Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Similar documents
Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Mosaic System-Control Room Technology. Illuminated Pushbutton and Pushbutton Switch LT 1879 / LT 2479 LS 1879 / LS 2479

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Remote alarm indicator and test combination MK2430

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ME 3011C / Alarm Indication / Quick Reference Guide

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Signal Processing System ME30 infobox

STT 3000 Series STT250 /150 Surge Protection Device Specifications

PolyGard 2-channel Gas Controller MGC-03

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

LABORATORY GLASSWARE - GRADUATED MEASURING CYLINDERS (ISO 4788:2005) IRISH STANDARD I.S. EN ISO 4788:2005. Price Code

M2500 Engine Controller Installation Manual

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Operating Manual MS220KA and MSR220KA

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

1.7. Insulation fault evaluators EDS460/490 EDS461/491

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Universal fault annunciator for panel mounting

This document is a preview generated by EVS

Insulation fault evaluator EDS460-DG

HEXALOBULAR INTERNAL DRIVING FEATURE FOR BOLTS AND SCREWS (ISO 10664:2005) IRISH STANDARD I.S. EN ISO 10664:2005. Price Code

Accuracy counts! Sensors with analog output

ISO INTERNATIONAL STANDARD. Rotary positive displacement pumps Technical requirements

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

SOUTH AFRICAN NATIONAL STANDARD

Analog Annunciator Unit SACO 16 A3. Product Guide

PAPER - DETERMINATION OF BURSTING STRENGTH (ISO 2758:2001) IRISH STANDARD I.S. EN ISO 2758:2003. Price Code

Parameterisable compact fault annunciator with permanent display

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

REA 105 Arc Protection Module. Operator s Manual

THERMASREG TR 040 THERMASREG TR 060

CE GUIDELINE IEC. CENELEC (Comité Européen de Normalisation Electrotechnique European Electrotechnical Standardisation Comitee)

Installation Instructions

International standards used locally worldwide ISO/TC 67

CLEAR LIQUIDS - ESTIMATION OF COLOUR BY THE GARDNER COLOUR SCALE - PART 1: VISUAL METHOD (ISO :2004) IRISH STANDARD I.S. EN ISO :2005

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

ILNAS-EN ISO 10684:2004

Installation contactors ESB..

PRODUCT INFORMATION. SureSense THE SURE WAY TO DETECT ANY OBJECT. Photoelectric Sensors

Pillow Plate Heat Exchanger SYNOTHERM

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Theoretical Background

Pillow Plate Heat Exchanger SYNOTHERM

EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.

Granule Gastro/Combi

UV Flame Supervision System

Operation Manual Part-No

Thermal Management Products & Accessories for Enclosures

PROTECT SRB 200EXi-1A

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

IT system floor-standing distribution

This document is a preview generated by EVS

Signal converters SVE4 Product overview

KNX The worldwide STANDARD for home and building control. KNX Association International

ILNAS-EN ISO 23640:2015

AO Annunciator Module

Hexagon regular nuts (style 1) - Product grades A and B (ISO 4032:2012)

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Application guide RDG160 Remote control

Installation, operating and maintenance ARIA

AGREEMENT CONCERNING THE ADOPTION OF UNIFORM CONDITIONS OF APPROVAL AND RECIPROCAL RECOGNITION OF APPROVAL FOR MOTOR VEHICLE EQUIPMENT AND PARTS

VAMP 120 & 121. Arc flash detection units. Product picture

ISO INTERNATIONAL STANDARD. Footwear Test methods for whole shoe Washability in a domestic washing machine

For more information on Tarkett go to

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

SOUTH AFRICAN NATIONAL STANDARD

Monitoring Devices 11/1

Fästelement Blindnitar av splinttyp med genomgående hål och sänkhuvud AIA/St (ISO 15978:2002)

CROSS RECESSED RAISED COUNTERSUNK HEAD DRILLING SCREWS WITH TAPPING SCREW THREAD (ISO 15483:1999) IRISH STANDARD I.S. EN ISO 15483:2000.

Residual Current Devices

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Multi-Gas-Controller MGC2

Return loss measurement of fiber optic components

Cleanroom systems. Supply air ceiling and recirculated air ceiling OP. for operating rooms with low-turbulence displacement flow

Beckhoff short profile

MSM - Expansion modules

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

ISO INTERNATIONAL STANDARD. Rotary positive displacement pumps Technical requirements

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

This document is a preview generated by EVS

CONVENTIONS CONCERNING ELECTRIC AND MAGNETIC CIRCUITS (IEC 60375:2003) IRISH STANDARD I.S. EN 60375:2003. Price Code

Transcription:

Electronic Standard Devices Annunciator Relay MR and MRE MR 2 and MRE 2

The products described in this brochure are intended for industrial use and meet the requirements laid down by the EU directive 7 / 2 / EU (issued by the Council for Coordination of the Regulations of EU Member Countries regarding the electrical equipment for use within certain voltage limits, revised by directive 9 / 6 / EU issued by the Council) The contents may be subject to modification for the purpose of technical improvement. The general regulations applicable to installation and commissioning must be observed. No warranty can be accepted.

Contents Contents Page Annunciator Relay MR 4 Application 4 Design 4 Principle of Operation 4 Characteristics 4 Installation 4 Relay Assemblies 4 Ground-fault Annunciator Relay MRE 4 Application 4 Principle of Operation 4 Installation 4 Annunciator Relay MR 2 Application Principle of Operation Installation Ground-fault Annunciator Relay MRE 2 Application Principle of Operation Installation Technical Characteristics Special Designs Contact Diagrams MR 6 Contact Diagram MRE 7 Setting N/O or N/C operation 7 Contact Diagrams MR 2 Contact Diagram MRE 2 Dimensional Drawings of the Single Relays 9 Plug-in Surface Mounting 9 DIN Rail Mounting 9 Flush Mounting 9 Plug-in Flush Mounting 0 Changing the Indicator Flag Label 0 Dimensions of the Casings acc. to DIN 4700 4 Annunciator Relays 9 Annunciator Relays Dimensional Drawings of the Relay Assemblies 2 Casing for Flush Mounting in Control Panel 2 Casing for Surface Mounting in Control Panel Order References and Ordering Examples 4 Annunciator Relay

Annunciator Relay MR Application The MR annunciator relay is used for the indication of danger and alarm situations and operational states. Its miniature size (9 x 46 mm ground surface) makes it suitable to be combined in large numbers so that the entire relay assembly can be used for alarm and status signalling in control rooms, control panels and mimic diagrams. Design The MR is a semi-automatic relay which can be switched in N/C or N/O mode. The required switch action - N/C or N/O - is set in the factory prior to delivery, according to customer order specifications. Subsequent modifications can be carried out by the manufacturer. Apart from the coil excitation voltage, no other auxiliary voltage is required for visual signal indication. This is a valuable feature particularly in those applications where the relay has the task of monitoring voltages. Principle of Operation The entire indicator flag area is black when the relay is in its normal mode and ready for operation (optional: grey RAL 707 indicator flag for relay assemblies). As soon as the relay picks up, the indicator flag becomes visible (white field with written characters). At the same time, the contacts move into their working position. Operating the reset button situated immediately below the indicator flag panel acknowledges the message. The indicator remains visible, but now an additional flag with red-white shaded lines appears. At the same time, the contacts return to their normal position. The relay s flag area automatically returns to its normal status upon elimination of the fault situation. Apart from the operation described above, it is also possible to actuate the contacts directly from the pallet system. This type of contact configuration is particularly required in remote controlled plants. Contact diagrams: see pages 6 and 7 Characteristics Easily replaceable indicator flag label, position-independent, tropicalized protection class upon request. Relay Assemblies Installation in DIN 4700 instrument casing designed for flush mounting in control panels Size of casing: 96 x 96 mm for 4 relays Size of casing: 44 x 44 mm for 9 relays Dimensional drawings: see page Mounting in combi-enclosures for flush mounting in control panels with 0 annunciator relays max. Dimensional drawing: see page 2 Mounting of relay assemblies in enclosures for surface mounting in control panels, wall mounting or installation in control cubicles, with 9 relays or 4 relays Dimensional drawings: see page Upon request, relay assemblies are delivered together with rail wires and connection angles of different heights, or these can be mounted in the factory prior to delivery. They bridge the connection points of identical potential. Upon request, relay assemblies with surface mounting enclosures are wired directly in the factory prior to delivery. Upon request, the relay connections are protected by a plastic cover in order to meet the VBG4 standard for protection against accidental contact. Ground-fault Annunciator Relay MRE Application The MRE annunciator relay is a semi-automatic relay used for the indication of earth leakage faults in three-phase networks. Principle of Operation The relay is equipped with two windings and must be connected to the open delta winding of a displacement transducer. The relay picks up at 0 V a.c. This has the effect of adding the second winding into the relay circuit which protects the relay against overload at a voltage increase up to 00 V a.c. The MRE ground-fault annunciator relay is also available for other voltage ranges. Operation and indication method of the MRE relay are the same as for the MR relay described opposite. Contact diagram: see page 7 Installation Single relay Control panel surface mounting, plug-in Accessories: connector plate, fixing screws with nuts Dimensional drawing: see page 9 DIN rail mounting ( mm) Accessories: connector plate with bracket Dimensional drawing: see page 9 Control panel flush mounting, Accessories: strap retainer, mounting frame, contact protection cover acc. to BGV A2 Dimensional drawing: see page 9 Control panel flush mounting, plug-in Accessories: connector plate, fastening bow, mounting frame Dimensional drawing: see page 0 Installation identical to MR 4 Annunciator Relay

Annunciator Relay MR 2 Application Just like the MR, the MR 2 annunciator relay is used for the indication of danger and alarm situations and operational states. Its miniature size (9 x 46 mm ground surface) makes it suitable to be combined in large numbers so that the entire relay assembly can be used for alarm and status signalling in control rooms, control panels and mimic diagrams. Principle of Operation Unlike the MR relay, the MR 2 annunciator relay is fully automatic. It has no manual reset button and no NO/NC change-over facility. Depending on the preset contact mode (N/O or N/C operation) the relay picks up either at energization or at de-energization. The contacts operate and the mechanical indicator flag is set. Upon return to normal of the fault situation the indicator flag is automatically acknowledged and the contacts return to their normal position. Contact diagram: see page Rated current (I N or I rated ) (current winding) Pick-up delay Power consumption at (V rated ) For d.c. with integrated protective resistor For a.c. and closed magnetic circuit open magnetic circuit Contact side Current at make Up to 6 A d.c. or a.c. 2 ms to 2 ms 0. W to. W W to 2. W.4 VA to. VA 2. VA to.6 VA 6 A d.c. or a.c. Installation identical to MR Ground-fault Annunciator Relay MRE 2 Application The MRE 2 is a fully-automatic annunciator relay for the indication of ground leakage faults in three-phase networks. Principle of Operation The MRE 2 is based on the same principle of operation as the MRE relay. Only difference: as the MRE 2 is fully-automatic it has no manual reset button, nor is it equipped with a change-over facility for N/O or N/C operation. Contact diagram: see page Installation identical to MR Technical Characteristics Continuous current Current at disconnect for 220 V d.c, L R = 40 ms for 220 V a.c., cos ϕ = 0.4 Permissible switching voltage Wiping time of fleeting contacts General Characteristics 4 A d.c. or a.c. 0.2 A 4 A 220 V d.c. or 20 V a.c. 60 ms approx. Protection class IP 40, connections IP 00 acc. to DIN 4000 Isolation group and series Group C, 20 V a.c./d.c. voltage acc. to VDE 00/.72 Test voltage acc. to VDE 04a/9.72 2kV, 0 Hz Permissible ambient temperature range - C to +40 C Labelling or 2 lines, characters max. per line Weight 0 g / 70 g standard design / with connector plate Excitation side Type of current Frequency Rated voltage (V rated or U N ) Rated voltage with integrated resistor Continuous overload capacity Pick-up voltage Direct or alternating current 0Hz or 60 Hz Up to 0 V d.c. or 20 V a.c. Up to 220 V d.c..2 x V rated 0. V rated The front frames and front panels of relay assemblies are black varnish coated to have the same appearance as the relay screen. Upon request and at an additional charge, these parts are also available in RAL 707 grey. Special Designs All annunciator relays of the MR series are also available in shockproof design. In this case, their designation is MRS and MRS 2. In addition to the standard contact diagrams shown in this brochure, a large number of special contact arrangements is available upon request, such as combinations of N/O - N/C and fleeting contacts. Delivery range, availability and prices: on request Annunciator Relay

Contact Diagrams for MR and MRE Diagram reference Relay status Normal Message Acknowledged 6 6 6 0- N/O current Magnetic system: no current Magnetic system: excited Magnetic system: excited 6 6 6 0- N/C current Magnetic system: excited Magnetic system: no current Magnetic system: no current 6 6 6 0-2 N/O current Magnetic system: no current Magnetic system: excited Magnetic system: excited 6 6 6 0-2 N/C current Magnetic system: excited Magnetic system: no current Magnetic system: no current 6 6 6 0-2a N/o current Magnetic system: no current Magnetic system: excited Magnetic system: excited 6 6 6 0-2a N/c current Magnetic system: excited Magnetic system: no current Magnetic system: no current 0- N/o current Magnetic system: no current Magnetic system: excited Magnetic system: excited 0- N/c current Magnetic system: excited Magnetic system: no current Magnetic system: no current Mechanical indicator flag Normal status: black Message status: white Acknowledged: white/red 6 Annunciator Relay

Diagram reference Relay status Normal Message Acknowledged 0-a N/O current Magnetic system: no current Magnetic system: excited Magnetic system: excited 0-a N/C current Magnetic system: excited Magnetic system: no current Magnetic system: no current 6 6 6 0-4 N/O current Magnetic system: no current Magnetic system: excited Magnetic system: excited 6 6 6 0-4 N/C current Magnetic system: excited Magnetic system: no current Magnetic system: no current Contact Diagram MRE 2 2 2 0-a Mechanical indicator flag 4 4 4 Magnetic system: no current Magnetic system: excited Magnetic system: excited Normal status: black Message status: white Acknowledged: whit Setting N/O current or N/C Operation The operation mode of the relay - N/O or N/C operation - is set in the factory according to customer order specifications. This setting can be modified. Control screws for N/O operation Control screws for N/C operation Annunciator Relay 7

Contact Diagrams for MR 2 and MRE 2 Diagram reference Relay status Normal Message 6 6 20- N/O current Magnetic system: no current Magnetic system: excited 6 6 20- N/C current Magnetic system: excited Magnetic system: no current 6 6 20-2 N/O current Magnetic system: no current Magnetic system: excited 6 6 20-2 N/C current Magnetic system: excited Magnetic system: no current 20- N/O current Magnetic system: no current Magnetic system: excited 20- N/C current Magnetic system: excited Magnetic system: no current Contact Diagram MRE 2 20-a Mechanical indicator flag 2 4 2 4 Magnetic system: no current Magnetic system: excited Normal status: black Message status: white Setting the N/C or N/O Operating Mode The required operating mode of the relay is set in the factory prior to delivery and must therefore be stated on the order. It is not possible to modify this setting on site! Annunciator Relay

Dimensional Drawings of the Single Relays Plug-in Surface Mounting 9 S 00 0 42 6 7 46 49 2 4 20 Connector plate When wiring is complete, the relay is plugged in and tightened with screw S. 2. mm 2 Accessories included: connector plate with 2 cylinder screws M x 0, DIN4 complete with nuts, and 2 round head wood screws M x0, DIN96 DIN Rail Mounting ( mm) 9 20 S ca.26 6 7 Side view Rear view Contact protection cover to BGV A2 6 4, 4 4 4, +0, -0 9 20 7 6 2 46 4 0, +0, -0 46 46 2 4 2, mm 2 Connector plate When wiring is complete, the relay is plugged in and tightened with screw S. Flush Mounting Push here to open 4 2 9 New strap retainer Mouting frame Panel cutout 40 mm x 47 mm, new strap retainer 4 mm x 2 mm Annunciator Relay 9

Plug-in Flush Mounting Top view Rear view 29 Connector for control panels of sheet thickness > mm Mounting frame Connector plate 7 6 4 2 Fastening bow The pull-out handle is screwed onto the bolt in place of the casing nut. 4 2 2. mm 2 Connector for panels of sheet thickness mm 00. 4 62 Panel cutout: 40 mm x 47 mm Accessories: connector plate, fastening bow, mounting frame, pull-out handle Changing the Indicator Flag Label Removing a single relay Untighten the nut of the reset button situated on the front plate and pull the relay casing towards you. Removing an annunciator relay from a combi-enclosure Remove the screw-type or plugged-in front frame. On all relays, remove the nuts of the reset buttons. Remove the glas cover. On the relay whose label you wish to change, pull the relay towards you using the pull-out handle. Flag label Front frame Metal sheet Pallet Changing the label Flip the pallet and bend the metal sheet situated just behind the front frame until it reaches the pallet. Take the label out of the front frame and insert the new label. Please make sure that the wire strap holding the label is properly inserted in the carrier. Wire strap Reset button Carrier Changing the label of the mechanical indicator flag 0 Annunciator Relay

Dimensions of the Relay Casings acc. to DIN 4700 4 annunciator relays of type MR or MR 2 9 annunciator relays of type MR or MR 2 Ø 44 96 Ø 96 9 max. 0 6 9 max. 44 0 6 64 0 2. mm 2 40 max. Contact protection cover to VBG 4, made of clear plastics, if required 4 64 0 2, mm 2 Contact protection cover to VBG 4, made of clear plastics, if required 40 max. 4 Rear view Rear view 7 6 7 6 7 6 7 6 7 6 4 2 4 2 4 2 2 4 2 4 2 7 6 7 6 2 92 20 7 6 7 6 7 6 4 2 4 2 4 2 20 4 2 4 2 7 6 7 6 7 6 4 2 4 2 4 2 *92 *Outer dimensions of casing, without taper rivets Panel cutout 92 +0, x 92 +0, * *Outer dimensions of casing, without taper rivets Panel cutout + x + Annunciator Relay

Dimensions of the Relay Assemblies Casing for Flush Mounting in Control Panel for MR and MR 2 Maximum size: 0 relay slots 70 0 0 90 20 270 0 0 90 40 470 0 0 90 60 Front frame Panel cutout Casing 0 4 90 0 70 2 6 2 4 20 20 20 24 6 290 2 7 0 2 70 6 9 40 40 0 40 44 490 4 2 0 2 70 6 4 60 60 76 6 4 22 02 00 6 4 46 24 94 92 260 240 2 06 26 24 2 2 0 9 7 76 444 424 422 2 4 6 7 9 490 470 46 0 6 6 4 2 62 60 2 62 60 606 674 64 62 4 720 700 69 29 29 Panel cutout Casing 40 max. "A" 0 Front frame ~ Detail view "A" 2. M4 9 2 Annunciator Relay

Casings for Surface Mounting in Control Panels for MR and MR 2 Casing for surface mounting for 4 annunciator relays 4 26 6 7 9 20 2 22 2 24 2 26 27 2 29 0. 4 70 202 2 4 6 7 9 0 2 4 7 Casing for surface sounting for 9 annunciator relays 4 26 6 7 9 20 2 22 2 24 2 26 27 2 29 0. 44 4 70 202 2 4 6 7 9 0 2 4 7 Annunciator Relay

Order References and Ordering Examples Please state the following details and requirements so that we can process your order as thorough as possible:. Which type of annunciator relay? 2. Which type of coil voltage and current? (d.c. or a.c.?). Reference of applicable contact diagram (please select the required contact arrangement and switching mode) 4. Required installation method: Surface mounting, plug-in type Flush mounting Flush mounting, plug-in type Relay assembly, complete with annunciator relays (please state size and relay configuration) Annunciator relay for insertion in already existing assembly. Accessories 6. Label texts, if required (message texts) 2. Relay assembly for 40 annunciator relays, equipped with 24 relays with different message texts, inclusive of rail wiring for coil outputs, non-acknowledgeable group message (N/O contact) and excitation of an external acoustic relay (fleeting contact) Combi-enclosure MR -0s x 0w for flush mounting in control panels 40 Connector plates MR -combi (for all relay slots, free slots included) 24 MR annunciator relays for 60V d.c Contact diagram reference: 0-a combi 6 Indicator flag labels, text line (supply drawing and list of texts) Indicator flag labels, 2 text lines (supply drawing and list of texts) 6 Blind plates (for free relay slots)) 200 Connection angles (for all slots, free slots included) 200 Mounting of connection angles, inclusive of rail wiring of relay contacts no. 2 (coil), no. and 4 (N/O contact for group message), and no. 7 and (fleeting contact for generation of acoustic alarm) Pull-out handle 7. Other special requirements, if applicable (e.g., tropicalized protection class) Ordering Examples. Flush mounting relay (single) with 2 acknowledgeable change-over contacts... Annunciator relay MR for 220 V a.c. Contact diagram ref. 0-2 flush mounting without (or with) prepared labels... Contact protection acc. to VBG 4 (not always required) 4 Annunciator Relay

Annunciator relay MR for flush mounting Annunciator relay MR with removed label Annunciator relay assembly 96 mm x 96 mm with 4 relays Annunciator relay assembly 96 mm x 96 mm, rear view Annunciator relay assembly 44 mm x 44 mm, with removed frame and relay removed using the pull-out handle Annunciator Relay

Representatives Germany Helmut Mauell GmbH Am Rosenhügel 7 D-42 Velbert Tel.: +49 (0)20 / 0 Fax.: +49 (0)20 / 6 Internet: www.mauell.com E-Mail: info@mauell.com For an up-to-date list of all our representatives and branch offices, please visit our homepage: www.mauell.com Representatives and Branch Offices All Over The World: Abu Dhabi U.A.E. Argentina Austria Belgium Brazil Czech Republic Denmark Finland France Great Britain Hungary Iran Korea Kuwait Netherlands Norway Poland Singapore Spain Sweden Switzerland Turkey USA 6.00.0E07