dualarm Vertical In-Line Pumps

Similar documents
Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Installation and operating instructions. E.2 Series high efficiency circulator

Full-line Product Overview

E.2 series high efficiency circulator. Installation and operating instructions

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

SECTION STEAM CONDENSATE PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

TECHNICAL. Series 18. Pump Packages

Astro Express 2 - Hot Water Delivery System

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

Horizontal Split Case Pumps Type U

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

MARLOW PUMPS RECIRCULATION

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

TYPE LF/LC/LCV END SUCTION PUMPS

Wilo IL Vertical Split-Coupled Inline Pumps

Astro 2 circulator models. Installation and operating instructions

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

References are in agreement with UMRL dated April 2018 **************************************************************************

SECTION STEAM CONDENSATE PUMPS

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

380 Series Multi-Stage Centrifugal Pumps

Dean Pump High Temperature Chemical Process Inline Pumps

TYPE VL/VLS VERTICAL INLINE PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

SINCE Base Mounted Pump. Series 2000/

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

SECTION PUMPS. 6. Section Steam and Condensate Piping and Specialties.

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Hard-hitting Contenders In HVAC Fluid Handling Solutions

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

KV Vertical Inline Pumps Taco Vertical Inline Pumps meet the latest standards for hydraulic performance and dimensional

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

SECTION DOMESTIC WATER PUMPS

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

HOMA Pump, Ansonia Connecticut

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

FLANGE-MOUNT CENTRIFUGAL PUMPS

Design and Construction Standards SECTION PLUMBING EQUIPMENT

CRN A-F-G-E-HQQE 3x400D 50 HZ

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

1900 Series In-Line Pump

CR A-F-A-E-HQQE 3x400/ HZ

Vertical Heavy Duty Pumps

380 Series Multi-Stage Centrifugal Pumps

TP /4-A-F-A-BQQE 400D 50HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

INSTRUCTION AND REPAIR MANUAL

SECTION PLUMBING EQUIPMENT

Water Piping and Pumps

Condensing boiler plant (vp)

KEENER GRINDER PUMPS

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y VTP. Vertical Turbine Pump

Lenntech. Tel Fax bar. Multistage Pumps.

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

CR A-F-A-E-HQQE 3x400/ HZ

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

Peerless Pump Company

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

Transcription:

Series 430 & 438 dualarm Vertical In-Line Pumps FILE NO: 43d.1 DATE: Jan. 0, 010 SUPERSEDES: 43d.1 DATE: Sept., 008

Series 430 & 438 Smart pumps for the commercial HVAC market. Armstrong Vertical In-Line pump, the best design for HVAC systems, introduced in1969. Armstrong dualarm Vertical In-Line pump, introduced in 1994. dualarm Series 430 & 438 contain all the features and advantages of two Armstrong time proven Vertical In-Line pumps, in one casing. Series 430, shown with one guard removed to reveal outside balanced seal, and a cutaway to show the isolation valve. Adding Value to Hydronic Systems Floor Space Value: In a typical system, for example 1000 USgpm flow at 50 ft head (63.1 L/s at 15. m), the dualarm needs only one quarter of the space required for two end suction base mounted pumps and one eighth the space required for two split case horizontal pumps. Installation Value: Vertical In-Line pumps become an integral component of the piping system. This configuration eliminates the need for flexible connectors, inertia bases, grouting and field alignment. Maintenance Value: Mechanical seals require the greatest amount of maintenance in any pump. Service is performed on any Vertical In-Line pump without removing the casing from the piping. The Series 430 split-spacer coupling design allows the mechanical seals to be serviced without disturbing the pump or motor connections. System Value: Standby and parallel pump systems may now be designed using only one pump piping set. Two pumps in a single large port casing allow both pumps to operate simultaneously, in true parallel fashion, with no loss in single pump efficiency. Design Value: dualarm Vertical In-Line pumps, designed with a swing split-flapper valve in the discharge port, prevent liquid recirculating when only one pump is operating. Unique Armstrong isolation valves allow one pump to be isolated and removed for service while the second pump remains in operation.

Series 430 Designed to incorporate two Armstrong standard Series 4300 split coupled Vertical In-Line pumps in a single casing. All existing 4300 series catalogue information and performance curves may be used, or doubled in the case of parallel operation, for the Series 430 Vertical In-Line pump. Sealing Arrangements Motor - Industry standard, designed for in-line service. Motor shaft - Run-out limited to 0.001 (0.03 mm) TIR (Total Indicated Reading). Coupling - Axially split type spacer permits removal of seal without disturbing pump or motor. Shaft - Stainless Steel with deflection at mechanical seal limited to 0.00 (0.05 mm) TIR. Mechanical seal - Outside balanced or inside type, accessible and easily replaced. Seal plate - Flush connection ensures lubrication at the seal faces and positive venting of seal chamber. Impeller - Dynamically balanced to ensure smooth vibration-free operation. Volute - Radially split, with equal suction and discharge flange sizes. Separate tapped openings for gauge, flush and drain connections. Gasket - Confined casing gasket to meet stringent industrial temperature and pressure applications. Flapper valve - Hydraulically isolates casings preventing recirculation when only one pump operates. Isolation valves - Allow one unit to be isolated and removed for service with the second unit still operating. Coupling guards - Fully enclose all access openings. (Not shown.) Armstrong Series 430 split coupled Vertical In-Line pump is available with two normal mechanical seal arrangements. Each arrangement may be removed quickly and easily for servicing, without costly removal of the motor or rotating assembly from the pump casing. The high performance outside seal combines the advantages of a balanced seal with premium quality. The internal mechanical seal provides an economical alternative. Outside Balanced Mechanical Seal Arrangement 1 5 7 3 4 6 1 Pump Shaft Rotating Hardware 3 Spring(s) 4 Secondary Seal 5 Rotating Face Inside Unbalanced Mechanical Seal Arrangement 1 7 6 5 4 6 Stationary Seat 3 8 7 Gland Plate 8 Throttle Bushing 8

Series 438 dualarm Vertical In-Line Pumps Designed to incorporate two Armstrong standard Series 4380 close coupled Vertical In-Line pumps in a single casing. All existing 4380 series catalogue information and performance curves may be used, or doubled in the case of parallel operation, for the Series 438 Vertical In-Line pump. Sealing Arrangements Motor - Industry standard, designed for in-line service. Flush and vent connection - Removes entrained air ensuring lubricating liquid is at the seal faces at all times. Piped to pump suction. Mechanical seal - Inside type with Silicon Carbide seat, serviceable without disturbing the pipe connections. Impeller - Dynamically balanced to ensure smooth vibration-free operation. Volute - Radially split, with equal suction and discharge flange sizes. Separate tapped openings for gauge, flush and drain connections. Gasket - Confined casing gasket to meet stringent industrial temperature and pressure applications. Flapper valve - Hydraulically isolates casings preventing recirculation when only one pump operates. Isolation valves - Allow one unit to be isolated and removed for service while the second unit remains in operation. Armstrong Series 438 close coupled Vertical In-Line pump is supplied with an economical internal single spring unbalanced mechanical seal. The seal is serviced by removing the rotating element from the casing. The pump casing typically remains in the piping. Motor Shaft Shaft Sleeve Stationary Seat Secondary Seal Rotating Face Spring Rotating Hardware dualarm Pressure/Temperature Parameters Legend A B 430 BF & DBF 438 BF & DBF 430 BF & DBF All seals supplied with Silicon Carbide seats. NOTES: For clean untreated water. For pumping temperatures above 00ºF, longer mechanical seal life can be achieved on Series 430 if flushing liquid is cooled by an external heat exchanger to maintain seal flush water below 00ºF.

Armstrongest System Value Armstrong dualarm Vertical In-Line pumps, when installed with Armstrong Suction Guides 1 and Armstrong Flo-Trex combination valves, result in the greatest added value and lowest life cycle cost of any equipment that can be designed into today s commercial, industrial, HVAC and packaged systems. 1 The Armstrong Suction Guide, designed with flow stabilizing plates in the outlet port, allows the guide to be bolted directly onto the pump suction flange, enabling the vertical piping to turn 90 into the pump. A disposable fine mesh start-up strainer and permanent perforated stainless steel strainer complete this valuable fitting. The Suction Guide eliminates the need for a separate suction strainer, long radius elbow and minimum straight pipe run to the pump suction. The Armstrong Flo-Trex triple function combination valve is designed to operate equally as a non-slam check valve, drip tight isolation valve and properly designed throttling valve. The throttling feature enables a system head increase to operate the pump at design conditions. The Armstrong uniquely designed valve is field convertible from 90 angle type to 180 straight type. The Flo-Trex combination valve eliminates the need for a discharge elbow, a separate check valve and a throttling type isolation valve. Armstrong Flo-Trex Combination Valve 1 Armstrong Suction Guide Armstrong dualarm Vertical In-Line Pump

Typical Specifications Series 430 Split Coupled Vertical In-Line Pump Supply and install as shown on the plans and specifications, Armstrong Series 430 dualarm split coupled Vertical In-Line centrifugal pumping unit. The cast casing with equal size suction and discharge flanges, having separate tapped flush line and pressure gauge connections, shall incorporate two radially split, single stage centrifugal pumps. Each pump shall have a cast bronze dynamically balanced impeller, stainless steel shaft, lower seal flush throttle bushing, outside balanced mechanical seal with stainless steel parts, Viton secondary seal, carbon vs silicone carbide faces and stainless steel gland plate and hardware. Each pump shall be fitted with a factory furnished flush line to the mechanical seal. The flush line is to be fitted with a manual air vent. Each driving motor shall be an industry standard vertical solid shaft, squirrel cage induction type, built to NEMA standards (motor efficiency levels may be specified). The motor shall have enclosure and be suitable for a Hz, Phase, Volt power supply and shall be connected to the pump by means of a rigid split type spacer coupling that permits removal of the mechanical seal without disturbing the pump or motor connections. The inlet and outlet ports on the casing shall be at least one size larger than the single pump size, so that both units may operate in parallel with no loss of single pump efficiency. Each port shall be fitted with an isolation valve that allows the units to operate in parallel or standby. It may also be used to isolate one pumping unit for servicing or removal, while the other pump remains operating. Series 438 Close Coupled Vertical In-Line Pump Supply and install as shown on the plans and specifications, Armstrong Series 438 dualarm close coupled type Vertical In-Line centrifugal pumping unit. The cast casing with equal size suction and discharge flanges, having separate tapped flush line and pressure gauge connections, shall incorporate two radially split, single stage centrifugal pumps. Each pump shall have a cast bronze dynamically balanced impeller, bronze shaft sleeve and inside type single spring mechanical seal with carbon vs silicone carbide faces. Each pump shall be complete with a factory furnished flush and vent line. Each driving motor shall be an industry standard vertical solid shaft, squirrel cage induction type, built to NEMA standards (motor efficiency levels may be specified). The motor shall have enclosure and be suitable for a Hz, Phase, Volt power supply. The inlet and outlet ports on the casing shall be at least one size larger than the single pump size, so that both units may operate in parallel with no loss of single pump efficiency. Each port shall be fitted with an isolation valve that allows the units to operate in parallel or standby. It may also be used to isolate one pumping unit for servicing or removal, while the other pump remains operating. Flush line option: Supply in the flush line to the mechanical seal a 50 micron cartridge type filter (if the differential pressure exceeds 30 psig [ bars], a Cyclone separator may be specified) and a sight flow indicator. The mechanical contractor shall change the filter cartridge after the system has been flushed and on a regular basis thereafter, until the building is turned over to the owner. S. A. Armstrong Limited 3 Bertrand Avenue Toronto, Ontario Canada, M1L P3 T: (416) 755-91 F (Main): (416) 759-9101 Armstrong Pumps Inc. 93 East Avenue North Tonawanda, New York U.S.A., 1410-6594 T: (716) 693-8813 F: (716) 693-8970 Armstrong Holden Brooke Pullen Wenlock Way Manchester United Kingdom, M1 5JL T: +44 (0) 161 3 3 F: +44 (0) 161 0 9660 S.A. Armstrong Limited 010 For Armstrong locations worldwide, please visit www.armstrongintegrated.com