W/ TRAP RIGHT OR LEFT) QLV5V - 1 Door Eliminator - (Anthony) QIV5V - 1 Door Eliminator - (Anthony) Facing Area 12.8 ft 2 Cubic Capacity 29.9 ft 3 Air Velocity Air -18 F 225 FPM -12 F -10 F 200 FPM -5 F unit, add 8% to BTUH load. Case BTUH - 1 Door (-18 F) PSC Fan 1284 ECM Fan 1206 (-11 F) PSC Fan 1208 ECM Fan 1130

CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat 3.83 5.62 7.42 9.15 PSC Fan 0.52 0.78 1.04 1.30 STD Fan 1.04 1.56 2.08 2.60 ECM Fan 0.50 0.75 1.00 1.25 Light (T8 ELS) 1.39 1.80 2.32 2.79 LED Light (Gelcore) 0.48 0.73 0.98 1.20 Drain Pan Heater 0.39 0.65 0.91 1.17 Defrost Heater (Electric 230V) All electrical data based on 115V. Add 0.97 amps per heated glass end panel. QLV5V-A - Glass Door Standard - (Anthony) QIV5V-A - Glass Door Standard - (Anthony) Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained such that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual-Jet and Air Defrost are registered trademarks of. Doors Facing Area Cubic Volume 2 24 ft² 60.7 ft³ 3 36 ft² 91.0 ft³ 4 48 ft² 121.4 ft³ 5 60 ft² 151.8 ft³ Air Velocity Air -18 F 300 FPM -12 F -11 F 300 FPM -5 F units. ADD 8% to BTU LOAD. (-18 F) STD Fan 1426 PSC Fan 1378 ECM Fan 1320 (-11 F) STD Fan 1325 PSC Fan 1278 ECM Fan 1220 The above case model has case lengths that are UL and NSF approved.

CASE DATA AMPS - # of Doors 2 DR 3 DR 4 DR 5 DR Anti-Sweat 3.04 4.42 6.14 7.33 PSC Fan 0.52 0.78 1.04 1.30 STD Fan 1.04 1.56 2.08 2.60 ECM Fan 0.50 0.75 1.00 1.25 Light (T8 ELS) 1.55 1.97 2.53 2.95 LED Light (Gelcore) 0.52 0.78 1.04 1.30 Drain Pan Heater 0.39 0.65 0.91 1.17 Defrost Heater (Electric 230V) All electrical data based on 115V. Add 0.97 amps per heated glass end panel. QLV5V-A - Glass Door Gemtron - QIV5V-A - Glass Door Gemtron - Application: Specification Sheet that conditions do not exceed 75 deg F and 55% relative humidity., whose policy is one of continuous improvement, reserves the right to change at any time, specifications, design or prices without incurring obligation. Dual -Jet and Air Defrost are registered trademarks of. Doors Facing Area Cubic Volume 2 24 ft² 60.7 ft 3 3 36 ft² 91.0 ft 3 4 48 ft² 121.4 ft 3 5 60 ft² 151.8 ft 3 Air Velocity Air -18 F 300 FPM -12 F -11 F 300 FPM -5 F units. ADD 8% to BTU LOAD. The above case model has case lengths that are UL and NSF approved. (-18 F) STD Fan 1426 PSC Fan 1378 ECM Fan 1320 (-11 F) STD Fan 1325 PSC Fan 1278 ECM Fan 1220