AKOCABLE Heating Cable Solutions Electrical Tracing

Similar documents
AKOCable Heating Cable Solutions Electrical Tracing

Documentation. Parallel Heating Cable. Type: ELP

Drexan Energy Systems Inc.

Heating Cables and Tapes. Technology. Constant wattage tapes

First Trace Heating Product Details

Technology for human beings that is, compatible with nature, creating permanent HEAT TRACING Dreams that can greatly improve the quality of life,

F1202 TRACE HEATING. Road & Ramp

Technical Databook for Industrial Heat-Tracing Systems 2006/2007

Freezer Frost Heave Prevention

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Longline Heating. Contents. Introduction

Chromalox PRECISION HEAT AND CONTROL. Cold Weather Electric Heat and Control Products

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

INDUSTRIAL HEAT TRACE

Toll Free:

PLSRR Heat Trace Cable Data Sheet

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

HEATERS & SENSORS INC. - CATALOG

XL-Trace System Application and Design Guide

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Toll Free:

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Technical Databook for Industrial Heating Systems

Consignes d installation

Self-regulating Roof Heat and Gutter Trace Cable

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

Technology. Heating Panels ZIEGLER ENGINEERING. Silicone heating panel (200 C)

C Electrical Connection Kit

Self-regulating Roof Heat Cable

Roof and Gutter De-Icing

Toll Free:

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

Principle of Operation:

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Heating cable solutions for temperature-related problems

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

HOTFOIL HB MODULE HEATING SYSTEM INSTALLATION, OPERATION & MAINTENANCE MANUAL HB.IOM.R3

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

SILICONE RUBBER HEATERS

Parallel Heating Cables Standard types... 24

Polymer solutions Heating mat EM2-CM

Data Sheet. Self regulating process heating tapes RS stock numbers ,

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

Snow melting for ramps, access ways, and footpaths

Design Guide and Installation Details for Self-Regulating Heating Cable

KE-Series Constant-Wattage Heating Cable

Domestic Hot Water Application manual

Department of General Services Real Estate Services Division Professional Services Branch Additional Detailed Instructions (ADI)

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

SERGE BARIL HEAT TRACING SYSTEMS

Flanged Immersion Heaters

VACUUM VALVES AND HOSES

Flanged Immersion Heaters

Flanged Immersion Heaters

1SC-SSC Splice Connection Kit Installation Instructions

DESIGN GUIDELINES. THERMAL building SOLUTIONS

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

AlarmLine Linear Heat Detector

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

Cartridge Heaters. Hi-Density Cartridge Heaters. Features. To order, call or shop online at omega.com SM

DESTU. Direct Entry Sealed Termination Unit. Installation Instructions. Suitable for use in either safe or hazardous areas.

FTC-HST WARNING: CAUTION:

Heating Mats and Jackets. innovations in heat tracing

Thermal Devices, Inc. Mount Airy, Maryland USA Heating Cable. Cut to Length in Field

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Frost Heave Protection System Installation and Operation Manual

DHCSR Series Drum / Pail Heaters

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Ceramic Fiber Heaters

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Commercial and Residential Self-Regulating Heating Products

Data Sheet. Self regulating heating tapes. RS stock numbers

NELSON HEAT TRACING SYSTEMS

Anti frost. Snow Melting USA 2012 USA 2014

Raychem Heating System

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

NELSON HEAT TRACING SYSTEMS

ELECTRIC HEATING THERMOSYSTEM

NJWEA TECH TRANSFER MARCH 1, 2016

Overview Frost Heave Prevention for Freezer floors on ground.

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

HSHP HIGH PERFORMANCE DRUM HEATER

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

CATALOG. Toll Free:

DISTRIBUTOR GUIDE FOR SELLING QUALITY TO CONTRACTORS

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

Phoenix Thermal Supply

Transcription:

AKOCABLE Heating Cable Solutions Electrical Tracing

www.ako.com AKOCABLE HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer cover Used in long tracing systems Constant wattage Parallel type heating cable The heating cable may be cut to size on site without changing its linear power. Self-regulating Used in the majority of temperature maintenance applications Constant wattage heating cable PVC insulation Up to 70ºC with PVC high temperature insulation. PVC insulation. Copper conductors 2 x 1.5 mm 2. Nominal outer dimensions 7 x 9.5 mm. Suitable for low temperature applications. Application: Construction and refrigeration Minimum bend radius at 15ºC: 20 mm Heating conductor element: Nickel - Chromium Distance between contacts: 1000 mm Maximum insulation temperature: 70 ºC AKO-12193 AKO-12193 Kit para extremos Splice kit to de conexión box + a end caja + final AKO-12192 Kit Splice de kit empalme + end + final AKO-5238 Termination Kit de terminación kit AKO-5231 Heating cable 10W/m to 230V, PVC insulation 2110 100 m. (A) AKO-1212 Heating cable 20W/m to 230V, PVC insulation 2110 100 m. (A) AKO-12192 Splice kit + end 2190 1 Unit AKO-12193 Splice kit to box + end 2190 1 Unit AKO-5238 Termination kit 2190 25 Units 47

AKOCABLE Constant wattage heating cable Silicon insulation Up to 70ºC with silicone insulation. Suitable for avoiding ice in pipes and metal surfaces or for heating not exceeding 55ºC on them. It can be cut to size. They are commonly used in industrial or commercial refrigeration installations to avoid ice in the drain pipes, condensation on the surface, and in applications on metal surfaces not exceeding 55 C. Application: Refrigeration Extremo Cold frío connection de conexión end AKO-52383 Kit Termination de terminación kit Heating Tramo length calefactor Extremo Termination final end Minimum bend radius at 25ºC: 20 mm Heating conductor element: Nickel - Chromium Distance between contacts: 1000 mm Maximum circuit length: 60 m Maximum operating temp. (connected): 55ºC Maximum exposure temp. (disconnected): 70ºC AKO-5234 Heating cable 30W/m at 230V, silicone insulation 2110 150 m. (A) AKO-52342 Heating cable 30W/m at 120V, silicone insulation 2110 150 m. (A)* AKO-52344 Heating cable 40W/m at 230V, silicone insulation 2110 150 m. (A)* AKO-52346 Heating cable 65W/m at 230V, silicone insulation 2110 75 m. (A)* AKO-52383 Kit for sealing connection termination + end 2190 25 Units * Available on request Constant wattage heating cable Silicon insulation Up to 180ºC with silicone insulation. PVC insulation. Copper conductors 2 x 1.5 mm 2. Nominal outer dimensions 7 x 9.5 mm. Suitable for low temperature applications. Application: Construction and refrigeration Minimum bend radius at 25ºC: 20 mm Heating conductor element: Nickel - Chromium Distance between contacts: 1000 mm Maximum circuit length: 70 m Maximum exposure temperature (disconnected): 70ºC AKO-12193 Kit Splice para kit extremos to box de + conexión end a caja + final AKO-12192 Kit Splice de kit empalme + end + final AKO-5238 Termination Kit de terminación kit AKO-712545 Heating cable 50W/m to 230V, silicone insulation 2110 100 m. (A) AKO-12192 Splice kit + end 2190 1 Unit AKO-12193 Splice kit to box + end 2190 1 Unit AKO-5238 Termination kit 2190 25 Units 48

www.ako.com AKOCABLE Constant wattage heating cable Silicone insulation + metal braid Up to 70ºC with metal protection braid. A range with braid, giving mechanical and electrical protection by using it as an earth conductor. It can be cut to size. They are commonly used in industrial or commercial refrigeration installations to avoid ice in the drain pipes, condensation on the surface, and in applications on metal surfaces not exceeding 55 C. Application: Refrigeration AKO-52383 Termination Kit de terminación kit Minimum bend radius at 25ºC: 20 mm Heating conductor element: Nickel - Chromium Outer dimensions: 8.2 x 5.7 mm Maximum circuit length: 60 m Maximum operating temperature (connected): 55ºC Maximum exposure temperature (disconnected): 70ºC Extremo Cold frío connection de conexión end Heating Tramo length calefactor Extremo Termination final end AKO-52341 Heating cable 30W/m to 230V, insulation + metal braid 2110 150 m. (A) AKO-52383 Kit for sealing connection termination + end 2190 25 Units Constant wattage heating cable Silicone insulation + metal braid Up to 180ºC with metal protection braid. A range with braid, giving mechanical and electrical protection by using it as an earth conductor. It can be cut to size. They are usually used in heating to maintain the temperature of pipes, tanks, etc. in protection against freezing, maintaining process temperatures of up to 165 C and especially in areas that are not corrosive or atmospheres classified as potentially explosive. Application: Industry and construction Up Hasta to 180ºC AKO-71092 Kit for para connection extremos ends to de conexión box + end a caja sealing+ final Minimum bend radius at 40ºC: 20 mm Heating conductor element: Nickel - Chromium Outer dimensions: 6.9 x 9.4 mm Maximum operating temp. (connected): up to 165ºC Maximum exposure temp. (disconnected): 180ºC AKO-71010 Heating cable 10W/m to 230V 2110 100 m. (A) AKO-71015 Heating cable 15W/m to 230V 2110 100 m. (A) AKO-71020 Heating cable 20W/m to 230V 2110 100 m. (A) AKO-71025 Heating cable 25W/m to 230V 2110 100 m. (A) AKO-71030 Heating cable 30W/m to 230V 2110 100 m. (A) AKO-71035 Heating cable 35W/m to 230V 2110 100 m. (A) AKO-71050 Heating cable 50W/m to 230V 2110 100 m. (A) AKO-71092 Kit for connection ends to box + end sealing 2190 1 Unit 49

AKOCABLE Constant wattage heating cable Silicone insulation + metal braid 24/48V with metal protection braid. A range with braid, giving mechanical and electrical protection by using it as an earth conductor. It can be cut to size. They are usually used in heating to maintain the temperature of pipes, tanks, etc. in protection against freezing, maintaining process temperatures of up to 165 C and especially in areas that are not corrosive or atmospheres classified as potentially explosive. Application: Industry and construction Hasta Up to 180ºC Minimum bend radius at 25ºC: 20 mm Heating conductor element: Nickel - Chromium Outer dimensions: 7 x 9.5 mm Maximum operating temperature (connected): 55ºC Maximum exposure temperature (disconnected): 180ºC AKO-71092 Kit Kit for para connection extremos ends to de conexión box + end a caja sealing+ final AKO-5237 Heating cable 40W/m to 48V, (10W/m to 24V) 2110 100 m. (A)* AKO-71092 Kit for connection ends to box + end sealing 2190 1 Unit * Available on request Constant wattage heating cable Fluoropolymer covering Up to 30ºC with fluoropolymer cover Follow the AKO usage instructions. It can be cut to size. These are used to maintain the temperature and protection against ice in pipes, on roofs, terraces, ramps, stairs, drains, etc. Application: Construction Minimum bend radius at 40ºC: 20 mm Heating conductor element Nickel - Chromium Outer dimensions 6.5 x 9 mm Maximum operating temperature (connected) up to 30ºC Maximum exposure temperature (disconnected) 180ºC AKO-70194 Kit for para connection extremos ends de to conexión M20 box a + caja end + final AKO-70192 Kit Splice de kit empalme + end + final Hasta Up to 180ºC 30 AKO-70115 Heating cable 15W/m to 230V 2110 100 m. (A) AKO-70130 Heating cable 30W/m to 230V 2110 100 m. (A) AKO-70140 Heating cable 40W/m to 230V 2110 50 m. AKO-70192 Splice kit + end, for cables embedded in concrete 2190 10 Units AKO-70194 Kit for connection ends to box + end sealing 2190 5 Units (B) Minimum, indivisible pack units. 50

www.ako.com AKOCABLE Constant wattage heating cable Fluoropolymer covering Up to 200ºC with fluoropolymer cover. Suitable for corrosive atmospheres and with risk of explosion, when following the AKO usage instructions. It can be cut to size. They are usually used in heating to maintain the temperature of pipes, tanks, etc. in protection against freezing, maintaining process temperatures up to 190 C and especially in installations with highly corrosive atmospheres, in plastic pipes and tanks, and in areas classified as potentially explosive atmospheres. Application: Industry Up Hasta to 200 200ºC AKO-71092 Kit for para connection extremos ends de to conexión box a + caja end + sealing final Minimum bend radius at 40ºC: 20 mm Heating conductor element Nickel - Chromium Outer dimensions 7.2 x 10.2 mm Maximum operating temperature (connected): up to 190ºC Maximum exposure temperature (disconnected): 200ºC AKO-71110 Heating cable 10W/m to 230V 2110 100 m. (A) AKO-71115 Heating cable 15W/m to 230V 2110 100 m. (A) AKO-71120 Heating cable 20W/m to 230V 2110 100 m. (A) AKO-71125 Heating cable 25W/m to 230V 2110 100 m. (A) AKO-71130 Heating cable 30W/m to 230V 2110 100 m. (A) AKO-71135 Heating cable 35W/m to 230V 2110 100 m. (A) AKO-71150 Heating cable 50W/m to 230V 2110 100 m. (A) * AKO-71092 Kit for connection ends to box + end sealing 2190 1 Unit * Available on request Self-regulating heating cable Polyolefin insulation Up to 85ºC with braid for ground connection. Suitable for dry or damp atmospheres, but not corrosive. Area classification: ordinary. Maximum temperature for continuous exposure: 65ºC. Application: Industry and refrigeration Minimum bend radius at 20ºC: 30 mm Outer dimensions: 5 x 12 mm Maximum operating temperature (connected): 65ºC Maximum exposure temperature (disconnected): 85ºC AKO-12292 Kit Kit para for connection extremos de ends conexión to a caja box + final end sealing AKO-122906 Kit Splice de empalme kit AKO-5239 Termination Kit de terminación kit AKO-1221 Heating cable 25W/m to 10ºC, 230V (11W/m, 40ºC) 2120 100 m. (A) AKO-12292 Kit for connection ends to box + end sealing 2190 1 Unit AKO-122906 Splice kit 2190 1 Unit AKO-5239 Termination kit 2190 25 Units 51

AKOCABLE Self-regulating heating cable Fluoropolymer covering Up to 85ºC suitable for Ex zone. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 65ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is NOT performed. Application: Industry and refrigeration M20 AKO-71285 AKO-71282 Minimum installation temperature: 60ºC Minimum bend radius: 32 mm Maximum operating temperature (connected): 65ºC Maximum exposure temperature (disconnected): 85ºC AKO-71212 Heating cable 9W/m to 10ºC, 230V (4W/m, 40ºC) 2120 AKO-71214 Heating cable 15W/m to 10ºC, 230V (7W/m, 40ºC) 2120 AKO-71216 Heating cable 25W/m to 10ºC, 230V (12W/m, 40ºC) 2120 AKO-71218 Heating cable 32W/m to 10ºC, 230V (17W/m, 40ºC) 2120 AKO-71219 Heating cable 48W/m to 10ºC, 230V (22W/m, 40ºC) 2120 AKO-71281 Termination kit for AKO-71219 heating cables 2190 1 Unit AKO-71282 Termination kit for heating cables 2190 1 Unit AKO-71285 Glands for connecting heating cables 2190 1 Unit AKO-71287 Glands for connecting AKO-71219 heating cables 2190 1 Unit Self-regulating heating cable Fluoropolymer insulation and covering Up to 250ºC, suitable for Ex zone. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 121ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is performed. Minimum installation temperature: -60 ºC Minimum bend radius: 32 mm Maximum operating temperature (connected): 121ºC Maximum exposure temperature (disconnected): 205ºC Maximum exposure temperature (intermitent): 250ºC M20 AKO-71286 AKO-71282 AKO-71241 Heating cable 14W/m to 10ºC, 230V (5W/m, 100ºC) 2120 AKO-71243 Heating cable 30W/m to 10ºC, 230V (11W/m, 100ºC) 2120 AKO-71245 Heating cable 48W/m to 10ºC, 230V (24W/m, 100ºC) 2120 AKO-71248 Heating cable 64W/m to 10ºC, 230V (28W/m, 100ºC) 2120 AKO-71282 Termination kit for heating cables 2190 1 Unit AKO-71286 Glands for connecting heating cables 2190 1 Unit 52

www.ako.com AKOCABLE Self-regulating heating cable Fluoropolymer insulation and covering Up to 250ºC, suitable for Ex zone. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 121ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is performed. Minimum installation temperature: -60 ºC Minimum bend radius: 32 mm Maximum operating temperature (connected): 121ºC Maximum exposure temperature (disconnected): 205ºC Maximum exposure temperature (intermitent): 250ºC M20 AKO-71286 AKO-71282 AKO-71250 Heating cable 9W/m to 10ºC, 230V (3W/m, 100ºC) 2120 AKO-71251 Heating cable 18W/m to 10ºC, 230V (6W/m, 100ºC) 2120 AKO-71252 Heating cable 27W/m to 10ºC, 230V (11W/m, 100ºC) 2120 AKO-71253 Heating cable 37W/m to 10ºC, 230V (16W/m, 100ºC) 2120 AKO-71255 Heating cable 48W/m to 10ºC, 230V (24W/m, 100ºC) 2120 AKO-71258 Heating cable 64W/m to 10ºC, 230V (40W/m, 100ºC) 2120 AKO-71282 Termination kit for heating cables 2190 1 Unit AKO-71286 Glands for connecting heating cables 2190 1 Unit Self-regulating heating cable Fluoropolymer insulation and covering Up to 250ºC, suitable for Ex zone. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 150ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is performed. M20 AKO-71287 Minimum installation temperature: 60ºC Minimum bend radius: 32 mm Maximum operating temperature (connected): 150ºC Maximum exposure temperature (disconnected): 204ºC Maximum exposure temperature (intermitent): 250ºC AKO-71281 AKO-71261 Heating cable 15W/m to 10ºC, 230V ( 5W/m. 120ºC) 2120 AKO-71263 Heating cable 32W/m to 10ºC, 230V (10W/m. 120ºC) 2120 AKO-71265 Heating cable 48W/m to 10ºC, 230V (18W/m. 120ºC) 2120 AKO-71267 Heating cable 64W/m to 10ºC, 230V (25W/m. 120ºC) 2120 AKO-71281 Termination kit for heating cables 2190 1 Unit AKO-71287 Glands for connecting heating cables 2190 1 Unit 53

AKOCABLE Self-regulating heating cable Fluoropolymer insulation and covering Up to 260ºC, in glass fiber and fluoropolymer covering. Adjust power output in line with the temperature in the pipe. It can be cut to size. Maximum temperature for continuous exposure: 149ºC. For electric heating of pipes and tanks, in maintaining temperatures when steam cleaning is performed. Application: Industry and refrigeration M20 AKO-71286 AKO-71283 Minimum installation temperature: 60 ºC Minimum bend radius: 57 mm Maximum operating temperature (connected): 149ºC Maximum exposure temperature (disconnected): 260ºC AKO-71270 Heating cable 14W/m to 10ºC, 230V (10W/m, 120ºC) 2120 AKO-71271 Heating cable 28W/m to 10ºC, 230V (18W/m, 120ºC) 2120 AKO-71275 Heating cable 42W/m to 10ºC, 230V (28W/m, 120ºC) 2120 AKO-71279 Heating cable 57W/m to 10ºC, 230V (38W/m, 120ºC) 2120 AKO-71283 Termination kit for heating cables. Exp. up to 200ºC 2190 1 Unit AKO-71286 Glands for connecting heating cables 2190 1 Unit Series cable Mineral insulation Up to 500ºC with mineral insulation. Magnesium oxide insulation. Stainless steel exterior covers. Sufficient flexibility to adapt it to surfaces. These kinds of cables are used to heat pipes, tanks, hoppers and other processing equipment up to 530 ºC and in cases where cables must withstand up to 600 ºC with the cables disconnected. Minimum bend radius at 20ºC: 32 mm Stainless steel exterior cover Cold terminations of 1.5 m Heating elements of 12 and 20 m 150 mm 1500 mm 1500 mm 150 mm M20 Extremo Cold connection frío para conexión end Longitud Heating zona calefactora length M20 Extremo Cold connection frío para conexión end AKO-71301A Heating cable 12 m long, 440W, 230V, up to 530ºC 2130 1 Unit AKO-71302A Heating cable 20 m long, 1537W, 230V, up to 480ºC 2130 1 Unit 54

www.ako.com AKOCABLE Series cable Quartz fiber insulation Up to 800ºC with quartz fiber insulation Quartz fiber insulation. Very flexible to adapt it to very small pipes. Installation in dry places with no risk of humidity. These kinds of heating cables are suitable for heating pipes and surfaces up to a maximum temperature of 800 C. Minimum bend radius at 20ºC: 10 mm Cold ends of 1.5 m Maximum operating temperature (connected): 800ºC Maximum exposure temperature (disconnected): 900ºC Extremo Cold connection frío para conexión end Extremo Cold connection frío para conexión end 1,5 m Longitud Heating zona length calefactora 1,5 m AKO-71321 Heating cable 1 m long., 170W, 230V, up to 800ºC 2130 1 Unit AKO-71323 Heating cable 3 m long., 500W, 230V, up to 800ºC 2130 1 Unit AKO-71325 Heating cable 5 m long., 800W, 230V, up to 800ºC 2130 1 Unit Heaters Heating panels Flexible pipes up to 185ºC for heating tanks and surfaces. Power outputs of 375 W and 875 W. Installed on galvanized metal fabric. They are used to maintain the temperature in horizontal tanks. Nominal dimensions 800 x 1620 mm Maximum exposure temperature (connected) up to 185ºC Maximum exposure temperature (disconnected) up to 200ºC AKO-71515 Panel 0.8 x 1.62 m, 375W, 230V, up to 185ºC 2150 1 Unit AKO-71535 Panel 0.8 x 1.62 m, 875W, 230V, up to 132ºC 2150 1 Unit 55

AKOCABLE Heaters Heating bands Flexible pipes for heating metal drums. For standard metal drums from 25 to 200L. Powers from 300W to 1000W. Easy to fix the drum. They are usually used to melt solids, liquate viscous materials and maintain the temperature of contained products. Power supply cable 1.5 m Heating uniformly spread Silicone insulation with glass fiber AKO-80034 Band 1000W, 230V, for 200l drums (125 x 1665 mm) 2150 2 Units AKO-80035 Band 800W, 230V, for 105l drums (125 x 1300 mm) 2150 1 Unit AKO-80036 Band 500W, 230V, for 50l drums (125 x 940 mm) 2150 1 Unit AKO-80037 Band 300W, 230V, for 25l drums (125 x 800 mm) 2150 1 Unit Calentadores Manta Calefactora Container heaters to 1000L square tanks This heater jacket has quick release adjustable buckles for ease of installation and removal and is designed. with upper and lower heat zones, each with separate thermostatic control. This allows for the upper heating zone to be switched off once the content level has fallen below half way. Power supply cable 2 x 2,5 m Two circuits each 1000W to 230V Temp. Control from 0ºC to 90ºC Top cap included AKO-80041 Container heater to 1000l square tanks, 2x1000W, 230V 2150 1 Unit 56

www.ako.com AKOCABLE Heaters Drum heaters For products highly sensitive to temperature in a safe area. Carbon steel diffuser, thermal insulation of 40 mm of glass fiber. They have guides that allow them to be stacked to achieve the required height. Gentle product heating. They are used to melt solids and liquate viscous materials or materials that are problematic due to their sensitivity to heat, such as greases, glucose, honey, tar, paints, varnishes, phenols, waxes, etc. AKO-718520 AKO-718510 Power cable: 3 m, 3 x 2.5 mm 2 Power up to 3170 W per drum Outer diameter: 750 mm Inner diameter: 620 mm Height: 440 mm AKO-718510 Base heater 720W. 230V 2150 1 Unit AKO-718520 Ring heater 1.100W. 230V 2150 1 Unit Heaters Drum heaters For products highly sensitive to temperature in the Ex area. Carbon steel diffuser, thermal insulation of 40 mm of glass fiber. They have guides that allow them to be stacked to achieve the required height. Gentle product heating. They are used to melt solids and liquate viscous materials or materials that are problematic due to their sensitivity to heat, such as greases, glucose, honey, tar, paints, varnishes, phenols, waxes, etc. Power cable: 3 m, 3 x 2.5 mm 2 Power up to 2200 W per drum Outer diameter: 750 mm Inner diameter: 620 mm Height: 440 mm AKO-718720 Ring heater 1100W, to 10ºC with self-regul. cable Ex 2150 1 Unit 57

AKOCABLE Accessories Junction boxes and supports Junction boxes, fixing supports and protectors for crossing lagging. Plastic boxes very resistant to corrosion and suitable for outdoor installation. Stainless steel support for fixing to boxes. Kits for crossing lagging, used to prevent the heating cables from being damaged., construction and refrigeration AKO-71612 Junction box with 1 M20 input and 1 M12, for probes 2190 1 Unit AKO-71611 Junction box with 4 inputs, ordinary area 2190 1 Unit AKO-71617 Junction box with 4 inputs, Ex area 2190 1 Unit AKO-71620 Cable protector in pipe lagging 2190 5 Units AKO-71625 Support for fixing boxes to the AKO-71620 protector 2190 5 Units AKO-71628 Protector for heating cables in sharp edges 2190 20 Units AKO-71629 Cable protector in tank lagging 2190 1 Unit AKO-717425 Support for fixing boxes and controllers 2190 1 Unit AKO-1901 Set screw + accom. for clamps 4900 50 Units (B) AKO-1903 Stainless steel tape to truss clamp 4900 30 m (B) (B) Minimum, indivisible pack units. Accessories Thermostats and accessories for installing heating cables. A range of accessories for sealing, fixing, signalling and identifying heating cables makes their installation easy on pipes, tanks and surfaces in general. and construction AKO-712699 Tube of high temperature sealing silicone 2190 5 Units AKO-71630 Support for heating cable in vertical tanks 2190 1 Unit AKO-71635 Installation support for heating cables on roofs and gutters 2190 10 Units AKO-71666 Self-vulcanising sealing tape 2190 10 Units AKO-717440 50m roll of aluminium adhesive tape 2190 1 Unit AKO-717441 33m roll of glass fiber adhesive tape 2190 5 Units AKO-717445 Set of 5 AKO-TRACE signalling labels 2190 1 Unit AKO-71751 Set of 5 heating section identification labels 2190 1 Unit 58

www.ako.com AKOCABLE Accessories Heat shrinkable sleeves With hot-weld glue for humidity-proof seals They are used to seal and protect cable splices from humidity. Retracts up to 33% of its original size Contraction temperature >125ºC Operating temperature from 30ºC to +80ºC Flexible modified polyolefin material black with interior hot-weld glue AKO-52401 Heat shrinkable sleeve diameter 12/4 mm, length 1.2 m 2190 30 Units AKO-52402 Heat shrinkable sleeve diameter 12/4 mm, length 50 mm 2190 100 Units AKO-52403 Heat shrinkable sleeve diameter 6/2 mm, length 1.2 m 2190 30 Units AKO-52404 Heat shrinkable sleeve diameter 6/2 mm, length 75 mm 2190 100 Units 59