Panel Remote Annunciators Installation Instructions

Similar documents
Network Display Unit Installation Instructions

/9308 External Battery Chargers Installation Instructions

/ XPS Interconnection Diagrams

4100U City and Relay Cards Installation Instructions

Class A and Expansion NAC Modules Installation Instructions

Panel Message Memory Expansion Cards Installation Instructions

4009 Fiber Optic Link Option Installation Instructions

/5121/5122 TrueAlert Power Supply Installation Instructions

AU MX Digital Loop Card Installation Instructions

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

Addressable IDNet Isolator Installation Instructions

4100ES Fire Alarm System

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

Functional Performance Test

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.

4100ES Fire Indicator Panel Installation & Maintenance

Doc. No Part No Rev. U * T*

4100ES Fire Control Panels

Fire Control Panels. Network Annunciator Panels Network Display Unit (NDU) UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features

TrueAlarm Analog Sensing

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

4010 Fire Alarm Parts List

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

System Accessories, LCD Annunciators

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Fire Control Panels. Basic Panel Modules and Accessories

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features

Software Release M2.7 Summary for the Notifier AM2020/AFP1010 Fire / Security Control Panels, Including NOTI FIRE NET and Peripherals

TrueAlarm Fire Alarm Controls

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

LifeAlarm Fire Alarm Controls

Certificate of Conformity Certificate num. Registration date Version Valid until

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Units. Addressable Fire Detection and Control Basic Control Unit Modules and Accessories. UL, ULC Listed; FM Approved* Features

IFS Fiber Module Installation & Operation Instructions

4007ES Fire Control Panels

4007ES Fire Control Panels

4100ES-S1 Fire Indicator Panel Installation & Maintenance

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

TrueAlert Addressable Notification Appliances

Long Range Radio Alarm Transmitter

IFS Fiber Module Installation & Operation Instructions

CHERRY POINT BOQ B-487 CHERRY POINT, NC. Fire Alarm System Equipment Data Submittal February 4, Dividend Loop Myrtle Beach, SC 29577

TrueAlarm Fire Alarm Systems

4010 Fire Alarm PC Programmer Installation and Programming Instructions

Rev. B. TrueAlert Addressable Controller Application Manual

Network Hardware and wiring (quiz)...

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

TrueAlarm Fire Alarm Systems

TrueAlert Addressable Notification

LifeAlarm Fire Alarm Control Panels

TrueAlarm Fire Alarm Systems

R Series Remote Annunciators and Expander Installation and Operation Guide

4010 Fire Alarm Front Panel Installing, Operating, and Programming Instructions

4010 Fire Alarm Applications Manual

IDNet and MAPNET II Addressable Devices

SEE DISCLAIMER ON REVERSE

4007ES Fire Control Panels

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

R-Series Remote Annunciators and Expanders Installation and Operation Guide

Fire Detection and Alarm

IFS Fiber Module Installation & Operation Instructions

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

4005 Fire Alarm Installation and Operating Instructions

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

The RPT-485W/RPT-485WF

TrueAlarm Analog Sensing

Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

Alarm annunciation, control and communication systems

Long Range Radio Alarm Transmitter

30.45 Electric Release PDRP-2001

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

TrueAlert Addressable Notification Appliances

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

The System 5000 Operating Manual

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

TrueAlert Addressable Notification Appliances

TrueAlarm Fire Alarm Systems

Fire Alarm Network Reference

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SECTION FIRE DETECTION AND ALARM

IFS Fiber Module Installation & Operation Instructions

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

DS7400Xi Addressable Control/ Communicator

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Multi-Point Peripherals

IFS Fiber Module Installation & Operation Instructions

Multi-Point Peripherals

NETWORK FIRE ALARM CONTROL PANEL. Features

TrueAlarm Fire Alarm Systems

TrueAlert ES Addressable Notification Appliances

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

CATALOG NUMBER. Features. Description

Transcription:

Panel Remote Annunciators Installation Instructions Introduction This publication describes the installation procedures for the following PIDs: 4100-9607 Remote Annunciator w/ Flexible User Interface Domestic 4100-9608 Remote Annunciator w/ Flexible User Interface - Canadian 4100-9609 Remote Annunciator w/ Flexible User Interface - International 4100-9610 Remote Annunciator 4100-9611 Basic Remote Annunciator 4100-9612 Basic Remote Annunciator w/ Flexible User Interface - Domestic 4100-9613 Basic Remote Annunciator w/ Flexible User Interface - Canadian 4100-9614. Basic Remote Annunciator w/ Flexible User Interface - International This product is compatible with 4100U and 4100ES Fire Alarm Control Panels (FACP). IMPORTANT: Verify FACP System Programmer, Executive, and Slave Software compatibility when installing, or replacing system components. Refer to the Technical Support Information and Downloads website for compatibility information. In this Publication This publication discusses the following topics: Topic See Page # Cautions and Warnings 2 Remote Annunciator Installation 3 Specifications Power Requirements (4100-9610 and 4100-9611) Input Voltage 19-33 VDC Input Current 87 ma standby or alarm Power Requirements (all models with Flexible User Interface) Input Voltage 24 VDC Input Current 186 ma standby, 214 ma alarm Environmental Specifications Operating Temperature 32 to 120 F (0 to 49 C) Humidity Up to 93% relative humidity at 90 F (32 C) 2006-2011 SimplexGrinnell LP. All rights reserved. Specifications and other information shown were current as of publication and are subject to change without notice. Simplex and the Simplex logo are trademarks of Tyco International Ltd. and its affiliates and are used under license. 579-271 Rev. H

Cautions and Warnings Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in this installation manual. These instructions must be followed to avoid damage to this product and associated equipment. Product operation and reliability depend upon proper installation. DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED- Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately file a claim with the carrier and notify an authorized Simplex product supplier. ELECTRICAL HAZARD - Disconnect electrical field power when making any internal adjustments or repairs. All repairs should be performed by a representative or authorized agent of your local Simplex product supplier. EYE SAFETY HAZARD - Under certain fiber optic application conditions, the optical output of this device may exceed eye safety limits. Do not use magnification (such as a microscope or other focusing equipment) when viewing the output of this device. STATIC HAZARD - Static electricity can damage components. Handle as follows: Ground yourself before opening or installing components. Prior to installation, keep components wrapped in anti-static material at all times. FCC RULES AND REGULATIONS PART 15 - This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. SYSTEM REACCEPTANCE TEST AFTER SOFTWARE CHANGES - To ensure proper system operation, this product must be tested in accordance with NFPA 72 after any programming operation or change in site-specific software. Reacceptance testing is required after any change, addition or deletion of system components, or after any modification, repair or adjustment to system hardware or wiring. All components, circuits, system operations, or software functions, known to be affected by a change, must be 100% tested. In addition, to ensure that other operations are not inadvertently affected, at least 10% of initiating devices that are not directly affected by the change, up to a maximum of 50 devices, must also be tested and proper system operation verified. NFPA 72 is a registered trademark of the National Fire Protection Association. 2

Remote Annunciator Installation Introduction The 4100-9607, -9608, -9609, & -9610 remote annunciators are configurable 4100U/4100ES Fire Alarm System Panels that provide annunciation and limited system control for remote areas. The 4100-9610 remote annunciator is used when LED/Switch door modules are located in a transponder cabinet. A power supply (SPS, RPS etc.) is required. Other 4100U/4100ES modules may be located within the transponder cabinet. The other three remote annunciators contain a Flexible User Interface, which has a large screen LCD. The remote annunciators are MINIPLEX panels. The 4100-9611, 4100-9612, -9613 and -9614 are not used with local power supplies. Only annunciator modules are located in these cabinets. Power is wired to the Transponder Interface Controller. 4100-9611 is for applications where LED/Switch door modules are located in a transponder cabinet. The other PIDS include Flexible User Interface modules. LED/Switch modules may be added in the same cabinet when multi-bay cabinets are used. The modules below are commonly located in Remote Annunciator cabinets 4100-1292 Remote Command Center (RCC). The RCC s 2x40 character LCD can display any alarm, trouble or supervisory condition. The remote annunciator also provides basic user capabilities, such as system reset, alarm, and acknowledgment for supervisory and trouble indications. Not used with Flexible User Interface modules. 4100-1288, 4100-1289 LED/Switch Controller with 4100-1276 to -1278 & 4100-1280 to -1287 LED/Switch Modules The LED/switch user interface consists of a variety of display modules, mounted to the front of an expansion box, that are configured via the Programmer. Each display module contains between 8 and 24 switches and LEDs. Each switch and LED is separately configurable. 4100-0633 Tamper Switch. Wired to an input point programmed for annunciation when the door to the cabinet is opened. (4100-9607, -9608, -9609, & -9610 only) 4100-1291 Remote Unit Interface Module. Used to extend the length of communications wire to reach remote bays. Only 1 level or RUI cascading is permitted by the 4100U/ 4100ES architecture. (4100-9607, -9608, -9609. & -9610 only) 4100-1290 24-Point Graphic I/O Module. Allows up to 24 inputs or outputs to be programmed and connected to the 4100 Fire Alarm Control Panel. These 24 points can be split up into any combination of inputs and outputs to meet customer requirements. RPS, Expansion Power Supply (XPS) or Expansion System Power Supply. Each RPS provides 24 VDC and 3 notification appliance circuits. The SPS and RPS include a battery charger. The SPS includes an IDNet channel controller. Note: These modules mount to the front of the bay, and are restricted from mounting directly in front of power modules due to physical interference. Continued on next page 3

Remote Annunciator Installation, (continued) General Setup Remote annunciators are made up of several modules, and each module has its own set of installation instructions. The figures below and on the next page show the general setup for each remote annunciator. Refer to the appropriate manuals to install specific modules. Manuals are found in the ship group for each module. As shown in the figures, expansion bays with the power distribution interface (PDI) are always used in the remote annunciator. (CPU bays are never used.) Figure 1. 4100-9607, -9608, -9609, & -9610 Remote Annunciator Installation (4100-9610 Shown) Figure 2. 4100-9611, - 9612, -9613, & -9614 Basic Remote Annunciator Installation (4100-9611 Shown) Note: The Remote Command Center is an option with 4100-9610 and 4100-9611. Continued on next page 4

Remote Annunciator Installation (continued) Wiring for the Remote Annunciator Assembly The field-wiring to 4100-9611, -9612, -9613 and 4100-9614 Remote Annunciators is 24V power and RUI communications. Refer to Figure 3 for wiring information. Figure 3. Wiring for 4100-9611, 4100-9612, 4100-9613, and 4100-9614. TIC Assembly Used on the the Remote Annunciator 5

Remote Annunciator Installation (continued) Wiring for the Basic Annunciator Assembly The 4100-0620 TIC Assembly is used on the 4100-9607, 4100-9608, 4100-9609, and 4100-9610 remote annunciator. Refer to Figure 4 for wiring information. Figure 4. Wiring for the Basic Annunciator TIC Assembly 579-271 Rev. H