VMD Guide for V960 Series Cameras

Similar documents
VMD Guide for MP-980 Cameras

VMD Guide for MP-980 Cameras

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide

Milestone XProtect Alarm Matrix Integration 1.0

Warning: To reduce a risk of fire or electric shock, do not expose this product to rain or moisture.

Avigilon Control Center 5 System Integration Guide

CompleteView SightLogix Sensor Setup Manual. CompleteView Version 4.7.1

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Avigilon Control Center 5 System Integration Guide

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Milestone XProtect Alarm Matrix Integration 1.0

Please use authentic SATA hard drive, USB device and battery.

i-vu CCN 4.0 Owner s Guide

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

Ademco Vista Alarm Panel

Appendix 3 Thermostats

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

System Galaxy Quick Guide

Integration with Mobotix Q24

Mobile App & Customer Web Portal. Quick Start Guide

Welcome to MultiSight TM Vision Sensor Hands-On Lab

Honeywell Enterprise Alpha version 5.86

NeXT is a powerful stand-alone application running fully embedded in network cameras to perform an intelligent video surveillance for ATM devices.

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Avigilon Control Center 5 System Integration Guide. with STENTOFON AlphaCom. INT-STENTOFON-C-Rev1

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Configuring Alarm Rule for Video Analytics Detector

Recording Server PRELOADED

Avigilon Control Center 5 System Integration Guide

TOUCH PANEL INSTRUCTION MANUAL

Configuring IndigoVision Control Center. Configuring IndigoVision Control Center

OnGuard 7.1 Resolved Issues

Chapter. Configuring Cisco VSMS. Versions 5.1, 6.0. Configuring Third-Party Programs. SightLogix, Inc

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Monitor Alarms and Events

FCD-wire Contents. List of Figures

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Added password for IP setup page : Password must be in IP format!

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Chapter. Configuring OnSSI NetDVMS. OnSSI NetDVMS versions 5.x through 6.5g. OnSSI NetDVMS Ocularis. Configuring Third-Party Programs

User s Guide. Manual P/N Rev No. 2, 04/11

Bosch TCU Integration Module Administrator's Guide

MODEL V5160MUX 16-CHANNEL DIGITAL COLOR MULTIPLEXER

Moxa Proactive Monitoring User s Manual

Security Management System Configuring TCP-IP MODBUS Inputs

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

Integration Test Plan

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

rvm4c Installation Guide Remote Video Module

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Access CONTROL. MANAGEMENT Software

Alarms Updated 03/26/2018

Avigilon Control Center System Integration Guide

Skipper's Mate. Sensor Testing. Version December Table of Contents

HikCentral Web Client. User Manual

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

Security Management System - Configuring Video Analytics

D3D Wi-Fi GSM Smart Alarm System -User Manual

D-Link Central Management System

Simplex Panel Interface Guide

Gallagher System Integrations

MultiSite Manager. Setup Guide

Honeywell Total Connect Remote Services

USER S GUIDE. AXIS Cross Line Detection

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

Intelligent Video Analysis

NextGen Home Security. Quick Reference Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

MPL3115A2 Sensor Toolbox User s Guide

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Ontech GSM 9040/50. Reference Manual English -1 -

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

Chapter. Configuring Genetec Omnicast. Version 4.7 SR1. Configuring Third-Party Programs. SightLogix, Inc

Smoke Detector and Siren. Manual

SIMPLIFIED HOME SECURITY AND CONTROL

Interfacing with the ADAM Module

Integration Guide AXIS Camera Station and AXIS A8004-VE

User Manual. Dryer Controller M720

Patriot Systems Limited

Evaluation of Biomek FX SV 96 Method Gripper Moves

SC-F3G User Manual 1.0

TITLE RS20i Atmos & DTS:X Decoder Card (H693) Setup

OnGuard 7.2 Resolved Issues

Configuration and Operation Manual for the Unipos

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

Alarm Manager Plug-in

Trident User s Manual

Before you install ProSeries Express Edition software for network use

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Avigilon Control Center System Integration Guide

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

IndigoVision Alarm Panel. User Guide

Proliphix. NT10e & NT20e. Configuration Guide

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

Transcription:

Configuration Guide XX206-40-01 VMD Guide for V960 Series Cameras Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788 Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose. www.vicon-security.com Document Number: 8009-8206-40-01 Product specifications subject to change without notice. Issued: 1111 Copyright 2011 Vicon Industries Inc. All rights reserved.

Guide for Configuring and Using Video Motion Detection 1 Guide for Configuring and Using Video Motion Detection on V960 Series Cameras This guide provides a step-by-step procedure for using the Video Motion Detection feature of V960 cameras with ViconNet (version 6.5 and higher). It assumes an understanding of ViconNet and the cameras. Refer to the ViconNet and camera manuals for detailed information. The Video Motion Detection (VMD) feature activates an alarm due to activity beyond specified sensitivities in preconfigured regions of interest (ROIs) in the camera view area. Since initial setup and configuration of V960 cameras are not done through VNSetup software but through a Web Browser interface, the support for a VMD alarm event is generated by the camera and is defined and setup in the camera configuration. The VMD message is sent from the camera and received in ViconNet as an external alarm; it can then be used to trigger a macro. These cameras support both open (video stream between the camera and PC must be established and kept open in order for alarm to be received) and closed (camera is capable of sending the alarm even if a video stream is not open) stream VMD. Cameras that support a closed stream of video for VMD do not have to be running to trigger the alarm. However, each camera that has VMD configured must be connected to be viewed or recorded at least once before the alarm mechanism will work. In some cases, a handshake macro must be configured to create this handshake and to ensure that the alarm will be re-activated and triggered even if the NVR reboots, shuts down or fails. The closed stream method saves storage but does not provide the prealarm option. An open stream video should be used if constant recording, prealarm or control of fps is required.

2 Guide for Configuring and Using Video Motion Detection Camera Configuration This section explains how to configure the Vicon V960 cameras for video motion detection (VMD feature) to work properly. The ViconNet system and the camera should be setup and connected before beginning this procedure. V960 Series Cameras These cameras can be configured with either open or closed stream video. Review the requirements for the particular installation to determine which way is best. Additionally, these cameras provide for using dual-stream configuration, which may be required for certain installations. Select the Setup tab on the Live screen. Click the Video tab on the left side of the screen and select Codec; the following screen displays. Select Video Stream

Guide for Configuring and Using Video Motion Detection 3 Depending on the required operation, it may be necessary to configure more than one video stream. If recording is to be set to start only when motion is detected, it is only necessary to set up one stream with the desired parameters. If it is required to have the system record at a certain fps all the time (usually lower rates), and switch to a different fps on motion (usually a higher rate), the Boost feature in the camera can be used (minimum camera firmware 1882.96). The Boost feature is setup in the camera web browser and allows the camera to run in one selected fps and automatically change to a different fps upon motion detection. Additionally, if it is required to have the system record at a certain resolution and quality all the time (usually lower one), and switch to a different resolution and quality on motion (usually a higher one), the two streams need to be configured with the different resolutions. Note that when the ViconNet macro is set up, it distinguishes between the different streams from the camera by resolution; that is why each stream must be set to a different resolution. Refer to the camera manual for details. Video Stream 1 Settings for resolution, quality, etc Video Stream 2 Settings for resolution, quality, etc. Boost Feature

4 Guide for Configuring and Using Video Motion Detection From the Event tab, select Motion. The following screen displays. Note that motion detection is set up only on the stream that will be associated with the VMD macro. Select Motion Click Area 1-4 button for the area to be defined and select the corresponding area for motion detection by clicking the relevant color box. Click the box on the video image where the motion area is to be located and adjust the size of the area by dragging the outlined box across and down in one motion. Adjust the Object Sensitivity from the drop down list, 1-10. The Sensitivity list only displays when an area is selected; it is not visible when All View is selected. Use the Selectall button to have the entire scene in the selected area. Deleteall is available to eliminate all selected areas. Click Save. When motion occurs in the defined area, a red dot appears on the Live video Refer to the section on Creating Macros for the next step.

Guide for Configuring and Using Video Motion Detection 5 Configuring ViconNet Creating Macros Examples of VMD Alarms Example 1 Example 2 Example 3 The next step in supporting VMD alarms is to create a macro that defines what happens when motion occurs. After the macro is defined it is then linked to the external alarm of the NVR/Workstation. Remember that recording is not available on a Workstation, only on an NVR or DVR. Below are three examples. A camera is recorded at a low fps and switches to a higher fps upon motion. The NVR is set to record the camera at MAX fps The camera VMD is set to generate an alarm on motion The Boost feature on the camera is set to ON and the lower and higher fps are set On the NVR, the macro will continue to record, but now at the higher fps. The whole fps change is done by the camera. Note: There is no higher fps pre-alarm option for this; any recording prior to the VMD alarm is at the set lower FPS A camera is recorded, and display is triggered by motion. The NVR is set to record the camera at desired fps The camera VMD is set to generate an alarm on motion On the NVR, the VMD alarm trigger runs a 2 nd macro that will start display of the camera on the desired Workstation Note if this can be combined with the Boost feature described in Example 1 A camera is only recorded by motion. A Workstation is viewing the camera as needed The camera VMD is set to generate an alarm on motion On the NVR, the VMD alarm trigger runs a macro that will trigger recording on the NVR Note: There is no pre-alarm at all in this case.

6 Guide for Configuring and Using Video Motion Detection When VMD is on a camera that is recording (open stream configuration), the recording macro is created first. The VMD trigger is a second macro. To create a macro: From the ViconNet Main window, click. The Setup Site Selection window displays. Select the site (NVR/Workstation) for which the macro is being defined and click. The System Settings window displays. Click. The Macro Editor window displays. In examples 1 and 2, the camera is recording before the VMD trigger, so a recording macro must be created. Click. The middle section of the screen displays. Add Macro Commands List Select Camera Fill in a logical name for the macro and a description if desired. Select the cameras that are being configured from the device list. Select the first command from the Commands list; in the example, select Record. The bottom portion of the screen displays. Fill in all pertinent fields for the command. The V960 cameras will not allow fps selection and the user will define the quality requested (Q1 for highest available stream, Q8 for lowest). In example no. 1, define recording at the desired resolution, typically Q1 for the higher quality stream, and for example no.2, recording at Q1 for the higher rate stream; remember this must correspond with the camera stream setting. A macro can have multiple commands; repeat command selection if required for the macro. The macro executes in the command order.

Guide for Configuring and Using Video Motion Detection 7 Click and then. In certain cases, a second macro is now configured to tell the NVR what to do in the case of a VMD alarm; as in the example, to display video from the camera. The third example does not require the first macro; this alarm macro instructs it to record the camera upon a motion alarm. Follow the previous steps to create the macro. To setup example 1: Nothing else needs to be done. The main macro will record all the time and the camera will increase FPS where motion is sensed. To setup example 2: From the Commands list, select Display. This allows the video to display on the local Workstation/NVR. If it is required that the video display on a different unit, create another macro using with the Send Alarm command and select the Destination of the video. To setup example 3: From the Commands list, select Record. Select the recording stream for the Record command (usually Q1). From the device list, select. This links the camera to the external alarm and uses the camera name as shown in the alarm for the macro to work (eliminating the need to specify which camera is for this macro). Note: This method has one limitation. A macro that runs as a result of ANY alarm will always trigger the same response (for example display the alarmed camera) and does not allow launching different macros for different alarms. If there is a requirement to do so, you will need to utilize ViconNet Events Management (see ViconNet manual). A camera that is running closed video requires a handshake macro to assure the system recognizes the alarm. Running this macro on the camera for 10 seconds every hour will assure that the VMD will be triggered even if the NVR restarted or lost communication to the camera at some point. To create the handshake macro: Follow the previous steps to create the macro. Configure a macro to record the camera every hour for 10 seconds so that the system maintains recognition of the camera.

8 Guide for Configuring and Using Video Motion Detection Configuring the Macro Scheduler Next, a schedule needs to be created to run the 24/7 recording macro and/or the handshake macro according to your requirements, including on which days of the week, as well as a start time and end time for each day. Refer to the Creating Schedules section in the Configuring ViconNet chapter in the latest ViconNet manual, XX113. From the ViconNet Main window, click. The Setup Site Selection window displays. Select the site name (NVR/Workstation) for which the alarm is to be defined and click. The System Settings window displays. Click.. The Scheduler Settings window is displayed, showing any currently defined schedules in the system. Click. The Scheduler Settings window is enabled.

Guide for Configuring and Using Video Motion Detection 9 From the Macro dropdown list, select the macro for which you want to create a schedule. The defined macro description is displayed automatically in the Macro Description field. Select the days of the week that you want the macro to run from the Sunday - Saturday checkboxes. To select a specific date for the macro to run, click in the Specific dates area. A calendar is displayed. Select the date/s required by clicking in the calendar. For the recording and handshake macros, every day of the week should be checked. In the Active From and To fields, define the start and end time (in HH:MM:SS format) for the macro to run on each of the selected days, as follows: Select the required time segment and then use the up/down arrows to scroll to the required value, OR select the required time segment and then use the keyboard to type in a numerical value. If the Active From and To times are the same, the schedule will be for a 24-hour period; this is used for the recording and handshake macros. In the Options area, select a run option for the macro; for the 24/7 recording (examples 1 and 2), select Continuously; for the handshake macro, select Launch Every and select 1 hour. Click.

10 Guide for Configuring and Using Video Motion Detection Configuring the External Alarm The final step is to configure the external alarm on the Workstation/NVR to activate the macro upon receiving the VMD alarm. Each NVR/Workstation has 1 default External Alarm that can be edited to receive the VMD alarm from the camera and execute the macro. To define the external alarm: From the ViconNet Main window, click. The Setup Site Selection window displays. Select the site name (NVR/Workstation that has the ability to receive alarms) for which the alarm is to be defined and click. The System Settings window displays. Click. The Active Detectors & Associated Macros window displays. Alarm Display Settings Add Detector Edit Detector Select the alarm display settings at the top of the screen. From the displayed list, select External Alarm. Click. The Alarm Setup Wizard window displays. Note: If the External Alarm has been previously deleted from the NVR/Workstation, click. From the Alarm Setup Wizard, select External Alarm and that follow.. Proceed with the steps for Edit Detector

Guide for Configuring and Using Video Motion Detection 11 Define the time schedule for the macro in the Alarm Activity Time area; the default is 24 hours a day, 7 days a week. Press. From this Alarm Setup Wizard, select the macro previously created to be activated when the motion alarm occurs (in examples 2 and 3). Linked to related devices should say Yes. If the macro was not created, or needs to be changed, it can be done by clicking. Follow the procedure for creating a macro. Click. Select Macro Yes displays The external alarm setup link is displayed in the list in the Active Detectors & Associated Macros window. Click Show Details to see complete information on alarm setup.

Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-2288 800-645-9116 Fax: 631-951-2288 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Vicon Germany Kornstieg 3 D-24537 Neumuenster Phone: +49 (0) 4321 8790 Fax: +49 (0) 4321 879 97 Far East Office Unit 5, 17/F, Metropole Square 2 On Yiu Street, Shatin New Territories, Hong Kong (852) 2145-7118 Fax: (852) 2145-7117 Internet Address: www.vicon-security.com