For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Similar documents
For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Installation Guide for models:

Access Power Controllers with Power Supplies

Installation Guide for models:

Series. Access Power Controllers. Installation Guide

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

Rack Mount Series Installation Guide

AL600ULX Series. Power Supply/Charger. Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AL800ULADA. NAC Power Extender. Installation Guide

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

more than just power! Altronix is the professional security industry s leading manufacturer

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Booster Power Supply Manual

RELEASE DEVICE CONTROLS

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

MODEL B2 INSTALLATION MANUAL

Power Supplies. Overview

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Remote NAC Power Supply D7038

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

MR-2602 Two Zone Fire Alarm Control Panel

4100U City and Relay Cards Installation Instructions

PSN-1000 & PSN 1000(E) Installation Manual

Model 17A00 Expansion Enclosure

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

KT-100 Door Controller

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

EVO192 v3.0 Fire and Burglary What s New

TECHNICAL DATA OBSOLETE

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

AL602ULADA AL802ULADA AL1002ULADA

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Addressable NAC Output Module D327A

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Commercial and Light Industrial Fire Alarm Control Panel

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Notification Appliance Circuit Module

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

July 14, 1999 DF C-100.

Specification/ Data Sheet

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

MANUAL RESET ALARM RELEASE

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

FEC400 Series. Installation Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

1. POWERPATH Operation

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Conventional Releasing Control Panel

LifeAlarm Fire Alarm Controls

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

June 10, 2002 DF C S2424

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

30.45 Electric Release PDRP-2001

SIGA-CC1 Single Input Signal Module Installation Sheet

Transcription:

Power Supply/Chargers Installation Guide Models Include: eflow4na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow6na8-4a @ 12VDC or 24VDC - Eight (8) Fused Outputs eflow102na8-10a @ 12VDC - Eight (8) Fused Outputs eflow104na8-10a @ 24VDC - Eight (8) Fused Outputs ULC-S319 - Electronic Access Control Systems will be invalidated through the use of any add-on, expansion, memory or other module manufactured by the manufacturer or other manufacturers. For a red enclosure add an R suffix to the part # e.g. eflow4na8r Altronix Corp. 140 58th St. Brooklyn, NY Rev. eacm052313 More than just power. TM Installing Company: Service Rep. Name: Address: Phone #:

Altronix Corp. 140 58th St. Brooklyn, NY Overview: These units distribute and switch power to access control systems and accessories. They convert a 120VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC fuse protected outputs. These power outputs can be converted to dry form C contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. Altronix Model Number eflow4na8 eflow6na8 eflow102na8 eflowna8 Series Configuration Reference Chart: 12VDC Output Range (V) Nominal DC Output Voltage Options [DC] [AUX] 10.1-13.2 10.0-13.2 10.03-13.2 eflow104na8 24VDC Output Range (V) 20.28-26.4 20.19-26.4 20.17-26.4 12VDC Output Range (V) 10.05-13.2 10.03-13.2 10.03-13.2 24VDC Output Range (V) 20.2-26.4 20.19-26.4 Maximum Supply Current for Main and Aux. Outputs (A) 12VDC 24VDC Fuse Protected Outputs 120VAC 60 Hz Input (current) Current per ACM8 output (A) 3.3A 3.6A 8 3.5A 2.5A 5.3A 5.6A 8 3.5A 2.5A 9.3A 8 3.5A 2.5A 20.17-26.4 Power Supply Board Input Fuse Rating 5A/ 5A/ 5A/ 9.6A 8 4.5A 2.5A 6.3A/ Power Supply Board Battery Fuse Rating 7.5A/ 32V 10A/ 32V 15A/ 32V 15A/ 32V ACM8 Board Input Fuse Rating 10A/ 10A/ 10A/ 10A/ ACM8 Board Output Fuse Rating 3.5A/ 3.5A/ 3.5A/ 3.5A/ *eflow4na8 only: This unit is classified as Power-Limited stand alone power supply with stand-by battery and it is suitable to power: sensors, electro-mechanical devices (e.g. electric door strikes). *eflow6na8, eflow102na8, and eflow104na8: The DC output for these power supplies are not power-limited. If a power-limited output is required in the end-product application, the DC output from the power supply must be connected to a separately Listed control unit or accessory board that provides power-limited outputs. The product(s) providing the power-limited output(s) must be listed as appropriate for the particular end-product application (access control), and wired in accordance with the products installation instructions. Class 1 wiring methods, separation of circuits, and proper fire-rated enclosures all must be considered when connecting the DC output of the power supply to the end-product devices. The auxiliary outputs of these units are power-limited. UL Listings for US Installations: UL 294 - UL Listed for Access Control System Units. UL Listings for Canadian Installations: ULC-S319-05 - Electronic Access Control Systems. Class I Equipment. CSA C22.2 No.205 - Signal Equipment. California State Fire Marshal European Conformity - 2 - eflowna8 Series

Specifications: ACM8 Access Power Controller Module: Eight (8) independently trigger controlled outputs. Output options: a) Eight (8) Fail-Safe filtered power outputs. b) Eight (8) Fail-Secure filtered power outputs. c) Eight (8) form C relay outputs (rated @ 5A/24VDC or VAC). d) Any combination of the above. Eight (8) Access Control System trigger inputs. Input trigger options: a) Eight (8) normally open (NO) dry trigger inputs. b) Eight (8) open collector inputs. c) Any combination of the above. Eight (8) unswitched filtered aux. power outputs (outputs are rated @ 2.5A). Red LEDs on ACM8 board indicate individual outputs are triggered (relays energized). Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input trigger options: a) Normally open (NO) or normally closed (NC) dry trigger input. b) Polarity reversal input from FACP signaling circuit. Green LED on ACM8 board indicates FACP disconnect is triggered. FACP output relay indicates that FACP input is triggered (form C contact rated @ 1A/28VDC not evaluated by UL). eflow Power Supply/Charger provides common power for ACM8 board and all connected access control devices. ACM8 board main fuses are rated @ 10A. Output fuses are rated @ 3.5A. eflow Power Supply/Charger: Input: 120VAC, 60Hz. For output voltage and supply current refer to eflowna8 Series Configuration Chart, pg. 2. Auxiliary Power-Limited output rated @ 1A (unswitched). Overvoltage protection. Built-in charger for sealed lead acid or gel type batteries. Maximum charge current 1.54A. Automatic switch over to stand-by battery when AC fails. Transfer to stand-by battery power is instantaneous with no interruption. Supervised Fire Alarm disconnect (latching or non-latching) 10K EOL resistor. Operates on a normally open (NO) or normally closed (NC) trigger. AC fail supervision (form C contacts). Battery fail and presence supervision (form C contacts). Low power shutdown. Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge. For fuse rating, refer to eflowna8 Series Configuration Chart, pg. 2. Green AC Power LED indicates 120VAC present. AC input and DC output LED indicators. Short circuit and overload protection. Enclosure accommodates up to two (2) 12AH batteries. Enclosure dimensions: 15.5 x 12 x 4.5 (393.7mm x 304.8mm x 114.3mm). Power Supply Board Stand-by Battery Specifications: Battery eflow4na8 eflow6na8 eflow102na8 eflow104na8 7AH 30 Mins./4A* 10 Mins./6A 5 Mins./10A 5 Mins./10A 12AH 35 Mins./4A* 30 Mins./6A* 30 Mins./10A* 30 Mins./10A* 40AH Over 4 Hours/4A* Over 4 Hours/6A* Over 2 Hours/10A* Over 2 Hours/10A* 65AH Over 4 Hours/4A* Over 4 Hours/6A* Over 4 Hours/10A* Over 4 Hours/10A* *Only these configurations can be utilized in ULC-S319 installations. eflowna8 Series - 3 -

Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, The Canadian Electrical Code, Part I, Part II, and with all local codes and authorities having jurisdiction. The product must be located indoors within the protected premises. Power Supply Board LED Diagnostics (pg. 6) Access Power Controller LED Diagnostics (pg. 6) Power Supply Board Terminal Identification (pg. 6) Access Power Controller Terminal Identification (pg. 6) Power Supply Board Stand-by Battery Specifications (pg. 3) Power Supply Board Output Voltage Settings (pg. 7) Access Power Controller Typical Application Diagram (pg. 7) FACP/Optional Power Supply Hook-up Diagrams (pg. 10) 1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 11). Secure enclosure to earth ground. 2. Connect unswitched AC power (120VAC 60Hz) to terminals marked [L, N] (Fig. 3, pg. 8). Do not use terminal marked [G]. Use 14 AWG or larger for all power connections. Secure green wire lead attached to the chassis to earth ground. Keep power-limited wiring separate from non power-limited wiring. Minimum 0.25 spacing must be provided (Fig. 3, pg. 8). CAUTI: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel. 3. Select desired DC output voltage by setting SW1 to the appropriate position on the power supply board (eflow4na8 and eflow6na8) (Fig. 1, pg. 7). eflow102na8 power supply is factory set at 12VDC. eflow104na8 power supply is factory set at 24VDC. 4. Measure the output voltage of the unit before connecting any devices to ensure proper operation. Improper or high voltage will damage these devices. 5. Output options (Fig. 2, pg. 7): The unit will provide either eight (8) switched power outputs, eight (8) dry form C outputs, or any combination of both switched power and form C outputs. (a) Fail-Safe Switched Power outputs: For Fail-Safe operation connect the positive (+) input of the access control devices to terminal marked [NC]. Connect the negative ( ) input of the access control devices to terminal marked [COM]. (b) Fail-Secure Switched Power outputs: For Fail-Secure operation connect the positive (+) input of the access control devices to terminal marked [NO]. Connect the negative ( ) input of the access control devices to terminal marked [COM]. (c) Form C outputs: When form C outputs are desired, the corresponding output fuses (1-8) of each ACM8 board must be removed. 6. ACM8 Auxiliary Power outputs (unswitched): Connect access control devices that require constant power to terminals marked [C] positive (+) and [COM] negative ( ). Outputs can be used to provide power for card readers, keypads etc. eflow Auxiliary outputs (unswitched): For auxiliary device connection this output will not be affected by Low Power Disconnect or Fire Alarm Interface. Connect device to terminals marked [+ AUX ] (Fig. 3, pg. 8). 7. Input trigger options (Fig. 2, pg. 7): (a) Normally Open [NO] input trigger: Inputs 1-8 are activated by normally open or open collector sink inputs. Connect access control panel outputs, keypads, push buttons, REX PIRs, etc. to terminals marked [IN] and [GND]. (b) Open Collector Sink inputs: Connect the access control panel open collector sink positive (+) to terminals marked [IN] and the negative ( ) to terminals marked [GND]. 8. ACM8 Fire Alarm Interface options (Figs. 6-10, pg. 10): A normally closed [NC] or normally open [NO] input trigger from a fire alarm control panel or a polarity reversal input from an FACP signaling circuit will affect selected outputs. To enable FACP Disconnect for an output turn the corresponding switch(es) [SW1-SW8] OFF on each ACM8 board. To disable FACP disconnect for an output turn the corresponding switch(es) [SW1-SW8] on each ACM8 board. (a) Normally Open [NO] input: For non-latching hook-up refer to Fig. 7, pg. 10. For latching hook-up refer to Fig. 8, pg. 10. - 4 - eflowna8 Series

(b) Normally Closed [NC] input: For non-latching hook-up refer to Fig. 9, pg. 10. For latching hook-up refer to Fig. 10, pg. 10. (c) FACP Signaling Circuit input trigger: Connect the positive (+) and negative ( ) from the FACP signaling circuit output to the terminals marked [+ INP ]. Connect the FACP EOL to the terminals marked [+ RET ] (polarity is referenced in an alarm condition). Jumper located next to LED must be cut (Fig. 6, pg. 10). 9. FACP Dry form C output (Fig. 2b, pg. 7) (Not evaluated by UL): Connect desired device to be triggered by the unit s dry contact output to the terminals marked [NO] and [C] FACP for normally open output or the terminals marked [NC] and [C] FACP for normally closed output. 10. Stand-by Battery Connections (Fig. 3, pg. 8): For U.S. Access Control applications batteries are optional. Batteries are required for Canadian installations (ULC-S319). When batteries are not used, a loss of AC will result in the loss of output voltage. When the use of standby batteries is desired, they must be lead acid or gel type. Connect battery to terminals marked [ BAT + ] (Fig. 3, pg. 8). Use two (2) 12VDC batteries connected in series for 24VDC operation (battery leads included). Use batteries - Casil CL1270 (12V/7AH), CL12120 (12V/12AH), CL12400 (12V/40AH), CL12650 (12V/65AH) batteries or UL recognized BAZR2 and BAZR8 batteries of an appropriate rating. 11. Battery and AC Supervision outputs (Fig. 3, pg. 8): It is required to connect supervisory trouble reporting devices to outputs marked [AC Fail, BAT Fail] supervisory relay outputs marked [NC, C, NO] to appropriate visual notification devices. Use 22 AWG to 18 AWG for AC Fail & Low/No Battery reporting. 12. To delay AC reporting for 2 hrs. set dip switch [AC Delay] to OFF position (Fig. 3, pg. 8). To delay AC reporting for 1 min. set dip switch [AC Delay] to position (Fig. 3, pg. 8). 13. Fire Alarm Disconnect (Fig. 3, pg. 8): To enable Fire Alarm Disconnect set dip switch [Shutdown] to position. To disable Fire Alarm Disconnect set dip switch [Shutdown] to OFF position. 14. Installation of tamper switch (Not Included) (Fig. 3a, pg. 8): Mount UL Listed tamper switch (Sentrol model 3012 or equivalent) at the top of the enclosure. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 3a, pg. 8). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 15. Multiple power supply inputs (Fig. 2, pg. 7) (Not evaluated by UL): When using an additional Listed external power supply, jumpers J1 and J2 located on corresponding ACM8 board must be cut (Fig. 2c, 2d, pg. 7 and Fig. 5, pg. 10). Connect external Listed power-limited access control power supply to the terminals marked [ Control +] (These terminals are paralleled to the [ Power +] terminals). When using DC power supplies, polarity must be observed. When using AC power supplies, polarity needs not be observed (Fig. 2d, pg. 7). All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute) (Fig. 4a, pg. 9). Maintenance: Unit should be tested at least once a year for the proper operation as follows: FACP Supervision: To ensure proper connection and operation of the Fire Alarm disconnect hookup please follow the appropriate procedure below: Normally Open Input: Placing a short between terminals marked [T] and [+ INP] will trigger the Fire Alarm Disconnect. Remove the short to reset. Normally Closed Input: Removing the wire from terminal marked [INP ] will trigger the Fire Alarm Disconnect. Replace the wire to terminal marked [INP ] to reset. FACP Signal Circuit Input: It is necessary to trigger the Fire Alarm System. In all of the above scenarios the green LED of the ACM8 will illuminate. All outputs selected for Fire Alarm Disconnect will activate releasing locking devices. Note: All outputs [OUT 1 - OUT 8] must be in a normal (de-energized) condition prior to testing. When the unit is configured for Normally Open (Fig. 8, pg. 10) or Normally Closed (Fig. 10, pg. 10) latching operation, it is necessary to reset the Fire Alarm Disconnect by activating the Normally Closed reset switch. Output Voltage Test: Under normal load conditions the DC output voltage should be checked for proper voltage level (refer to eflowna8 series Configuration Chart, pg. 2). Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage at the battery terminals and at the board terminals marked [ BAT +] to ensure that there is no break in the battery connection wires. Note: Maximum charge current is 1.54A. Expected battery life is 5 years; however, it is recommended to change batteries within 4 years or less if necessary. eflowna8 Series - 5 -

Power Supply/Charger LED Diagnostics: Red (DC) Green (AC/AC1) Power Supply Status Normal operating condition. OFF Loss of AC. Stand-by battery supplying power. OFF No DC output. OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output. Access Power Controller LED OFF LED 1- LED 8 (Red) Output relay(s) energized. Output relay(s) de-energized. Trg (Green) FACP input triggered (alarm condition). FACP normal (non-alarm condition). Power Supply/Charger Terminal Identification: Terminal Legend Function/Description L, N Connect 120VAC 60Hz to these terminals: L to hot, N to neutral. Do not use terminal marked [G] DC + Factory connected to ACM8 board. Trigger EOL Supervised Fire Alarm Interface trigger input from a short or FACP. Trigger inputs can be normally open, normally closed from an FACP output circuit (power-limited input) (Fig. 3, pg. 8). NO, GND RESET FACP interface latching or non-latching (power-limited) (Fig. 3, pg. 8). + AUX Auxiliary Class 2 power-limited output rated @ 1A (unswitched) (Fig. 3, pg. 8). AC FAIL NC, C, NO BAT FAIL NC, C, NO BAT + Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized when AC power is present. Contact rating 1A @ 30VDC (power-limited) (Fig. 3, pg. 8). Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. Contact rating 1A @ 30VDC. A removed battery is reported within 5 minutes. Battery reconnection is reported within 1 minute (power-limited) (Fig. 3, pg. 8). Stand-by battery connections. Maximum charge current 1.54A (non power-limited) (Fig. 3, pg. 8). Access Power Controller Terminal Legend Function/Description 12VDC or 24VDC from power supply/charger (factory connected). Power + These terminals are paralleled to the [ Control +] terminals. These terminals are paralleled to the [ Power +] terminals. They can be connected to an Control + external Listed power-limited access control power supply to provide isolated operating power for the devices (Not evaluated by UL). Jumpers J1 and J2 must be removed. TRIGGER INPUT 1 - INPUT 8 IN, GND OUTPUT 1- OUTPUT 8 NC, C, NO, COM T, + INPUT NC, C, NO From normally open and/or open collector sink trigger inputs (request to exit buttons, exit pir s, etc.) 12VDC to 24VDC trigger controlled outputs: eflow4na8-10.1-13.2vdc @ 3.3A or 20.28-26.4VDC @ 3.6A. eflow6na8-10.0-13.2vdc @ 5.3A or 20.19-26.4VDC @ 5.6A. eflow102na8-10.03-13.2vdc @ 9.3A. eflow104na8-20.17-26.4vdc @ 9.6A. Fail-Safe [NC positive (+) & COM Negative ( )], Fail-Secure [NO positive (+) & COM Negative ( )], Auxiliary output [C positive (+) & COM Negative ( )] (When using AC power supplies polarity needs not to be observed), NC, C, NO convert to dry form C 5A 24VAC/VDC rated dry outputs when fuses are removed. Contacts shown in a non-triggered state. Fire Alarm Interface trigger input from FACP. Trigger inputs can be normally open, normally closed from an FACP signaling circuit output (Figs. 6-10, pg. 10). Form C relay contact rated @ 1A 28VDC for alarm reporting (not evaluated by UL). - 6 - eflowna8 Series

Fig. 1 Power Supply Board Output Voltage Settings: Fig. 1a OFF --- 24V --- 12V Switch Detail Switch On - 12V --- DC + 1 1 1 1 Switch Off - 24V Access Power Controller Typical Application Diagram (ACM8): Fig. 2 Fig. 2a Access Control Panel Output Relay C NO NC Normally Open (N.O.) Door Releasing Device Keypad Intact = Dry Input Cut = Wet Input FACP FACP (Fire Alarm Control Panel) Fig. 2b FACP Dry Form "C" Output F1 IN GND IN GND IN GND IN GND 1 2 3 4 IN GND IN GND IN GND IN GND 5 6 7 8 F2 F3 F4 F5 F6 F7 F8 FACP 1 2 3 4 1 2 3 4 NO C NC + INP --- T + RET - NO C NC FACP SW1-SW8 FACP Interface MAIN Disabled 10A LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 Enabled Mag. Lock J2 J1 --- + Control OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 --- + Power AC or DC Power Supply (req'd.) AC or DC Power Supply (optional) Electric Strike Electromagnetic Door Holders UL Listed Power Supply For this application corresponding fuse F8 must be removed. MAG. LOCK Fig. 2d Fig. 2c Intact = DC Input Cut = AC Input NC C NO COM OUTPUT 8 Intact = One P/S Input Cut = Dual P/S Input J2 J1 --- + Control eflowna8 Series - 7 -

5A L C C 1 2 3 4 1 2 3 4 Fig. 3 Fig. 3a Edge of Enclosure Enclosure Tamper Switch (Not Included) to Access Control Panel or U.L. Listed Reporting Device Tamper Switch Door Green Lead (ground) OFF --- 24V --- 12V --- DC + Observe polarity (eflow4na8 power-limited) (eflow6na8, eflow102na8, eflow104na8 non power-limited) 120VAC power mains Non Powerlimited AC1 Battery & AC Supervision Circuit (Power-limited) BAT FAIL AC FAIL AC Battery Connections (Non Power-limited) DC AC DELAY O N SHUTDOWN --- BAT + Wire Strap (from Enclosure to Door) F1 G N NC Inputs (power-limited) IN GND IN GND IN GND IN GND 1 2 3 4 NO NC unswitched 120VAC power mains (non power-limited) IN GND IN GND IN GND IN GND 5 6 7 8 F2 F3 F4 F5 F6 F7 F8 NO 2 hr. 1 min. disable enable TRIGGER EOL SUPERVISED RESET GND NO AUX + Power-limited NO C NC + INP --- T + RET - Insulating Barrier Fire Alarm Interface (power-limited) MAIN 10A LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8 J2 J1 --- + Control --- + Power OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 DC Output to devices (power-limited for eflow4na8, non power-limited for all other models*) Optional Rechargeable Stand-by Battery for UL294 Applications Note: 12V batteries required for ULC-S319 installations. Optional Rechargeable Stand-by Battery for UL294 Applications Note: 12V batteries required for ULC-S319 installations. CAUTI: When power supply board is set for 12VDC use only one (1) 12VDC stand-by battery. Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. 12AH Rechargeable batteries are the largest batteries that can fit in this enclosure. A UL listed external battery enclosure must be used if using the 40AH or 65AH batteries. - 8 - eflowna8 Series

NEC Power-Limited Wiring Requirements for eflowna8 Models: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power- limited applications use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods. For Canadian installations use shielded wiring for all connections. Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire (Fig. 4a). Fig. 4 Supervisory Connections (power-limited) Input 120VAC 60Hz (non powerlimited) ACM8 outputs* Battery Connections (non power-limited) Optional UL Listed Battery Enclosure (non power-limited) Fig. 4a Incorrect Wire Handling External Jacketed Shield Correct Wire Handling Solid Copper Conductors Wire Insulation Pull back external jacketed shield approx. 1/2. * Outputs are power-limited on eflow4na8. Outputs are non power-limited for eflow6na8, eflow102na8, and eflow104na8. eflowna8 Series - 9 -

FACP Hook-Up Diagrams: Fig. 5 Optional hook-up using two (2) isolated power supply inputs (Only applicable on eflow4na8, not evaluated by UL): CUT JUMPERS J1 AND J2 Fig. 6 Polarity reversal input from FACP signaling circuit output (polarity is referenced in alarm condition): CUT JUMPER J2 J1 ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (ACM8 POWER) ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (LOCK POWER) NO C NC FACP OUTPUT EOL -- FROM FACP + OUTPUT CIRCUIT Fig. 7 Normally Open: Non-Latching FACP trigger input: Fig. 8 Normally Open FACP Latching trigger input with reset (This output has not been evaluated by UL): NO C NC N.O. TRIGGER INPUT NO C NC N.O. TRIGGER INPUT JUMPER N.C. RESET SWITCH Fig. 9 Normally Closed: Non-Latching FACP trigger input: Fig. 10 Normally Closed: Latching FACP trigger input with reset (This output has not been evaluated by UL): NO C NC JUMPER N.C. DRY TRIGGER INPUT JUMPER N.C. RESET SWITCH N.C. TRIGGER INPUT - 10 - eflowna8 Series

Enclosure Dimensions (BC400): 15.5 x 12 x 4.5 (393.7mm x 304.8mm x 114.3mm) 1.5 (38.1mm) 4.615 (117.22mm) 4.615 (117.22mm) 1.5 (38.1mm) 1.75 (44.45mm) 1.375 (34.925mm) 1.125 (28.575mm) 1.25 (31.75mm) 4.5 (114.3mm) 1.1 (27.94mm) 12.23 (310.64mm) 1.1 (27.94mm) 4.5 (114.3mm) 1.25 (31.75mm) 1.5 (38.1mm) 0.91 (23.114mm) 0.91 (23.114mm) 1.5 (38.1mm) 2.0 (50.8mm) 15.5 (393.7mm) 2.0 (50.8mm) 5.0 (127.0mm) 5.0 (127.0mm) 1.25 (31.75mm) 1.1 (27.94mm) 0.79 (20.06mm) 1.25 (31.75mm) 1.75 (44.45mm) 1.5 (38.1mm) 4.615 (117.22mm) 4.615 (117.22mm) 1.5 (38.1mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA phone: 718-567-8181 fax: 718-567-9056 website: www.altronix.com e-mail: info@altronix.com Lifetime Warranty Made in U.S.A. IIeFlowNA8 Series F11R MEMBER eflowna8 Series - 11 -

AC DELAY O N SHUTDOWN eflow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network... LINQ2 LINQ2 - Network Communication Module LINQ2 provides remote IP access to real-time data from eflow power supply/chargers to help keep systems up and running at optimal levels. It facilitates fast and easy installation and set-up, minimizes system downtime, and eliminates unnecessary service calls, which helps reduce Total Cost of Ownership (TCO) - as well as creating a new source of Recurring Monthly Revenue (RMR). Features: - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eflow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature. - Access control and user managment: Restrict read/write, Restrict users to specific resources - Two (2) integral network controlled Form C Relays. - Three (3) programmable input triggers: Control relays and power supplies via external hardware sources. - Email and Windows Dashboard notifications - Event log tracks history. - Secure Socket Layer (SSL). - Programmable via USB or web browser - includes operating software and 6 ft. USB cable. LINQ2 Mounts Inside any eflow Enclosure LINQ2 Module L G N NC C NO NC C NO AC1 BAT FAIL AC FAIL Network Connection: Installation, Programming and Monitoring AC DC TRIGGER EOL SUPERVISED disable enable 2 hr. 1 min. eflow Power Supply/Charger - 12 - eflowna8 Series